Thermal conduction Created 2026-09-24 Updated 2026-10-14
Thermal conduction transfers heat through microscopic interactions without bulk transport of matter. To predict the heating load through a bar, combine Fourier's law with conservation of energy and the imposed end temperatures. In the isotropic model with positive thermal conductivity , the conductive heat flux points from high to low temperature, opposite to the temperature gradient. A spoon warming along its handle and heat escaping through a wall are familiar examples.
Consider a bar of length , constant cross-sectional area and constant thermal conductivity . Maintain its ends at and , with increasing toward the colder end. Assume a steady state, one-dimensional thermal conduction, no internal sources and no heat transfer through the sides. The temperature falls by over , giving
The difference between the two readings in degree Celsius units is the same -kelvin difference. The positive heat flux carries heat toward increasing .
Figure 1.
Steady thermal conduction through a bar: declining temperature, constant heat flux
. An isotropic bar with stipulated constant thermal conductivity , length and cross-sectional area . Its ends remain at and , and its sides exchange no heat. The lower panel distinguishes from . Details.
The general solution under these assumptions is
A proof outline is enough to explain the straight line: conservation of energy in any small slice, with no accumulation, sources or side losses, gives . Constant cross-sectional area gives ; constant thermal conductivity and Fourier's law then give . Two integrations and the end boundary conditions determine the displayed affine function. This is why a visually simple temperature profile can encode a continuous flow of energy. [ref]
Doubling the length halves the rate, while doubling the cross-sectional area doubles it, at fixed end temperatures and thermal conductivity. This explains why a long narrow support can limit unwanted heat transfer, while a short broad path can help remove heat. Joining materials leads to thermal resistance in series. During initial warming, internal energy can accumulate and the temperature profile need not be a straight line; the time dependence is described by the heat equation and thermal diffusivity.
Now join two layers, each of length , with constant cross-sectional area and stipulated constant thermal conductivities and . Keep the outer ends at and . Assume a steady state, one-dimensional thermal conduction, no internal sources or side losses, and perfect contact: the temperature is continuous at the interface, with no extra contact drop. For each layer, use the area-specific thermal resistance and . The series calculation gives
Figure 2.
Two layers in series: continuous heat flux, different temperature gradients
. Each layer is long with the same cross-sectional area and perfect contact. Stipulated constant thermal conductivities are and . The temperature drops by and , reaching at the interface, while and throughout. Details.
The heat flux is continuous: otherwise energy would accumulate at the interface. Yet Fourier's law gives different temperature gradients, and . Lower thermal conductivity requires a steeper temperature gradient to carry the same heat flux; equal lengths therefore give drops in the ratio . A kink in the temperature profile records the change of material while perfect contact keeps the temperature itself continuous.
Thermal convection Created 2026-09-28 Updated 2026-10-06
Thermal diffusion 2026-11-05
Here thermal diffusion means the spreading of temperature by thermal conduction. In a stationary homogeneous material with constant thermal conductivity , mass density and specific heat capacity , energy balance and Fourier's law give the heat equation , where is the thermal diffusivity.
A disturbance spreads over a length of order , so equilibration across thickness takes a time of order . This is the heat-transport sense of the term; temperature-gradient-driven separation of components in a mixture is a distinct transport effect.
Thermal diffusion length 2026-10-14
The thermal diffusion length is the characteristic length over which thermal conduction changes a temperature distribution during time in the constant-thermal diffusivity model. It is a scale, not a sharp front or distance travelled at a constant speed: the heat equation has infinite propagation speed mathematically. Different definitions of penetration depth introduce numerical factors. In particular, the normalized one-dimensional heat kernel has spatial variance , so its root-mean-square width is .
Figure 1. . Original predictions for the two stipulated materials in thermal diffusivity. Left: , with four times the time needed to double length. Right: on logarithmic axes. Equal thermal conductivity with four times the volumetric heat capacity halves the reached length at a given time and quadruples the time at a given length. The scale differs from the insulated-bar decay time by the factor . Details.
At , the model materials have thermal diffusion lengths and . For their thermal diffusion times are and . These values describe the same heat equation as the thermal diffusion rate of a Fourier mode; the different numerical factors come from the definition of the scale.
Thermal diffusivity Created 2026-09-24 Updated 2026-10-14
Thermal diffusivity measures how rapidly thermal conduction smooths a temperature difference inside a material. Thermal conductivity measures the heat flux driven by a specified temperature gradient; thermal diffusivity also accounts for the heat capacity that must be warmed. A material can carry substantial heat yet change temperature slowly because it stores substantial internal energy per kelvin.
Write for thermal diffusivity, reserving for thermal conductivity. In a homogeneous isotropic material,
Here is mass density, is specific heat capacity for the relevant mechanical constraint, and is volumetric heat capacity. The familiar uses specific heat capacity at constant pressure. For ordinary solids with negligible thermal expansion, the difference between the two constrained specific heat capacities is often neglected. A rigid fixed-volume model instead uses specific heat capacity at constant volume; a compressible moving fluid requires the accompanying work and transport terms. Thus the constraint is part of the approximation, not a choice made solely from the units. [ref]
Assume a stationary material in the continuum approximation, local thermal equilibration on times shorter than those resolved, no internal heating, no phase transition, and negligible convection and mechanical work. Combining conservation of energy with Fourier's law gives the one-dimensional balance
If are constant over the region and temperature excursion, this becomes the heat equation . If varies, retain the differentiated product; replacing it with loses a term. Anisotropic materials need a thermal conductivity tensor. The scalar constant- examples below deliberately exclude these complications. [ref]
For an original comparison, stipulate two model materials with equal thermal conductivity and equal mass density , but specific heat capacities and . Then
At the same temperature gradient, both have the same instantaneous heat flux by Fourier's law. At the same initial temperature profile and boundary conditions, material B takes four times as long to smooth a given spatial pattern. With fixed end temperatures, identical geometry and no sources, both eventually have the same steady profile and heat flux. The larger heat capacity changes the transient, not this steady state. These are stipulated parameters, not measurements of named substances.
For a sharp thermal front moving at fraction of the Darcy velocity , a cold fluid of viscosity displacing its hot counterpart of viscosity has the displayed growth rate in the local, unbounded planar approximation without thermal conduction. The harmonic pressure perturbations decay on either side. Pressure continuity and continuity of perturbed Darcy flux give the velocity response ; the thermal front's kinematic law is . The prefactor is the thermal-front speed, not the material pore velocity. Increasing viscosity with heating therefore makes the trailing thermal interface unstable even when the leading displacement of the original fluid is stable.
Thermal resistance Created 2026-10-14 Updated 2026-10-18
Thermal resistance measures the temperature drop required to drive a given rate of heat transfer. For the steady one-dimensional bar model in thermal conduction,
Here relates the temperature drop to heat flux, while relates it to the rate of heat transfer. The single bar above has and , so its drop drives .
To see why series thermal resistances add, apply Fourier's law in each layer to obtain . With no accumulation or side losses the rate of heat transfer is the same through both, so adding the drops gives . This lets us size layered walls without solving a new differential equation for every layer. The structure matches Ohm's law: temperature difference plays the role of electric potential difference, the rate of heat transfer plays the role of electric current, and thermal resistance plays the role of electrical resistance. [ref]
Thermistor 2026-10-18
A thermistor is a temperature-sensitive resistor used as a resistance thermometer. Its calibrated electrical resistance supplies a temperature indication; probe heat capacity and unwanted thermal conduction can affect its response and immersion error.
Thermodynamic equilibrium 2026-10-14
A thermodynamic system is in thermodynamic equilibrium when its macroscopic state has no spontaneous tendency to change through any exchange allowed by its constraints. For an isolated system, stable thermodynamic equilibrium maximizes entropy over the accessible states at fixed total energy and conserved material inventories. A wall can forbid an exchange, so always specify what can cross or move. Thermal, mechanical and chemical conditions answer different questions about that same constrained state. [ref]
For example, two compartments separated by a rigid, impermeable wall that transmits heat can reach thermal equilibrium while retaining different pressures and compositions. Allowing an unloaded piston to move adds a mechanical equilibrium condition. Allowing one chemical species to cross adds chemical potential equality for particle exchange; allowing a chemical reaction adds its chemical equilibrium condition. A fixed barrier can therefore support a constrained thermodynamic equilibrium that ceases to be an equilibrium when the barrier is removed.
Uniformity is not the definition of thermodynamic equilibrium. An isothermal atmosphere in hydrostatic equilibrium can have a common temperature while its pressure and mass density vary with height: the pressure gradient balances gravity. In an external field, the exchange condition must include the relevant potential energy; for charged matter this leads to the electrochemical potential. Relativistic gravitational corrections to thermal equilibrium are described separately by the Tolman temperature law.
A steady state only says that the macroscopic description is constant in time. A bar maintained between hot and cold thermal reservoirs has steady heat flux and produces entropy, so it is not in thermodynamic equilibrium. Even matching temperatures at one perfect-contact interface can coexist with heat transfer through the surrounding material; matching those two local values does not establish equilibrium of the whole apparatus. See thermal conduction for that spatial transport problem.
The useful simplification is that equilibrium conditions predict an endpoint without computing every collision or flow during relaxation. The first law of thermodynamics supplies the conserved quantities, and the Second law of thermodynamics supplies the direction of change. For a system held at fixed temperature and volume, the corresponding criterion is minimization of Helmholtz free energy; at fixed temperature and pressure, it is minimization of Gibbs free energy, with the material and exchange constraints still imposed.
Water calorimetry 2026-11-05
Water calorimetry measures an energy transfer using the thermal response of water. In radiation metrology, it determines absorbed dose to water from a small measured temperature rise. The ideal conversion follows from and :
where is water's specific heat capacity. The sample mass cancels because dose is energy per unit mass.[ref]
For an original scale estimate, take as an illustrative near-room-temperature value. An absorbed dose of would then give only , about . Detecting such a small change requires careful thermometry and separation from background thermal drift.
The physical conversion also has chemical assumptions. Heat defect describes the fraction of absorbed energy that does not appear as heat because of radiation-induced chemical change. Thermal conduction, convection and sensor effects are additional measurement questions, rather than alternate names for that chemical correction. This makes water calorimetry an example of an apparently direct energy measurement whose interpretation still needs a well-defined model.