Rüchardt experiment Created 2026-10-14 Updated 2026-10-25
The Rüchardt experiment infers heat capacity ratio from the period of an oscillation of a piston supported by trapped gas. Use a vertical precision cylinder with a close-fitting movable piston, known moving mass , face area , trapped equilibrium volume , and local atmospheric pressure . With negligible static friction, force balance gives the absolute gas pressure , where is gravitational acceleration. Displace the piston slightly and release it: compression raises pressure, and expansion lowers it, producing a restoring force. The oscillation is a mechanical probe of thermal response, without separately measuring two heat inputs. [ref]
https://groups.ist.utl.pt/wwwelab/wiki/index.php?title=Determination_of_the_Adiabatic_Constant. Instituto Superior Técnico e-lab, Determination of the Adiabatic Constant: piston apparatus and period model
Let be upward displacement from equilibrium, so . For constant heat capacity ratio and a reversible adiabatic process, the net upward force, including the ambient load and weight, isThe linear approximation requires . Applying Newton's second law gives simple harmonic motion withHere is the undamped angular frequency and the undamped oscillation period, rather than temperature. Record repeated cycles, measure independently, and include all connected trapped volume. An illustrative model with , , , , and gives and . These stipulated values are not measurements.
In Shearwood and Sloan's implementation, piston-mounted magnets induce an electromotive force in a stationary coil through Faraday's law of induction; an oscilloscope records the signal. They observed faster oscillations at smaller trapped volume values and stronger damping at small cylinder volume values. The signal tracks velocity locally, so its amplitude is not directly piston displacement. Calibration also identified inlet dead space beyond the graduated cylinder volume. [ref]
https://arxiv.org/html/2209.03323v1. Chris Shearwood and Peter A. Sloan, The Rüchardt experiment revisited, §§3–4: signal, dead volume and observations
Repeat at smaller initial amplitudes to test the linear approximation, and compare several values. Heat transfer weakens the restoring force toward the isothermal process limit, biasing the inference toward . Check leakage through resting-piston drift and before-and-after trapped volume readings. For viscous damping with envelope , the measured angular frequency obeys ; this correction does not remove thermal leakage. Internal equilibration must be faster than an oscillation period, with heat transfer and leakage slow over a run. Large amplitude or sticking friction require a richer model. [ref]
Self-inductance Created 2026-10-06 Updated 2026-10-14
Self-inductance is inductance associated with a coil's own electric current, rather than magnetic flux supplied by another coil. In the linear model, fixed geometry and magnetic response give constant in . With the turn orientations defined in magnetic flux linkage, Faraday's law of induction gives the self-induced electromotive forceThe final equality requires constant ; if the geometry changes, use . The minus sign expresses Lenz's law: the induced electromotive force opposes the change in electric current. It does not always oppose the electric current itself. When positive electric current decreases, the induced electromotive force acts in its direction. [ref]
https://openstax.org/books/university-physics-volume-2/pages/14-2-self-inductance-and-inductors. OpenStax University Physics 2, §14.2: self-induced emf and its direction
.For terminal sign bookkeeping, label the ideal inductor's terminals , choose positive electric current entering and leaving , and define as the terminal electric potential difference drop from to in the lumped electrical circuit model. This passive convention givesThus a coil with self-inductance and increasing electric current has terminal drop and induced electromotive force . These signs describe the same process with different reference conventions. The RL circuit uses the terminal-drop convention throughout.
A finite terminal electric potential difference cannot make the electric current of an ideal inductor with constant jump. Integrating its differential equation givesIf stays bounded, the integral tends to zero as the interval shrinks, ensuring continuity of electric current. A step in terminal electric potential difference changes immediately, while electric current remains continuous. At constant electric current, the self-induced electromotive force is zero, although the inductor's magnetic energy can remain nonzero.
Surface impedance of a good conductor Created 2026-10-18 Updated 2026-10-20
For a wave penetrating a nonmagnetic good conductor in the direction with time convention , its wavenumber is , with skin depth . If , Faraday's law of induction gives . Thus the field ratio is , equal to the displayed expression. Magnetic and electric fields have equal exponential penetration lengths but a phasor phase difference ; has the positive phase relative to in this convention.
Vibrating-sample magnetometer 2026-10-18
A vibrating-sample magnetometer measures a specimen's magnetic dipole moment through the induced electromotive force as it moves relative to stationary pickup coils. Dividing that magnetic dipole moment by the specimen's independently determined volume gives its average magnetization.
In Simon Foner's 1959 apparatus, the specimen was weighed and glued to a mount. A loudspeaker drive moved it perpendicular to an applied uniform magnetic field between magnet poles; stationary coils detected the induced electromotive force. A reference magnet on the same vibrating assembly generated a second coil electromotive force. Adjusting the reference voltage divider to an electrical null compared the specimen signal with this reference. The measurement calibration substituted a magnetically saturated pure nickel sphere of known magnetic dipole moment; a specimen-removed reading corrected the mount's contribution. The calibrated signal inferred the specimen's magnetic dipole moment, not its local magnetization map. Measurement uncertainty in the standard, positioning, finite specimen size, coil noise, and mechanical coupling limited the inference.[ref]
The readout follows Faraday's law of induction. In a small-displacement model with constant projected magnetic dipole moment , let the pickup-coil magnetic flux linkage be and the specimen motion be . Here incorporates coil geometry and turn count, is the displacement amplitude, and is angular frequency. To first order in displacement, with the derivative at the mean position,This is an original idealized readout relation: a larger induced electromotive force can mean larger magnetic dipole moment, greater motion, or a changed coil position. A synchronously moving reference allows common motion factors to cancel in the ratio of induced electromotive forces. The measurement calibration and specimen-removed control are therefore integral to the measurement. A single amplitude reading cannot by itself distinguish microscopic alignment from a change in individual magnetic dipole moments.