A series circuit comprising electrical resistance and inductance , placed in a parallel circuit with capacitance , has electrical admittance . Vanishing imaginary part at nonzero angular frequency gives the displayed condition, requiring . It defines zero voltage-current phase difference, which need not coincide exactly with the maximum of impedance magnitude when loss is present. At this frequency the electrical impedance is real and equals .
Keep the illumination and cell temperature approximately constant. Connect an ammeter and an adjustable resistor as a series circuit across the solar cell; connect a high-resistance voltmeter across its terminals. Vary the electrical resistance and record pairs of electric potential difference and delivered electric current . This measures the illuminated current-voltage characteristic.
A load close to a short circuit estimates at . With the load disconnected, an open circuit measurement using a high-resistance voltmeter estimates at . Neither endpoint delivers useful power: vanishes there. The intermediate readings locate the maximum of and determine the solar-cell fill factor. Holding illumination fixed matters because the photogenerated electric current changes with light intensity; holding temperature fixed matters because the diode saturation current and junction response change with it.
This experiment distinguishes producing an electric potential difference from delivering energy to a load. To determine conversion efficiency as well, measure the incident power on the illuminated area, rather than equating it to a lamp's electrical rating.
Figure 1.
The maximum-power point of an illuminated solar cell lies between short circuit and open circuit
. An illustrative ideal diode model, with , shows the current-voltage characteristic and delivered power. These are calculated curves, not measured data. Details.
A monolithic integrated circuit has its circuit elements fabricated in or on one semiconductor die. Their connections are essential: an unconnected collection of transistors does not implement the intended electrical circuit.
An original ideal example separates function from fabrication. Connect two resistors, above , in a series circuit across an ideal voltage source. With no load electric current drawn from their meeting point, Ohm's law and the Kirchhoff cycle law give
These equations apply to either a discrete circuit or an idealized monolithic integrated circuit realizing those same electrical resistances. Integration changes construction; the electrical circuit equations still determine the output. A real load, unwanted capacitance or finite resistor tolerance changes the ideal calculation. Manufacturing many functions together also couples their fate: a fatal defect can discard an entire semiconductor die, motivating the Poisson defect yield model.
For electric potential difference and electric current varying as sinusoids, choose the phasor convention
The electrical impedance is
Its modulus gives the voltage-to-current amplitude ratio, and its complex argument gives the voltage-minus-current phase difference. For ideal components,
These follow from Ohm's law , the capacitor law , and the inductor law . In phasor notation a time derivative becomes multiplication by , turning the linear ordinary differential equations of the electrical circuit into algebraic equations. Electrical impedances add in a series circuit; their reciprocals, the electrical admittances, add in a parallel circuit. This computes both amplitudes and phase differences in the steady response to sinusoids.
The original diagram has a series circuit containing and , in parallel with ; it is not three separate parallel components. The electrical admittance is therefore
For , voltage and current are in phase when the imaginary part of vanishes. Excluding the zero-frequency solution, division by gives
A nonzero lossy parallel coil resonance exists only if . With , and ,
For zero electrical resistance, the ideal parallel inductor-capacitor cancellation occurs at
The fractional reduction relative to the zero-resistance coil is
At exactly and , , so finite applied voltage draws zero net current in the ideal model. The quoted frequency is the limiting parallel-resonance value; the phase of an exactly zero current is undefined.
Series circuit 2026-10-18
A series circuit connects components along one unbranched path, so any electric current through the connected components is the same. Oriented terminal electric potential differences add along that path. In an open-circuit measurement, negligible electric current permits the electromotive forces of serially connected sources to add without appreciable internal electrical resistance drops.
Series RC impedance 2026-10-18
Consider a stipulated series circuit containing an ideal resistor of electrical resistance and an ideal capacitor of capacitance . The same electric current passes through both. Their terminal electric potential differences add by Kirchhoff's voltage law, so
A quick derivation uses : taking the derivative of the complex exponential multiplies the capacitor voltage phasor by , hence . Dimensionally, has units , matching .
At frequency , the angular frequency is . The signed capacitive electrical reactance, modulus and complex argument of the total electrical impedance are
Apply across the complete series circuit. Its root mean square electric current is
With voltage as the zero-phase reference, the current phasor has complex argument : electric current leads. The phasor drops have moduli and ; these add as complex numbers, not as positive magnitudes. Their squared magnitudes sum to .
Figure 1. . Original calculated ideal , model, not measured data or a filter transfer function. Left: the electrical impedance remains on and approaches the real axis as frequency increases. Right: its modulus and voltage-minus-current phase difference. The marked case matches the worked example; marks , , and . Details.
The mean absorbed power uses the root mean square values:
The ideal capacitor has zero cycle-averaged absorbed power; all the mean absorbed power becomes Joule heating in the resistor.[ref] To see why the phase factor appears, average over a full cycle with and . The cosine addition formula reduces the average to ; the term at averages to zero. Independently, , and the capacitor energy returns to its starting value after each cycle.
At fixed applied , the limit gives , and : the ideal capacitor blocks steady electric current. The limit gives , and . These are limits of the ideal lumped electrical circuit; unwanted lead inductance and component losses can invalidate that model at high frequency. At , the equal legs of the impedance right triangle give and without numerical evaluation. Measuring both the magnitude and the sign of the phase difference distinguishes this capacitor response from an equally large positive electrical reactance.
Thermoelectric cooling 2026-10-18
Thermoelectric cooling uses the Peltier effect to remove heat from a load using electrical work. A typical thermoelectric module connects many pairs of different semiconductors electrically in a series circuit and thermally in parallel between two faces. For an idealized pair with , positive conventional current crosses n to p at the cold bridge and p to n at the hot return. With common bridge material and isothermal contacts, the intervening metal contributions telescope: the net pair coefficient is . For identical pairs define the module Seebeck coefficient .
Choose fixed face temperatures , , module electrical resistance and open-circuit thermal conductance . All three module parameters are constants over the chosen operating range. Positive is the orientation absorbing Peltier effect heat at c. Define as net heat extracted from the cold reservoir per unit time, as net heat delivered to the hot reservoir per unit time, and as electrical power entering the module. Despite the conventional letters , both denote power in watts, not accumulated energy. Ferrotec gives the corresponding single-stage equations and distinguishes module performance from bypass leaks.[ref]
Thermopile Created 2026-10-14 Updated 2026-10-18
A thermopile connects multiple thermocouples in series to turn a temperature difference into a larger electrical signal. Absorbed thermal radiation can heat its sensing junctions while reference junctions remain cooler; the signal depends on the thermal and optical design.
A thermopile is an array of thermocouples connected as a series circuit with their electromotive forces adding in the chosen terminal order. It measures a collective temperature difference through the Seebeck effect. An open-circuit electric potential difference requires no externally supplied electric current through the array: a high-input-electrical resistance voltmeter reads the signal. The heat that maintains the junction temperature difference still comes from somewhere, such as absorbed electromagnetic radiation.
In a membrane detector, an absorbing film heats the measuring junctions while reference junctions lie on the surrounding support. Actual junction temperatures can differ across the membrane.[ref] This converts difficult-to-observe heat transfer into an accessible electrical signal; the series connection combines many small contributions without requiring every thermocouple to have a separate meter.