Albert A. Michelson Created 2026-10-24 Updated 2026-10-31
A physicist.[ref]
https://www.nasonline.org/wp-content/uploads/2024/06/michelson-a-a.pdf. Independent biographical identity and professional specialization
The Michelson interferometer turns a change in an optical path into a shift of interference fringes. Controlling the returning beams and counting the shifts can connect very small distances to a wavelength.
Portrait of Albert A. Michelson
. Moffett Studio; The World's Work 41 (1921), p. 420. Commons PD-US claim based on expired protection / pre-1931 publication; status outside the US may differ., via Wikimedia Commons. Source. Beam splitter Created 2026-10-05 Updated 2026-10-14
A beam splitter is an optical instrument that routes an incident beam of light into transmitted and reflected beams. It also combines incident complex amplitudes: two inputs can contribute to the same output. A common geometry has four optical ports, with two chosen as inputs and two as outputs. A beam splitter changes the field; a photodetector supplies a measurement.[ref]
Photon quantum mechanics and beam splitters by Charles H. Holbrow and others. Photon quantum mechanics and beam splitters, §IV, printed p. 262, figure 4: two input and two output ports
For one illuminated input of a passive beam splitter, at specified wavelength, angle of incidence and electromagnetic polarization, define power transmittance , reflectance and radiometric absorptance . In steady operation, with no gain or other source, no net stored energy change, and all escaping light included in the transmitted or reflected collection,This is conservation of energy divided by incident power. If and count only the intended output beams, include a separate scattered or otherwise uncollected fraction : then . Missing output power need not be wave absorption. For an original specified example, , , and give transmitted, reflected and absorbed; these are assumed values, not measurements.
A 50:50 beam splitter specifies equal output powers for one input, not equal complex amplitudes without a relative wave phase. Recombination needs the beam splitter scattering matrix, including its wave phases. A nonpolarizing beam splitter approximately divides both orthogonal linear polarizations in the same power ratio over its specified operating range; a polarizing beam splitter deliberately routes the two differently.
The useful surprise is that the same component divides power with one input and steers power by wave interference with two inputs. In a Michelson interferometer or Mach-Zehnder interferometer, mirror motion changes relative wave phase, turning a small change in optical path length into a measurable change in output power.
Coherent beam splitter recombination 2026-10-14
Suppose the two input beams share frequency, electromagnetic polarization and overlapping transverse profiles at each output, with stable relative wave phase during the photodetector's averaging interval. For the ideal beam splitter scattering matrix above, expanding the squared complex amplitudes givesThe imaginary part terms describe wave interference. Applying the single-input power split to each input separately and adding the results would discard these terms. Their opposite signs ensure : conservation of energy survives even when one output is dark.
For an original example, let , and . Then and :
| Relative input wave phase | Output power | Output power |
|---|---|---|
At , makes and ; at the dark output swaps. Thus the two inputs can feed all their combined power into one output without gain. At zero relative input wave phase, the splitter's own relative wave phase leaves the contributions in quadrature, so neither output is dark.
Relative input wave phase redirects the combined power of two coherent beams
. Original ideal-model curves for , and . Output powers are normalized by one input's power ; their sum is always . Markers show the three worked cases. These are calculated curves, not measured data. Details.For fluctuating fields, average the cross term as . It vanishes for mutually uncorrelated inputs, making the independent power-splitting rule valid for the averaged output. Partial first-order optical coherence reduces it. Orthogonal linear polarizations eliminate the cross term in a polarization-insensitive power readout, and spatial mismatch reduces the overlap. Detector averaging can also erase rapid relative wave phase changes. A fixed relation between two inputs can be prepared by splitting one laser beam and recombining the two arms.
An actual teaching protocol in Michelson Interferometer & Precision Wavelength Measurement — Week 1, University of Colorado Boulder, §§4–6, starts with an ideal-model prediction, then builds a Michelson interferometer using a helium-neon laser, a nonpolarizing beam splitter, adjustable mirrors, a micrometer translation stage and a photodetector. Steering mirrors align beam overlap at near and far planes; far-plane interference fringes refine alignment. Moving the arm mirror changes the returning relative wave phase; detector voltage is watched with a live acquisition display or oscilloscope. The guide compares measured arm powers with 50:50 splitting and asks for a revised field model. It tests electromagnetic polarization dependence, optionally changing one arm with a quarter-wave plate, and estimates noise from repeated readings at fixed mirror position. These controls test whether fringe changes reflect coherent recombination rather than splitter imbalance or misalignment. The guide supplies a protocol, not a numerical dataset. Its detector noise, imperfect overlap and electromagnetic polarization mismatch limit displacement inference.[ref]
Additional background subtraction controls follow from the field model: block both arms to record the detector offset and ambient light, then unblock each arm separately to establish its detected power at fixed gain. With both open, scan the mirror and compare extrema after subtracting that background. Keep the detector below saturation and repeat the scan to check drift. A changing signal alone cannot distinguish source optical coherence from motion or changing overlap. For a vacuum round trip, a mirror displacement changes relative wave phase by ; the useful signal is its modulation after detection, not an optical-frequency oscillation that the detector must resolve.
Changing both arms of a balanced Michelson interferometer by the same length changes the common phase of both returning fields. Their relative phase and detector intensity remain unchanged at every frequency. Thus balanced interference cannot select a minimum positive common arm length.
A Michelson interferometer mirror displacement changes round-trip optical path difference by , giving delay . An interferogram recorded over a finite delay range is multiplied by a window; the recovered spectrum is the true spectrum convolved with that window's Fourier transform. Its characteristic frequency resolution scales inversely with delay range. Consequently a mirror travel range gives and . Numerical width factors depend on the scan definition, window and resolution criterion; the inverse-travel scaling does not.
Division of amplitude 2026-10-18
In division of amplitude, a partially reflecting interface sends parts of the same incident wavefront into separate paths that are later recombined. A Michelson interferometer is an example. The resulting interference visibility depends on relative optical path length, polarization of waves, intensity balance and optical coherence.
Hanbury Brown and Twiss effect 2026-10-18
Robert Hanbury Brown and Richard Q. Twiss sought angular sizes through correlations of detected light intensities. Their method multiplies detector outputs after detection, whereas a Michelson interferometer combines fields before detection.[ref]
Correlation between Photons in two Coherent Beams of Light by Robert Hanbury Brown and Richard Quentin Twiss. 1956, Nature 177, pp. 27–29, accessible opening paragraphs
A monochromatic discharge source illuminated a half-silvered beam splitter and two photodetectors. The averaged current product showed an excess near coincidence. Moving one detector introduced a delay that removed it, supplying a control. Slow response weakened the peak. This photon bunching is compatible with fluctuating classical light intensity.[ref]
One Hundred Years of Light Quanta by Roy Jay Glauber. 2005 individual Nobel lecture, pp. 86–88, figures 3–4
Institutional report on the Michelson interferometer, interferograms, Fourier transform spectroscopy, interferogram apodization, resolution and sampling. Chapters 13–16 derive the reconstruction and discuss finite-window and sampling limitations.
LIGO differential strain measurement 2026-10-18
Each LIGO instrument is a Michelson interferometer with approximately arms containing Fabry–Pérot interferometers. A stabilized laser illuminates suspended fused-silica mirrors in vacuum. Four-stage suspensions and active isolation suppress ground motion; low-loss materials reduce thermal noise. Power recycling increases circulating power; signal recycling shapes the response to the gravitational wave.[ref]
Why measure two perpendicular arms? In the long-wavelength limit, take a gravitational wave with plus polarization normally incident on ideal perpendicular arms. Its transverse-traceless tensor has and . Expanding each proper length to first order givesHere is dimensionless, whereas is a length. A stipulated and imply , with individual arm changes of opposite sign and magnitude . These are equivalent differential arm-length changes, not a photograph of mirrors moving against a rigid external ruler. The observable compares returning light phases; coordinate systems can distribute the description between mirror coordinates and light propagation.
For unit arm directions , define the detector tensor . If are the transverse polarization tensors, thenThe dimensionless factors encode sky direction and the polarization basis. Thus even identical sources can have different observed amplitudes and wave phases. Motion changing both arms equally cancels in this ideal differential observable, although real asymmetries can couple common disturbances into it.
Suspension supplies an inertial reference above its resonances. For example, a single ideal harmonic oscillator with support motion obeys . Its response at angular frequency is , which decreases in magnitude as well above resonance. The mirror follows slow support drift but approximately free motion in the high-frequency limit. Real multistage suspensions also require damping and alignment control; resonant frequencies are not regions of good isolation.
Rainer Weiss's 1972 report proposed suspended masses, multiple-pass optical delay lines, and a servo holding an interference fringe. Its noise analysis separately treats photon-counting fluctuations, laser frequency instability, mechanical thermal noise, radiation pressure and ground motion. Those delay lines should be distinguished from the resonant arm cavities of Advanced LIGO.[ref]
Electromagnetically coupled broadband gravitational antenna by Rainer Weiss. Typeset transcription of 1972 report, sections 4–5.5, Fig. 1; original scan is linked from DCC record P720002
LIGO displacement readout and control 2026-10-18
An ideal single-round-trip Michelson interferometer converts differential length into phase difference . If its dark-port power scale is and its static phase offset is , thenExactly at a dark fringe, , power is quadratic in small displacement and loses its sign. A deliberate offset supplies an optical reference field: interference with the small signal field produces a linear term. Equivalently, contains . The photodetector measures power, not a signed displacement directly.
Advanced LIGO uses this DC homodyne principle with a small differential arm offset and an output mode cleaner. Its feedback control maintains optical resonance and alignment, using actuation distributed over the suspension stages.[ref]
Advanced LIGO by J. Aasi and others. 2.3 Gravitational wave readout; 4.4.2 Quadruple pendulum design; 4.8 Interferometer sensing and control
The simple formula above omits resonant storage: arm and recycling cavities give a frequency-dependent optical gain and delay, so no constant pass-count multiplier describes the entire observing band.To see why a locked detector can still measure a disturbance, use a linear feedback control model. Let be the external differential displacement, the residual readout, the recorded control command, the sensing response and the actuation response. With the convention , reconstruction givesHere tildes denote Fourier transforms; has readout units per metre and metres per command unit. Feedback suppresses residual motion but records the compensating command. Omitting that command would suppress the reconstructed low-frequency signal too. In the actual GW150914 experiment, a modulated auxiliary laser exerted calibrated radiation pressure on a mirror to measure the response; periodic excitations monitored calibration.[ref]
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914 by B. P. Abbott and others. II Control loop, equations (1)–(4); IV Photon calibrator; VII Time-dependent systematic errors
Michelson interferometer 2026-10-14
A Michelson interferometer divides light at a beam splitter, reflects the two arms at mirrors and recombines the returning fields. For vacuum arm lengths , the delay magnitude is . At each coarse delay, a small mirror scan produces maxima and minima of the detected light intensity. A photodiode and its electrical readout resolve these changes; the scan should cover several carrier cycles while changing negligibly. MIT's laboratory guide uses a mirror actuator, photodiode and electrical drive to scan interference fringes and extract interferometric visibility.[ref]
Optical Interferometry. §§II–IV: apparatus and visibility measurement
A verified motivating experiment is Shaoul Ezekiel's MIT demonstration of source-spectrum control. A polarizer selects one or several lines from a laser whose adjacent lines have orthogonal linear polarizations. A sampled beam goes to a scanning Fabry–Pérot interferometer to check the optical spectrum; the main beam enters a Michelson interferometer, and a lens projects its interference fringes onto a screen. With one selected line the fringes retain good contrast through the demonstrated delay range. With several lines their contrast falls and returns as the arm length changes. At a fixed delay with poor contrast, selecting one line restores it; at matched arms both selections give good contrast. This control isolates the role of spectral composition rather than simply the arm position. The presentation is a qualitative demonstration, not a calibrated linewidth measurement. [ref]
https://ocw.mit.edu/courses/res-6-006-video-demonstrations-in-lasers-and-optics-spring-2008/203f69980203861f374be32d61f9940e_LixwAXsN8vg.pdf. Shaoul Ezekiel, MIT, Coherence length and source spectrum, demonstration transcript
.A deliberately simpler two-line model explains the return of contrast. Take two stationary, mutually uncorrelated monochromatic contributions of equal power at . Their normalized wave-field correlation isfor equal detected single-arm light intensities. At the two contributions' interference fringes cancel on averaging; at they agree again. This is a deduction from the stipulated spectrum, not a fit to Ezekiel's two- or three-line source. Finite individual linewidths eventually damp these revivals.
For a quantitative version of the experiment, the visibility law suggests explicit controls. Measure each arm separately at every coarse delay, subtract the detector's dark signal and any measured background, then normalize by . Keep the returning beams aligned on the same detector region with parallel linear polarizations; keep detector gain fixed and avoid saturation. Resolve the small mirror scan electrically, rather than averaging over its moving interference fringes. Repeat scans to identify vibration or drift. These controls follow from the averaging and mode-matching assumptions in first-order optical coherence; loss of contrast alone cannot distinguish source decorrelation from apparatus motion, misalignment or insufficient spatial resolution. The finite travel range gives access only to a finite range of delays.
The practical gain is that wave interference measures field correlations even when the detector cannot follow the optical oscillation itself. A long optical coherence length allows unequal-arm measurements; a short one localizes high contrast near matched delays. The beautiful feature is that both fading and reappearance of interference fringes are sums of the same rotating complex amplitudes.
Nobel Prize in Physics in 1907 2026-10-18
Albert Abraham Michelson received the award for precise optical instruments and their use in spectroscopy and metrology.[ref]
The Nobel Prize in Physics 1907 by Nobel Prize Outreach. Official summary: laureates, prize shares and motivation
The Michelson interferometer converts relative wave phase into a readout for precise length measurements. Optical coherence 2026-10-14
Optical coherence describes correlations between the wave amplitudes and wave phases of light sampled at different places or times. Its most direct classical test is wave interference: combine two samples of a field and see how much the detected light intensity changes when their relative wave phase is scanned. First-order optical coherence makes this statement quantitative; temporal optical coherence compares delayed samples, while spatial optical coherence compares different positions. These properties are relative to the samples and averaging procedure, rather than a single yes-or-no label for a source. [ref]
https://www.rp-photonics.com/coherence.html. Rüdiger Paschotta, RP Photonics Encyclopedia, Coherence: field correlations and the two kinds of coherence
.A useful surprise is that two copies of a fluctuating source can interfere strongly when they have matched delays: the copies share the fluctuations. Conversely, two individually steady-looking beams need not have correlated wave phases. The ideal diffraction grating calculation requires spatial optical coherence across its illuminated elements; unequal-arm measurements with a Michelson interferometer test temporal optical coherence.
Optical coherence length 2026-10-14
In this temporal sense, the optical coherence length is , where is the vacuum speed of light and is an explicitly chosen optical coherence time. It measures a delay as a vacuum-equivalent path difference; it does not measure transverse spatial optical coherence. [ref].
For the stipulated profiles, the convention gives for the Lorentzian and for the Gaussian. In a vacuum Michelson interferometer, changing one mirror position by changes the round-trip delay by , so the mirror travel to either of these delays is . In a medium, convert physical travel using the actual group delay, which can depend on frequency. For a narrow line centered at vacuum wavelength , differentiating gives ; this small-width approximation must use consistently defined spectral widths.
Optical path length Created 2026-10-05 Updated 2026-10-14
An optical path length measures how much propagation wave phase a path accumulates, expressed as the distance that would accumulate the same wave phase in vacuum. A centimetre in a uniform medium with refractive index has optical path length , although its geometric length remains . This makes optical path length useful whenever two contributions must arrive with matching wave phases, from an optical lens to a Michelson interferometer. [ref]
For a specified path at fixed angular frequency , the optical path length is the line integralHere is geometric arc length, and is the phase refractive index, evaluated at the same frequency everywhere. The propagation interpretation assumes a stationary linear medium with isotropy, a real positive scalar refractive index and negligible loss, on a valid geometrical optics branch. The path can curve; at sharp interfaces apply the appropriate matching conditions to each segment. A prescribed curve has a mathematical line integral, but it predicts a propagation wave phase only when it represents the physical branch. [ref] Optical fibers can require a mode wavenumber rather than the bulk refractive index along a guessed light ray. [ref]
Fix the vacuum wavelength , with frequency and vacuum wavenumber . In a locally uniform medium the wavelength is , while the frequency stays unchanged at a stationary interface. With the convention , propagation from a specified starting wave phase contributesThe relative reference includes launch wave phases and any extra wave phase from mirrors, beam splitters or coatings. Thus is a propagation contribution, not an absolute detector wave phase independent of the apparatus. If the reference contributions stay fixed, a change in optical path difference changes the phase difference by . Using the material wavelength again in this formula would count the refractive index twice. [ref]
Optical path difference in a Michelson interferometer: apparatus schematic and a calculated phase difference readout
. Details. A motivating measurement turns invisible optical oscillations into a slowly changing electrical signal. MIT's teaching experiment uses a laser, a beam splitter, two returning mirrors, an amplified photodiode, an oscilloscope and a calibrated mirror actuator driven by a function generator. The returning beams overlap on the photodiode; one channel records detector voltage and another the actuator drive. The measured observable is the changing light intensity, including its maxima and minima, rather than direct timing of an optical cycle. A calibrated displacement per drive voltage and the spacing of the extrema relate geometric motion to the phase difference. The guide infers the laser wavelength from known actuator calibration; conversely, with independently known vacuum wavelength and ambient refractive index, the same relation calibrates mirror motion. These two unknowns cannot both be inferred from fringe spacing alone. [ref]
For a proposed change-of-medium measurement, keep the mirrors fixed and put a transparent cell of internal length in one arm. Compare its contents at refractive indices and , leaving its windows in place. At normal incidence the two traversals giveHere is the signed number of whole interference fringe cycles plus any resolved fractional cycle, counted continuously. A mirror displacement instead gives ; distinguish this double-pass factor from a single pass in a Mach-Zehnder interferometer. OpenStax's gas-cell worked example provides the same double-pass reasoning; it is a teaching calculation rather than a published measurement dataset.[ref]
An exact toy calculation makes the sensitivity visible. Stipulate , and . Then and : a full interference fringe cycle, despite unchanged geometric lengths. For a continuous change , let and choose the initial detector phase difference to be zero. Equal coherent detected arm contributions of light intensity predictThe plot is this stipulated model: gives a minimum, restores a maximum, and the reference level is chosen by adjustment of the apparatus. It contains no measured values or assigned properties of a real gas. The equivalent mirror travel in vacuum is per cycle. A single endpoint light intensity cannot distinguish from ; the continuous fringe count carries the missing information.
For an interpretable cell measurement, establish the initial phase difference with a small calibrated mirror scan, then track slow changes through successive interference fringes. Measure the dark signal and each arm separately, keep photodiode gain within its linear range, align both beams on the same region and match their linear polarizations. Monitor interferometric visibility and keep arm delays within the useful optical coherence time. Record cell length, contents, pressure and temperature; return to the starting condition to check drift. Changes in window deformation, cell length, external air or mirror position also change optical path length, so a reference cell or an independently monitored mechanical path is needed to isolate the contents' refractive index. These controls are deductions from the model, not a claim that the illustrated apparatus was operated. Loss of fringe count leaves a whole-cycle ambiguity; at an intensity extremum the first derivative with respect to phase difference vanishes, so a scan around phase quadrature is more sensitive to small changes. Broadband illumination, unstable optical coherence, vibration and strong loss can invalidate a simple one-frequency inference.
Let . At the port that is bright for zero delay, the ideal 50:50 Michelson interferometer givesEach arm has field amplitude one half after two beam-splitter interactions. For , approximate both real Gaussian envelopes by while retaining their rapidly varying phases. Put and . The identity giveswhereA delay-dependent constant overall phase can be shifted by a port convention, but the expression above follows directly from the specified bright-port sum.
The output intensity is a Gaussian envelope modulated by a squared cosine:The modulation maxima are separated byThis is the spacing of resolved adjacent pulse peaks when the envelope changes little over a modulation period, requiring . The source's assumption alone does not ensure several visible peaks: a weakly chirped pulse may show only one broad maximum. At the output is the original pulse and the modulation-spacing formula has no finite-peak interpretation. The figure compares the exact bright-port field sum with the small-delay approximation.
Temporal interference of chirped pulses at small and large Michelson delays
. Details. Temporal coherence measures correlation between an optical field and a delayed copy. For a stationary scalar complex field with carrier convention ,The power spectrum and the field autocorrelation form a Fourier transform pair, the Wiener-Khinchin theorem:A Michelson interferometer supplies delay . With equal arm intensities and matched polarization, its interferometric visibility is ; unequal intensities or mode mismatch lower visibility independently of temporal coherence. The relevant spectrum is the optical field spectrum, not the low-frequency spectrum of detector intensity fluctuations.
For a single Lorentzian optical line of angular-frequency full width at half maximum , use the narrow-line detuning modelSuch a model describes a phase-diffusing monochromatic source. An correlation time is , and its coherence length is . The Lorentzian extension over all detunings approximates a narrow optical line with .
For two equal, mutually incoherent ideal monochromatic spectral lines,Here and . Visibility has zeros and revivals, so the overall spectral span alone does not determine a unique decay time. Giving each line a common finite Lorentzian linewidth multiplies this beating correlation by the corresponding exponential envelope.
These two examples distinguish irreversible envelope decay from cancellation and revival of discrete spectral components. The line profiles are explicit models, not claimed measurements of a particular source.
The five tasks below concern a scanned Michelson interferometer. The original dashed curves are labelled visibility in arbitrary units; divide them by their maximum to obtain normalized interferometric visibility, which lies between zero and one.
A gravitational wave produces a time-dependent tidal distortion. For a normally incident plus-polarized wave in the long-wavelength limit, two perpendicular freely suspended arms change by and . Their differential length is thereforefor a simple round-trip Michelson interferometer. LIGO uses kilometre-scale orthogonal arms with optical cavities that enhance the phase response, a stabilized laser and suspended mirrors in vacuum. As an illustrative scale, across a 4 km arm corresponds to differential length . The measured quantity is returning light phase, not mirror displacement against a rigid external ruler. Optical storage and control loops give a frequency-dependent calibrated response.
Seismic and terrestrial disturbances dominate low frequencies, thermal motion of suspensions and mirror coatings contributes at intermediate frequencies, and photon shot noise limits high-frequency readout. Isolation and suspension systems reduce ground coupling; low-loss materials reduce thermal noise; vacuum suppresses gas scattering and forces. Greater optical power reduces shot noise but increases radiation-pressure fluctuations and thermal demands. Stable optical alignment and feedback are essential, yet their own sensor and actuator noise must be controlled. These are engineering requirements because the desired strain is extraordinarily small.[ref]
LIGO: The Laser Interferometer Gravitational-Wave Observatory by B. P. Abbott and others. Instrument configuration and detector-noise discussion; primary initial-LIGO account
A candidate should appear coherently at separated observatories with consistent propagation delay and antenna response. Auxiliary environmental monitors, calibration injections and time-shifted coincidence backgrounds test instrumental explanations. Matched filtering is powerful for modelled compact-binary chirps; coherent burst searches allow less predictable signals. Binary-pulsar orbital energy loss already provided indirect evidence for gravitational radiation before 2013, but it is distinct from directly measuring passing waves.[ref]
Binary Pulsars and Relativistic Gravity by Joseph Hooton Taylor Jr.. Binary-pulsar orbital-decay test of relativistic gravity
At the examination date, direct detection remained a search objective. Reliable detection requires both sufficient strain sensitivity and a demonstrated astrophysical signal rather than correlated or accidental noise.In Fourier transform spectroscopy, a scanning Michelson interferometer measures intensity against optical path difference rather than selecting one narrow wavelength at a time. After subtraction of the constant background, an ideal stationary source gives an interferogramA cosine Fourier transform recovers the spectral power density after instrumental calibration. A mirror displacement changes the round-trip path by ; the zero-path-difference burst aligns the scan, and a reference laser can calibrate the displacement.
Finite maximum path difference multiplies the interferogram by a window and convolves the recovered radiation spectrum with that window's Fourier transform. Thus is of order ; precise factors depend on scan range and resolution convention. Uniform path samples of separation need to avoid aliasing without bandpass information. interferogram apodization reduces sidelobes at the price of broader lines. The broad accepted optical throughput can be advantageous; the multiplex signal-to-noise advantage depends on detector noise and is not universal in photon-noise-limited measurements. Source drift during a scan, finite beam divergence, imperfect sampling and wave phase errors require control. The finite-window reasoning is the delay-range resolution in Fourier transform spectroscopy.[ref]
Introduction to Fourier Transform Spectroscopy by Julius Cohen. NBSIR 86-3339, chapters 13–16, printed pp.51–80: basic equation, apodization, resolution and sampling