Equipartition theorem Created 2026-09-24 Updated 2026-10-20
The equipartition theorem says that each independent quadratic term in a Hamiltonian described by classical mechanics has mean energy in a canonical ensemble. Here is the Boltzmann constant and the absolute temperature. Count terms in the energy, rather than vaguely counting everything that can move: one harmonic oscillator has one position degree of freedom but TWO quadratic terms, one in momentum and one in displacement.
A precise sufficient setting is with , where is one of the canonical variables, denotes all remaining variables, and the phase space integration measure factors as . The range of is the whole real line, independently of ; there is no constraint coupling its allowed values to other variables. The partition function must be finite, and the relevant expected values must exist. The Boltzmann factor then givesThe probability density function is a normal distribution with variance . A larger coefficient narrows the fluctuations enough to cancel its greater energy cost. This is why the mean contribution is independent of mass or spring constant.[ref]
For a proof outline, the one-variable Gaussian integral is , so . More generally, integration by parts in a canonical variable gives when its boundary term vanishes and the integrals converge. For this is twice its mean energy. At a finite hard boundary the boundary term need not vanish; hard-wall correction to harmonic equipartition illustrates the resulting departure. A constraint, a nonquadratic potential energy, or a noncanonical integration measure therefore requires its own calculation. The theorem is an ensemble average, not equality of instantaneous energies, and applying it to a recorded trajectory requires equilibration and sufficient sampling.
For a classical one-dimensional harmonic oscillator, with positive mass and spring constant ,The origin is the equilibrium position. Its heat capacity is at fixed , not . Although the two mean energies agree, their measured amplitudes do not: and . In a harmonic optical trap, the position measurement observes the potential energy contribution; it does not measure both contributions by observing alone.[ref]
For particles in a three-dimensional classical monatomic gas, neglect interactions and thermally accessible internal excitations. Its three translational momentum terms give internal energy , heat capacity at constant volume , and heat capacity at constant pressure . Per mole, replace by the molar gas constant . For example, using stipulated , the molar heat capacity at fixed volume is . These results assume a dilute, nonrelativistic ideal gas with classical translational statistics, rather than a quantum degeneracy regime.
For an ideal gas of diatomic molecules, modeled as two chemical atoms with a bond, there are three translational quadratic terms, two accessible rotational kinetic energy terms for changes of bond orientation, and one bond-stretching harmonic oscillator with two quadratic terms. Rotation about the bond axis is not an additional active mode in this linear-molecule model. The three familiar limits of heat capacity at constant volume areCorresponding molar heat capacities are , and . Counting the stretching harmonic oscillator only once as would give the wrong last value.[ref]
The frozen regimes require quantum mechanics. In the simple molecular rotation model, with state degeneracy , , and moment of inertia . For the bond-stretching quantum harmonic oscillator, with angular frequency and from the Planck constant. When , the three limits above correspond to , , and , provided translational motion remains classical. They are smooth crossovers, not abrupt switches. Real molecules can have different allowed rotational populations; at high temperature, thermal dissociation, internal excitations and nonharmonic bond motion can invalidate the fixed-molecule model before its last limit is reached.[ref]
3 Quantum Gases. §3.4
For a quantum harmonic oscillator with fixed , put . Its exact mean energy and heat capacity areAt , the mean energy approaches and approaches . At , thermal excitation is exponentially suppressed and tends to zero, although the zero-point energy survives. Frozen thus means little thermal response, not zero motion or zero energy.[ref]
A motivating measurement is thermal calibration of an optical trap. A focused laser through a microscope objective confines a bead in water; imaging or a quadrant photodetector records a position time series. Gieseler and colleagues describe a polystyrene bead of radius at , a trapping laser, and photodetector acquisition at . Their recorded bead continues undergoing Brownian motion; higher trapping power produces a narrower equilibrium position distribution. Infer the centered variance, not a squared distance from an arbitrary camera origin:The normal distribution position histogram and agreement with dynamical calibration methods support the local harmonic optical trap interpretation. For a stipulated example, and imply . This calculated scale is not an experimental reading.[ref]
Position calibration is essential: if detector output has conversion , its physical variance is . An unknown scale cannot be determined together with from that one variance. A complementary calibration demonstrated by Tolić-Nørrelykke and colleagues combines the power spectrum of thermal motion with the bead response to known sinusoidal motion of a translation stage. The driven response supplies an additional length scale, and their method does not require bead size, liquid dynamic viscosity or wall distance as inputs. It still uses a thermal dynamical model; agreement between methods is a consistency check, not a theory-free proof of equipartition theorem.[ref]
The readout itself can hide fluctuations. Wong and Halvorsen used a optical trap and adjustable-exposure CCD imaging of a bead in water. They varied exposure and trapping power, held the bead away from the nearest wall, adjusted illumination to maintain comparable images, and measured tracking noise using a stuck bead. The measured variance fell as exposure increased; corrected results agreed with their time-averaging model. For a stationary overdamped harmonic optical trap, with optical trap relaxation time , an exposure of length measures . Its ideal noise-free variance isFor , : using the blurred variance in the uncorrected formula overestimates by . At , the calculated factor is . Additive tracking noise instead raises the measured variance and biases the inferred downward if left uncorrected.[ref]
Useful controls are to record over many optical trap relaxation times, compare blocks for drift, calibrate the position scale, measure fixed-bead noise, vary exposure, and check the position histogram for departures from a normal distribution. A sparse sequence of accurate instantaneous positions can estimate an equilibrium variance; a long exposure averages away motion even if many frames are collected. Flow, appreciable laser heating, escape from the harmonic region or nonconservative forces can break the assumed thermal equilibrium. Inferring by imposing equipartition theorem is a calibration, whereas testing the relation requires an independently established stiffness and position scale. The beautiful practical connection is that microscopic randomness can set a force scale: once calibrated, a small constant applied force displaces the mean by . The same quadratic-term counting predicts macroscopic heat capacity and makes microscopic fluctuations useful measurements.
Heat capacity ratio 2026-10-14
The heat capacity ratio compares heat capacity at constant pressure with heat capacity at constant volume at the same equilibrium state and fixed composition:Here refer to the whole sample, in ; molar heat capacities and are per mole; specific heat capacities and are per unit mass. The amount of substance or mass cancels only when both capacities use the same normalization. Thus heat capacity ratio is dimensionless and independent of sample size. For a fixed-composition ideal gas with positive finite , Mayer's relation giveswhere is the molar gas constant. More ways to store internal energy make a given temperature increase require more heat, bringing heat capacity ratio closer to unity. [ref]
https://web.mit.edu/16.unified/www/FALL/thermodynamics/notes/node18.html. MIT Unified Engineering, Specific heats: definitions and ideal-gas relations
The equipartition theorem predicts when independent quadratic terms in molecular energy are thermally active and their number stays fixed; consequently . A classical monatomic gas with no appreciable electronic excitation has , giving and . For an ideal gas of diatomic molecules with three translational and two rotational terms active, but its vibrational normal mode effectively frozen, gives and . A fully classical harmonic vibration adds both kinetic energy and potential energy, giving and . These are model regimes, not universal constants of every gas: rotational freezing, electronic excitation, and changing composition invalidate the simple count.[ref]
The mechanical significance of heat capacity ratio follows from the first law of thermodynamics. For a fixed amount of ideal gas in a reversible adiabatic process, . Combining this with the ideal gas law gives the local relationThe partial derivative holds at fixed entropy and composition even when heat capacity ratio varies with temperature. The finite-path formulas and require the additional approximation of constant heat capacity ratio. A rapid compression also needs internal equilibration to approximate this path; rapid motion alone does not ensure reversibility. The same local response gives isentropic compressibility and, for small sound disturbances in this ideal gas regime, speed of sound , where is mass density. Thus thermal storage controls mechanical stiffness, sound propagation and the measurements in Rüchardt experiment and Clément-Desormes experiment.
Internal energy Created 2026-09-24 Updated 2026-10-18
Internal energy is the energy stored in the microscopic degrees of freedom of a thermodynamic system: random molecular kinetic energy, internal molecular excitations, and interaction potential energy. Its value requires a specified system and an energy reference. In thermodynamic equilibrium, internal energy is a state function; it records the present state, without remembering whether a previous change came from stirring, compression or heat transfer. This makes internal energy the common accounting quantity connecting mechanical experiments to thermal ones.[ref]
Heat and work describe energy crossing the system boundary during a process. They are not separately stored contents of the system. For a closed system whose bulk kinetic energy and external potential energy have unchanged endpoint values, the first law of thermodynamics givesHere is positive for incoming heat, and is positive for net work done on the system. Two routes between the same equilibrium states have the same , although their heat and work can differ. The infinitesimal notation distinguishes a state function change from path-dependent transfers.[ref]
For a calculated example, take one mole of a classical monatomic gas in the ideal gas regime, at fixed volume, from to . With stipulated molar gas constant , its internal energy change is . A purely thermal route supplies with . An ideal insulated stirring route supplies with , measured between equilibrium endpoints after the motion dies away. The same stored increment has two different transfer histories; neither history defines a separate kind of stored energy.
The familiar internal energy of an ideal gas is a useful special case. Neglect intermolecular interactions, hold the amount of substance and composition fixed, and suppose that independent quadratic terms per particle obey the classical equipartition theorem. Choosing the constant reference contribution as zero givesHere is absolute temperature, is the molar gas constant, and is the whole sample's heat capacity at constant volume. A monatomic gas has translational terms. A rigid diatomic molecule has when its two rotational terms are active and vibration is frozen; activating one harmonic oscillator vibration adds two terms, one kinetic energy and one potential energy, giving . The counting is of quadratic contributions, so a vibrational coordinate is not just one contribution.[ref]
This constant- formula applies only over a regime with those same active terms, classical translational statistics, nonrelativistic motion and unchanged composition. Quantum freezing, quantum degeneracy, chemical reactions or appreciable intermolecular interactions invalidate that simple counting. More generally, at fixed amount and composition an ideal gas can still have with varying heat capacity at constant volume, so use . A nonzero constant reference adds to without altering .
Nonrelativistic equilibrium number density Created 2026-09-24 Updated 2026-09-24
Thermal de Broglie wavelength 2026-10-14