Topics (384k) Articles (398k) Users (410) Discussions (242) Comments (383) Files (13k) New article
A finite group of Lie type is built from an algebraic group in positive characteristic by taking fixed points of a suitable Frobenius-type endomorphism, often followed by a derived-group or central-quotient construction. The terminology covers classical matrix families and exceptional families, including twisted forms. It connects the structure of Lie theory with finite group theory; such a finite group is not a positive-dimensional real Lie group.[ref]
For example, consists of determinant-one matrices over a finite field. There are choices for its first column; for each nonzero first column, the determinant-one equation has solutions for the second. Dividing by its scalar center gives the projective special linear groupFor , its order is sixty. These projective groups are simple for , whereas and are exceptions.[ref]
Simplicity of PSLn(F) by Keith Conrad. Introduction and section 3
The classification of finite simple groups uses the simple members of the Lie-type families, with exceptional small parameters treated explicitly. A family name alone does not guarantee simplicity.
A volatility matrix is the matrix of diffusion coefficients coupling asset returns to Brownian noise. For positive asset prices driven by independent standard Brownian motions, writeThe -by- matrix determines the instantaneous return covariance matrix : the Brownian increments satisfy . The same covariance rate applies to log returns, while their drift includes the Itô correction.
For , the covariance-rate matrix is . The two rows share the first noise source, producing a nonzero cross-covariance.
The volatility matrix is not uniquely determined by covariance alone: replacing by for an orthogonal -by- matrix leaves unchanged. The noise-coordinate representation and the observable covariance are therefore different objects.
Oxygen-uptake assumptions in estimated Fick output arise when a Fick principle calculation substitutes predicted oxygen consumption for a direct measurement. With an arteriovenous oxygen content difference ,The measured blood samples and the predicted numerator are different sources of information. Precise arterial oxygen content and mixed venous oxygen content measurements cannot by themselves validate the assumed oxygen consumption.
A primary comparison explicitly examined estimated-oxygen-uptake Fick principle output against thermodilution. Its clinical observations therefore compare particular measurement procedures, not a conservation identity against an unrelated physical law.[ref]
An original exact error decomposition isSuppose actual oxygen consumption is mL/min and mL/dL. Actual cardiac output is then dL/min, or L/min. Assuming mL/min with the correct content difference produces L/min. If the measured content difference were also underestimated to mL/dL, the two errors would cancel numerically and again produce L/min. Agreement of the final answer would not prove either input accurate.
The numerator must also represent the state during sampling. A prediction for one physiological condition need not describe oxygen consumption after a change in activity or metabolism. The steady-state balance assumes compatible sampling and no continuing oxygen accumulation within the represented system. Near a small content difference, even a modest absolute error in can strongly change the inferred blood flow. Reporting estimated uptake as an assumed input keeps these model and sampling limitations visible.
Fibrinopeptide A is the 16-amino acid peptide released from the N-terminus of each A-alpha chain of human fibrinogen by thrombin. Removing Fibrinopeptide A exposes the A knob on the remaining molecule, enabling a fibrin knob-hole interaction. The released fragment and the exposed binding site are different objects.[ref]
Fibrinopeptides A and B release in the process of surface fibrin formation by Tomas Riedel and others. Introduction: chain origin, peptide lengths and exposure of polymerization sites
Release of Fibrinopeptide A provides a measurable record of a particular peptide bond cleavage. A kinetic study measured Fibrinopeptide A and Fibrinopeptide B separately: under its solution conditions, at least 97% of Fibrinopeptide B release followed Fibrinopeptide A release. The study also found that a change at the cleavage-site arginine strongly reduced catalytic efficiency, linking amino acid identity to reaction rate.[ref]
Steady state kinetic parameters for the thrombin-catalyzed conversion of human fibrinogen to fibrin by D. L. Higgins and others. Abstract: sequential release and the Arg16-to-His variant
Fibrinopeptide B is the 14-amino acid peptide that thrombin releases from the N-terminus of each B-beta chain of human fibrinogen. Cleavage exposes the B knob on the remaining fibrin molecule, allowing a fibrin knob-hole interaction. Each fibrinogen molecule contains two B-beta chains and can therefore release two copies of Fibrinopeptide B.[ref]
Fibrinopeptides A and B release in the process of surface fibrin formation by Tomas Riedel and others. Introduction: twofold chain composition, 14-residue peptide and B-knob exposure
Its release need not track Fibrinopeptide A release identically. A study comparing dissolved and surface-adsorbed fibrinogen incubated the preparations with thrombin and measured the released peptides by high-performance liquid chromatography. Surface-bound preparations released Fibrinopeptide B without the characteristic solution-phase lag; densely adsorbed preparations could release more Fibrinopeptide B than Fibrinopeptide A.[ref]
Fibrinopeptides A and B release in the process of surface fibrin formation by Tomas Riedel and others. Methods: polystyrene wells and HPLC; Abstract and Figures4–5: altered lag and release proportions
The experiment shows why a measured fibrinopeptide ratio needs its reaction conditions. Molecular presentation at a surface changes access to cleavage sites, so a typical sequence observed in solution should not be turned into an unconditional rule for every preparation.
Common-gain cancellation and flow-offset bias in expiratory ratios distinguishes an error that rescales both volumes equally from one that accumulates differently over time. Let true FEV1 be , true FVC be , and their ratio be . A shared positive volume gain cancels exactly: . The result requires the same gain for both quantities, not merely the same instrument name.
A constant error in measured volumetric flow rate has another effect. If the first-second interval lasts and the full recording lasts , integration givesThe ratio alone identifies neither nor separately; only their relative combination enters this model. Nor does the positive duration-dependent error necessarily raise the ratio.
The exact difference isFor small , its sensitivity coefficient at zero offset is . If average early volumetric flow rate exceeds average whole-record volumetric flow rate , a positive volumetric flow rate offset lowers the ratio. If the averages agree, that offset leaves the ratio unchanged in this model.
An original example uses L, L, s and s. The true ratio is 0.60. At , the zero-offset sensitivity is . An offset gives a first-order shift of ; the exact ratio is . A common 5% gain error without the offset would leave 0.60 unchanged.
Independent numerator and denominator gains would instead multiply by . Clipping, early termination and different timing conventions are additional measurement effects, so gain cancellation is not a general guarantee of ratio accuracy. The GUM requires the full measurement model and shared-input effects to be retained.[ref]
Guide to the expression of uncertainty in measurement by JCGM. §§5.1–5.2, measurement sensitivity and correlated inputs
The spirometry statement separately checks the acceptability of the constituent volumes.[ref]Standardization of Spirometry 2019 Update by Brian L. Graham and others. Table 7, FEV1 and FVC criteria
Arachidonic acid is a twenty-carbon polyunsaturated fatty acid with four cis carbon–carbon double bonds, at positions 5, 8, 11 and 14 when counted from the carboxyl group. Its molecular formula is . The shorthand records twenty carbons, four double bonds and the first double bond six carbons from the methyl end.[ref]
PubChem Compound database by National Center for Biotechnology Information. Arachidonic acid, CID 444899, formula and (5Z,8Z,11Z,14Z) stereochemistry
The indexing conventions describe the same structure from opposite ends: the bond between carbons 14 and 15 from the acid end is the first encountered from the methyl end. The cis geometry also distinguishes this molecule from stereoisomers with the same formula. Composition, double-bond positions and geometry all belong to its chemical identity.
A polyunsaturated fatty acid is a fatty acid with at least two carbon–carbon double bonds in its hydrocarbon chain. The carbon–oxygen double bond in the carboxyl group does not contribute to this count. Many biological examples have cis double bonds, whose geometry changes how chains pack.[ref]
For example, arachidonic acid has twenty carbons and four carbon–carbon double bonds, while docosahexaenoic acid has twenty-two carbons and six. Chain length, bond positions and cis/trans geometry convey different information. A count such as “four double bonds” alone cannot uniquely identify the molecule or all of its physical properties.[ref]
PubChem Compound database by National Center for Biotechnology Information. Arachidonic acid, CID 444899; docosahexaenoic acid, CID 445580, structural records
An extracted-ion window capture fraction is the fraction of a particular ion peak's integrated mass-coordinate signal retained by an extracted ion mass window. For a nonnegative signal-density model and window ,assuming the denominator is finite and positive. This is a fraction of the specified peak model, not necessarily a fraction of analyte molecules or of the entire total ion current. The extraction window selects which mass-coordinate signal enters a profile.[ref]
Extracted ion profile in IUPAC Gold Book. Entry 12410, selected mass-coordinate values and time-dependent profile.
An original Gaussian function model makes window-capture sensitivity to mass offset explicit. Let the peak center be displaced by from the nominal window center, with standard deviation and symmetric half-width . If is the standard normal distribution's cumulative distribution function,At zero offset and , the retained fraction is approximately . Shifting the peak center to the upper window boundary, , reduces it to approximately . The model's total peak area has not changed; the selected fraction has.
A wider window admits more of this peak but can also admit another ion. The measured window sum can therefore increase for two different reasons: greater target capture or added interference. They cannot generally be distinguished from the summed trace alone.
The Gaussian shape is a stipulated teaching model, not a universal instrument response. Real peak asymmetry, finite recorded ranges, background and overlapping signals can change the fraction. Mass resolving power and mass-coordinate accuracy remain instrumental properties; a software window only selects from the information available.
An extracted-ion chromatogram peak area integrates selected ion signal over a stated chromatographic time interval, usually after estimating an extracted-ion chromatogram baseline. If is an extracted ion chromatogram for mass window and is its baseline,Both the extracted ion mass window and time boundaries are part of this definition. The selected-ion/time character follows the IUPAC extracted ion profile definition.[ref]
An original nonuniform-sampling example uses times minutes and signals . With baseline 1, corrected signals are . Straight-line interpolation and the trapezoidal rule giveThe discrete corrected-signal sum is 6, which ignores the acquisition intervals. Neither number is an amount of analyte without a response calibration.
Baseline error accumulates across the integration interval. Over this four-minute interval, overestimating a constant baseline by 0.5 signal units reduces the assigned area by signal-unit minutes, from 7 to 5. A broad weak feature can therefore be especially sensitive to its baseline convention.
Peak area can also include neighboring ions admitted by the mass window and coeluting compounds with the same recorded coordinate. More complete integration does not by itself make the assigned signal chemically specific. State boundaries, baseline, handling of negative corrected values and integration rule. Those choices can alter reported area even when the recorded spectra are unchanged, and differences in area need not mean proportional differences in analyte amount.
Exciton condensation is collective quantum coherence of electron-hole pairs or excitonic degrees of freedom. A finite exciton population alone does not establish it; the central issue is macroscopic phase coherence or the corresponding ordered state.
The physical setting matters. Long-lived excitons in a semiconductor, electron-hole bilayers and driven exciton-polariton systems have different conservation laws, decay channels and interactions. A spectral feature or an increase in emitted intensity therefore needs supporting coherence and dynamical evidence before being interpreted as condensation.[ref]
Bose-Einstein Condensation of Excitons in Cu2O: Progress Over Thirty Years by David Snoke and G. M. Kavoulakis. review of experimental criteria and exciton systems
A Rydberg exciton is an excited bound electron-hole state with a large principal quantum number. Like a Rydberg atom, it can have a large spatial extent and strong sensitivity to external fields, but its energies and size are modified by the semiconductor's effective masses and dielectric response.
A descent of a permutation written in one-line form is a position with . Its descent set and number areThese are adjacent comparisons, unlike inversions of a permutation, which compare arbitrary ordered pairs of positions.
For , the descents occur at positions one and three, since and . The middle comparison is increasing. The identity permutation has no descents, while the reversed order has .
The Eulerian number counts permutations with descents under the stated indexing convention. The major index instead sums their positions; for it is , illustrating a different statistic derived from the same descent set.
With the upward-starting convention, an alternating permutation of has one-line entries satisfyingFor , the possibilities are and . Reversing every inequality gives the downward-starting convention; complementing each label by is a bijection between the two conventions.
These permutations are counted by the Euler zigzag numbers for one fixed initial direction. For , counting both directions doubles that count. For lengths zero and one, the inequality condition is vacuous, so the direction classes coincide instead.
Alternating refers to the succession of inequalities, not to membership in the alternating group. For example, is upward alternating but is an odd permutation: it swaps two labels. This distinguishes an order pattern from permutation parity.
A basis of a Euclidean lattice is a list of linearly independent vectors such thatThe coefficients must be integers: a real basis spanning the same ambient vector space need not generate the same Euclidean lattice.
For , the vectors form a lattice basis, because . The independent pair instead generates only points with even first coordinate. Writing basis vectors as columns of , another matrix is a basis of the same lattice exactly when is an integer unimodular matrix, with determinant . The covolume is ; basis changes preserve it. This separates changing a description from changing the discrete set itself.
Pinned article: Introduction to the OurBigBook Project
Welcome to the OurBigBook Project! Our goal is to create the perfect publishing platform for STEM subjects, and get university-level students to write the best free STEM tutorials ever.
Everyone is welcome to create an account and play with the site: ourbigbook.com/go/register. We belive that students themselves can write amazing tutorials, but teachers are welcome too. You can write about anything you want, it doesn't have to be STEM or even educational. Silly test content is very welcome and you won't be penalized in any way. Just keep it legal!
Intro to OurBigBook
. Source. We have two killer features:
- topics: topics group articles by different users with the same title, e.g. here is the topic for the "Fundamental Theorem of Calculus" ourbigbook.com/go/topic/fundamental-theorem-of-calculusArticles of different users are sorted by upvote within each article page. This feature is a bit like:
- a Wikipedia where each user can have their own version of each article
- a Q&A website like Stack Overflow, where multiple people can give their views on a given topic, and the best ones are sorted by upvote. Except you don't need to wait for someone to ask first, and any topic goes, no matter how narrow or broad
This feature makes it possible for readers to find better explanations of any topic created by other writers. And it allows writers to create an explanation in a place that readers might actually find it.Figure 1. Screenshot of the "Derivative" topic page. View it live at: ourbigbook.com/go/topic/derivativeVideo 2. OurBigBook Web topics demo. Source. - local editing: you can store all your personal knowledge base content locally in a plaintext markup format that can be edited locally and published either:This way you can be sure that even if OurBigBook.com were to go down one day (which we have no plans to do as it is quite cheap to host!), your content will still be perfectly readable as a static site.
- to OurBigBook.com to get awesome multi-user features like topics and likes
- as HTML files to a static website, which you can host yourself for free on many external providers like GitHub Pages, and remain in full control
Figure 2. You can publish local OurBigBook lightweight markup files to either OurBigBook.com or as a static website.Figure 3. Visual Studio Code extension installation.Figure 5. . You can also edit articles on the Web editor without installing anything locally. Video 3. Edit locally and publish demo. Source. This shows editing OurBigBook Markup and publishing it using the Visual Studio Code extension. - Infinitely deep tables of contents:
All our software is open source and hosted at: github.com/ourbigbook/ourbigbook
Further documentation can be found at: docs.ourbigbook.com
Feel free to reach our to us for any help or suggestions: docs.ourbigbook.com/#contact





