Seismic parameter 2026-10-20
Seismic velocity 2026-10-25
The propagation speed of a seismic disturbance, depending on elastic properties, density, composition, temperature and microstructure.
Selection-normalized astronomical likelihood 2026-10-20
For population parameters and an inclusion region in measured-data space, a selected datum has density . The normalization integrates the noisy measurement model and population over the actual selection region. Inference must also specify what is conditioned on: deterministic selection information already contained in the conditioned data must not be counted twice.
Shear-wave impedance 2026-10-25
The product of bulk density and S wave speed. At a normal-incidence boundary it controls the corresponding stress-amplitude reflection coefficient.
Slab buoyancy 2026-10-25
Net gravitational effect of thermal and compositional density contrasts between a slab and its surroundings, including phase changes.
Slump test for yield stress Created 2026-09-24 Updated 2026-11-05
A slump test for yield stress probes a material by allowing a molded sample to deform under its own weight. Fill a known mold on a level support, remove the mold, and measure the decrease in height or the spread of the final deposit. Gravity supplies the driving stress; resistance associated with the yield stress can arrest the motion before the sample becomes a thin layer.
The measured distance is not itself a stress. Inferring yield stress requires a calibrated relation or a mechanical model using the initial geometry, final shape and density. The final slump alone generally cannot identify both yield stress and dynamic viscosity: a time-resolved measurement provides additional information. A modified concrete test, for example, records the time required for a specified fall as well as the final slump.[ref]
Modified Slump Test to Measure Rheological Parameters of Fresh Concrete. pp. 241–247, abstract and apparatus: final slump and additional time measurement for rheological parameter estimation
The procedure is useful as a simple field measurement, with interpretation dependent on sample history and geometry. Soil-particle density 2026-11-05
Soil-particle density compares dry particle mass with the volume assigned to the particles themselves:Spaces between particles are excluded from . By contrast, the denominator of soil bulk density includes those spaces. A measurement must specify how particle volume is determined, especially when the particles themselves contain pores.[ref]
ISO 11508:2017 Soil quality: Determination of particle density. Scope; section 3.1, definition and volume convention
One measurement principle uses a pycnometer: determine the dry sample mass, then infer its volume from the displaced liquid mass and the liquid's density. Trapped gas, access to internal pores and the chosen volume convention matter when interpreting the displacement. The standard distinguishes fine soil from gravel and stones, and its stated particle-volume convention includes internal particle pores while excluding spaces between particles.[ref]
ISO 11508:2017 Soil quality: Determination of particle density. Sections 3.1 and 4.1.1, definition and fine-soil measurement principle
A constructed mixture shows why particle composition matters. Assume additive volumes, no internal pore complication, and two kinds of particles with densities and . Equal masses of occupy and , respectively. The combined soil-particle density israther than the arithmetic mean . For mass fractions and constituent densities , the same additive-volume model gives .
For compatible volume conventions, a particle-and-pore model relates the two densities to porosity:This identity requires the same dry mass in both density definitions. An assumed soil-particle density therefore makes the derived porosity an estimate under that assumption, rather than an independent measurement of pore volume.[ref]
ISO 11508:2017 Soil quality: Determination of particle density. Scope, particle density used with bulk-density measurements to calculate porosity
Solar model 2026-10-25
A model of the Sun obtained from stellar structure equations with specified composition, opacity and energy generation. Uniform density is useful for scale estimates but cannot reproduce the strong central concentration.
Sparse labelling Created 2026-10-20 Updated 2026-11-05
Labelling few enough founder cells to resolve individual clones. The acceptable density depends on spatial mixing, label diversity and the chance of independent activation.
Spatial weighting of nail-clipping exposure records determines how much each region of a clipping contributes to a pooled chemical measurement. A concentration reported per unit nail mass is a mass-weighted average. Equal lengths of nail plate need not supply equal amounts of material if width, thickness or density differs.
Let be mass per unit length at collection and the retained concentration per unit material mass. For a clipping spanning , an original ideal recovery model givesThis assumes complete, composition-independent recovery by the assay. If recovery varies spatially, the measurement equation requires that additional weighting.
For two equal-length regions with masses 1 and 3 mg and stipulated concentrations 0 and 100 units per mg, the pooled concentration is units per mg. A length-weighted average would give 50 and answer a different question. The numerical example illustrates geometry and normalization, not an observed exposure.
Mass-normalized temporal kernels for nail clippings arise when positions are converted into earlier reference-crossing times. If is the material map at collection, the normalized time weighting isAt constant advance speed and uniform line density, the kernel is rectangular, recovering temporal averaging in nail clippings. Variable material geometry or speed changes its shape. A growth experiment following file marks measures displacement over a known interval, not this entire weighting function.[ref]
A practical study retains segment orientation and measures the material amount used in each assay. Pooling several digits introduces further weights and potentially different growth histories. Wet-mass and structural-mass normalization also differ when water content changes, connecting the issue to hydration versus production in nail mass balance. Specify the denominator and material-to-time map before assigning a pooled concentration to one exposure date.
Specific strength Created 2026-10-20 Updated 2026-11-05
Specific strength is strength divided by density, with the strength convention stated explicitly. For a uniform tie carrying tensile force , allowable stress requires area . Its mass is therefore at least . Maximizing minimizes mass under this simple strength-limited model. A material with higher strength can still be worse if its density increases more. Mechanical fatigue, buckling, joining and temperature limits can impose additional constraints not captured by this single ratio.
Spherical Thomas–Fermi condensate Created 2026-10-20 Updated 2026-11-05
For repulsive contact interactions in a three-dimensional isotropic harmonic trap, neglecting the kinetic term in the Gross–Pitaevskii equation gives inside and zero outside. Normalization yields , hence and , with oscillator length . The density is parabolic but the wavefunction is its square root. Neglected kinetic energy rounds the edge and supplies a tail.
Spherical top-hat collapse model Created 2026-10-20 Updated 2026-10-25
A uniform overdensity evolves as a separate spherical pressureless region until shell crossing. In an Einstein-de Sitter background, formal collapse has linearly extrapolated threshold . This is distinct from the actual nonlinear density. Virialization and nonspherical tides require further physics.
Take , , constant density gradient , and meridional eddy density flux . If the divergence of the eddy momentum flux is zero, bounded Eulerian circulation and decaying residual mean circulation give with below zero and above, where and . The transformed streamfunction is , yielding the displayed and two oppositely rotating cells. Its jump represents a horizontal delta-function transport at the discontinuous flux termination. A smooth flux cutoff replaces that sheet by a thin regular return flow. Density flux alone does not determine either circulation if the momentum-flux divergence is left unspecified.
Stokes equation Created 2026-09-28 Updated 2026-10-14
For a steady incompressible flow of a Newtonian fluid with constant density and constant dynamic viscosity , neglecting inertia in the Navier-Stokes equation givesThe first equation is local force balance; the second is mass conservation. The term is the divergence of the viscous part of the Newtonian fluid stress tensor. The body force has units of force per unit volume, , and equals for uniform gravity. Appropriate boundary data for velocity or traction, together with suitable distant conditions for an exterior flow, complete the problem; a rigid surface normally imposes the no-slip boundary condition.
With uniform gravity, write where the hydrostatic pressure satisfies . Then the disturbance equation is . This removes gravity from the fluid disturbance equation, while the hydrostatic pressure still supplies buoyancy on an immersed body. Omitting it from the total force balance would give the wrong Stokes settling velocity.
Stokes flow Created 2026-09-24 Updated 2026-10-14
Stokes flow is the limit of fluid mechanics in which inertia is negligible: pressure gradients, viscosity and any body forces balance at each instant. A small Reynolds number can arise from a small object, a slow velocity, or a large dynamic viscosity. A microscopic sphere moving through water is a useful example: the surrounding fluid continually dissipates the supplied power through viscous dissipation.
The picture is a meridional slice of the three-dimensional axisymmetric flow around a sphere, with the sphere held fixed and the distant fluid moving rightward at speed . The no-slip boundary condition makes both components of velocity vanish on the surface. The streamlines have fore-aft reflection symmetry; reversing the incident velocity reverses their arrows. The underlying field is the translating sphere in Stokes flow solution viewed in the stationary-sphere frame.
For an incompressible flow of a Newtonian fluid with constant dynamic viscosity , the steady Stokes equation isHere is pressure, is velocity, and is body force per unit volume. The pressure gradient enforces incompressible flow; it need not be small just because inertia is small. At speed and length , the motion-induced pressure gradient has typical scale , corresponding to a disturbance pressure difference of order . See Shreyas Mandre's fluid dynamics notes, sections 9.1.1–9.1.2.
The controlling Reynolds number iswhere is density and is kinematic viscosity. The condition suppresses advection of momentum on the length . Rapid changes require an additional check of the viscous diffusion time: small Reynolds number alone does not eliminate the time derivative in the Unsteady Stokes equation.
Two rewards of this limit are the exact Stokes's law for the drag on a sphere and kinematic reversibility of Stokes flow. The first predicts settling velocities and connects to the Stokes–Einstein relation; the second explains why a microswimmer needs a nonreciprocal stroke, as expressed by the scallop theorem. Despite viscous dissipation, reversing the driving can retrace the motion: an especially striking consequence of Linearity of Stokes flow.
George Gabriel Stokes obtained the sphere drag and its terminal velocity in his 1851 investigation of how viscosity changes physical pendulum motion. He also used the slow fall of small water droplets to discuss clouds. The paper was read on 9 December 1850; 1851 is its publication date. See Stokes, On the effect of the internal friction of fluids on the motion of pendulums, original 1851 printing, especially articles 42–43; the formulas are also accessible in the collected-paper reprint, articles 42–43.
Stokes settling velocity Created 2026-09-28 Updated 2026-10-14
Sphere settling in water: terminal speed grows as radius squared while Reynolds number grows as radius cubed
. Details. Take downward as positive and let gravity have magnitude . For a rigid sphere of density in otherwise stationary fluid of density , its weight minus buoyancy is . At terminal velocity, this balances the Stokes drag law:This signed downward settling velocity is negative for a buoyantly rising sphere and zero for equal densities. For fixed density contrast and dynamic viscosity, the submerged weight grows as while linear drag at fixed speed grows as ; their balance gives the settling-velocity radius scaling . Meanwhile,Thus doubling the radius multiplies the predicted Stokes settling speed by four and the particle Reynolds number by eight. This makes the formula useful for separating particles by size, while also providing its own check against extrapolation to large particles.
For a computed water example, take , , , , and . These are specified rounded inputs rather than a claim of exact water properties at every temperature. They giveThe diameter is , and both the net downward weight and the upward drag force are . At this terminal velocity, falling takes . At the prediction is with ; at it is with , which is no longer a convincing small-Reynolds number case. The figure labels these as predictions of the Stokes settling velocity formula and shows where its inertia check fails.
The calculation describes the eventual terminal velocity, not the release transient governed by particle acceleration and possibly the Unsteady Stokes equation. Walls, hydrodynamic interactions, departures from a rigid sphere, or a different surface condition require a different resistance. For sufficiently small particles, Brownian motion can obscure individual settling trajectories; the formula still specifies the gravitational drift within its assumptions. The balancing argument already appears in article 43 of [ref]
https://mural.uv.es/daroig/documentos/stokes1850.pdf. Stokes's original investigation, collected-paper reprint
. Stokes's law Created 2026-10-14 Updated 2026-10-20
For an isolated rigid sphere of radius moving at velocity relative to a distant uniform Newtonian fluid, the drag force exerted by the fluid isThe assumptions are steady incompressible flow, constant dynamic viscosity , an unbounded surrounding fluid, the no-slip boundary condition, and a small diameter-based particle Reynolds number, . Integrating the surface traction in translating-sphere Stokes flow gives the factor : the disturbance pressure contributes to the drag magnitude and the viscous shear stress contributes . See Richard Fitzpatrick, Axisymmetric Stokes Flow Around a Solid Sphere, equations 10.120–10.129.
The result is linear drag: doubling doubles the drag force, and doubling at fixed also doubles it. The required power is , all supplied to viscous dissipation. Density enters the check of the particle Reynolds number, although it does not appear in the leading drag formula.
Nearby walls or other particles change the hydrodynamic resistance matrix and invalidate the isolated-sphere coefficient, even at very small Reynolds number. Finite Reynolds number introduces inertia corrections; the Oseen approximation resolves the distant region where the leading Stokes flow approximation ceases to be uniform. A clean gas bubble has tangential slip and instead obeys clean-bubble Stokes drag, with coefficient in its spherical, negligible-internal-viscosity limit. See H. K. Moffatt, Six Lectures on General Fluid Dynamics, section 3.4 for the sphere solution and its small-Reynolds number limitation. The continuum mechanics and boundary assumptions must also remain valid as the particle becomes very small.
Balancing this Stokes drag law against gravity and buoyancy gives the Stokes settling velocity of an isolated rigid sphere.
Streakline Created 2026-09-24 Updated 2026-10-13
A streakline at observation time is the set of present positions of all fluid elements that passed through one fixed release point during a specified history of injection. For continuous release over , solve a different initial value problem for each release time :Thus a pathline varies for one particle; a streakline varies while holding fixed. Interrupted release gives only the corresponding subsets of the streakline. A moving nozzle requires a time-dependent release position instead, so the standard fixed-point definition should not silently be applied to it. Continuous release makes streaklines easy to observe and useful for showing where material from one source has reached. [ref]
https://web.mit.edu/13.021/demos/lectures/lecture2.pdf. MIT Marine Hydrodynamics, lecture 2, section 1.2
In the analytical velocity field of pathline, a particle released at the origin at time followsObserve all particles together at time , after continuous release from :For , and , the streakline is the downward-curving parabola in metre coordinates. Releases at occupy , and , respectively. At , the streakline lies above the pathline and below the origin's streamline . All particles nevertheless have the same present velocity . The streakline slope generally differs from the present velocity slope ; they agree at the nozzle. The oldest particle is the downstream endpoint, which explains why the pathline and streakline meet there without being the same curve.
Each panel fixes one observation time. Coloured dots are the present positions of particles with the indicated release times; dashed pathlines show those particles' earlier histories. The black streakline connects present positions of the continuously released family, including release times between the sampled dots. After , particles already present keep moving and new ones enter at the origin, so the later streakline is not a frozen record of the earlier one. Injection beginning only at would show just of the curve. Both panels are diffusion-free analytical models, not experimental photographs.
Kline's contracting-channel demonstration switches from marking an element to continuous bubble production at a marking wire: the resulting trace is a streakline. The apparatus therefore changes the curve being displayed by changing the marking history, even with the same channel. A wire produces a family of traces; conceptually each fixed emitting location supplies its own streakline. Individual bubbles are markers rather than perfect fluid elements: Jean Hertzberg's teaching notes describe hydrogen production by electrolysis at a thin cathode wire and warn that larger bubbles have more buoyancy. [ref] [ref]
https://www.flowvis.org/Flow%20Vis%20Guide/particles-3-in-water/. Jean Hertzberg and Flow Vis course students, Particles 3: In Water
A dye version uses a small fixed injection port upstream in a transparent water channel, a dilute premix of dye with the channel water, illumination and a fixed optical camera. Start continuous injection at a recorded time and take a short exposure at : the visible filament approximates a streakline, not the accumulated pathline of one particle. Repeat with the same port and imaging geometry after changing the flow with time; compare the filament against local directions estimated from short displacements of sparse markers at . Agreement in a steady flow and possible disagreement when the flow changes are the predictions being tested; no measured curves are claimed here. The protocol follows Hertzberg's advice to use small ports, little injected volume and a dilute premix with matched density and viscosity. Check for nozzle disturbance by reducing injection rate, for buoyancy by watching the premix in still water, and for diffusion by comparing filament widths at different ages. Keep exposure short enough to suppress motion blur. Dye concentration approximates a passive scalar only when it has negligible feedback on the velocity field; finite port width, diffusion and out-of-plane motion limit how literally a visible filament can be read as a geometrical streakline. [ref]
https://www.flowvis.org/Flow%20Vis%20Guide/do-not-disturb-dyes-in-liquids/. Jean Hertzberg and Flow Vis course students, Dye Techniques 1: Do Not Disturb
Stress glut tensor 2026-10-20
A stress glut tensor describes a seismic source through an equivalent body-force density . For a symmetric stress glut tensor supported away from the boundary, integration by parts makes its coupling to a normal mode equal to , where is that mode's strain.