Topics (384k) Articles (398k) Users (410) Discussions (242) Comments (383) Files (13k) New article
An airfoil mean camber line is the reference curve midway between the upper and lower surfaces of an airfoil, using a specified surface-pairing convention. It separates the bending of the profile from its thickness. In a symmetric airfoil, the mean line lies on the airfoil chord.[ref]
For the normal-offset construction used in a NACA four-digit airfoil, let the mean-line point be , let be its unit normal vector, and let be the local half-thickness. The paired surface points satisfyAdding and subtracting gives and . The pair shares a construction parameter, not necessarily the same physical chordwise coordinate.[ref]
For an original local example, take paired coordinates and . Their midpoint is , and the half-thickness is . The separation direction is proportional to , so the corresponding tangent direction is proportional to . It would be incorrect to call either endpoint's horizontal coordinate the common construction station.
For surface data tabulated as two graphs at the same , the vertical midpoint defines a useful alternative convention. It need not exactly invert a normal-offset construction with a sloping mean line. Extracting a mean line from measured coordinates must therefore identify the pairing and interpolation rule. Airfoil camber summarizes its departure from the chord; directional measurement of trailing-edge thickness shows the related directional ambiguity at the rear endpoint.
Direct calorimetry measures a process's thermal output or absorption through the response of a calorimeter. The observations can be a receiver's temperature change or a measured heat transfer rate across a controlled boundary. Converting those observations into energy or power requires a calibrated thermal response and an accounting of storage and losses.
A flow calorimeter provides a concrete physical arrangement. A heated component transfers energy to a coolant stream; inlet and outlet thermometers measure its temperature rise, while a flow measurement supplies the mass flow rate. With negligible changes in bulk kinetic energy and height, the stream's enthalpy gain isHere is specific heat capacity at the relevant pressure and temperature. Manufacturer documentation for a water calorimeter likewise describes monitoring water flow and temperature to determine absorbed incident power.[ref]
Water calorimeter power detectors by Gentec-EO. Publisher description, water-flow and temperature monitoring for calorimetric power measurement
For an illustrative water flow of , a rise and approximately ,Over 60 seconds at those conditions, the stream carries away about . These assumed values describe a calculation, not a product specification.
A broader energy balance can readIf the vessel is still warming, some input is stored rather than carried away. Heat leakage can also leave the chosen boundary through another path. Electrical calorimetry can check the response by supplying a measured heater input and comparing it with the readout. Establishing a steady state, matched thermometer calibration and a clear thermodynamic system boundary makes the inferred source power credible.
Indirect calorimetry estimates an energy-release rate from measured chemical exchanges and a model relating those exchanges to chemical energy. Gas-analysis implementations measure oxygen disappearance and often carbon dioxide production; stoichiometry and energy equivalents then supply the inference. The physical measurement chain therefore contains both observations and assumptions, rather than a direct measurement of the entire heat transfer.
A controlled combustion system makes this logic concrete. A gas stream passes through a reaction region, exhaust flow and composition are measured, and the difference between incoming and outgoing oxygen amounts gives an uptake rate. In oxygen consumption calorimetry, that rate is combined with an appropriate energy-per-oxygen factor to estimate heat release rate. A falling oxygen fraction alone is insufficient: dilution and changes of total gas flow must also be accounted for.[ref]
National Fire Research Laboratory by NIST. Facility description, exhaust system and oxygen-consumption measurement of fire heat release rate
For a deliberately stipulated model with and measured oxygen uptake ,This factor is an assumption for the calculation, not a universal physical constant. Different reaction mixtures, incomplete oxidation or changing product composition can require a different model. Gas volumes must likewise be tied to stated temperature and pressure before they become comparable amounts.
An independent reference tests the chain. NIST describes natural-gas reference burners whose fuel-consumption-based heat input cross-checks its oxygen-consumption calorimetry system. The agreement then tests gas sampling, flow measurement and the adopted energy accounting together, rather than merely checking one sensor.[ref]
Natural Gas Confirmation Burner by NIST. Research Overview, reference burners and mutual confirmation of fuel- and oxygen-consumption calorimetry
Water calorimetry measures an energy transfer using the thermal response of water. In radiation metrology, it determines absorbed dose to water from a small measured temperature rise. The ideal conversion follows from and :where is water's specific heat capacity. The sample mass cancels because dose is energy per unit mass.[ref]
An Absorbed Dose Water Calorimeter: Theory, Design, and Performance by Steve R. Domen. Abstract and opening description: calibrated thermistors and temperature-rise dose measurement.
For an original scale estimate, take as an illustrative near-room-temperature value. An absorbed dose of would then give only , about . Detecting such a small change requires careful thermometry and separation from background thermal drift.
The physical conversion also has chemical assumptions. Heat defect describes the fraction of absorbed energy that does not appear as heat because of radiation-induced chemical change. Thermal conduction, convection and sensor effects are additional measurement questions, rather than alternate names for that chemical correction. This makes water calorimetry an example of an apparently direct energy measurement whose interpretation still needs a well-defined model.
A fractional derivative extends differentiation to noninteger orders, but a choice of definition and endpoint data is part of the operator. For , the left Riemann-Liouville version iswhen the integral and derivative exist. Here is the gamma function. The value depends on a whole interval of earlier values rather than only on values arbitrarily near , making such operators useful in models with memory.[ref]
NIST Digital Library of Mathematical Functions. Sections 1.15(vi)–(vii), fractional integrals and derivatives
For and , direct use of the beta function gives , with the usual reciprocal-gamma interpretation at poles. In particular, . The alternative Caputo definition integrates instead and sends a constant to zero. These are different operators, even though both recover familiar derivatives in appropriate integer-order limits.
Graft patency is the openness of a graft’s lumen to blood flow. For a bypass graft, an open route is a necessary anatomical observation, but it does not by itself establish adequate tissue perfusion or a favorable overall clinical outcome. A conduit can remain open while narrowing progressively.
Reporting must also specify the history of that openness. In the 1997 vascular reporting standard, primary graft patency describes uninterrupted patency without a qualifying intervention on the graft or its anastomosis. Assisted primary graft patency allows intervention before an occlusion; secondary graft patency allows restoration after occlusion under the stated reconstruction rules. Procedures confined to disease beyond the graft and its anastomoses have specific exceptions. The exact endpoint definition must accompany the result.[ref]
Recommended standards for reports dealing with lower extremity ischemia: Revised version by Robert B. Rutherford and others. Printed pp. 524–525, Patency status: primary vs secondary patency
An original complete-follow-up example shows why one percentage is insufficient. Ten grafts are followed for the same interval: six need no procedure, two remain open after preventive graft interventions, one occludes and is successfully reopened, and one remains occluded. The corresponding endpoint proportions are primary, assisted primary and secondary patency. They describe the same cohort, not three competing estimates of one quantity. The last figure includes grafts that never required rescue.
With unequal observation times, the percentage of grafts open at their last visit is not a fixed-time patency estimate. Survival analysis, including the Kaplan–Meier estimator, tracks time to the chosen endpoint and handles right censoring under stated assumptions. Loss to follow-up and death need explicit treatment; simply deleting them can bias a comparison.
Observation is also method-dependent. Ultrasound follow-up can document graft status and detect developing abnormalities. Measurements of narrowing or flow velocity, the occurrence of occlusion and the need for intervention are related but different records. Specifying which was measured makes graft patency useful for comparing graft materials, surveillance strategies and vascular surgery outcomes.[ref]
Surgical Bypass by the Society for Vascular Surgery. Follow-up ultrasound discussion
A Bourdon tube pressure gauge combines a pressure-sensitive Bourdon tube with a motion-transmission mechanism, pointer and calibrated scale. Pressure-driven elastic deformation moves the free end of the tube; a linkage and geared movement convert that motion into an indication on the dial. WIKA's technical diagram identifies the tube, end piece, link, movement, pointer and pressure connection as distinct parts.[ref]
Elastic element pressure gauges by WIKA. IN00.01,09/2010, p1, labelled Bourdon-gauge mechanism
The complete gauge is a measuring system. Its measurement indication depends on the sensing tube and the motion transmission, including possible backlash and hysteresis. For a vented case, the tube responds to pressure relative to the surrounding atmosphere, so the intended quantity is gauge pressure. The dial alone does not define an absolute pressure reference.
For an original instrument calibration comparison, connect the gauge and a suitable pressure reference to a common fluid source. Apply several increasing pressure steps, wait for stable readings, and return through the same pressures. Record each discrepancy and distinguish the two loading directions. This tests the assembled readout rather than only the elastic element.
The locations of the pressure ports can matter as much as their shared supply. If the test gauge's port is below the reference port in a stationary water-filled connection, take and . Hydrostatic pressure givesWithout that correction, a correct lower gauge can appear to overread the upper reference. These are original apparatus values, not manufacturer test data.
Read the error specification for the actual model and size. WIKA's June2025 US sheet, for example, states an accuracy of of span for the specified four- and six-inch versions, while listing a different specification for the smaller version.[ref]
Bourdon Tube Pressure Gauges, Stainless Steel Series by WIKA. 23X.50,06/2025, p1, Accuracy class
A percentage of span is not the same percentage of the instantaneous reading. Retain range, conditions, corrections and measurement uncertainty with the reported result.An input-output gain bounds how large a system's output can be relative to its input, after the input and output measures have been specified. For a zero-initial-state operator and chosen signal norms, its induced signal gain isA finite gain gives . The supremum is over the admissible input class, not merely a collection of trial inputs. Initial-state response must be treated separately.
For an original scalar linear time-invariant system, letUsing the time-domain L-infinity norm, the convolution solution obeysA constant input of suitable sign approaches the limiting ratio , so this bound is sharp. At and , the peak-amplitude gain is1.5: an input bounded by2 gives output bounded by3 from zero initial state, and the constant input approaches that value.
The signal norms change the problem. For the same stable scalar system, the peak frequency response magnitude isIt coincides numerically with the preceding gain in this example. For stable linear systems, this frequency-domain quantity is the energy-signal induced gain associated with the time-domain L2 norm; it should not generally be identified with the peak-amplitude induced gain. MathWorks's linear-model
norm documentation distinguishes this peak frequency-response quantity from its separate impulse-response norm.[ref]The units matter as well: a gain from force input to displacement output has physical units, whereas identical normalized signal units can produce a dimensionless gain. In robust performance, the bound must hold across the allowed control model uncertainty. A nominal gain calculation alone supplies no such universal guarantee.
Pinned article: Introduction to the OurBigBook Project
Welcome to the OurBigBook Project! Our goal is to create the perfect publishing platform for STEM subjects, and get university-level students to write the best free STEM tutorials ever.
Everyone is welcome to create an account and play with the site: ourbigbook.com/go/register. We belive that students themselves can write amazing tutorials, but teachers are welcome too. You can write about anything you want, it doesn't have to be STEM or even educational. Silly test content is very welcome and you won't be penalized in any way. Just keep it legal!
Intro to OurBigBook
. Source. We have two killer features:
- topics: topics group articles by different users with the same title, e.g. here is the topic for the "Fundamental Theorem of Calculus" ourbigbook.com/go/topic/fundamental-theorem-of-calculusArticles of different users are sorted by upvote within each article page. This feature is a bit like:
- a Wikipedia where each user can have their own version of each article
- a Q&A website like Stack Overflow, where multiple people can give their views on a given topic, and the best ones are sorted by upvote. Except you don't need to wait for someone to ask first, and any topic goes, no matter how narrow or broad
This feature makes it possible for readers to find better explanations of any topic created by other writers. And it allows writers to create an explanation in a place that readers might actually find it.Figure 1. Screenshot of the "Derivative" topic page. View it live at: ourbigbook.com/go/topic/derivativeVideo 2. OurBigBook Web topics demo. Source. - local editing: you can store all your personal knowledge base content locally in a plaintext markup format that can be edited locally and published either:This way you can be sure that even if OurBigBook.com were to go down one day (which we have no plans to do as it is quite cheap to host!), your content will still be perfectly readable as a static site.
- to OurBigBook.com to get awesome multi-user features like topics and likes
- as HTML files to a static website, which you can host yourself for free on many external providers like GitHub Pages, and remain in full control
Figure 2. You can publish local OurBigBook lightweight markup files to either OurBigBook.com or as a static website.Figure 3. Visual Studio Code extension installation.Figure 5. . You can also edit articles on the Web editor without installing anything locally. Video 3. Edit locally and publish demo. Source. This shows editing OurBigBook Markup and publishing it using the Visual Studio Code extension. - Infinitely deep tables of contents:
All our software is open source and hosted at: github.com/ourbigbook/ourbigbook
Further documentation can be found at: docs.ourbigbook.com
Feel free to reach our to us for any help or suggestions: docs.ourbigbook.com/#contact





