Signal-subspace preservation for several spectral amplitudes requires a compression to retain every noise-weighted mean direction relevant to those amplitudes. Let have mean , fixed positive-definite noise covariance , and a full-column-rank shape matrix . Compress it as , with full row rank. The original and compressed amplitude-information matrices are
For Gaussian noise these are Fisher information matrices. Without that distributional assumption, they still describe the corresponding known-covariance linear estimation problem.
Whiten the shapes as and put . The orthogonal projection onto the row space of is , giving
This difference is positive semidefinite. It vanishes exactly when every column of lies in that row space, equivalently
Thus preserving one selected shape does not establish preservation of the whole signal subspace. Linear covariance propagation supplies for the compressed observations.[ref]
For an original example, take and shape columns and . Then . Choosing
gives and , hence . Keeping only the first compressed row retains information2 for the first amplitude but destroys sensitivity to the second. An unweighted first row would instead reduce the first information entry to1.8.
At least independent compressed directions are needed to preserve independent shape amplitudes. One construction is , whose compressed signal has mean and covariance . When is invertible, has mean and covariance . In the fixed-covariance Gaussian model, expanding the likelihood function shows that its parameter dependence is retained through .
Unknown nuisance shapes, changing covariance or additional spectral parameters can alter the subspace that needs preservation. The proof concerns the specified family of mean shapes and fixed noise model, rather than guaranteeing that one compression preserves every future spectral question.
Sign-sensitive measurements that resolve a covariance-axis ambiguity add an observable whose distribution changes when the fitted axis direction is reversed. In the global orientation ambiguity in a rank-one covariance fit, and give the same covariance. An independently calibrated signed projection can distinguish them.
Consider two candidates with an additional observation , where is known, has known positive sign and . Assume this calibration reading is independent of the covariance data conditional on the candidate. The Gaussian densities give
The normal density and cumulative distribution function used here are documented in the pinned numerical reference.[ref] The likelihood-ratio expression follows by expanding the two squared residuals.
For an original example, let , and observe . The log likelihood ratio is 16, strongly favoring the positive candidate under this stated model. With equal prior probabilities and equal decision costs, the sign-threshold decision has repeated-measurement error probability . This decision-error probability is different from assigning a posterior error probability to that one observed value.
A practical calibration applies a known signed perturbation and records the signed detector-response component. Reversing the applied perturbation checks readout polarity. A calibrated phase-sensitive readout can provide such a projection; measuring only noise covariance does not supply its sign.
The failure of sign recovery from magnitude-only calibration data is important. For symmetric Gaussian noise, has the same distribution under means and . If is orthogonal to the axis, then and even the signed reading adds no separation. If the amplitude sign itself is unknown, reversing both amplitude and axis preserves the mean. The additional measurement resolves the ambiguity only when its reference sign and response model are independently established.
Sill of a semivariogram 2026-10-05
The sill is the large-distance level of a semivariogram when that limit exists. For covariance tending to zero, the sill is the total marginal variance; a nugget plus a structured component has total sill . A nonzero constant covariance component is invisible to the semivariogram.
Simo Särkkä Created 2026-10-13 Updated 2026-11-05
Coauthor with Arno Solin of a textbook on applied stochastic differential equations. Its examples connect linear stochastic models with transition distributions and stationary covariances.[ref]
Simple kriging Created 2026-10-05 Updated 2026-10-18
Simple kriging assumes a known mean function. If and are known, center the observations, predict the residual, and add back the target mean:
For known zero mean, these reduce to and . Completing the covariance quadratic form gives
which proves minimum error variance among predictors of the form . No sum-to-one constraint is needed: the known mean already supplies the offset. In the exponential example from ordinary kriging, imposing known zero mean gives weights , prediction , and error variance . The smaller error variance uses additional knowledge of the mean; it is not a free improvement when the mean is unknown.
If has a joint multivariate normal distribution, the displayed prediction is exactly , and is its conditional variance. A conditional expectation minimizes mean squared error among all square-integrable functions of the observations. Without a joint multivariate normal distribution, simple kriging remains the best predictor in the specified affine class, but the conditional expectation may be nonlinear and its conditional variance may depend on . Thus Gaussian process regression and the second-moment kriging construction agree under these assumptions, while having different starting points.[ref]
Simple random walk on the integer line Created 2026-09-24 Updated 2026-10-14
A simple random walk on the integer line starts at and takes independent and identically distributed random variables as unit increments, with
The simple symmetric random walk has ; a biased random walk has . At or every step is deterministic, giving or respectively.
Count the rightward steps using indicator functions:
Thus the endpoint is a shifted and rescaled random variable with a binomial distribution. For a worked example, at the endpoint means exactly three rightward steps and one leftward step. There are possible orders, so its probability is , equal to in the fair case. More generally the binomial coefficient counts the orders, giving the exact probability mass function
In particular, the endpoint must have the same integer parity as : . For the support of a probability distribution is exactly . At only even integers in are reachable; at only odd integers are reachable. This restriction is easy to lose if one draws a smooth curve instead of discrete probability masses. The fair-walk counting argument is also presented in Grinstead and Snell, Introduction to Probability, section 12.1.
Figure 1.
Exact binomial endpoint probabilities for fair walks of 20 and 80 steps and a biased walk of 80 steps; only even endpoints are possible.
Details.
The endpoint identity and the binomial distribution give the expected value, variance, and standard deviation
A short direct check gives and , hence . Then apply linearity of expectation and the variance of a sum of independent random variables.
The absolute width and the width relative to the number of steps answer different questions. In the fair case the standard deviation grows from to , while shrinks from to . At , the standard deviation is , or times the fair width, and . Centering and dividing by each walk's own standard deviation gives, for ,
This rescaling equalizes the variances, not the entire probability distributions. The spacing between reachable endpoints is two, so its rescaled spacing is : approximately for the fair -step walk, for the fair -step walk, and for the biased -step walk.
The positions themselves are dependent. For , , where the second term is independent of . Their covariance is therefore
For example, in the fair case allows or , whereas allows or . Nevertheless the position process is a Markov chain: given its current position, the next fresh increment has no dependence on its past. Its transition probabilities are
These transition probabilities are the same at every time and every integer position: shifting both and by the same integer leaves unchanged. Thus the Markov property and independent increments coexist with dependent positions.
For independent -variate multivariate normal observations with unknown mean and unrestricted positive-definite covariance matrix, the centered scatter has rank at most . If it is singular, choose the mean to be the sample mean and shrink the covariance on a null direction of the scatter. The quadratic likelihood term stays fixed while the determinant tends to zero, so the density likelihood tends to infinity. Thus a nonsingular covariance maximum likelihood estimate exists only when the centered scatter is positive definite; for a nonsingular Gaussian population this occurs almost surely exactly when .
SLE4 coupling with a Gaussian free field Created 2026-10-07 Updated 2026-11-05
For a Gaussian free field with boundary heights and on the two sides of the starting point, its distinguished zero-height interface has chordal law. Conditional on an initial curve segment, the field is a zero-boundary field in the slit domain plus . Its mean bracket equals minus the variation of its conditional Green covariance. Subtracting the initial harmonic function gives the corresponding coupling to a zero-boundary field.
Spectral common-mode offset rejection is cancellation of an additive frequency-axis shift when the same shift enters two spectral estimates with equal sensitivity and the estimates are subtracted. It improves a frequency difference without establishing accurate absolute frequencies. The relevant measurement model must identify what is shared, and over which observations.
For true frequencies , write measured estimates as
The unknown common offset disappears exactly from
For independent residual errors of standard uncertainty , the difference still has standard uncertainty . Cancellation of is not cancellation of all measurement noise. With correlated residuals, the covariance term must be retained in uncertainty propagation.[ref]
An original example uses two spectral positions at and . An additive shift of gives measured positions and , with the same separation. A shared gain error is different: gives separation . Subtraction rejects the offset but retains the scale error.
The algebra generalizes to a contrast of several spectral positions. If and each contains the same additive , its contribution is . Thus weights satisfying reject that offset. Averaging positions with weights summing to one does not. This is an original linear-model derivation of the rejection condition, not a claim that every spectral estimator has this form.
Two failures of the ideal assumption are especially informative. With unequal spectral offset sensitivity, , subtraction leaves . If the offset drifts between observations, it instead leaves . For a stationary drift with variance and correlation at lag , this residual has variance
A common instrument or reference does not alone imply perfect cancellation at different times.
An apparatus-level check measures two stable reference features using the same acquisition and fitting pipeline, then deliberately shifts the assigned axis origin. Their separation should stay fixed under an additive reassignment; a scale change should alter it. Repeated reference observations test temporal drift and residual covariance. In two-dimensional infrared spectroscopy, this test concerns frequency-estimation errors; spectral diffusion also describes physical fluctuations and cannot be identified or removed merely by subtracting an instrumental offset.
Spectral-contrast conditioning in nail optics describes how measurement errors are amplified when thickness or tissue parameters are recovered from spectral differences. A model can be identifiable in exact arithmetic while its parameter estimates are too sensitive to small signal or calibration errors to be useful.
For the original simplified plate model with known coefficients and wavelength-independent effective reflectance , thickness is
Let each log signal have standard uncertainty and their correlation be . The first-order thickness uncertainty is
The covariance term belongs to the uncertainty calculation; treating every spectral error as independent can be misleading.[ref]
With stipulated and independent errors, coefficient differences and give thickness uncertainties about 0.0141 and 0.141 mm, respectively. A tenfold loss of spectral contrast produces tenfold error amplification. At the larger contrast and correlation 0.9, the modeled uncertainty is approximately 0.00447 mm. These are local model calculations, not validated precision claims for nail measurements.
Coefficient calibration also matters. If signal-ratio error and error are independent,
Collecting more signal averages does not eliminate the second term when the same uncertain calibration is reused.
Offset sensitivity of log-ratio nail models distinguishes error types. A common multiplicative factor cancels from ; a common additive offset generally does not cancel from . Background light or unseparated fluorescence can therefore bias an otherwise precise ratio. The primary nail-transmission experiment explicitly included a fluorescence correction.[ref]
Choose spectral channels using both sensitivity and a defensible optical model. A strong contrast is not sufficient if the assumed plate coefficients, collection geometry or underlying spectral behaviour are wrong.
Spectral density transformation under a linear filter Created 2026-10-07 Updated 2026-10-14
Filtering multiplies the time-series spectral density by the squared modulus of the frequency response. Insert the spectral integral into the covariance double sum and interchange sums using absolute summability of the filter. This holds even when the input covariances are not absolutely summable, provided the spectral measure has a density.
Stationary Gaussian density for a linear Fokker-Planck equation Created 2026-10-03 Updated 2026-11-05
For linear drift and constant symmetric positive-definite diffusion matrix , a zero-current stationary Gaussian obeys
This reversible solution exists when is symmetric positive definite. Its covariance satisfies the Continuous Lyapunov equation
Stationary Gaussian random field Created 2026-09-28 Updated 2026-11-05
A stationary Gaussian random field has Gaussian finite-dimensional distributions invariant under common spatial translations. Its mean is constant and its two-point covariance depends only on the separation of the points.
Stationary process Created 2026-09-28 Updated 2026-10-14
A stationary process, in the strict sense, has the same joint probability distribution after every common shift of its time indices. More precisely, for every positive integer , every choice of times , and every integer shift ,
Here equality means equality of probability distributions, not equality of realized observations. A sample path can fluctuate, stay positive for a while, or show accidental runs while its generating law remains stationary. Strong white noise is a basic example: shifting time preserves every joint law of its independent and identically distributed random variables.
The distinction between strict stationarity and weak stationarity is useful. The former preserves all finite joint laws; the latter preserves only the finite mean and covariance structure. Strict stationarity with finite second moments implies weak stationarity, but strict stationarity itself does not require finite variance. A Gaussian process with weak stationarity is also strictly stationary, because each of its finite-dimensional distributions, a joint normal distribution, is determined by its mean vector and covariance matrix.
Statistical dependence 2026-10-14
Two random variables are statistically dependent when their joint probability distribution differs from the product of their marginal probability distributions. Equivalently, some events determined by the two variables violate the product rule that defines independence. Nonzero covariance implies statistical dependence when the moments exist, but zero covariance does not in general imply independence.
This tensor integrates the local pressure tensor, where is the velocity covariance. Half its trace is the random kinetic energy. It enters the tensor virial theorem with coefficient one.
Stent recoil 2026-11-05
Stent recoil is a reduction in the diameter of an expanded vascular stent after the expanding load is removed. For a balloon-expandable device, the relevant acute comparison is commonly the diameter during balloon expansion against the diameter after balloon deflation. It is distinct from later biological tissue growth inside the treated segment.[ref]
Using matched diameter measurements during expansion and after release, define
The denominator is the expanded diameter. An original bench example with and gives . If the sections are circular, the corresponding area loss is
Diameter and area percentages should not be interchanged, and neither alone specifies the resulting change in blood flow.
The mechanical distinction is between permanent expansion and recoverable deformation. A loading–unloading test relates stent recoil to the device’s material response and geometry. Imaging should compare the same location along the device; averages can hide differences near its ends. The primary FDA engineering guidance consequently asks for diameter-specific measurements and attention to variation with length and position.[ref]
The ratio also has a useful measurement property. Multiplying both diameters by the same scale factor leaves unchanged, while an equal additive edge-location offset generally does not. For independent diameter standard uncertainties , first-order uncertainty propagation gives
With in the example, percentage points. Shared image-scale or fitting errors require a covariance term instead of the independent-error formula.[ref]
For this stochastic integral solves . The Itô product rule also gives . The process is centered Gaussian, with covariance , and has a continuous extension . Time reversal of a Brownian bridge proves endpoint continuity without assuming it at the start.
Subgrid-scale model 2026-11-05
A subgrid-scale model represents the influence of unresolved motion on the quantities retained in a large eddy simulation. Its need follows directly from the nonlinear velocity product in the Navier-Stokes equations: averaging a product generally differs from multiplying the averages.
Let a bar denote a spatial averaging filter. With constant mass density , constant kinematic viscosity , and a time-independent translation-invariant filter on an unbounded or periodic domain, filtering the incompressible momentum equation gives
where repeated indices use the Einstein summation convention, is pressure, and the subgrid-scale stress in this sign convention is
The assumed filter commutes with the displayed derivatives. The definition of is exact; a closure must approximate it using available resolved information.[ref]
For an elementary example, average two equally weighted values of one velocity component, and . The mean is zero but the mean square is , so the corresponding stress component is . A resolved mean alone has lost the information needed to reconstruct that covariance.
The Smagorinsky model closes the deviatoric part with an eddy viscosity:
where is the Kronecker delta, is the resolved strain-rate tensor, a dimensionless model coefficient and a characteristic filter width. The isotropic stress can be included in a modified pressure. This strain-dependent viscosity has its historical origin in Joseph Smagorinsky's atmospheric circulation modelling.[ref][ref]
For an incompressible flow, the model transfers resolved kinetic energy out at the rate per unit mass
A fixed nonnegative eddy viscosity therefore permits dissipation but excludes local turbulent backscatter. A dynamic subgrid-scale model can instead estimate its coefficient from resolved stresses at two filter levels. This addresses a modelling choice, rather than changing the exact definition of the unresolved stress.[ref]
Subgrid-scale stress 2026-11-05
The subgrid-scale stress records velocity-product information missing from a filtered velocity field. For constant mass density and a specified spatial averaging filter, use the convention
It enters the filtered momentum equation through . This has units of squared speed; multiplication by mass density gives units of mechanical stress. Some sources use the opposite stress sign, so the momentum equation fixes the convention.[ref]
For a normalized nonnegative kernel, define . Expanding the product gives
It is therefore a weighted covariance at the chosen point. For every real vector , , so the stress matrix is positive semidefinite. This argument depends on a nonnegative kernel; it cannot be applied unchanged to filters with negative weights.
For example, average equally weighted velocities and . The mean velocity vanishes but . With , . A zero mean has hidden nonzero motion.
The definition is exact. A subgrid-scale model instead approximates this tensor using available resolved data. In an incompressible flow, the isotropic part can be absorbed into a modified pressure; the remaining deviatoric stress controls the modeled directional transfer.