Angular magnification 2026-10-14
Angular magnification is the ratio of the signed viewing angle with an optical instrument to the signed viewing angle in a stated reference arrangement. Measure both as apparent directions from the eye, positive toward the same side of the optical axis; then an inverted view has negative . If only positive angular sizes are compared, the result is and carries no orientation information. [ref]
https://openstax.org/books/college-physics-2e/pages/26-5-telescopes. Urone and Hinrichs, College Physics 2e, §26.5: Telescope angular magnification and inversion
.For the upright virtual image of a converging thin lens, let the eye be at and take the unaided reference to be the same small object at a distance from the eye. Within the small-angle approximation,Specify : keeping the object in its original position means , whereas the customary magnifier rating uses a near-point reference, often . A reference distance is a convention, not a claim that every eye has that near point. [ref]
https://openstax.org/books/university-physics-volume-3/pages/2-7-the-simple-magnifier. Ling, Sanny and Moebs, University Physics Volume 3, §2.7: Angle ratio and viewing distances
.For the virtual image diagram, , and . With , , whereas keeping the object at gives . Thus neither viewing comparison gives the transverse magnification four. A person may also be unable to focus on the unaided object at the shorter reference distance.
At , each outgoing bundle is parallel with slope ; its apparent viewing direction has angle . Consequently remains finite even though is undefined at a finite image plane. Equivalently, in the limit , the factors and both grow without bound but their ratio tends to . For and , the relaxed-view prediction is . [ref]
https://openstax.org/books/university-physics-volume-3/pages/2-7-the-simple-magnifier. Ling, Sanny and Moebs, §2.7: Image at infinity
. Aperture Created 2026-10-05 Updated 2026-10-13
An aperture is an opening that admits light into or through an optical instrument. Its shape and size select the transmitted light rays; an aperture alone does not bend them as an optical lens does. The aperture stop is the opening that most restricts the bundle from an on-axis object point. The entrance pupil is the image of that aperture stop formed by the preceding optical lens elements, viewed from the object side. Consequently the effective collecting diameter is the entrance pupil diameter, which can differ from the physical hole's diameter. For example, preceding optical lens elements that enlarge a aperture stop by a factor of two give ; measuring the physical hole alone would misidentify the focal ratio. [ref]
https://www.rp-photonics.com/entrance_and_exit_pupil.html. Rüdiger Paschotta, RP Photonics Encyclopedia, Entrance and Exit Pupil
.For an unobscured circular entrance pupil under a uniform beam normal to its plane, the collecting area and admitted radiant flux arewhere is incident irradiance. Doubling quadruples admitted radiant flux. Obstructions, nonuniform illumination and losses after the entrance pupil require the actual illuminated area and transmission to be included. The same also sets an angular diffraction-limited resolution scale at wavelength . Collection and diffraction therefore answer different questions from field of view: an aperture selects the bundle from each object point, while the receiving plane's extent helps select which object directions appear in the image.
NASA/JPL's published pinhole demonstration uses two white cards, foil taped over a window in one card, and a small hole pierced in the foil. Sunlight passes through the hole onto the second card; the projected image is viewed on that card. The activity describes a larger image when the card separation increases, improved visibility when the receiving card is shaded, and a separate image from each of several holes. These are qualitative observations of image formation, rather than calibrated measurements of radiant flux or diffraction. [ref]
https://www.jpl.nasa.gov/edu/resources/project/how-to-make-a-pinhole-camera/. NASA/JPL Education, How to Make a Pinhole Camera, apparatus and projection observations
.A proposed quantitative extension replaces sunlight by a steadily illuminated asymmetric target and puts the foil and a translucent receiving screen in a dark box. Record target distance , hole-to-screen distance , hole diameter , image height, orientation and edge blur. Measure screen brightness with a fixed photodetector, or record the screen with an optical camera whose integration time and gain stay fixed. Exchange centred foils of measured at fixed ; then vary with the same foil. Geometrical optics predicts an inverted image with transverse magnification and a point's geometric blur diameter . Thus a larger hole admits more radiant flux without changing the central image scale, whereas increasing enlarges the image. These are predictions to test, not reported data. Keep target illumination and detector position fixed, subtract a hole-covered dark reading, repeat the original foil to check drift, and avoid clipping the detector response. Foil thickness and ragged edges can block oblique light rays; at sufficiently small , diffraction invalidates the claim that ever smaller holes always sharpen the image. A lensless optical camera has no optical lens focal length: is a propagation distance, not that focal length.
Area-angle tradeoff 2026-10-14
When both endpoint bundles have the filled circular-cone geometry of etendue of a circular aperture and cone, conservation of etendue givesFor the same refractive index, quadrupling the area halves the sine of the cone half-angle. In the , example, an ideal output of diameter must have , so . The exact result differs from simply halving . Conversely, reducing the diameter to requires a complete forward hemisphere, , as a limiting case.
Equal bounding area and solid angle do not alone prove equal etendue: an actual output can have unoccupied directions or position-direction correlations. The filled-cone equation is an exact model of the specified bundles and a capacity constraint on an optical instrument, not a guarantee of an aberration-free implementation.
Beam splitter Created 2026-10-05 Updated 2026-10-14
A beam splitter is an optical instrument that routes an incident beam of light into transmitted and reflected beams. It also combines incident complex amplitudes: two inputs can contribute to the same output. A common geometry has four optical ports, with two chosen as inputs and two as outputs. A beam splitter changes the field; a photodetector supplies a measurement.[ref]
Photon quantum mechanics and beam splitters by Charles H. Holbrow and others. Photon quantum mechanics and beam splitters, §IV, printed p. 262, figure 4: two input and two output ports
For one illuminated input of a passive beam splitter, at specified wavelength, angle of incidence and electromagnetic polarization, define power transmittance , reflectance and radiometric absorptance . In steady operation, with no gain or other source, no net stored energy change, and all escaping light included in the transmitted or reflected collection,This is conservation of energy divided by incident power. If and count only the intended output beams, include a separate scattered or otherwise uncollected fraction : then . Missing output power need not be wave absorption. For an original specified example, , , and give transmitted, reflected and absorbed; these are assumed values, not measurements.
A 50:50 beam splitter specifies equal output powers for one input, not equal complex amplitudes without a relative wave phase. Recombination needs the beam splitter scattering matrix, including its wave phases. A nonpolarizing beam splitter approximately divides both orthogonal linear polarizations in the same power ratio over its specified operating range; a polarizing beam splitter deliberately routes the two differently.
The useful surprise is that the same component divides power with one input and steers power by wave interference with two inputs. In a Michelson interferometer or Mach-Zehnder interferometer, mirror motion changes relative wave phase, turning a small change in optical path length into a measurable change in output power.
Coronagraph Created 2026-10-06 Updated 2026-10-13
A coronagraph is an optical instrument that suppresses a bright source's light before detection while transmitting some light from nearby directions. Its purpose is to reveal faint structure buried in the bright source's point spread function, as in exoplanet direct imaging. A Lyot coronagraph combines a coronagraphic focal plane mask with a Lyot stop in a reimaged optical pupil; blocking the central image alone does not remove its diffraction rings. [ref].
The four principal planes of a Lyot coronagraph: a focal plane mask and a reimaged optical pupil stop select different parts of the wave amplitude distribution. Qualitative schematic, with illustrative sizes and brightness.
Details. The original motivation was the solar corona: hiding the bright photosphere would allow longer, repeated observations of faint surrounding light. In his 1930 paper, Lyot explained that short total eclipses restricted observing time and prevented some long exposures for spectral lines. The attraction is an instrument that makes the faint neighborhood accessible on demand. [ref]
https://www.persee.fr/doc/bastr_0245-9760_1930_num_6_1_14031. Bernard Lyot, La couronne solaire étudiée en dehors des éclipses, 1930, p. 305
. The Sun is an extended source; the point-source calculation below illustrates imaging of an unresolved star and is not a quantitative model of the solar corona. Etendue Created 2026-10-06 Updated 2026-10-14
Etendue measures how much position-and-direction space a bundle of light rays occupies. A small spot accepting a wide range of directions can have the same etendue as a large spot accepting a narrow range. This makes etendue useful for deciding whether an optical instrument can deliver an extended source's entire admitted radiant flux to a small receiver. For forward crossings of a surface, the geometrical optics definition iswhere is the occupied set of surface positions and directions, is the local refractive index, is actual surface area, is solid angle, and is the angle to the forward unit normal. The cosine supplies the projected area. Opposite crossing directions must be counted separately with positive projected area, rather than cancelling them in a signed integral. [ref]
Étendue (Photon Snacks) by R. John Koshel. Étendue, p. 1, equation (1.1): refractive-index-weighted projected-area integral
The shorthand assumes constant refractive index, a narrow nearly normal bundle, and the same admitted directions across the whole area . At larger angles, use the cosine-weighted integral; a position-dependent angular acceptance cannot generally be replaced by the product of two independent extents.
Field of view Created 2026-10-05 Updated 2026-10-14
The field of view is the region of object directions sampled by an optical instrument in one pointing. State whether it is horizontal, vertical or diagonal, and whether it is a full angle or a half-angle. An object-plane width in millimetres also describes a field of view, but requires a specified object distance. Neither that width nor the angular field of view is the aperture diameter or the diffraction-limited resolution.
For a centred flat rectangular photodetector of width in the focal plane, with positive effective focal length , infinity focus and ideal rectilinear imaging without optical distortion, the full horizontal field of view isThe model maps an object direction to image height of magnitude ; set and use the inverse tangent. This retains exact right triangle geometry within the stipulated imaging model; a paraxial focal length alone does not guarantee that a real wide-field optical lens obeys it. With detector height , replace by for the vertical field of view, and by for the diagonal field of view. The small-angle approximation gives in radians. [ref]
https://www.edmundoptics.com/knowledge-center/application-notes/imaging/understanding-focal-length-and-field-of-view/. Gregory Hollows and Nicholas James, Edmund Optics, Understanding Focal Length and Field of View
.For an original worked example, a detector width gives at , and at . Keeping makes these f/2 and f/4 respectively: the field of view changes because changes. By contrast, closing from to at changes f/4 to f/8 while retaining in this model. The clean separation is useful: entrance pupil area controls collection, focal ratio controls the paraxial cone, and controls angular image coverage. Edge clipping, optical distortion, field curvature and optical aberrations can restrict the practically usable field of view.
A proposed angular readout on an optical bench illuminates a small asymmetric target at the optical focus of a collimator, providing a bundle with a known direction. Rotate the optical camera about the centre of its entrance pupil, reading a graduated rotation stage, and record the target image position on its fixed photodetector. Centre the target to establish zero; turn left and right until its centre reaches each detector edge. The difference between stage readings measures the full horizontal field of view. Repeat with a smaller aperture stop: unchanged edge directions but reduced signal support the distinction between collection and angular coverage. Keep the same active detector width, infinity focus, illumination, integration time and gain; approach each reading from the same direction to check mechanical backlash. A finite target blurs the edge criterion, detector thresholds can imitate lost coverage, and a wide bundle must illuminate the whole entrance pupil at every tested angle. These checks distinguish a geometrical boundary from insufficient signal. The analytical diagram is the prediction for this protocol, not a record of its execution.
Focal ratio Created 2026-10-06 Updated 2026-10-18
The focal ratio, or f-number, of a converging optical instrument focused at infinity is the dimensionless quantitywhere is effective focal length and is the on-axis entrance pupil diameter. The notation f/4 means , not in a particular unit. A focal length with gives f/4. Closing the aperture stop until gives f/8 while retaining the same focal length. The mechanical opening need not equal . [ref]
https://www.edmundoptics.com/knowledge-center/application-notes/imaging/lens-iris-aperture-setting/. Gregory Hollows and Nicholas James, Edmund Optics, System Throughput, f-number, and Numerical Aperture
.For a thin lens in air with a circular aperture stop at the thin lens, the converging bundle from a distant on-axis point has half-angle satisfyingThe last step uses the small-angle approximation. For a compound optical lens, the cone is set by the image-side optical pupil and its distance from the receiving plane; the simple triangle is not an exact high-angle rule. At finite object distance a thin lens instead gives , by its imaging equation and transverse magnification, so its working cone corresponds to . Nominal focal ratio therefore does not alone specify close-range image irradiance. [ref]
https://www.edmundoptics.com/knowledge-center/application-notes/imaging/lens-iris-aperture-setting/. Hollows and James, working f-number and image-space cone
.Two useful scalings follow under stated conditions. For a fixed uniform incident beam and unchanged transmission, collected radiant flux scales as . For an extended source with fixed radiance, the central image irradiance scales approximately as in the paraxial approximation: the solid angle of the cone scales as . For an ideal uniformly illuminated unobscured circular entrance pupil, the first dark ring of the point spread function has angular radius and focal plane radiusHere is wavelength. These are first-zero radii, not diameters or a universal rule for resolving arbitrary objects. A proof outline evaluates the circular aperture's Fraunhofer diffraction using its Fourier transform, then uses the first zero of the resulting Bessel function. [ref]
Two-Dimensional Fourier Optics. Richard Fitzpatrick, University of Texas at Austin, Two-Dimensional Fourier Optics, circular-aperture first minimum
.At , the example's f/4 and f/8 first-ring radii are and . Closing the aperture stop halves , quarters collected radiant flux and doubles this diffraction radius. It can also reduce optical aberrations by excluding outer light rays; actual sharpness reflects both effects. This explains why a smaller aperture need not produce a sharper image. [ref]
https://www.edmundoptics.com/knowledge-center/application-notes/imaging/limitations-on-resolution-and-contrast-the-airy-disk/. Gregory Hollows and Nicholas James, Edmund Optics, The Airy Disk and Diffraction Limit
.Aperture and focal ratio: a common optical focus, reduced collection and increased diffraction radius
. Original analytical illustration. Left: equal-scale thin lens geometry with and or . Right: collected radiant flux relative to f/4 is , and first-ring radius relative to f/4 is . The wavelength is ; the entrance pupil is circular, uniformly illuminated and unobscured. These are calculated quantities, not measurements. Details.A proposed optical bench check puts a fixed collimator before a converging thin lens and a photodetector large enough to collect the entire image behind it. Compare two centred aperture stops of known diameters while fixing source output, detector gain and integration time. The integrated signal tests the collection law; a spatially resolved optical camera at the focal plane can separately measure the point spread function. Repeat a dark reading and the first aperture stop, and check that neither the incoming beam nor detector clips either bundle. A resolved pinhole source, imperfect collimation, optical aberrations and detector pixel size can dominate the apparent spot width; a single peak reading does not measure total collected radiant flux.
Free spectral range Created 2026-10-05 Updated 2026-10-14
The free spectral range is the wavelength or frequency spacing between adjacent orders or resonances of an optical instrument. It identifies when different orders can overlap. Always specify the coordinate: a uniform spacing in frequency need not be uniform in wavelength. For an ideal Fabry–Pérot interferometer at normal incidence, with mirror separation and constant refractive index , Fabry–Pérot resonance spacing gives , where is the speed of light in vacuum. The free spectral range of an echelle grating follows a different order condition.
Lens (optics) Created 2026-10-05 Updated 2026-10-24
An optical lens is a transparent element, or assembly of elements, that redirects a bundle of light rays to form images or change how the bundle spreads. In an ordinary glass optical lens, refraction at the surfaces provides the redirection: their changing normal vectors make Snell's law bend different light rays by different amounts. A converging optical lens brings incoming light rays parallel to its optical axis toward an optical focus; a diverging optical lens makes them spread as if from an optical focus on the incoming side. [ref]
https://openstax.org/books/university-physics-volume-3/pages/2-4-thin-lenses. Ling, Sanny and Moebs, OpenStax University Physics Volume 3, §2.4: Thin lenses
.For a usual glass thin lens in air, a form thicker at the centre than at the edges normally converges, with positive focal length; one thinner at the centre normally diverges. Shape alone is insufficient: the refractive index relative to the surroundings also matters, as the lensmaker's equation shows. An aperture selects which light rays pass; an optical lens also changes their directions. The distinction explains how an optical camera can gather light from one object point over many incoming directions and deliver it to one image location.
The beautiful simplification is that an entire bundle can be characterized by a focal length, and two constructed light rays can locate an image. The thin lens examples below turn that geometry into a prediction of image position, orientation and transverse magnification. A real optical lens retains optical aberrations and diffraction, so the construction is a useful leading model rather than an exact solution of Maxwell's equations.[ref]
Early mathematical treatments include Johannes Kepler's 1611 Dioptrice, whose title explicitly concerns vision through newly invented instruments using transparent glass, and René Descartes's 1637 La Dioptrique, whose seventh discourse discusses improving vision with shaped glass. These are landmarks in explaining and designing optical instruments, rather than dates for the invention of the optical lens. [ref]
https://www.e-rara.ch/zut/content/titleinfo/120202. Kepler, Dioptrice, 1611, original edition digitized by ETH-Bibliothek
; [ref]https://classiques.uqam.ca/classiques/Descartes/dioptrique/dioptrique.html. Descartes, La Dioptrique, 1637, seventh discourse, UQAM text edition
. Optical aberration Created 2026-10-05 Updated 2026-10-14
An optical aberration is a departure from ideal image formation: light rays from one object point may miss their intended common image point, or image positions may depart from the intended mapping. Spherical aberration, coma, and astigmatism describe different ways of spreading a point's light rays; optical distortion can change image shape without spreading each point. In physical optics, these departures can be described by wavefront error relative to a reference wavefront. Diffraction also gives a finite point spread function in a perfect optical instrument, so an extended image alone does not establish an optical aberration.
Optical port Created 2026-10-14 Updated 2026-10-25
An optical port specifies where and in which direction a beam enters or leaves an optical instrument. To attach one complex amplitude to it, also specify the beam's transverse field profile, electromagnetic polarization, frequency and reference plane for wave phase. Reversing propagation changes the input/output assignment. Four geometrical connections do not imply four independent input complex amplitudes in the chosen two-input configuration.
Optician (optical instruments) 2026-10-18