Stern-Gerlach expectation estimation 2026-10-14
A concrete idealized implementation uses a Stern-Gerlach experiment twice: a preparation filter along passes only its plus spin channel, and a analyzer resolves both output channels for many fresh atoms. This prepares the spin one-half along an axis state . The authored apparatus description uses slit collimation, a nonuniform magnetic field with a pointed pole, and counters at the separated outputs.[ref]
Chapter 5: Spin One. The Feynman Lectures on Physics, Volume III, Chapter 5: Spin One, §5–1, figure 5–1 and the paragraph proposing output counters; §5–4, slit diffraction and internal-state limitations
The two-channel spin one-half preparation and analyzer are described separately; the source's recombining “improved” apparatus is explicitly idealized, so the setup here is a proposed estimation model, not a report of observed counts.[ref]Count every accepted analyzer event in its calibrated or channel and compute from the count difference. The magnetic field gradient separates trajectories through their magnetic moments; calibrated channel labels convert positions into spin eigenvalues. The readout is a population imbalance, not an intermediate trajectory carrying spin . Beam position also depends on flight time and field geometry, so averaging raw positions alone does not establish a calibrated spin expectation value.
As controls, feed known and preparations to check the channel assignment and leakage, hold the analyzer axis fixed, and repeat short blocks to check preparation drift. Measure background counts and relative channel efficiencies. With efficiencies and and negligible background, the detected plus fraction isUnequal efficiencies bias the naive sample mean, even for arbitrarily many counts. For example, , , and give detected fraction and naive mean , rather than . Background, overlapping beams, detector saturation, angle misalignment, unwanted internal states, and preparation correlations require a better measurement in quantum mechanics model. Increasing only reduces the independent sampling contribution; it cannot remove these systematic errors. The selected preparation beam is the population being estimated, so losses in preparing it must be distinguished from losses in reading its two outcomes.
Stern-Gerlach experiment 2026-10-14
A Stern-Gerlach experiment separates atomic beams according to a component of their magnetic moment in a nonuniform magnetic field. For an appropriate two-state spin system, calibrated outputs distinguish the two spin eigenvalues; Stern-Gerlach expectation estimation explains how repeated fresh preparations turn channel counts into an expectation value.