UNSW School of Physics documents a Doppler effect experiment using a buzzer based on piezoelectricity, powered by a taped-on battery, and a computer's built-in microphone. Audacity records the acoustic wave. First record the stationary source to establish its baseline frequency; then attach it to a bicycle passing the stationary microphone. The published spectrogram shows a rapid decrease in frequency during passage.[ref]
For numerical readout, select an approaching or receding interval, display its frequency spectrum using Plot Spectrum, and read the interpolated Peak frequency. The protocol recommends repeating with slightly different selections to test stability, and working outdoors to reduce reflections and standing waves. Longer windows refine frequency spacing while averaging over more motion. The baseline controls for the source's actual tone; repeated selections expose analysis-window sensitivity.[ref]
Under nearly collinear constant-speed approach, infer from the classical Doppler effect for sound. For recession the positive speed is . These inversions need a specified speed of sound. An offset path changes the projection, as in Doppler frequency along a trajectory; neither inversion measures the full speed near closest passage. The protocol's controls cannot remove arbitrary acceleration, background measurement noise or unresolved reflected paths. No new measurements are claimed here.
Acoustic phonetics 2026-11-05
Acoustic phonetics studies speech as a physical sound wave. A microphone records a signal related to changing sound pressure; analysis asks how its amplitude, timing and frequency content vary. A waveform displays variation over time, whereas a spectrogram displays the distribution of signal energy across both time and frequency.
For an original comparison, record a sustained vowel followed by a sustained hiss. Inspect each waveform at the same time scale and compare their spectrograms. Approximately repeated vocal cycles can give a harmonic structure, while the hiss provides an example of a noisier excitation. Broad spectral concentrations associated with the vocal tract are formants; they should be distinguished from the fundamental frequency of a repeating source. The spectrogram's analysis-window duration affects which temporal and spectral details are visible.[ref]
These are measurements of the signal, rather than direct readings of a listener's perceived pitch or a speaker's tongue position. Relating the signal to perception and production requires auditory phonetics and articulatory phonetics.
Acoustics Created 2026-10-05 Updated 2026-11-05
Acoustics studies sound: its generation, propagation, interaction with matter and detection. In a fluid, a small acoustic wave couples a pressure disturbance to the motion of the medium. The disturbance transports energy without requiring the same parcel of material to travel from the source to the receiver.
A loudspeaker and a microphone make a simple experiment. Changing their separation measures propagation delay, while changing the frequency in a bounded room reveals resonance and standing waves. A strong microphone response does not by itself imply a large net sound intensity: oppositely travelling waves can produce a large local pressure while their mean energy transport cancels. Acoustic impedance connects pressure and motion for a specified travelling wave.
The experiment in A time of flight method to measure the speed of sound using a stereo sound card by Carlos C. Carvalho and others makes wave speed visible as a delay. Two powered microphones feed separate channels of one stereo line input. A clap beyond one end of their common axis reaches the nearer microphone first. The displayed signals show two separated onsets when enlarged; count their sample separation to obtain and infer speed of sound from the measured microphone spacing . The reported sampling rate is . Repeating at different spacings gives a distance-versus-delay plot whose slope estimates speed of sound; dependence on distance helps identify acoustic travel rather than a fixed electronic delay. These are the paper's apparatus and observed readout, not measurements made for this article.[ref]
A controlled implementation also needs timing calibration for acoustic speed measurements. Put the microphones side by side to estimate the channel-delay offset , swap channels to check its sign, and check the acquisition clock against an independent timing reference. Measure spacings between consistent points on the microphones, keep the source outside their span and on their axis, and fit by linear regression rather than forcing a zero intercept. Repeat pulses and compare the same onset criterion before reflections arrive. These are proposed calibration and control checks, not additional procedures claimed for the paper.
One sample corresponds to for the reported sampling rate, so a delay of only a few samples has large relative measurement error. Background measurement noise, different microphone responses and threshold choice can move the apparent onset; reflections can supply a later competing pulse. Record temperature, keep air motion small, and compare several spacings. The result estimates speed of sound under those conditions; it cannot prove an exactly zero precursor below the instrument's sensitivity or establish finite propagation speed for every real medium. Both new diagrams in these sections show explicitly synthetic ideal wave equation solutions.[ref]
Acoustic transducer Created 2026-10-05 Updated 2026-11-05
An acoustic transducer converts between an acoustic disturbance and another form of signal or actuation. A microphone converts sound-induced motion into an electrical signal; a loudspeaker performs the opposite conversion. A piezoelectric transducer can use reciprocal coupling between deformation and an electric field to transmit and receive ultrasound.
Its frequency response, sensitivity and acoustic impedance affect what is emitted or measured. In a pulse-echo experiment, the same device can launch a short pulse and record the returning reflection. Travel time constrains distance only after the sound speed and the outgoing-plus-return path are accounted for.
Acoustic wave Created 2026-09-29 Updated 2026-11-05
An acoustic wave is a propagating disturbance in a material's pressure, mass density and particle motion. Compressing a small fluid region raises its pressure; the resulting pressure gradient accelerates adjacent material, while inertia carries the motion onward. This restoring mechanism permits longitudinal waves in an ordinary fluid.
For small perturbations about a uniform resting state, the linear continuity equation and momentum conservation combine into a wave equation. The squared speed of sound is the relevant derivative of pressure with respect to mass density; rapid locally reversible compression usually uses the isentropic derivative. A microphone records the pressure variation, while a travel-time measurement probes propagation speed. The particle velocity can remain much smaller than the speed of sound: local material oscillation and movement of the wave pattern are different quantities. Acoustic energy flux relates the pressure and particle-velocity fields to transported power.
An acoustic wavelength measurement makes an invisible spatial pattern readable with a ruler. The authored guide Interesting and inexpensive experiments for high school physics by Joe Wolfe places a loudspeaker near a pipe's open end, drives it with an oscillator, and slides a microphone attached to a metre rule through the pipe. An oscilloscope or computer displays the microphone signal. Its oscillation amplitude rises and falls with position; adjacent minima locate pressure nodes of a standing wave a distance apart. A cap gives a pressure antinode at the closed end; an open end has a pressure node just outside it. These are pressure patterns, distinct from displacement patterns. The guide advises wavelengths longer than the pipe diameter, sufficient pipe length to locate both a node and an antinode, and frequency spectrum analysis to distinguish the intended tone from other sounds.[ref]
The inference follows from superposition of two oppositely directed acoustic plane waves. In an ideal uniform, lossless pipe, taking equal pressure amplitudes and a rigid cap at gives
The time-varying pressure perturbation has local oscillation amplitude . Its zeros are separated by . Unequal incident and reflected amplitudes leave nonzero minima, but their spacing remains in this ideal model. A microphone detects that pressure variation through a changing electrical signal, rather than watching a wave crest move. Record the tone's frequency too, then infer phase speed .
For proposed controls, keep the drive frequency and amplitude fixed during a scan, verify the frequency on the recorded signal, and repeat the scan in both directions. Fit several minimum positions using linear regression to reduce dependence on one pair of positions. Check the ruler scale and use one consistent reference point on the microphone. Compare with the source switched off to locate background measurement noise; use frequency spectrum analysis to check for additional tones, and reduce drive if the trace ceases to resemble a sinusoid. Record air temperature and avoid strong air motion. These are suggested controls, not additional procedures or observations attributed to the guide.
The pipe must support approximately plane waves over the measured region: transverse structure at shorter wavelengths, the microphone's finite size, and disturbance by the ruler can compromise the interpretation. Weak reflection gives shallow minima, while damping and other reflections can shift the extrema of the simple two-wave model. Measure interior spacings rather than assuming the first minimum is exactly at the pipe lip. A short scan may not include enough minima to estimate reliably, and drift during sequential scanning can imitate spatial variation.
For an explicitly hypothetical calculation, and give , , and . No such measurements are claimed here. If independent small measurement errors in and fitted have standard deviations and , first-order error propagation gives . A systematic scale error or changing air conditions requires separate assessment.
Carlos C. Carvalho Created 2026-10-13 Updated 2026-11-05
A physics educator whose team built a simple time of flight measurement of the speed of sound. Two microphones at different distances record the same pulse through a stereo sound interface. Dividing the difference in path lengths by the arrival-time difference gives the propagation speed, while a common recording clock avoids having to synchronize two independent timers. The apparatus converts inexpensive audio hardware into a quantitative wave experiment.[ref]
Doppler effect Created 2026-10-05 Updated 2026-10-18
The Doppler effect is a change between emitted and received frequency caused by motion of the source or receiver. An approaching siren can send more wave crests per second to a microphone than the source emits per second; a receding siren sends fewer. The source need not change its own oscillation. The Doppler shift is , where is emitted frequency and is received frequency, both measured in hertz.
For acoustic waves, motion must be specified relative to the material carrying the wave. The speed of sound is measured in that material's rest reference frame. Moving the source changes the spacing of successive wavefronts; moving the receiver changes how quickly it crosses those wavefronts. These two mechanisms give different exact factors in the classical Doppler effect for sound, even for the same closing relative velocity.
This makes a microphone a motion probe: a stable tone supplies a repeating clock, and changes in arrival spacing reveal the source's motion toward or away from the receiver. An acoustic Doppler measurement can test the prediction directly. A passing source also illustrates why geometry matters: its speed can stay constant while the received frequency changes continuously, as in Doppler frequency along a trajectory.
The following sound model assumes linear acoustics in uniform stationary material with isotropy, constant speed of sound and negligible wave dispersion. Source and receiver speeds are below the speed of sound, and there is a single direct propagation path. Air motion requires transforming source and receiver velocities into the air's rest reference frame; a nonuniform flow requires a more general propagation model. At the sonic threshold the simple periodic-arrival picture fails; moving-point acoustic wavefronts and the Mach cone describe the relevant geometry, while finite shock waves require further physics. Light in vacuum instead requires the relativistic Doppler effect: the acoustic formula cannot be converted into its exact optical counterpart just by replacing the speed of sound with the speed of light.
Electret Created 2026-10-20 Updated 2026-11-05
An electret is a dielectric retaining long-lived electric polarization or trapped electric charge after its preparation field is removed. The retained charge distribution can supply a persistent electric field without continuous external polarization power.
An electret condenser microphone uses this property to bias a variable capacitor. Sound moves a diaphragm, changing capacitance and producing an electrical signal in the readout circuit. The electret supplies the polarization condition; it does not provide unlimited electrical energy, and the readout can still require power. Temperature, charge leakage and material history affect long-term stability. [ref]
Electroacoustics 2026-11-05
Electroacoustics studies conversion between electrical signals and sound, together with the measurement and control of that conversion. A microphone produces an electrical response to an acoustic input; a loudspeaker performs the reverse conversion. Their frequency responses, loading and directional behavior matter as much as a single sensitivity number.
For a receiving microphone, one can define the complex frequency response in volts per pascal, with the electrical termination and acoustic conditions specified. Equal outputs do not imply equal incident sound pressures if the two microphones have different sensitivities. Calibration supplies the link between the electrical recording and an acoustic measurement.
A motivating primary method is microphone reciprocity calibration. In the NIST system reported by Randall P. Wagner and collaborators, three laboratory microphones are measured in pairs using acoustic coupling cavities. One microphone transmits while another receives; known coupling properties and reciprocity relations allow the individual pressure sensitivities to be determined without starting from a separately calibrated reference microphone. Comparing results with different cavity lengths tests the acoustic corrections and associated measurement uncertainty.[ref]
An electroacoustic transducer converts between an electrical signal and acoustic motion. A loudspeaker or a pair of headphones converts electrical input into sound; a microphone converts acoustic input into an electrical output. The name describes the conversion role, not one universal physical mechanism.
In an idealized moving-coil device, a current-carrying conductor in a magnetic field experiences a force. If the active conductor length is and the relevant field strength is , the perpendicular-component model gives . With and current , the force is . A diaphragm and its mechanical load turn that force into motion and sound pressure; force alone does not determine the complete acoustic output.
Conversion therefore has several linked stages: electrical drive, mechanical motion and acoustic coupling. A pressure transfer function of the complete device can depend on frequency and its surroundings. Headphone measurements on an acoustic mannequin, for example, varied when the cushions were repositioned, despite using the same nominal transducer. This demonstrates a change in the coupled system rather than requiring a change in the electrical recording itself.[ref]
The distinction is useful in calibration. A quoted electrical sensitivity, mechanical displacement or acoustic pressure is meaningful only with its input, measurement point and loading conditions specified. An electroacoustic transducer transfers energy and information through a physical interface; its useful behavior belongs to the device together with that interface.
Kundt tube experiment 2026-10-18
PHYWE's implementation rubs a rod supported from each end. Its end disc drives a dusty glass tube; a movable tuning slide selects a clear pattern. A ruler measures repeated positions and a thermometer records gas temperature. The two supports select a rod wavelength equal to its length.[ref]
The University of Iowa also documents an electronic version: a loudspeaker drives the tube and a microphone on a plunger supplies an oscilloscope readout. This permits a spatial scan of sound pressure without relying on the dust pattern.[ref]
Figure 1.
Two ways to connect a time measurement to an acoustic spatial pattern
. Original functional schematic. Top: electronic drive, movable pressure probe and an independent position scale. Bottom: ideal free-end rod shapes with one centre support or two quarter-point supports. The upper blue curve denotes sound pressure; the lower curves show axial displacement along the rod, rather than bending. Apparatus proportions are schematic; the two rod modes are separate alternatives. Source. Details.
For a proposed pressure-scan measurement, keep the drive frequency fixed and move a small microphone through the tube. Record its position and fitted sinusoidal amplitude after each move; repeat the scan in reverse to reveal drift. Locate several consecutive maxima, rather than estimating a wavelength from a single pair. Reducing the drive checks whether the inferred spacing is independent of amplitude in the linear acoustics regime. A drive-off record estimates electrical background. These are controls for the proposed measurement, not reported observations from the cited demonstrations.
A microphone and its access opening can perturb the field. End compliance, losses and transverse modes also challenge the one-dimensional description. Dust traces identify a repeating structure, but the grains are not fluid parcels: the equations below describe sound pressure and acoustic particle velocity, rather than a detailed grain-transport model. The temperature and gas composition must remain sufficiently uniform to interpret a single fitted speed of sound.
Manuel B. Marques Created 2026-10-13 Updated 2026-11-05
A researcher whose joint acoustics experiment uses the two channels of a stereo sound interface as a shared time base. Delays between recordings of a pulse at two microphones determine the speed of sound. The method also shows why sampling rate, path-length measurements and reflected pulses matter: a plausible-looking delay is useful only if it corresponds to the intended propagation path.[ref]
M. D. Burkhard 2026-11-05
M. D. Burkhard coauthored, with R. M. Sachs, a 1975 paper describing an anthropometric manikin for acoustics research. Such instruments provide a reproducible physical stand-in for measurements affected by the shape of a listener's head and torso.[ref]
KEMAR provides the concrete apparatus example. Its documented configurations combine a head and torso with external-ear shapes, canal extensions and ear simulators for testing headphones and related equipment. The manufacturer describes these as approximations to human acoustic properties.[ref]
A microphone alone measures the sound pressure at its position; placing it in a representative physical arrangement changes the experiment to include the effects of that arrangement. Repeatability of a manikin measurement does not imply that its response equals the response of every individual listener. Modern configurations also should not automatically be attributed to the original 1975 instrument.
Microphone reciprocity calibration obtains absolute pressure sensitivities by measuring pairs of reciprocal microphones, rather than starting with a microphone of already known sensitivity. One microphone transmits into a known acoustic coupler while another receives. Reciprocity relates transmitting and receiving behavior, so the electrical transfer measurement constrains the product of their receiving sensitivities.
Schematically, after correcting each pair measurement for its coupling and electrical factors, write , and . Then , with analogous expressions for the others. The actual frequency-dependent calibration includes phase conventions, acoustic losses, diaphragm impedance and cavity geometry.
The NIST apparatus uses three laboratory-standard microphones in opposed ports of cylindrical air-filled couplers. The reported long and short coupler lengths are 9.4 mm and 4.7 mm; a sinusoidal source and electrical measurements determine pair transfer responses while temperature and static pressure are recorded. Comparing results from both couplers checks corrections that would be invisible in a single geometry.[ref]
Oscilloscope 2026-10-14
An oscilloscope displays an electrical signal versus time. In an acoustic wavelength measurement, the microphone trace supplies the tone's frequency and oscillation amplitude as the detector changes position.
Randall P. Wagner 2026-11-05
Randall P. Wagner is a physicist at the US National Institute of Standards and Technology whose research includes acoustic measurement. In 2011, Wagner and colleagues described improved microphone reciprocity calibration for laboratory-standard microphones.
The method measures pairs of microphones coupled through air-filled cavities, using reciprocity to determine pressure sensitivity. Comparing long and short coupling cavities tests corrections rather than assuming one apparatus geometry is exact. The reported service covered 31.5 hertz to 20 kilohertz and reduced stated measurement uncertainty relative to the previous service. This supports a traceable conversion from electric potential difference to sound pressure.[ref]
Samuel J. Sober 2026-11-05
Samuel J. Sober is a researcher in motor learning and the control of skilled movement. His laboratory combines recordings from neurons and muscles, behavioral experiments and computational analysis to investigate how the nervous system produces and adjusts movement. These approaches connect an animal's observable performance with candidate mechanisms for controlling it.[ref]
With Michael S. Brainard, Samuel J. Sober tested whether adult birds continually correct vocal errors. A microphone captured Bengalese finch song and processing equipment altered its pitch before playing it through headphones. Compensatory changes in the birds' pitch showed adjustment to a measurable error in auditory feedback. Unlike deafening alone, this manipulation supplied an error that a change in behavior could reduce.[ref]
Sound intensity Created 2026-10-13 Updated 2026-11-05
Sound intensity is the time-averaged acoustic energy flux, a vector measured in . In linear acoustics, , where is acoustic pressure and particle velocity. Its direction identifies net energy transport, and integrating its normal component over a surface gives the acoustic power crossing that surface.
A progressive plane acoustic wave satisfies , with mean mass density and sound speed . This formula uses the relation between pressure and velocity for that particular travelling field. Two opposite equal waves instead form a standing wave with zero net sound intensity, despite nonzero root mean square pressure. A microphone alone measures pressure; inferring transported power from it therefore requires assumptions about the field, especially near reflecting boundaries.