Take from the downward vertical. Under the conventional light-rod idealization, only the endpoint point mass contributes appreciably. Its speed is , and its gravitational potential energy is . Therefore
An additive constant in the potential energy has no effect on the Euler-Lagrange equation.
Rod-mass qualification: “thin” and “uniform” do not imply negligible mass. If the uniform rod has a finite unspecified mass , its pivot moment of inertia is and its centre of mass lies from the pivot. For a pendulum with a uniform rod and an endpoint mass, the general answer is
This formula covers either convention without inventing a rod mass. A result involving only the specified uses unless an additional relation for is stated.
For , retain the ratio until a further limit is specified. Since , the leading expression from a is
For an infinitely heavy target at fixed incident energy, and : the projectile reverses with negligible target recoil energy. If the incident particle is ultrarelativistic even relative to the target, , the same leading expression instead gives . The mass hierarchy alone does not justify replacing by zero.
With and , one also has . The denominator in a is then dominated by , and the numerator by :
This residual total energy is still much larger than the incident particle's rest energy , but is a small fraction of its incident energy . The target acquires most of the available energy in this high-energy, heavy-projectile limit.
Launch and arrival occur on the capsule's own worldline, so its clock measures the proper time. In the ship frame its Lorentz factor is ; therefore
This uses the station-frame distance convention stated in i. With a one-light-day distance in the ship frame instead, it becomes . The uncertainty is a distance-frame convention in the wording, not a missing figure or an unanswered mathematical part.
Interpret the one-light-day separation as measured in the station frame at capsule launch, and retain the ship's initial inertial rest frame until reception at the station. The phrase does not explicitly name a frame; an alternative is given below. The ship-frame simultaneous separation is . The capsule moves at towards a station approaching at , so their separation decreases at in this frame. This is a separation rate, not either object's speed. Hence the elapsed ship-frame coordinate time is
It is the interval assigned using synchronized clocks in the ship frame to the launch and remote arrival. A single onboard clock does not directly mark the remote arrival event; observing its arrival signal would add a light-travel delay. If the stated one-light-day separation were instead measured in the ship frame, the answer would be .
In vacuum the electron-flavour survival probability depends only on and the mass-squared differences. Complex conjugation of the lepton mixing matrix therefore leaves it unchanged:
Thus a reactor disappearance measurement cannot search for the intrinsic CP violation phase in the standard three-neutrino model. Sensitivity to that phase calls for suitable appearance channels and, usually, comparison of neutrino and antineutrino beams. Matter can produce differences between propagation of neutrinos and antineutrinos; these are not by themselves intrinsic CP violation, and are small for the proposed short reactor baseline.
The relevant resolution condition is on the oscillation phase, not solely on which mixing angle is being measured. Since ,
At the same medium baseline, the fast -dependent ripples have phases about times larger than the slow component. Resolving those ripples therefore requires a much better fractional energy resolution. At 47 km, ; avoiding substantial phase smearing requires a resolution appreciably better than .
However, a short-baseline experiment near 1.24 km and a experiment near 46.5 km each operate near their relevant first maximum, . Their intrinsic fractional phase-resolution requirements are then comparable. The smaller disappearance amplitude demands careful relative calibration and background control, but it does not by itself impose a universally finer energy resolution. The proposal is conditional on baseline and analysis, rather than a general requirement.
A Positron signal is correct for the reactor's antineutrinos, through inverse beta decay,
A true electron neutrino charged current interaction instead produces an electron, for example . This corrects the source's loose use of “neutrino” for the reactor beam.
After slowing, the Positron annihilates with an electron, generally producing two keV photons. The prompt visible energy includes both the Positron kinetic energy and annihilation energy; neglecting the small neutron recoil,
A delayed neutron capture supplies a powerful coincidence tag. Detecting only two annihilation photons discards useful prompt energy and does not uniquely identify the charged current event.
The radiation length is the characteristic length for high-energy electron energy loss by bremsstrahlung; smaller means more radiative loss for the same traversed thickness. To limit that loss, minimize , choosing less material or a larger , rather than minimizing itself. At reactor Positron energies of a few MeV, ionization and subsequent annihilation matter more than high-energy bremsstrahlung. A sufficiently large scintillation counter measures the deposited energy, so containment of the Positron and annihilation photons, light yield and calibration are the relevant design issues.[ref]
A fission reactor supplies predominantly electron antineutrinos, with typical energies of a few MeV. Even if they oscillate to muon antineutrinos, producing a real muon through a charged current requires roughly the muon rest energy, over MeV for a free nucleon target. For example,
Thus a muon spectrometer cannot observe this appearance channel from a reactor. Measure electron antineutrino disappearance instead, most commonly through inverse beta decay, , using the prompt Positron and delayed neutron signal.
Matched near and far particle detectors are a good design. A near particle detector, close enough that the fast oscillation phase is small, measures the unoscillated reactor spectrum and normalization. A far particle detector near the first fast maximum measures the disappearance. Their appropriately geometry-corrected ratio cancels much of the uncertain reactor flux and common cross section and detection efficiency. Relative calibration, different backgrounds, multiple reactor distances and any residual near-site oscillation still need treatment. The near site should retain enough shielding to suppress cosmic backgrounds.[ref]
For a rate measurement of the small mixing angle , choose the first fast disappearance maximum,
A 47 km baseline instead lies near the slow oscillation maximum associated with . Its much lower flux, approximately falling as , and the many fast oscillations washed out by a reactor's broad energy spectrum make it a poor choice for this simple design. A medium-baseline spectral experiment can still constrain neutrino oscillation parameters if it has enough events and resolution; 47 km is not intrinsically useless, but it is not the optimal short-baseline rate experiment. In a, also affects the slow envelope through , so the sensitivity there is not identically zero.
The magnetic bending angle is . For a momentum estimate based on this angle, propagation of uncertainty gives . Comparing the total Multiple Coulomb scattering angle with the bend therefore gives the commonly intended characteristic estimate
Its independence of is the key result for relativistic particles: the scattering angle and magnetic bend both scale as .
A precise standard deviation requires specifying how tracks are measured. If is obtained from independently measured entrance and exit directions and all the material lies between them, the bending-plane projected root mean square is . For that estimator the equality is
A three-point sagitta fit weights scatter positions differently again. The paper does not specify these measurement details, so it fixes the scaling and characteristic estimate, but not one universal geometric coefficient for all track fits.
For a thickness with number density of scattering centres, the mean count is . Using the total cross section in i and the variance addition in ii,
Thus
The stated assumptions make the prefactor independent of and approximately independent of . The lower-cutoff factors cancel except inside the slowly varying logarithm. Treating as a Poisson random variable rather than a fixed count gives the same result after replacing by its mean.
Let . The supplied second moment gives the single-scatter root mean square angle
For independent scatters with uniform azimuth, the small angular-deflection vectors have zero mean. Their cross terms average to zero, so their variances add. After scatters,
This is the root mean square magnitude of the two-dimensional angular deflection. Its projection into one specified plane has a variance smaller by a factor of two, hence a root mean square smaller by .
For azimuthally symmetric Rutherford scattering, integrate over the solid angle, . Substituting gives , so
The small lower cutoff dominates when and . Using , the leading total cross section is
A nonzero cutoff is essential: the unscreened forward cross section otherwise diverges.
The sagitta is the maximum distance between the circular track and its chord. The perpendicular bisector of a chord of length gives a right triangle with hypotenuse and sides and . Hence
At fixed electric charge, magnetic field and lever arm, , so differentiation and propagation of uncertainty give
Thus a fixed spatial measurement uncertainty produces a relative momentum uncertainty growing linearly with . If momentum is expressed in , in tesla, in metres and , restore the usual conversion .
The Lorentz force is . Because it is perpendicular to the velocity, it changes the direction of momentum without changing its magnitude. For a charged particle in a uniform magnetic field, the radius of curvature is . Over the short track, the bending angle is . Equivalently, integrate the force for a time while neglecting the small rotation in its direction. The magnitude of the acquired momentum component perpendicular to the incident direction is
Its direction follows ; a signed component can therefore be written after fixing an oriented bending axis. Chord length and arc length agree at this order in .
For the selected muon channel, finite curvature resolution in the magnetic tracking system broadens the reconstructed transverse momentum spectrum. A high- track has small sagitta, so spatial measurement errors, alignment errors and magnetic-field calibration errors become important; at high momentum an approximately fixed uncertainty in gives . Multiple Coulomb scattering contributes at lower momenta. If the transverse mass is fitted, finite hadronic-recoil resolution additionally smears the inferred missing transverse momentum. These are experimental effects, distinct from the physical recoil and width in ii.
Choose . Important backgrounds include quantum chromodynamics production of heavy-flavour hadrons with semileptonic decays, in-flight pion or kaon decays, and hadrons penetrating the calorimeters. These generally have accompanying jet activity; semileptonic decays can contain real neutrinos, while jet mismeasurement can fake missing transverse momentum. Heavy-flavour tracks can originate at a displaced decay vertex. Require a high- isolated muon, agreement between inner tracking and the external muon system, and substantial missing transverse momentum inconsistent with detector noise or a mismeasured jet.
The genuine electroweak backgrounds include with one muon lost and . Veto a second reconstructed opposite-sign muon and use the dimuon invariant mass when both are present to reject the Z boson channel. The tau-mediated spectrum is softer and contains extra missing particles; template fits and control samples estimate its residual contribution. Detector acceptance determines how much of the lost-muon background survives.