Optical trap Langevin calibration Created 2026-10-18 Updated 2026-10-20
Add the random thermal force to the deterministic optical trap relaxation time model. In one stationary coordinate of a harmonic optical trap, the overdamped Langevin equation is
Here is Gaussian white noise understood through its integrals, is the Dirac delta function, and is the linear friction coefficient. The covariance coefficient has units ; multiplying by , of units , gives squared force. This fluctuation-dissipation relation for a Langevin particle makes the stationary variance , consistent with the equipartition theorem. The solution is an Ornstein-Uhlenbeck process with autocovariance function
Indeed, at positive lag the noise has zero correlation with the initial position, so ; its initial value is . This supplies both a decay time and an amplitude, making a stronger calibration test than a position histogram alone.
Specify the Fourier transform convention before using a power spectral density. For frequency in hertz, define and the one-sided density for . Integration of the exponential gives
The position power spectral density has units ; its integral is a variance, not a standard deviation. At it is half its zero-frequency plateau. Angular frequency conventions require a corresponding conversion in both axis and integration measure. If with position sensitivity in , then in before independent detector noise is added.
For an original invented calibration example, choose , dynamic viscosity , , , and . The unbounded no-slip Stokes drag law gives
The corresponding voltage standard deviation is , and the position power spectral density plateau is , or in the detector. Recovering both and is an internal model check; actual agreement also tests the assumed temperature, drag and detector response.
Figure 1. . Original model calculations and seeded synthetic Ornstein-Uhlenbeck process samples; explicitly not measured data. The record is sampled at with no detector noise or exposure averaging. The dashed spectrum includes sampling aliases; the red continuous spectrum integrates to the exact equipartition theorem variance. The drag line is an exact steady-model prediction. Source. Details.
The generator uses the exact stationary update , with and independent standard normal random variables . For a demeaned block of samples and its unnormalized discrete Fourier transform , the two-sided periodogram is ; doubling positive bins except the zero and Nyquist endpoints gives a one-sided density. Summing those bins times returns the block mean square by discrete Parseval identity. Independent detector noise, finite exposure and aliasing would alter a measured spectrum and must enter a fit before interpreting .
Specify the radiation normalization first. Let be radiation energy density per ordinary frequency, with SI units . Then is the spontaneous emission rate per upper-state chemical atom, while and are the induced absorption and stimulated emission rates, evaluated at a sharp transition frequency. For a finite spectral line profile, replace by its profile-weighted average.
The Einstein coefficients obey
Here are the statistical weights of the two energy levels, and the field is unpolarized and isotropic. The units and physical dimensions are
The apparently time-independent dimension of follows because a per-hertz density includes an extra unit of time. If instead multiplies the mean intensity , use and . These distinct normalizations must not be mixed in the radiative transfer equation.
Pitch contour 2026-11-05
A pitch contour describes how perceived pitch varies over an utterance. For speech with voicing, a common measurable correlate is the fundamental frequency of vocal fold vibration. A rising estimated indicates increasing repetition rate; stretches without sufficiently periodic vibration need not have a meaningful estimate.[ref]
For an ideal periodic segment whose repetitions are separated by , . Detecting repetition at instead produces an erroneous 50 hertz estimate, illustrating why a visually smooth pitch contour can still contain an octave error. Noise, the analysis interval and the allowed frequency range affect the estimate. Current Praat documentation distinguishes methods intended for speech intonation from methods intended for other periodicity measurements.[ref]
A pitch contour is not the same as a formant contour: changing the fundamental frequency changes the repetition rate, whereas formants describe the resonant spectral structure shaped by the vocal tract.
Power broadening 2026-10-18
In the two-level saturation population model, and the population-difference reduction reach half their resonant values at . Their half width at half maximum is therefore and their full width at half maximum is in angular frequency, or in hertz. This is power broadening: stronger excitation addresses a wider range of detunings even though the lifetime has not changed.
Increasing improves the local population-difference reduction but broadens the response. From to , this reduction increases from to , while the width increases from to . The contrast approaches a limit and the width keeps growing. This single-atom width is not automatically the width of a velocity-averaged pump–probe feature.
For example, if the distribution of velocities is approximately constant across the narrow resonant classes, the population-only overlap integral contains two Lorentzian line shapes: a probe of half width and a pump hole of half width . Their centres in are separated by . The convolution of these profiles has half width in that separation, so its full width at half maximum as a function of is . Even this simplified pump–probe width differs from the single-atom power broadening formula. Finite Doppler broadening and coherent or multilevel effects require further analysis.
Power spectral density 2026-10-18
A power spectral density distributes the mean square of a signal over frequency. Its integral over the specified frequency domain gives that mean square. State whether the convention is one-sided or two-sided and whether frequency is measured in hertz or as angular frequency. For a zero-mean stationary signal, the mean square is its variance; spectral density of a stationary process gives the discrete-time convention.
Write an ideal point-transfer model using the Dirac delta function:
For this arrival stream with independent increments, distinct arrivals contribute the product of the means, which cancels when centering. The same-arrival term leaves the autocovariance
Its Fourier transform gives the two-sided power spectral density, while folding negative frequencies onto positive ones gives the one-sided convention:
These spectra describe , excluding the spectral line from the mean direct current. The amplitude spectral density is in ; it is not a root mean square electric current until a measurement signal bandwidth is specified. Approximate white noise requires frequencies low enough that the single-transfer pulse shape and any correlations can be neglected. Neither the ideal impulses nor a flat spectrum extending to infinity describe a real detector at every timescale.
All spectra above are per hertz, with in cycles per second. One possible angular frequency convention defines a density integrated using alone. Since , it has
Another common convention keeps the numerical density but integrates it with . State the integration measure as well as whether a spectrum is one-sided: a change of variable and a folding of signs are separate operations.
Model an ideal resistor of constant electrical resistance at uniform absolute temperature by its Thévenin equivalent: a zero-mean random voltage source in series with a noiseless . In the classical range its one-sided, open-circuit voltage power spectral density, per hertz, is
where is the Boltzmann constant. Thus a positive-frequency interval of width contributes to the mean square voltage. This is approximately white noise only where the electrical resistance is effectively constant and , with the Planck constant. The ideal constant spectrum cannot describe arbitrarily high frequencies.[ref]
For a real voltage, an equivalent two-sided power spectral density is over signed frequencies. With a real linear time-invariant system of frequency response , the same output mean square is
Angle brackets denote an expected value; for this zero-mean noise the mean square is its variance. Do not integrate over both signs of frequency: that counts the same fluctuations twice. All integrals here use frequency in hertz, not angular frequency . The amplitude spectral density is in , whereas the root mean square voltage requires a specified measurement signal bandwidth.
Choose a closed two-level system, equal stimulated absorption and emission strengths, a monochromatic pump, and no extra dephasing. Let be the lower and upper populations, and let spontaneous emission remove upper population at rate . In this convention the natural linewidth is full width at half maximum in angular frequency, its half width at half maximum is , and its full width at half maximum in hertz is . All below are angular detunings.
Let be the on-resonance saturation parameter. An effective stimulated transition rate that reproduces the monochromatic steady response is
Here describes each stimulated direction, while describes irreversible spontaneous emission. The rate equation gives the steady populations; it is not a description of transient Rabi oscillations. Setting gives
and the population difference relevant to net weak-probe photon absorption is
The pump depletes the lower population by , but reduces the population difference by : stimulated emission contributes as well as missing ground-state absorbers. On resonance, gives , , ; gives , , . As , the two populations approach , rather than producing a population inversion. Far off resonance, and .
For moving atoms use in these pump-prepared populations. A weak counterpropagating probe interrogates them near . A simple population-only approximation to its absorption coefficient averages the weak-probe Lorentzian line shape times over the Maxwell-Boltzmann velocity distribution. It neglects interference between the beams, changes of velocity during illumination, and multilevel optical pumping. Those restrictions matter for real alkali chemical atoms.
Weak-field Zeeman splitting Created 2026-10-18 Updated 2026-10-20
Use the leading nonrelativistic magnetic coupling for an electronic level with total angular momentum operator , and choose the axis along a uniform external magnetic field , . Write its magnetic quantum number as , so . There are possibilities from to . With Landé g-factor , the first-order shift is
Here is the magnitude of the electron electric charge, its mass, the Planck constant, and the Bohr magneton. Both and are dimensionless; with measured in tesla and in joules per tesla, is in joules. The photon frequency shift is in hertz, not angular frequency; indices denote upper and lower levels. NIST states this weak-field convention and its orbital/spin assumptions explicitly.[ref]
The sign follows directly from magnetic dipole potential energy. Within this electronic multiplet, the projected magnetic dipole moment is . Therefore has the displayed positive coefficient. Subtracting the shifts of the two levels and using photon energy gives the transition formula. For the orbital case, gives the same leading frequency spacing as the classical charged oscillator. This explains the historical sensitivity to charge divided by mass; the quantum state derivation here is modern.
“Weak” compares interaction energies: mixing with neighbouring fine structure levels must be small, so remains a useful quantum number. The formula keeps the term linear in and neglects quadratic shifts. It also omits hyperfine structure; if that is resolved and controls the coupling, the appropriate total electronic-plus-nuclear angular momentum and splitting factor must replace . Weak compared with fine structure does not automatically mean weak compared with hyperfine structure.