Direct current 2026-10-14
A direct current is an electric current that flows in one direction; its magnitude may vary with time. A constant or steady electric current additionally has a value independent of time. Thus a direct current need not be constant. The steady direct current model of a voltage divider assumes a constant input electric potential difference and fixed electrical resistances.
Loaded voltage divider 2026-10-14
Connect a passive electrical load of electrical resistance from the junction to the reference. In the steady direct current model, and share the same electric potential difference and are connected in parallel. Their equivalent electrical resistance is
This is the replacement required when a voltmeter is connected across . The inspected teaching guide explicitly models the meter this way.[ref]
The Kirchhoff's current law proof makes the changed assumption visible:
The upper resistor carries the sum of the lower and load electric currents, so the two original resistors no longer have equal electric currents. In the stipulated example, , the upper current is , and each lower branch carries .
For a digital multimeter used as a voltmeter, let its input electrical resistance on the selected voltage range be . With no other load, set ; if an intended load is also present, use in place of . Two instruments connected simultaneously add two branches. Their ideal indicated value equals the voltage of this altered circuit; voltmeter loading can exist even with perfect measurement calibration. Real readout additionally has measurement uncertainty, offsets, and finite resolution. Consult the actual range and input specifications rather than assigning every digital multimeter the same .
For an oscilloscope, the resistance-only model applies to settled direct current with a compatible input coupling setting. The oscilloscope input and cable also have capacitance; changing signals can therefore have loading that depends on frequency. A probe changes the impedance seen at its tip and the relation between tip voltage and displayed voltage; use the probe-and-input combination's specification and attenuation setting. NJIT's guide models the parallel electrical resistance and capacitance and adjusts probe compensation with a square-wave readout.[ref]
Voltage divider Created 2026-10-13 Updated 2026-10-14
A voltage divider uses two resistors connected in series to obtain a fraction of an applied electric potential difference. Let the upper electrical resistance be , the lower one , and the input be relative to a common electrical reference potential. The output is the junction's electric potential difference relative to that same reference, across . The familiar ratio assumes zero output electric current: no external electrical load draws from the junction. In a steady direct current model with fixed resistors obeying Ohm's law and an ideal voltage source,
Here is the open-circuit voltage; correspond to in the header formula. With no junction branch, Kirchhoff's current law makes the same electric current pass through both resistors, and Ohm's law gives the two voltage drops. For , division gives ; if , the predicted output is zero but this ratio is undefined.
An original stipulated example has and . With zero output electric current, and . An attached electrical load instead gives ; a load gives . These are exact model predictions, not measured readings or specifications of a particular multimeter or oscilloscope.
Figure 1.
The same voltage divider has three different predicted outputs as the attached load changes
. Original circuit and readout comparison for ideal input and two resistors. Each finite connects across ; the displayed numbers are model predictions with ideal readout, not experimental data. Source. Details.
The divider is useful for scaling a voltage or converting a change in a sensor's electrical resistance into an electric potential difference. Its beauty is also its trap: multiplying both electrical resistances by the same positive factor preserves the unloaded ratio, but changes the effect of any fixed electrical load. A divider therefore supplies a predictable ratio under specified loading conditions; it is not a source that maintains that voltage for arbitrary output electric currents. A Wheatstone bridge compares two divider junctions, while Thévenin's theorem describes the divider's response to many different loads.
Southern Illinois University's ET 304A guide, Lab 4: Voltage Measurements and Meter Loading Effects, documents an instructive test: build equal-arm voltage dividers on a supply, then measure across the lower arm with a digital multimeter, analog multimeter, and oscilloscope. Starting with two resistors, repeat with equal pairs from to . It requires separate recorded readings, unloaded predictions, and predictions including each instrument's input electrical resistance. The guide obtains meter resistances from specification sheets and scope resistance from the input-panel marking. Equal ratios control the unloaded target while changing susceptibility to voltmeter loading. The provided tables are blank: the guide specifies a procedure, not measured outcomes.[ref]
Preparation and accuracy checks are made concrete by Berkeley's Lab 1: Introductory Experiments and Linear Circuits I. Its different divider uses nominal and resistors and a supply on a breadboard. Measure isolated resistors first, record actual supply voltage, recalculate with these measured values, then record the junction voltage with the digital multimeter. It explicitly compares actual values with resistor tolerance and the final voltage with a range-dependent accuracy bound from the instrument manual. This is an uncertainty check, not an independent measurement calibration.[ref]
For a controlled comparison, additionally record the selected instrument range, probe factor, and input coupling; connect each instrument separately to the same electrical reference potential, and monitor the input rather than treating the supply label as an exact voltage. These are proposed controls for interpreting the documented procedures. A voltage indication and a resistance indication from the same digital multimeter do not independently validate its measurement calibration; a traceable reference comparison would be needed for that. Resistor tolerance describes component variation, while measurement uncertainty describes what is known about measured values. Using nominal arms alone can confuse mismatch with loading: equal nominal arms each within one-percent tolerance can give unloaded ratios from to .
The inference to test is specific: once actual arm values, input voltage, and meter input electrical resistance are accounted for, the readout should approach the loaded voltage divider prediction within the remaining measurement uncertainty. A discrepancy can instead reflect contacts, changing temperature, source droop, or an input that is not a fixed passive resistor. A source with positive series electrical resistance can be modeled by replacing with only when denotes its ideal internal voltage; when the actual voltage across the divider is measured, that terminal value is already . During settling, or with appreciable input capacitance and changing signals, the steady direct current calculation is insufficient. Neither institutional procedure supplies measured values for the original example above.
Voltmeter loading 2026-10-14
Voltmeter loading is the change in an electric potential difference caused by the electric current drawn by the measuring voltmeter.
For a loaded voltage divider in steady direct current, a voltmeter connected across the lower resistor places its finite input electrical resistance in parallel with the lower arm's electrical resistance and any intended electrical load of electrical resistance . With positive, fixed electrical resistances, an upper resistor of electrical resistance , and an ideal voltage source supplying electric potential difference , Kirchhoff's current law and Ohm's law give
Here is the connected circuit's electric potential difference across the voltmeter; omit if there is no intended electrical load. The parallel connection and need for large input electrical resistance are standard voltmeter operating principles.[ref]
Voltmeter loading is a bias relative to the target electrical circuit with the voltmeter absent and any intended electrical load still present. Voltage divider loading error instead compares the attached-load output with the wholly unloaded output. An accurate readout of , supported by measurement calibration, can still differ from either target: calibration accuracy concerns the indication of the connected electric potential difference, whereas voltmeter loading changes that electric potential difference itself.