Radiant flux Created 2026-10-14 Updated 2026-10-18
Radiant flux is the power carried by electromagnetic radiation: radiation energy transferred per unit time, measured in watts, . Specify what is counted: all radiation emitted by a source, radiation within one beam, or radiation intercepted by a photodetector. Writing for the cumulative energy crossing the specified boundary gives
The first expression is an instantaneous derivative; the second is an average over the stated time interval. If arrives during , the mean radiant flux is . The photodetector's absorbed power equals this incident radiant flux only if it absorbs all of the incident radiation.
Keeping radiant flux fixed while widening a beam reduces its irradiance, the incident power per receiving area. Radiance additionally resolves the propagation direction and has units ; an optical camera can collect different radiant fluxes from sources with the same radiance but different apparent solid angles. Luminous flux, measured in lumens, weights the optical spectrum by the human eye's standardized response instead of counting energy equally at every wavelength. Equal radiant fluxes need not give equal luminous fluxes.[ref]
Radiant power also differs from the optical power of an optical lens, which is reciprocal focal length in dioptres. Likewise, astronomical radiative flux is power per area. Stating the units prevents these shared words from hiding different physical quantities.
Sagnac interferometer 2026-10-18
A Sagnac interferometer uses a beam splitter to send light with optical coherence around a common closed optical path in opposite directions, then recombines the beams to read their phase difference. Mirrors or a guiding path define the loop; the source, beam splitter, loop and readout rotate together in the basic experiment. A small relative beam tilt makes spatial interference fringes whose displacement reveals a change of phase difference. At one fixed output, a photodetector can instead record the corresponding change in light intensity.
Figure 1.
Counterpropagating light around a rotating closed loop, with a shared beam splitter and readout
. Original rectangular teaching layout. The vector area points out of the page for the positive counterclockwise path. The source and readout rotate with the mirrors. Arrow offsets separate the two directions visually; they do not represent different physical paths. The drawing is not a reconstruction of the historical mirror arrangement. Details.
Arthur Leonard Schawlow's 1981 lecture describes an external-cell arrangement: a beam splitter makes opposed beams, an optical chopper interrupts the pump, and a lock-in amplifier reads the probe detector with the chopper reference. Pump-on reduces absorption and raises the detector signal; scanning the laser finds the narrow resonance. Its first application used iodine; pressure and laser jitter limited the resolution.[ref]
Figure 1.
Counterpropagating pump and probe with synchronous transmission readout
. Original functional drawing of the cited external-cell principle. Beam separation is exaggerated; this is not a reconstruction of the pulsed sodium apparatus. Details.
For an original detector model, let be the probe power reaching a photodetector without sample attenuation and let be the sample's probe optical depths. After subtracting a stable detector background, the transmitted powers are
A positive synchronous change means less probe photon absorption, provided incident probe power is stable and scattered pump light is excluded. For small optical-depth changes the fractional signal is approximately . A lock-in amplifier's voltage also depends on gain, reference phase and chopping waveform; it is not automatically this dimensionless ratio.
Useful controls are blocking the pump, detuning far from the feature, reversing or adjusting beam alignment, and repeating the scan at several pump light intensities. Frequency calibration, sample pressure, transit through the beams and laser frequency fluctuations must be assessed separately. Nearly opposed beams leave a residual Doppler shift: for wave vectors , the simultaneous-resonance condition gives . Exact opposition removes this transverse sensitivity in the first-order model.
Single-photon detector 2026-10-25
A photodetector capable of registering an individual absorbed photon as a distinguishable event. The detection record may include a click time and an output-channel label. Such a detector need not resolve the number of photons in a pulse: an ordinary single-pixel single-photon avalanche diode produces essentially the same saturated avalanche pulse when one or several photons trigger the same detection interval. Detector efficiency, dark counts and detector dead time affect the observed photon counting statistics.
A motivating measurement used the McMath solar optical telescope at Kitt Peak. The Sun's image drifted across a -high, -wide optical slit; a double-pass spectrograph selected wavelength intervals from wide at to at . An EMI 9750 QB photodetector or silicon photodiode supplied a digitized signal: samples were summed into 4096 positions per crossing, including dark and off-limb sky readings. [ref]
Controls included daily realignment of optical telescope mirrors, wavelength settings between spectral lines insensitive to the rotational Doppler shift, selection of detectors without detectable hysteresis, and measured electronic nonlinearity corrections below of maximum signal. Limb-position calibration combined centres of gravity of the edge derivative profiles with almanac semidiameters; the preliminary edge shifts were consistent with astronomical seeing of approximately arcseconds full width at half maximum. [ref]
The decreasing centre-to-limb readout gives a specific intensity profile, constraining stratification of the photosphere under a radiative transfer model. Astronomical seeing, instrumental scattering of light, and solar granulation limit this inference; brightness alone does not uniquely determine temperature versus geometric height. These observations need not follow the stipulated linear limb-darkening law.
Spatial resolution element Created 2026-10-06 Updated 2026-10-14
A spatial resolution element is one independently resolved angular or spatial scale under a specified resolution criterion. For an ideal telescope of diameter , its angular scale is of order and its angular area of order . A photodetector detector pixel or spaxel can be smaller than a resolution element without adding independent spatial information.
Spectral resolution element Created 2026-10-06 Updated 2026-10-14
A spectral resolution element is a spectral interval at the adopted instrumental resolution. At spectral resolving power , its width is . The number of photodetector detector pixels sampling it is distinct from .
Spectral responsivity Created 2026-10-14 Updated 2026-10-18
For a photodiode in its linear regime, spectral responsivity is the dark-subtracted electric current per incident radiant flux in a narrow band at wavelength , measured in . More generally a photodetector's readout can be electrical voltage or another quantity, with corresponding units. A broad-band readout weights the incoming optical spectrum by the detector's spectral responsivity; it is not the unweighted total incident power. [ref].
Stellar intensity interferometry measures a star's angular diameter by comparing fluctuations of detected light intensity at separated collectors. Each collector has its own photodetector; an analog multiplier or a digital correlator compares the electrical outputs. Changing the interferometric baseline changes the sampled spatial optical coherence. An unresolved star produces correlated fluctuations; a resolved extended source supplies different mixtures of emission directions, reducing their correlation.
This makes a useful telescope out of a surprising observable: the fluctuations discarded by an ordinary average-brightness measurement. Optical beams need not travel to a common combiner. A relative wave phase perturbation leaves unchanged, so pure phase errors do not directly change the local light intensity. Electronic delay alignment remains necessary; intensity changes from atmospheric scintillation, collection losses, and instrumental noise still require controls.
Let join the collectors and let be the unit line of sight toward the star. The relevant interferometric baseline is its projection onto the plane of the sky:
The reference arrival-time difference has magnitude , with speed of light . Correct that delay, with a sign fixed by channel order, before averaging the residual correlation at . The physical collector separation equals only when it is perpendicular to ; tracking a star can change the projection even for fixed collectors.
Figure 1.
Functional geometry of stellar intensity interferometry: separate optical detection followed by electrical correlation
. Original schematic with the reference direction normal to the baseline. Matched optical selection feeds independent detectors; mean removal, response and delay alignment precede multiplication and averaging. This is not a scale drawing of the historical apparatus. Details.
Stray light 2026-10-18
Stray light reaches a photodetector by an unintended path or from outside the intended wavelength band. It can bias spectrophotometry by adding received radiant power.
Total internal reflection Created 2026-09-29 Updated 2026-10-18
Total internal reflection occurs when a wave travels from higher to lower refractive index above the critical angle for total internal reflection, leaving no propagating transmitted plane electromagnetic wave normal to the interface.
At an infinite planar interface, total internal reflection returns all incident normal power in the reflected plane electromagnetic wave. Assume homogeneous dielectrics with isotropy, linearity, no dielectric loss, magnetic permeability , and positive real refractive indices . Above the critical angle for total internal reflection, both TE polarization and TM polarization have unit optical reflectance despite the external evanescent wave.[ref]
This makes total internal reflection useful for guiding light in an optical fiber: suitable internal incidence angles keep energy inside successive boundaries. Its more surprising feature is that perfect optical reflectance coexists with an external electric field. The evanescent field in total internal reflection can interact with a nearby object, as the frustrated total internal reflection experiment demonstrates.
For an original idealized example, choose , at vacuum wavelength . At angle of incidence , Snell law for electromagnetic waves gives an angle of refraction , so a transmitted light ray still emerges. At , its direction becomes tangent to the boundary. At , the proposed sine of a real angle of refraction would be : the transmitted wavevector must instead have an imaginary normal component. These are predictions for the stipulated media, not measured properties of a particular block.
Figure 1.
Constructed ray geometry just below, at, and above the critical angle for refractive indices 1.5 and 1; arrows indicate directions rather than relative powers
. Details.
A real semicircular-block experiment isolates this threshold. The University of Maryland laboratory instructions place a laser, motor-driven rotation stage and photodetector together; an aperture limits the detector voltage. The semicircular block is centered on the rotation axis, with the photodetector aligned along its flat face. The instructions identify a strong grazing-beam signal and a weaker signal just before the critical angle for total internal reflection. The readout is detector voltage versus stage angle. Retracing the incident laser beam identifies normal incidence for alignment.[ref]
The semicircular shape supplies a geometric control: a light ray passing radially through the curved face enters at normal incidence, avoiding additional entrance refraction. The weaker signal near the flat face locates a limiting angle of refraction; a vanishing remote-detector signal alone would not establish that the external electric field vanishes. Beam width and alignment limit angular resolution; no measured threshold or decay depth is supplied.[ref]
Vacuum photodiode Created 2026-10-18 Updated 2026-10-20
A photodetector in which light releases electrons from a cathode into a vacuum, and an anode collects them. A positive collecting-anode bias relative to the emitting cathode drives collection across the vacuum gap.