Topics (384k) Articles (398k) Users (410) Discussions (242) Comments (383) Files (13k) New article
The forebrain, also called the prosencephalon in embryological terminology, is the anterior major division of the developing vertebrate brain. It subdivides into the telencephalon and diencephalon. The name describes a developmental and anatomical grouping, rather than one nucleus with a single task.[ref]
Prosencephalon in NLM MeSH. Scope note and Forebrain entry term: anterior primitive cerebral vesicle derived from the neural tube and its two subdivisions.
The telencephalon includes the cerebral-hemisphere system, while the diencephalon includes regions such as the thalamus, hypothalamus and epithalamus. Thus the visible cerebral cortex is part of the forebrain but does not exhaust it. Deep nuclei and connecting pathways also belong to the region.[ref]
Neuroscience, 2nd edition edited by D. Purves and others. Gross organization of the brain and ventricular-system anatomical landmarks.
The ventricular spaces provide an illuminating map. The lateral ventricles lie within the cerebral hemispheres, while the third ventricle is associated with the diencephalic region. A fluid-filled cavity and its surrounding neural tissue are different structures: locating the cavity helps orient the tissue, but does not make the cavity itself a neuron-processing center.[ref]
This developmental grouping is useful when comparing brains whose proportions differ greatly. Expansion of one forebrain component does not erase the distinction among its components. Likewise, observing a response in the lateral habenula identifies activity in one forebrain circuit, not a computation performed uniformly by the entire forebrain.
Formula uncertainty versus surface-area model error separates precision in evaluating a body-size formula from adequacy of that formula for an individual's actual body surface area. Repeating height and mass measurements can reduce their sampling uncertainty without making the predicted anatomical surface exact.
The Mosteller formula, documented with centimetre and kilogram inputs in the VA manual, is .[ref]
Formulas for Body Surface Area Calculator in the VA Clinical Reminders Manager's Manual. Printed p. 36, Mosteller formula and input units
An original measurement model can instead write , where represents fitted coefficients and residual model discrepancy. Variation in body shape is not represented by improved arithmetic alone.For small independent input errors with fixed coefficients,Coefficient uncertainties, correlations and model discrepancy are additional terms when significant. The GUM explicitly requires a measurement model to include relevant corrections and quantities reflecting incomplete knowledge.[ref]
For stipulated prediction , input-related standard uncertainty and independent zero-mean discrepancy uncertainty , the combined value is . Reducing only the input term tenfold gives approximately , illustrating a repeatability floor from surface-area model discrepancy. These are constructed uncertainties, not published performance limits. A known nonzero model bias calls for correction; assigning a zero-mean random term does not remove it.
Normalization can transmit the discrepancy into another quantity. For fixed measured cardiac output , the ratio of to is . A stipulated true area 2.0 and predicted area therefore increases the indexed result by about 11.1%. Extra displayed digits do not resolve the anatomical mismatch.
A validation experiment compares predictions with independently characterized surface measurements over the intended range of body shapes and sizes, retaining uncertainty in the reference method. Report input repeatability, coefficient estimation, average bias and residual spread separately rather than interpreting them all as one source of error.
The Mosteller formula estimates body surface area from height and body mass using a single square root:Here and are numerical values in centimetres and kilograms. R. D. Mosteller's primary correspondence appeared in 1987; the VA calculator documentation explicitly states this equation and the required units.[ref]
Simplified calculation of body-surface area by R. D. Mosteller. New England Journal of Medicine 317, 1098, DOI 10.1056/NEJM198710223171717
[ref]Formulas for Body Surface Area Calculator in the VA Clinical Reminders Manager's Manual. Printed p. 36, Mosteller equation
For stipulated height 180 cm and mass 80 kg, . An equivalent metres-and-kilograms expression uses the divisor 36 rather than 3600: . Changing the height unit without changing the constant gives a tenfold area error. The constant belongs to the empirical formula and unit convention; the expression does not calculate an anatomical surface from first principles.
The equal-product ambiguity in height-mass surface estimates is instructive. Height 160 cm and mass 90 kg also give product 14,400 and the same predicted area. These two input pairs do not specify the same body shape or prove equal actual skin area. Additional anatomical information has been deliberately compressed into a two-input predictor.
Small relative changes obey . A 2% mass increase at fixed height therefore changes the predicted area by about 1%; the exact factor is . This sensitivity concerns the calculated prediction, not the accuracy of the empirical body model. Formula uncertainty versus surface-area model error separates those questions.
If a stipulated cardiac output of 5 L/min is divided by predicted area , the indexed value is . Normalization changes the quantity and its units. It does not independently validate the area estimate or make the indexed quantity a complete description of cardiovascular function. Record the exact formula and measured input units whenever such normalized results are compared.
PBD-BODIPY is the 1-phenylbutadiene-conjugated BODIPY signal carrier in a spectrophotometric method for radical-trapping antioxidants. The conjugated appendage distinguishes it from the styrene-conjugated carrier STY-BODIPY. In the primary method, each can co-autoxidize with a hydrocarbon substrate so that the changing optical signal follows reaction progress.[ref]
The shared scaffold does not make the two carriers interchangeable calibrants. Additional conjugation can alter the electronic structure, while substitution and solvent affect the spectrum and chemical response. Chromophore-specific calibration of antioxidant signal carriers is therefore needed before converting an absorbance slope into a chemical rate.
An original comparison assumes a PBD-carrier calibration and path length 0.5 cm. Absorbance 0.40 then represents 10 micromolar carrier. Substituting a coefficient of 50000 from another hypothetical dye would instead infer 16 micromolar, a 60% overestimate. These stipulated coefficients illustrate a calibration error; neither is asserted as a measured value for these compounds.
The same issue affects a rate. Under a Beer-Lambert law with unchanged absorbing species and coefficient,With the first illustrative coefficient and path, an absorbance slope gives carrier-loss rate . A raw optical slope is not yet a molecular consumption rate, and a carrier-consumption rate is not automatically an antioxidant-trapping rate.
A proposed comparison records separate starting spectra, matched reaction conditions and appropriate carrier and test-material blanks. Differences in lag duration and decay slope can constrain different parts of a kinetic model. A longer lag can reflect trapping capacity, while a changed slope also depends on the competition between propagation and trapping; neither readout should be assigned a unique molecular explanation without testing the response model.
The primary study explicitly seeks both kinetic and stoichiometric information. Preserve that distinction when comparing PBD-BODIPY with STY-BODIPY, rather than describing every signal decrease as an interchangeable measure of antioxidant concentration.
STY-BODIPY is the styrene-conjugated BODIPY signal carrier used in a visible-light assay of radical-trapping antioxidants. It co-autoxidizes with a hydrocarbon substrate, allowing reaction progress to be followed optically. The primary method distinguishes antioxidant reactivity from the number of radicals trapped.[ref]
A Continuous Visible Light Spectrophotometric Approach To Accurately Determine the Reactivity of Radical-Trapping Antioxidants by Evan A. Haidasz and others. Abstract, STY-BODIPY signal carrier and kinetic/stoichiometric aims
The manufacturer's record for the named material gives formula and formula weight approximately . Its method description follows loss of absorbance at 571 nm during co-autoxidation.[ref] This identifies a particular derivative and measurement channel; it does not assign one spectrum to every styrene-substituted BODIPY dye.
An original Beer-Lambert law example assumes a 1 cm path and calibrated molar absorption coefficient . Absorbance falling from 1.00 to 0.80 corresponds to signal-carrier concentration falling from 20 to 16 micromolar. The inferred 4 micromolar loss depends on that assumed coefficient and the identity of the absorbing species. Those numbers are illustrative, not a reported STY-BODIPY calibration.
A simple kinetic model writes , where represents a constant peroxyl-radical concentration. Then . An antioxidant that changes the radical population can change the optical decay, but the resulting trace must be interpreted through the co-oxidation model. Dye consumption alone does not count antioxidant molecules without further kinetic and stoichiometric information.
Dark-loss control for STY-BODIPY autoxidation tests one potential confounder. Proposed controls compare the signal carrier without radical initiation, under matched illumination and in the presence of test material that might itself absorb at the observation wavelength. These distinguish chemical oxidation from unrelated optical change or added absorbance.
Although the product is described as fluorogenic, the original assay discussed here uses visible-light spectrophotometry. Absorbance loss and fluorescence change are different observables. Specify the derivative, solvent, optical channel, blank correction and response model when using the named dye to compare antioxidant activity.
Modified n-gram precision measures reference-matched candidate n-grams while clipping repeated occurrences to the evidence available in the references. It is the precision component of BLEU. Merely asking whether a word appears anywhere in a reference would otherwise reward repeating that word indefinitely.[ref]
BLEU: a Method for Automatic Evaluation of Machine Translation by Kishore Papineni and others. §2.1 and footnote 2, clipped occurrence counts
For candidate sentence , let count n-gram , and let count it in reference . Its clipped match count isUse the maximum count in one reference for each n-gram, rather than adding counts across references. Corpus precision sums these clipped matches and divides by the total candidate n-gram count of that length, provided this denominator is nonzero. An implementation needs a stated convention when no candidate n-grams of that length exist.[ref]
For an own example, take reference
the cat the mat and candidate the the the cat. The candidate has three occurrences of the, but only two can match; cat contributes one more. Thus modified unigram precision is , whereas an unrestricted word-membership check would misleadingly credit all four words.The candidate's three bigram occurrences are
the the twice and the cat once. Only the last matches, giving modified bigram precision . Longer n-grams therefore test ordering distinctions that unigram counts cannot capture.The brevity penalty in BLEU reduces the score of a candidate translation corpus that is too short relative to its references. Matching a few reference phrases can give excellent modified n-gram precision while omitting much of the intended translation; the length factor addresses that particular failure.[ref]
BLEU: a Method for Automatic Evaluation of Machine Translation by Kishore Papineni and others. §2.2.2, motivation and sentence brevity penalty
For positive total candidate length and effective reference length ,Equivalently, . The effective reference length sums closest reference sentence lengths across the corpus; the penalty is then applied to the corpus totals.[ref]
For an own example, use reference
the cat is on the mat and candidate the cat is on. Every candidate n-gram of lengths one through four matches the reference, so all four modified precisions are one. Nevertheless, and giveWith the usual four equal weights, the full score in this example is also , because its precision geometric mean is one. Perfect candidate precision has not made an incomplete prefix a perfect translation.At , the factor is one. It remains one for longer candidates; their unmatched or repeated material can instead lower precision. A brevity penalty is therefore a length correction within a combined metric, not a complete measure of translation adequacy.
A submask of a bit mask is a bit mask whose set bits are all set in , equivalently . It represents a subset of the positions selected by . If has set bits, it has exactly submasks, including zero.
To enumerate them in descending order, start at , output , stop if , and otherwise replace it by . Subtracting one clears the lowest set bit and fills lower positions; masking removes positions unavailable in . For , the sequence is . Testing for zero before the next update is essential: under the common integer conventions, updating zero produces again and repeats the cycle.[ref]
Enumerating submasks of a bitmask in the CP-Algorithms documentation. Enumerating all submasks of a given mask
The number of outputs is exponential in the number of selected positions, even though each fixed-word update is inexpensive.Biocompatibility is the ability of a biomaterial to function with an appropriate response from the living system in a specified application. It relates the material, its intended function and its biological environment. It is therefore more informative to ask whether a particular finished component is compatible with a particular contact site and duration than to call a substance universally “biocompatible.”[ref]
Terminology for biorelated polymers and applications (IUPAC Recommendations 2012) by Michel Vert and others. Entry 106, biocompatibility in biomedical therapy
Consider the same nominal polymer used as a short-lived skin-contacting film or as part of a long-lived component contacting blood. Its chemistry alone does not specify the biological exposure. Surface treatment, processing residues, final preparation and the length and type of contact can change the relevant response. The FDA’s primary resource emphasizes the final finished device and explicitly identifies contact type, duration and component interactions as assessment variables.[ref]
Basics of Biocompatibility: Information Needed for Assessment by the FDA. How the FDA Assesses or Evaluates Biocompatibility; Biocompatibility Factors of Interest
A cytotoxicity experiment addresses one part of this question by examining adverse effects on biological cells. In a simple illustrative cell culture comparison, suppose a sample-exposed culture has 900 viable cells and a matched control has 1000 at the same observation time. The relative viable-cell count is . That ratio is an observation under the chosen conditions, not a complete compatibility verdict: growth rate, exposure preparation, measurement method and repeatability affect its interpretation. A control can distinguish a material-associated effect from an effect of the culture medium or preparation procedure.
Functional compatibility also need not mean that nothing happens at the interface. Some biomaterials are designed to bond to bone, so the desired response differs from that of a material intended merely to remain separated from surrounding tissue. Evidence about cell viability, local tissue organization and the component’s mechanical function answers different questions. A useful experimental account states which response was measured, the biological setting and exposure history, and the uncertainty in the comparison.
A bioactive glass is a glass designed to elicit a useful biological response at its interface, notably bonding with bone for some compositions and uses. It is a class of biomaterials, not a claim that every glass has the same response. Related glass-ceramics contain crystalline phases and should be distinguished from wholly glassy materials.
A motivating early experiment compared glass-ceramic solubility and interfacial hydroxyapatite crystallization with observations around implants in rat femurs. Larry L. Hench and colleagues examined histology and ultrastructure as well as laboratory interfacial changes. The question was how bonding developed at the material–bone interface, beyond the bulk material's mechanical strength.[ref]
Bonding mechanisms at the interface of ceramic prosthetic materials by L. L. Hench and others. primary Abstract, in-vitro interfacial studies and in-vivo implant observations
Contact with fluid can change the material's surface and release dissolved constituents. Geometry therefore matters alongside composition. For an original monodisperse spherical-powder model, radius and density give surface area per massAt stipulated and , this is , or . Increasing radius to reduces that area per mass tenfold. The example neglects pores and aggregation and is not a particular product's specification.
If initial release flux per unit area were equal in two such powders, their initial release rates per mass would differ by the same factor. Actual flux can change with solution composition and surface evolution; a biological response need not scale linearly with geometric area. Comparisons should therefore specify particle dimensions, exposed area, fluid conditions and time. Surface-layer formation, cytotoxicity, mechanical behavior and tissue bonding remain distinct observations rather than interchangeable proof of suitability.
Embryonic development is the organized sequence through which an embryo forms and differentiates before the later juvenile or fetal stages defined for its species. Cell division, movement, changing gene expression and interactions among neighbouring cells jointly build tissues and body organization. Developmental stage therefore describes more than elapsed time or total cell number.
Light-sheet imaging of living zebrafish embryos enabled repeated three-dimensional observation and tracking of nuclei across early development. [ref]
Reconstruction of zebrafish early embryonic development by scanned light sheet microscopy by Philipp J. Keller and others. 2008, live light-sheet imaging and nuclear tracking
Following one developing specimen distinguishes movement and ancestry from an ordering inferred solely from fixed specimens of different ages. A lineage record still does not by itself identify the molecular signals determining every descendant cell fate.Endemism is the restriction of a biological taxon's native distribution to a specified geographic region. A species can be endemic to one island, an archipelago or a continent; the region must be stated. Presence within a region is insufficient: the defining point is that its native range does not extend elsewhere at the stated scale.
The Seychelles warbler supplies a useful scale comparison. The research team's account identifies it as endemic to the Seychelles and describes conservation species translocations from the remnant Cousin Island population to other islands within the archipelago. Establishing populations on several Seychelles islands is compatible with endemism to the Seychelles; it is incompatible with describing its range as confined to Cousin Island alone.[ref]
Seychelles Warbler Project overview. Research team's introductory species account and translocation history; destinations include Aride, Cousine, Denis and Fregate.
Charles Darwin used island distributions as evidence in biogeography. In the first edition of On the Origin of Species by Charles Darwin, he explained endemic forms as those found nowhere else and compared affinities of island organisms with nearby mainland organisms. His Galápagos and Cape Verde comparisons connected geographic barriers and colonization with evolutionary modification.[ref]
On the Origin of Species by Charles Darwin. First edition (1859), chapter XII, p. 390 definition; pp. 398–403 island affinities and differences.
Endemism is a pattern to explain, not a complete explanation of origin. A restricted range may reflect local speciation, limits to dispersal, or survival after extinction elsewhere. Nor does endemism by itself imply rarity or low local density: a common organism can be geographically restricted. This is the geographic use of the term; epidemiological endemicity concerns a different kind of persistence.
The silicon cycle is the movement and transformation of silicon among rocks, dissolved compounds, living organisms and sediments. In the ocean, diatoms take up dissolved silicic acid to construct silica cell walls. After death, their material can sink, dissolve and return silicon to the dissolved pool, or be retained in sediments.[ref]
Accelerated dissolution of diatom silica by marine bacterial assemblages by Kay D. Bidle and Farooq Azam. Introduction: diatom demand, sinking biogenic silica and dissolution
Kay D. Bidle and Farooq Azam compared diatom-silica dissolution with marine bacterial processing. Faster dissolution associated with removal of the organic covering showed that recycling depends on the particle's biological coating as well as its mineral content. Microbial decomposition can thus change how rapidly a mineral nutrient becomes available again.[ref]
Pinned article: Introduction to the OurBigBook Project
Welcome to the OurBigBook Project! Our goal is to create the perfect publishing platform for STEM subjects, and get university-level students to write the best free STEM tutorials ever.
Everyone is welcome to create an account and play with the site: ourbigbook.com/go/register. We belive that students themselves can write amazing tutorials, but teachers are welcome too. You can write about anything you want, it doesn't have to be STEM or even educational. Silly test content is very welcome and you won't be penalized in any way. Just keep it legal!
Intro to OurBigBook
. Source. We have two killer features:
- topics: topics group articles by different users with the same title, e.g. here is the topic for the "Fundamental Theorem of Calculus" ourbigbook.com/go/topic/fundamental-theorem-of-calculusArticles of different users are sorted by upvote within each article page. This feature is a bit like:
- a Wikipedia where each user can have their own version of each article
- a Q&A website like Stack Overflow, where multiple people can give their views on a given topic, and the best ones are sorted by upvote. Except you don't need to wait for someone to ask first, and any topic goes, no matter how narrow or broad
This feature makes it possible for readers to find better explanations of any topic created by other writers. And it allows writers to create an explanation in a place that readers might actually find it.Figure 1. Screenshot of the "Derivative" topic page. View it live at: ourbigbook.com/go/topic/derivativeVideo 2. OurBigBook Web topics demo. Source. - local editing: you can store all your personal knowledge base content locally in a plaintext markup format that can be edited locally and published either:This way you can be sure that even if OurBigBook.com were to go down one day (which we have no plans to do as it is quite cheap to host!), your content will still be perfectly readable as a static site.
- to OurBigBook.com to get awesome multi-user features like topics and likes
- as HTML files to a static website, which you can host yourself for free on many external providers like GitHub Pages, and remain in full control
Figure 2. You can publish local OurBigBook lightweight markup files to either OurBigBook.com or as a static website.Figure 3. Visual Studio Code extension installation.Figure 5. . You can also edit articles on the Web editor without installing anything locally. Video 3. Edit locally and publish demo. Source. This shows editing OurBigBook Markup and publishing it using the Visual Studio Code extension. - Infinitely deep tables of contents:
All our software is open source and hosted at: github.com/ourbigbook/ourbigbook
Further documentation can be found at: docs.ourbigbook.com
Feel free to reach our to us for any help or suggestions: docs.ourbigbook.com/#contact





