Coupled RL induction model 2026-10-18
Take two electrical circuits containing coupled inductors. Let their constant self-inductances be , mutual inductance , and positive electrical resistances . Choose current directions so that the off-diagonal entries of the inductance matrix are . Assume a linear, quasistatic model, with no capacitive effects or core hysteresis. The magnetic flux linkages are and . Combining their time derivatives with resistive electric potential differences givesThe secondary is a closed, undriven electrical circuit. Require , making a positive-definite matrix. The chosen current convention fixes the signs; reversing the secondary's reference direction changes the sign assigned to and without changing the physical circuit.
There is an essential switching assumption: the primary loop remains closed when becomes zero. An ideal voltage source then imposes zero electric potential difference, allowing the current to decay. Literally opening an inductive circuit requires additional physics to determine the interruption, including possible capacitance and an electric arc. This closed-return model explains transient induction while keeping that distinction from Faraday's historical making and breaking of contact explicit.
Electrical circuit Created 2026-10-05 Updated 2026-11-05
An electrical circuit is a network of components and connections used to transport electric charge and exchange energy. Resistors dissipate energy, capacitors store energy in an electric field, and inductors store energy in a magnetic field.
A lumped-element model represents the circuit by branch electric currents and terminal electric potential differences. Kirchhoff's current law expresses charge balance at connections, while Kirchhoff's voltage law relates the branch voltages around loops. [ref]
University Physics Volume 2 by Samuel J. Ling and others. Section 10.3, junction and loop rules, equations 10.4–10.5
For constant ideal components, with current entering the positive-voltage terminal,Combining these relations produces algebraic equations or time-dependent differential equations.For example, an RC circuit charging an initially uncharged capacitor from a fixed voltage source obeysThe product is its time constant. This transient connects energy storage to the rate of the circuit's response. [ref]
University Physics Volume 2 by Samuel J. Ling and others. Section 10.5, charging a capacitor, equations 10.8–10.10
When propagation along connections matters, a transmission line description can replace a single lumped model. Electrical test source 2026-10-14
A prescribed voltage source or current source used to probe a terminal response. For a suppressed linear resistive circuit, the ratio of terminal voltage to entering electric current determines the Thévenin resistance when finite.
Half-wave rectifier 2026-10-18
For an original ideal example, let an ideal voltage source supply the sinusoid , with and angular frequency . Connect its positive reference terminal to the diode anode, the diode cathode to the upper terminal of a load resistor with electrical resistance , and the lower terminal to the source return. Let be the upper-minus-lower load electric potential difference, and the downward load electric current. Assume the ideal diode model, zero source electrical resistance, and no filter capacitor, inductor or switching delay.
An ideal half-wave rectifier selects the positive half-cycle
. Original schematic and calculated load electric potential difference for and . The diode cathode is the bar at ; positive load electric current flows downward through the resistor. Dashed orange: source sinusoid. Blue: load output, zero during the negative half-cycle. Green: its cycle-average electric potential difference . No smoothing capacitor is present; these are ideal model predictions. Details.The Kirchhoff cycle law gives , and Ohm's law gives . If , the blocking assumption would give , contradicting the ideal diode model, so the diode conducts with . If , conduction would give , also forbidden, so the diode blocks. At the crossings both values vanish. ThusThe peak load electric current is . The output is unidirectional but still varies in time, reaching zero throughout every negative half-cycle. Over a period of a function , write the wave phase as . Its average value of a function and root mean square follow from two integrals:Consequently the average load power is , not . The ideal diode has zero loss; the resistor converts supplied energy into Joule heating. The same switching argument predicts when the diode is reversed. Directional selection changes the waveform and its average value of a function; it does not by itself produce a constant output.
Independent electrical source 2026-10-14
An ideal voltage source or current source whose prescribed value is not controlled by a variable in the connected electrical circuit.
Monolithic integrated circuit 2026-10-18
A monolithic integrated circuit has its circuit elements fabricated in or on one semiconductor die. Their connections are essential: an unconnected collection of transistors does not implement the intended electrical circuit.
An original ideal example separates function from fabrication. Connect two resistors, above , in a series circuit across an ideal voltage source. With no load electric current drawn from their meeting point, Ohm's law and the Kirchhoff cycle law giveThese equations apply to either a discrete circuit or an idealized monolithic integrated circuit realizing those same electrical resistances. Integration changes construction; the electrical circuit equations still determine the output. A real load, unwanted capacitance or finite resistor tolerance changes the ideal calculation. Manufacturing many functions together also couples their fate: a fatal defect can discard an entire semiconductor die, motivating the Poisson defect yield model.
An external source sees the input resistor between its terminal and the virtual ground. The input current is , soThe infinite input resistance of the ideal operational amplifier itself is distinct from the finite input resistance of the complete inverting amplifier. Negative feedback makes the output approach an ideal voltage source; a real amplifier retains a small nonzero output resistance.
The original diagram places in parallel with the inductor; connects their common node to the source only when the switch is in position 2. Let be their shared voltage and the downward inductor electric current. Since and a finite voltage cannot change it instantaneously, the inductor initially behaves as an open branch. ThusAt long times, an ideal inductor carrying constant electric current has , shorting . Therefore and .
For the full transient, Kirchhoff's current law gives with . Equivalently, the source seen by the inductor has the Thévenin equivalentSolving givesThe relevant resistance is the parallel combination with the ideal voltage source suppressed, not and not alone.
Current redistribution when the solenoid is connected and disconnected
. The two panels use their own time origins. On connection the inductor current grows while the parallel-resistor current decays. On disconnection both branches carry equal and opposite currents as stored magnetic energy dissipates. Details.The positive lamp power comes from extra work by the primary current source. The secondary electric current creates a changing magnetic flux through the primary, so maintaining the same prescribed primary electric current requires an additional terminal voltage. With the preceding winding convention,Using phasors, , hence the primary sees the complex impedanceIt follows directly thatThis is the reflected impedance of the secondary load. The self-inductance and mutual inductance terms exchange stored magnetic energy, while the lamp dissipates it. Multiplying the two coupled equations from Kirchhoff's voltage law by their respective electric currents also gives the instantaneous conservation of energy identityThe derivative averages to zero in periodic steady state. A fixed primary current source supplies the required extra voltage; a fixed voltage source would generally change its primary electric current when the lamp is connected.
RC low-pass output loading 2026-10-18
A real electrical load can draw electric current from the output. For a load resistor across the capacitor, Kirchhoff's current law instead givesTherefore the loaded continuous-time frequency response isLoading reduces the eventual gain and shortens the time constant. With the constructed values and , , , and the corner relative to the loaded low-frequency gain moves to . A step now approaches . A quicker rise alone would conceal the error in the final voltage.
With the ideal input voltage source set to zero, the output impedance seen by the electrical load isThis follows from Thévenin's theorem: the resistor and capacitor are then in parallel. A sufficient small-loading condition is over the frequencies of interest. An oscilloscope is itself an electrical load: its input electrical resistance and cable or probe capacitance can both change the response. Pure extra parallel capacitance increases and lowers the corner, whereas a finite parallel electrical resistance gives the different gain-and-corner changes above.
The definition of input also matters. If voltage is prescribed inside a source with series electrical resistance , the unloaded response to that internal source uses . If the actual voltage at the filter input terminal is measured, the ratio of output to that measured input still uses . Measuring both terminals avoids mistaking a source setting for the voltage delivered to the filter.
An ideal voltage source and series resistor feed parallel branches and . Thévenin's theorem gives and . Starting with zero inductor current, and . Switch-on heat in is . Disconnecting the source leaves the stored magnetic energy to dissipate through , with time constant .
Thermal noise spectral convention 2026-10-18
Model an ideal resistor of constant electrical resistance at uniform absolute temperature by its Thévenin equivalent: a zero-mean random voltage source in series with a noiseless . In the classical range its one-sided, open-circuit voltage power spectral density, per hertz, iswhere is the Boltzmann constant. Thus a positive-frequency interval of width contributes to the mean square voltage. This is approximately white noise only where the electrical resistance is effectively constant and , with the Planck constant. The ideal constant spectrum cannot describe arbitrarily high frequencies.[ref]
For a real voltage, an equivalent two-sided power spectral density is over signed frequencies. With a real linear time-invariant system of frequency response , the same output mean square isAngle brackets denote an expected value; for this zero-mean noise the mean square is its variance. Do not integrate over both signs of frequency: that counts the same fluctuations twice. All integrals here use frequency in hertz, not angular frequency . The amplitude spectral density is in , whereas the root mean square voltage requires a specified measurement signal bandwidth.
Thévenin divider example 2026-10-14
In the pictured original linear resistive circuit, the ideal voltage source keeps its upper node at relative to . Let connect that node to , and connect to . With the external electrical load removed, the voltage divider givesTo find the Thévenin resistance, Thévenin source suppression replaces the ideal voltage source by a wire. Both resistors now join to in parallel, givingThis is the electrical resistance looking into the original network with its independent electrical source suppressed; the external electrical load is excluded.
An independent check uses Kirchhoff's current law at , without suppressing anything:The Thévenin terminal response thus follows directly from the original topology. Shorting to in this ideal calculation gives : the lower resistor has zero voltage and the upper resistor limits the electric current. All numerical values here and in the figures are stipulated model values, not laboratory data.
Thévenin equivalent 2026-10-18
A Thévenin equivalent represents a network at two terminals by a voltage source in series with its Thévenin resistance. It reproduces the terminal relation under the assumptions of Thévenin's theorem.
Thévenin source suppression 2026-10-14
To determine the Thévenin resistance, remove the external electrical load and set each independent electrical source to zero in the circuit model. A zero ideal voltage source enforces zero electric potential difference, so replace it by a short connection. A zero ideal current source enforces zero electric current, so replace it by an open connection. Retain every resistor, including any explicitly modeled supply electrical resistance. Turning an actual power supply's front-panel control to zero is not evidence that it physically becomes an ideal wire.
Retain every dependent electrical source and its controlling variable: its response to an electrical test source is part of the network's electrical resistance. Impose terminal voltage with an electrical test source and calculate entering the suppressed network at . For a nonzero test yielding a finite ratio,Alternatively inject a known entering electric current and solve for . The test electric current is opposite to the delivered-current convention of the original Thévenin terminal response. [ref]
Thevenin and Norton Equivalents, University of Houston teaching notes. Thevenin and Norton Equivalents, pp. 5–7, “Test Source Method for RTH” and Notes: suppress independent sources, retain dependent sources
For an original illustration, put a positive resistor across and a dependent electrical source in parallel that injects electric current from toward , where has units of electrical conductance. Its control is the same terminal voltage . Kirchhoff's current law givesWith and , a test draws , giving . Removing the dependent electrical source would falsely give . With , the model instead has ; with it draws zero test electric current for any imposed voltage and has no finite ratio. An active physical realization requires a supply and has a limited operating range.
For a finite nonzero and a well-defined short-circuit response, . Thus is usable when . A source-free positive resistor has both and , so this quotient cannot reveal its electrical resistance; an electrical test source can.
Thévenin's theorem Created 2026-10-13 Updated 2026-10-14
Thévenin's theorem replaces the terminal behavior of a linear resistive circuit by an ideal voltage source in series with a Thévenin resistance, whenever its terminal electric potential difference is a well-defined affine function of the delivered electric current. Fix terminals , write , and take positive out of the network at into the electrical load, returning through . ThenThe open-circuit voltage is the intercept at ; is the slope. Thus two parameters predict what happens when many different electrical loads are connected. The Wheatstone bridge detector loading calculation uses precisely this replacement to find the detector reading even when the bridge's two voltage dividers interact through its detector.
For example, a ideal voltage source with above and below a voltage divider junction supplies and at that junction relative to the lower terminal. Attaching a electrical load reduces its voltage to and draws . The equivalent explains why an unloaded divider ratio alone cannot predict a loaded output.
The equivalence concerns the chosen terminals, including the power delivered there. It does not identify internal branch electric currents or internal Joule heating. At open circuit the original divider still draws from its supply, while the equivalent's series branch carries no electric current. [ref]
Thevenin and Norton Equivalents, University of Houston teaching notes. Thevenin and Norton Equivalents, pp. 1–2, “The Idea” and “Important Notes”: equivalence at the specified terminals
Thévenin terminal response 2026-10-14
With the passive sign convention applied to the network, its entering electric current is , and the same relation becomes . The electrical load uses the passive sign convention with entering electric current , so it absorbs power . A positive delivered electric current therefore produces a voltage drop for positive ; changing the reference direction without changing the equation would give the wrong sign.
The reason is linearity of Ohm's law, Kirchhoff's current law, Kirchhoff's voltage law, and the constitutive relations of any linear dependent electrical sources. Solve once at with the independent electrical sources present. Subtract this solution from a solution with prescribed delivered electric current : the fixed independent electrical sources cancel, leaving a homogeneous linear network whose terminal voltage change is proportional to . This is a short superposition principle argument for an affine function; the fixed offset need not vanish.
The qualification about a well-defined response matters. An ideal voltage source alone has . An ideal nonzero current source alone constrains and does not have a finite open-circuit voltage or a representation with finite coefficients. Linear dependent electrical sources can give negative resistance, and singular ideal networks may fail to have a unique finite response. Neither a finite nor a strictly positive passive follows merely from calling an electrical circuit linear. [ref]
Thevenin and Norton Equivalents, University of Houston teaching notes. Thevenin and Norton Equivalents, p. 11, “On a Negative Thevenin Equivalent Resistance”: dependent-source models can have negative equivalent resistance
Tunnel-diode load-line stability 2026-10-18
A current-voltage characteristic determines possible steady operating points; it does not alone determine their linear stability. Consider an ideal voltage source feeding a tunnel diode through a resistor , with a positive constant capacitance across the junction. Assume a quasistatic device relation and neglect inductance, transit delays, noise and heating. Kirchhoff's current law gives the original one-state modelA steady operating point satisfies : the device curve intersects the descending supply line. This is the source-side counterpart of a resistive load line. A small perturbation obeysThus the equilibrium point is locally attracting if and unstable if the inequality reverses. Equality requires higher-order analysis. Even on a negative differential resistance segment, a sufficiently small supply electrical resistance can stabilize this model. The assumption about the electrical circuit matters: an inductive or delayed circuit has additional state variables and may behave differently.
Choose an original toy forward characteristic, with no fitted device parameters:where , and . For every , , so this entire forward curve absorbs positive total power. NeverthelessThe model therefore separates negative differential resistance from negative total . The corresponding peak and valley are at approximately and ; these voltages deliberately differ from the historical peak.
With and , the supply line is . The intersection equation factors exactly:The three operating points are , and . Their values of are respectively , and . The outer two attract nearby trajectories; the middle one repels them. This is bistability in the specified one-state electrical circuit.
For the second panel, choose and . Now andThere is exactly one real operating point, again . Here , despite the device's own slope . With , the perturbation decays with time constant ; the unstable middle point of the first panel has growth time .
The one-state autonomous model supports switching between attracting operating points after a perturbation or parameter change; it cannot produce a nonconstant periodic orbit. A proposed oscillator needs additional dynamics. This limitation is useful: a load-line intersection establishes a possible steady reading, the slope test establishes local attraction in a specified model, and neither calculation alone predicts an oscillation frequency for a real tunnel diode.
Voltage divider Created 2026-10-13 Updated 2026-10-14
A voltage divider uses two resistors connected in series to obtain a fraction of an applied electric potential difference. Let the upper electrical resistance be , the lower one , and the input be relative to a common electrical reference potential. The output is the junction's electric potential difference relative to that same reference, across . The familiar ratio assumes zero output electric current: no external electrical load draws from the junction. In a steady direct current model with fixed resistors obeying Ohm's law and an ideal voltage source,Here is the open-circuit voltage; correspond to in the header formula. With no junction branch, Kirchhoff's current law makes the same electric current pass through both resistors, and Ohm's law gives the two voltage drops. For , division gives ; if , the predicted output is zero but this ratio is undefined.
An original stipulated example has and . With zero output electric current, and . An attached electrical load instead gives ; a load gives . These are exact model predictions, not measured readings or specifications of a particular multimeter or oscilloscope.
The same voltage divider has three different predicted outputs as the attached load changes
. Original circuit and readout comparison for ideal input and two resistors. Each finite connects across ; the displayed numbers are model predictions with ideal readout, not experimental data. Source. Details.The divider is useful for scaling a voltage or converting a change in a sensor's electrical resistance into an electric potential difference. Its beauty is also its trap: multiplying both electrical resistances by the same positive factor preserves the unloaded ratio, but changes the effect of any fixed electrical load. A divider therefore supplies a predictable ratio under specified loading conditions; it is not a source that maintains that voltage for arbitrary output electric currents. A Wheatstone bridge compares two divider junctions, while Thévenin's theorem describes the divider's response to many different loads.
Voltmeter loading 2026-10-14
Voltmeter loading is the change in an electric potential difference caused by the electric current drawn by the measuring voltmeter.
For a loaded voltage divider in steady direct current, a voltmeter connected across the lower resistor places its finite input electrical resistance in parallel with the lower arm's electrical resistance and any intended electrical load of electrical resistance . With positive, fixed electrical resistances, an upper resistor of electrical resistance , and an ideal voltage source supplying electric potential difference , Kirchhoff's current law and Ohm's law giveHere is the connected circuit's electric potential difference across the voltmeter; omit if there is no intended electrical load. The parallel connection and need for large input electrical resistance are standard voltmeter operating principles.[ref]
10.4 Electrical Measuring Instruments. §10.4, Measuring Voltage with a Voltmeter: parallel connection and large input resistance
Voltmeter loading is a bias relative to the target electrical circuit with the voltmeter absent and any intended electrical load still present. Voltage divider loading error instead compares the attached-load output with the wholly unloaded output. An accurate readout of , supported by measurement calibration, can still differ from either target: calibration accuracy concerns the indication of the connected electric potential difference, whereas voltmeter loading changes that electric potential difference itself.