Three physically distinct contributions are unseen dark matter, hot diffuse intracluster gas omitted from the summed stellar mass, and faint stars or stellar remnants missed by transferring the Milky Way mass-to-light ratio to the cluster. The first two are actual additional components; the third changes the inferred stellar budget. Departures from virial equilibrium, velocity anisotropy or extra nonthermal pressure can also bias the dynamical or X-ray estimates, although they need not remove the discrepancy.
A CT number is a dimensionless relative attenuation measure, conventionally . The X-ray spectrum used in computed tomography has an effective energy far below and is polychromatic. Its photoelectric absorption contribution depends strongly on composition, whereas water and soft-tissue attenuation at the positron emission tomography energy is mainly Compton scattering. Thus a CT number is neither a linear attenuation coefficient nor an energy-independent mass attenuation coefficient.
The usual conversion calibrates a piecewise linear or bilinear relation between CT numbers and . The air–water branch models predominantly density differences in lung and soft tissue; a separate water–bone branch accounts for the different energy dependence of mineralized tissue. The calibration depends on the computed tomography spectrum. After geometric registration, the resulting linear attenuation coefficient map is forward projected along each coincidence line of response to obtain . If a mass coefficient is stored, its conversion to a linear coefficient must also include mass density. Unusual high-atomic-number materials can violate the simple tissue calibration, so the conversion is a physical material model, not a universal arithmetic rescaling.[ref][ref]
For a megavoltage X-ray beam, the surface absorbed dose is below the subsurface maximum. Photons generate energetic secondary electrons, mainly through Compton scattering; the downstream electron fluence initially builds up until approximate charged-particle equilibrium is established. Beyond this buildup region, decreasing primary photon fluence, scattering and geometric spreading make the depth-dose curve fall gradually. A penetrating photon beam has a substantial exit dose.
A nearly monoenergetic proton beam deposits a moderate entrance dose, then a sharp Bragg peak near the end of its range. As nonrelativistic protons slow, their electronic stopping power rises approximately as over the relevant part of the track. Once the protons stop, the dose falls steeply. Range straggling and energy spread broaden the peak; nuclear interactions add a smaller nonideal tail, so an exact hard cutoff is an idealization. Superposing appropriate incident energies produces a spread-out Bragg peak covering an extended target.[ref]
The label MV for an X-ray treatment beam specifies the nominal accelerating potential of the electron accelerator. Its bremsstrahlung beam is a broad photon energy spectrum with an endpoint of order , not a monoenergetic beam whose individual photons all carry the quoted numerical energy. Proton therapy beam energies can instead be specified directly in MeV per incident proton.
Figure 1.
Qualitative photon and proton depth-dose profiles and functions of passive proton beam modifiers
. Details.
Photographic plate 2026-10-18
A plate bearing a photosensitive coating that records an exposure, including exposure to X-rays.
Radiation Created 2026-10-20 Updated 2026-11-05
Radiation transports energy away from a source through propagating fields or emitted particles. Electromagnetic radiation includes radio waves, visible light, X-rays and gamma rays; alpha particles, beta particles and neutrons provide particle-radiation examples. The word alone does not specify an energy, a hazard, or a detection method.
An experiment must distinguish the incident field from its interaction with the detector. A photodetector measures a light-induced response, while an ionization chamber collects charge created in a gas. Neither instrument responds equally to every kind of radiation. Ionizing radiation is classified by its ability to remove bound electrons under the relevant interaction conditions, rather than simply by whether the source is radioactive.
Radiography Created 2026-10-18 Updated 2026-11-05
Radiography forms an image from spatially resolved transmission of X-rays or other penetrating radiation. A source illuminates the object, and a detector on the other side records how much radiation reaches each position. Variations in attenuation make internal differences observable without cutting the object.
A thicker region and a more strongly absorbing material can give similar transmission, so one projection does not uniquely determine composition or three-dimensional shape. Unwanted scattering reduces image contrast by adding radiation that did not follow the intended straight path. A reference exposure measures source and detector nonuniformity; multiple viewing directions provide additional geometric information.
Radiologic technologist 2026-11-05
A radiologic technologist is a healthcare professional who carries out medical imaging procedures and helps obtain images suitable for interpretation. Responsibilities include positioning the patient, operating imaging equipment, checking image quality and recording acquisition details. Depending on specialization, the equipment can use X-rays, computed tomography, magnetic resonance imaging or ultrasound. The professional role connects the physical measurement to a usable clinical image.[ref]
Consider a radiography examination intended to show an anatomical boundary. A technically sharp image can still be inadequate if positioning superimposes the structure on another one or excludes it from the recorded field. The radiologic technologist therefore needs both knowledge of anatomy and control of the acquisition geometry. In an X-ray examination, restricting the beam to the required region also helps limit unnecessary exposure and scattered radiation.[ref]
Acquiring an image and deciding what its findings mean are related responsibilities within a team. The radiologist interprets the study in its clinical context; a radiologic technologist helps ensure that the acquired evidence can answer the intended question. For example, motion blur can conceal a small feature without establishing that the feature is absent. Recognizing an acquisition limitation prevents a technical defect from being mistaken for biological evidence. Specific professional titles and permitted duties depend on training and jurisdiction.
Riccardo Giacconi Created 2026-10-18 Updated 2026-11-05
Riccardo Giacconi pioneered X-ray astronomy using instruments carried above Earth's absorbing atmosphere. His team's 1962 rocket flight found a strong source outside the Solar system, later known as Scorpius X-1, together with a diffuse X-ray background.[ref]
His Nobel lecture traces the subsequent transition from brief rocket measurements to more sensitive surveys and imaging instruments. Increasing collecting area, observing duration and angular resolving power changed the questions that could be asked: sources could be located, separated and studied as physical systems.[ref]
R. Nowotny Created 2026-10-18 Updated 2026-11-05
A scientific author credited with the chapter underlying the IAEA teaching slides on X-ray production. The treatment links electron acceleration, target interactions and tube design with the emitted X-ray spectrum. This connects the physical origin of radiation with the practical variables used to control a laboratory or diagnostic source.[ref]
Wilhelm Conrad Röntgen's 1895 first communication describes an induction coil driving an evacuated gas-discharge tube, enclosed in black cardboard in darkness. A paper screen coated with barium platinocyanide showed fluorescence even with its uncoated side facing the tube, visible two metres away. The covering excluded ordinary illumination.[ref]
He interposed materials: a thousand-page book transmitted; lead was practically opaque. A stepped stack of foil produced a photographic plate record. Different materials were not equivalent at equal density and thickness. Photographic plates checked visual observations while remaining covered against ordinary illumination.[ref]
Section 14 lists photographs of hand bones, wire on a bobbin, boxed weights, an enclosed compass, and a lead-painted door. It does not identify the hand's owner. Magnetic deflection moved the cathode ray impact point and thus the source, without bending the emerging X-rays. Their nature remained unsettled.[ref]
The observations belong to 1895; the contemporary English translation appeared in Nature on 23 January 1896.[ref] The experimental logic separates production, transmission and detection. A visibly opaque covering can transmit X-rays; fluorescence then converts deposited energy into visible light. A shadow measures a difference between paths through an object, rather than a direct view of its surface. Neither a screen's brightness nor photographic darkness alone measures an absolute X-ray energy or establishes the X-ray attenuation law below.
R. Robin Created 2026-10-18 Updated 2026-11-05
A scientific contributor to IUPAC recommendations for labeling X-ray emission lines and absorption edges. Connecting a spectral label with an energy-level designation makes the notation applicable to different transitions, improving the comparability of spectroscopic descriptions.[ref]
Rudy Wijnands Created 2026-10-20 Updated 2026-11-05
Rudy Wijnands and Michiel van der Klis reported persistent millisecond X-ray pulsations in an accreting neutron star system using a fast timing instrument.[ref]
A stable pulse train supplies evidence of rapid rotation that differs from a broad quasi-periodic feature. The observation connects accretion-powered systems with the spin-up interpretation of a recycled pulsar, while the origin of an individual timing feature still requires a physical model.
Scorpius X-1 2026-10-18
Scorpius X-1 is the celestial X-ray source associated with the 1962 discovery, subsequently located more precisely. The discovery scan did not supply a resolved image of this X-ray binary.[ref]
S. Edyvean Created 2026-10-18 Updated 2026-11-05
A scientific teaching contributor credited with the initial work used for an IAEA slide set on X-ray production. The shared material explains how tube operating conditions and filtration change the radiation output, helping distinguish the amount of radiation from the distribution of photon energies.[ref]
Kai Siegbahn's early instrument used iron-free magnetic double focusing and a thin-window Geiger-Müller counter. His later instrument, compatible with ultra-high vacuum, used a spherical electrostatic electron energy analyzer and monochromatic aluminum X-rays. Argon mixed with methane supplied simultaneous reference lines.[ref]
Two sulfur lines in sodium thiosulfate distinguished chemical environments within one compound. A separate gold comparison showed a fingerprint obscuring substrate lines.[ref]
For an unknown sample, first document its preparation and transfer, then compare survey and detailed scans under reproducible illumination, contact and acquisition conditions. Repeat a region to test change during exposure. If a cleaning treatment is used, compare before and after rather than assuming that cleaning preserves the original chemical bonds. Report the photoelectron binding energy reference, reference lines, charge-compensation conditions and instrumental settings with the inferred chemical shift in photoelectron spectroscopy. A chemical interpretation should survive these checks as well as explain the line separation.
Stephen M. Seltzer Created 2026-10-18 Updated 2026-11-05
A radiation physicist who coauthored NIST reference tables for X-ray and gamma ray interactions with John H. Hubbell. The mass energy-absorption data use his calculations to account for how much photon energy is retained after interaction processes. This supports radiation-energy deposition calculations alongside the separate mass attenuation coefficient used for beam transmission.[ref]
Supernova remnant Created 2026-09-25 Updated 2026-11-05
A supernova remnant is the expanding stellar debris and shocked surrounding gas left by a supernova. The debris drives an outward shock wave into the ambient interstellar medium; a reverse shock wave heats the ejecta as the expansion is decelerated. Hot plasma emits X-rays, while accelerated electrons produce synchrotron radiation in the magnetic field. Comparing successive images measures expansion, and X-ray spectroscopy maps the expelled chemical elements. In Cassiopeia A, the Chandra X-ray Observatory resolves the outer shock and heated debris. Such observations connect an explosion's kinetic energy and newly produced elements to the subsequent heating and enrichment of the interstellar medium.[ref]
Figure 1. . Observed on 19 August 1999. Display colors represent detected intensity. Credit: NASA/CXC/SAO. Source.
Thermal radiation processes by Jelle S. Kaastra and others Created 2026-10-20 Updated 2026-11-05
Space Science Reviews 134, pp. 155–190. The article discusses plasma emission, absorption, ionization and practical X-ray diagnostics. Its institutional NED version includes a cooling-function section with explicit density normalization.
Thomson electron transmission diffraction experiment Created 2026-10-18 Updated 2026-10-20
Alongside the 1927 Davisson–Germer experiment, George Paget Thomson developed an independent transmission test. Alexander Reid first used celluloid; Thomson used thin metal films. A narrow electron beam crossed a film about thick, reaching a photographic plate perpendicular to the beam. Rings appeared. Accelerating voltages of – set the de Broglie wavelengths; metal structures known from X-ray diffraction allowed quantitative comparison. A downstream magnetic field deflected ring-forming electrons like those passing through holes, identifying the carriers as electrons rather than X-rays. Celluloid's uncertain structure limited its quantitative interpretation.[ref]
The Davisson–Germer experiment uses crystal reflection and angular electric current scans; this transmission camera records a spatial pattern behind the specimen. Both probe interference in electron diffraction, with different specimen preparations and readouts. A developed photographic plate records accumulated detections, not a direct image of the wavefunction.
Why rings? In an ideal film containing many small crystals with uniformly distributed orientations, a family of lattice planes with spacing can satisfy Bragg's law at every azimuth about the incident beam. First-order elastic scattering then forms a cone of opening half-angle , where . A flat detector a distance downstream cuts this cone in a circle:
The last expression requires small scattering angles. It explains a useful control: hold the specimen and camera distance fixed, increase accelerating voltage, and the ring radii should shrink with the electron accelerating-voltage wavelength. It predicts positions, not intensities: preferred crystal orientations, film thickness and repeated quantum scattering can alter a real pattern.
For a chosen example, take and . The exact relativistic electron accelerating-voltage wavelength gives at and at . The corresponding exact ring radii are and . These are calculated examples with chosen spacings and camera distance, not Thomson's measurements. The higher voltage lies outside the range quoted from his lecture, deliberately illustrating a prediction rather than reconstructing his data.
Figure 1.
Calculated electron diffraction rings shrink as accelerating voltage increases
. Original transmission geometry and calculated first-order ring positions for chosen plane spacings and at camera distance . Both detector views have identical scales. Exact relativistic de Broglie wavelengths and determine the radii; ring brightness and width are drawing choices. The geometry sketch exaggerates the scattering angles. No experimental data or borrowed diffraction photograph is plotted. Source. Details.
Trevor Ponman 2026-11-05
Trevor Ponman is an astrophysicist who studies hot gas in galaxies, galaxy groups and galaxy clusters. Such gas records both gravitational confinement and the energy supplied by stellar activity.[ref]
With Dave Strickland and Ian Stevens, he analysed diffuse X-ray emission from the M82 galactic wind. Separating point sources from extended emission allowed the team to infer properties of the outflowing gas and test physical explanations for its radiation.[ref]