Radiation pressure is the normal momentum flux transferred by electromagnetic radiation to a surface. A photon travelling in vacuum carries momentum , where is its energy, its frequency, the Planck constant and the speed of light. Photon absorption transfers that momentum; specular reflection reverses its normal component. This lets light exert a force even when almost no energy becomes heat in the receiver.
Two useful formulas describe different preparations. A directed beam normally incident on a stationary perfect absorber gives pressure , and on a stationary perfect mirror gives . Here is light intensity, the incident power per beam cross-sectional area perpendicular to propagation, in . An isotropic photon gas has pressure , where is its radiation internal energy per volume, in . Stored energy density and travelling energy flux must be distinguished: an isotropic field can have zero net energy flux and positive radiation pressure.
The physical appeal is that the same momentum conservation connects a single photon collision, a mirror's measurable force, and a radiation-filled cavity's equation of state. The directional calculation below complements radiation pressure on a perfectly absorbing surface; the equilibrium spectrum and its temperature dependence belong to blackbody radiation and the photon gas.
For normal incidence in vacuum, a uniform beam delivers energy to an illuminated surface area during time . A perfect absorber receives momentum , so force divided by surface area gives . A perfect stationary mirror sends the photons back with reversed momentum, so momentum conservation gives twice the normal transfer, . These are time-averaged pressures; the microscopic arrivals need not be uniform.
Figure 1.
Photon momentum transfer to an absorber and a mirror
. Original idealized normal-incidence diagram. Blue arrows show the incoming photon momentum; orange shows the reflected photon momentum. The green arrow is the momentum delivered to the receiver, not another outgoing photon. The mirror reverses the incoming momentum and therefore receives twice as much. Details.
For a stipulated model light intensity and the exact SI speed of light ,
These are computed predictions, not measured data or a universal sunlight value. If the beam fully covers a normally oriented surface area , the intercepted radiant flux is and the absorber's force is . Using the total source power would be wrong if only part of its beam reaches the receiver. The absorption prediction assumes complete photon absorption, while the reflection prediction assumes complete specular reflection; transmission, scattering of light and directed thermal photon emission require their own outgoing momentum accounting.
Measure the angle of incidence between the incoming path and the surface's normal line, with . There are two separate cosine factors. A fixed actual surface area intercepts only its projected area , so . Each incoming photon supplies normal momentum on absorption, or twice that on specular reflection. Thus, for radiometric absorptance and reflected power fraction ,
This model assumes transmitted light continues straight in the same medium and carries away its original momentum. It omits thermal recoil and assumes a stationary receiver. At , fixed beam light intensity therefore gives one quarter of the normal-incidence pressure. For fixed intercepted radiant flux , however, the normal force has only one cosine factor. Equivalently, if the given quantity is receiving-surface irradiance , then . The distinction matters when interpreting an experiment's angle scan. [ref]
Absorption also transfers a tangential momentum component at oblique incidence. It contributes a tangential force, rather than normal pressure. Ideal specular reflection preserves the tangential momentum component, so it transfers only normal momentum.
For radiation in vacuum with isotropy, energy is distributed equally per solid angle: write for energy density per unit solid angle. Let be the angle between a ray's path and the wall normal. Its normal velocity determines the arrival rate, while normal momentum per energy is . Their product is . For a perfectly reflecting cavity wall,
The leading two is the normal momentum reversal; the incoming hemisphere contains half of the field's directional energy density. This is also the normal component of the bulk pressure tensor, . Isotropy makes all three diagonal components equal, while their sum is because the squared direction components sum to one. The factor one third therefore depends on three-dimensional angular geometry, not on the shape of the blackbody radiation spectrum.
Figure 1. . Original angular model of a reflecting cavity wall. The left panel shows representative incoming paths, not a literal two-dimensional photon gas. The right panel uses the correct three-dimensional solid angle weight, normalized on an incoming hemisphere: . The normal pressure contribution adds , giving total weight . Details.
A perfectly absorbing wall exposed to this incoming hemisphere receives only from absorption. If it is in thermal equilibrium with the isotropic radiation, its outgoing emission supplies another of recoil, recovering . A cold absorber before equilibrium is a different boundary condition. Similarly, the one-way incident energy flux is , whereas the net energy flux across a plane in the undisturbed isotropic field is zero. Dividing by misses the extra normal-momentum projection and does not give the cavity pressure.
For a stipulated isotropic radiation energy density , the bulk pressure is regardless of its spectral shape. In thermal equilibrium, blackbody radiation supplies with radiation constant , so ; Stefan–Boltzmann law defines . The equilibrium photon gas derives this same equation of state from its free energy.[ref]
A 2013 experiment by Paul A. Williams and collaborators mounted a 25-mm dielectric mirror on a commercial force-restoration balance. Removing its pan-weight compensation spring allowed horizontal force sensing with a horizontal laser path. They measured mirror optical reflectance and varied incidence from about to . A 1071-nm laser, capable of 530 W, was switched at 0.1 Hz. Digitized mass-equivalent readings were converted to force using ; quadrature demodulation isolated the switched signal from drift. [ref]
Measurement calibration used a 20-g mass, with checks down to 1 mg. The optical forces lay below that checked range, limiting the accuracy claim. An angle scan tested the predicted cosine dependence at fixed intercepted power. Replacing the mirror with a carbon nanotube coated absorber increased absorbed power while reducing the predicted optical force; no modulation peak was detected. This bounded gas-heating artifacts under those conditions, rather than proving their universal absence. The fitted slope was about 7% below . Inferring laser power requires calibrated force, optical reflectance, radiometric absorptance and angle of incidence, with measurement uncertainty for each. [ref]

Ancestors (6)