Bloch nuclear induction experiment Created 2026-10-18 Updated 2026-10-20
In their 1946 letter, Felix Bloch, William Webster Hansen, and Martin Packard reported water at room temperature. A steady magnetic field along and an oscillating field along produced a signal in a pickup coil along , displayed on an oscilloscope. Some samples included paramagnetic additives to accelerate thermal equilibrium. Resonance fields at two frequencies gave the same field-to-frequency ratio, consistent with the proton value.[ref]
The detailed paper describes glass water bulbs inside tuned receiving coils. Transmitter coils, shields and a conducting paddle controlled leakage. Field modulation at 60 Hz drove the horizontal oscilloscope sweep. A diode and audio amplification supplied the vertical trace. Vibration changed coupling: their largest difficulty. Coil tuning capacitors formed tank circuits. The actual receiver omitted the conceptual diagram's radiofrequency amplifier.[ref]
The orthogonal coil axes suppress direct transmitter pickup, but do not eliminate it. A field-dependent signal at the nuclear resonance must be distinguished from leakage and noise; merely detecting a radiofrequency voltage is insufficient. This is why the field sweep and the independently checked field-to-frequency ratio matter.
Current-polarity dead-time compensation adjusts a switching command to oppose the dead-time output-voltage error predicted from the direction of load electric current. During bridge switching dead time, an inductive current can flow through a MOSFET body diode; the resulting rail clamp makes the cycle-average error depend on current direction. The manufacturer’s bridge-state diagrams establish that current-path mechanism.[ref]
Consider an original ideal half-bridge model with rail separation , switching period , duty fraction , and effective dead-time fraction . Assume current has one nonzero sign throughout the affected interval and that device drops are negligible. Let positive current leave the midpoint, so that the adopted clamping model gives
For a desired normalized average , choose
Substitution cancels the average error in this model. The correction changes the commanded pulse duration; it does not remove the nonoverlap needed to avoid H-bridge shoot-through. Different full-bridge switching patterns require applying the appropriate event model to each leg before subtracting the terminal averages.
For , and , and the uncompensated error magnitude is . At , use for positive current and for negative current. Each gives the intended average under the stated assumptions.
Command limits matter. Suppose the allowed duty range ends at because a minimum off-time is required. With positive current and , the formula asks for . Clipping to leaves an actual normalized average of , an error of at this bus potential difference. Thus a compensation law can be correct locally while the requested average lies outside its achievable range. Minimum pulse durations impose further limits.
Current-sign uncertainty in dead-time compensation is particularly important near a zero crossing. If an estimated sign is used while the actual sign is , the residual error, before command clipping, is
A wrong opposite sign doubles the uncompensated error magnitude: in the example. Current-sensor delay, noise and a sign reversal within the switching interval can all invalidate a sign held constant for the cycle. Using a zero correction in an uncertain interval avoids that particular wrong-sign doubling, but does not cancel the original error.
A proposed bench comparison records gate commands, midpoint electric potential difference and load electric current together, then integrates each switching cycle with and without compensation. Compare positive-current, negative-current and crossing intervals separately, and repeat near pulse limits. This separates the average-error cancellation being tested from preservation of nonoverlap, device voltage drops and imperfect knowledge of switching delay.
A current-sign certificate from sensor delay is a bound proving that load electric current keeps one specified sign throughout a future switching interval, despite measurement error and the age of the reading. It supplies a condition under which a direction-dependent correction in current-polarity dead-time compensation can use its assumed current path. Manufacturer switching diagrams show why current direction matters: inductive current can continue through body diodes during nonoverlap.[ref]
Suppose a sensor reports for sampling time , with . The command begins at and the affected interval ends at . Assume throughout . Integrating the derivative bound gives
Thus certifies positive current throughout the interval; certifies negative current. The strict inequalities exclude a possible zero at the limiting time. A failed certificate does not prove a sign change; it means the stated information does not rule one out.
For an original numerical example, let , , sample age and . Then . A reading has a certified minimum of . If the sample could be another older because of timestamp uncertainty, use that oldest possible time: the bound becomes . Ignoring acquisition-to-controller delay would overstate the available margin.
A current-sign certificate for an averaged sensor sample must model the averaging aperture too. Suppose the sensor returns the uniform average over , plus error at most . For a future time ,
The interval certificate therefore uses . With and the preceding delay and switching interval measured from , . The same reading is no longer sufficient. The half-aperture term is justified here by a uniform averaging model; a different filter needs its own response model.
The slew bound must apply during switching, not only to the slow visible current envelope. For an ideal inductor of inductance , , so an independently justified bound on its terminal electric potential difference gives . A smaller slope measured in a quiet part of the cycle need not bound a subsequent rail-clamped interval.
Several consistent measurements can be combined. If each provides an enclosure of the current over the entire target interval, intersect those enclosures. For example, and imply the tighter , certifying positive current. An empty intersection flags inconsistent measurements or assumptions; it is not an especially strong certificate.
A proposed bench validation timestamps the sensing aperture, controller decision and actual gate transitions, while an independent current record checks the asserted error and derivative bounds. Repeat near current zeros and across the intended load range. This distinguishes a deterministic enclosure from a standard uncertainty or confidence interval and tests the complete timing chain needed by current-sign uncertainty in dead-time compensation.
Current-sign uncertainty in dead-time compensation occurs when the direction of measured load electric current does not reliably identify its direction during the switching interval being corrected. The recirculation path during bridge switching dead time depends on that direction. Manufacturer switching diagrams show how the body diodes provide paths when the controlled devices are off.[ref]
Use the ideal half-bridge model in current-polarity dead-time compensation: bus separation , period , effective delay , and an actual nonzero current sign held constant throughout that interval. Let . A commanded additive correction , where , leaves average output error
A correct sign gives zero error with . An opposite sign gives magnitude , twice the uncompensated magnitude. For , and , and a wrong full-sign correction gives error. These conclusions assume unclipped commands and the stated rail-clamping model.
A current-sign certificate from sensor delay combines measurement and motion bounds. Suppose a reading refers to time , has absolute error at most , and the true current satisfies from then through the end of . For every time in that switching interval,
This follows by adding the measurement error to the integrated derivative bound. A positive sign is certified if ; a negative sign if . Within the remaining band, neither sign is certified by those bounds. At equality, a zero can still occur, so strict sign certification requires a strict inequality.
For an original example, take , , and . Then . A reading certifies positive current, whereas permits currents from to . A sign selected solely from the latter reading can therefore be wrong. A bound covering only the sensing instant would miss the delay contribution.
Robust and probabilistic choices answer different questions. If both signs are possible and nothing else is known, the worst-case error is ; its minimum occurs at . If instead a validated conditional probability is available and mean squared error is the objective, differentiation gives
For , the optimal fractional correction is and the predicted RMS error is about for the bus example. That is a probability-model prediction, not a worst-case sign guarantee.
A proposed validation records sensor timestamps, actual load electric current, gate timing and midpoint electric potential difference on a common time base. Compare integrated cycle errors in certified and uncertified sign intervals, including crossings within the dead time. A dead band or Schmitt trigger can reduce noisy toggling, but holding a previous sign through a genuine crossing can prolong a wrong correction; the relevant test is whether the current-path assumptions and timing bounds hold.
A current-voltage characteristic describes the relation between terminal electric potential difference and electric current for specified physical conditions. A resistor obeying Ohm's law gives a straight line; a diode has an asymmetric relation.
Bridge switching dead time is an intentional nonoverlap interval between complementary conduction commands in a power-switching leg. It allows the outgoing device to cease conducting before the incoming device conducts, reducing H-bridge shoot-through. The applicable interval depends on propagation and device switching delays, not only on the timestamps of ideal logic commands. Nexperia's primary bridge discussion introduces the delay between turning off one pair and turning on the other, while retaining a path for inductive current.[ref]
For an original timing bound, command the outgoing device off at and the incoming device on at . Let be the latest possible end of outgoing conduction, and the earliest incoming conduction delay after its own command. A sufficient nonoverlap condition in this delay model is
With an additional positive timing margin , choose
The two switching directions can require different bounds. The inputs must cover the operating conditions for which the guarantee is claimed.
Suppose the latest turn-off completion is and the earliest turn-on delay is . Zero modeled overlap requires at least of commanded separation; a stipulated extra margin gives . Incoming conduction then starts no earlier than , leaving at least after the outgoing device has ceased. These numbers illustrate the bound rather than a particular gate-driver specification.
Longer separation also changes the output waveform. In an original half-bridge example with rails 0 and , suppose one nominal high interval per period is shortened by exactly , with the removed interval clamped to the low rail. The mean electric potential difference changes by
For , and , this is . The dead-time output-voltage error in a complete bridge depends on which intervals are replaced and on load-current direction; this one-pulse calculation does not supply a universal coefficient.
During nonoverlap, the electric current of an inductor cannot disappear instantly. Its path can pass through diodes or other permitted conducting devices, and the midpoint potential depends on that path. A proposed test records both actual transition timing and the resulting terminal waveform under the intended load conditions. It tests the timing margin and output distortion separately, instead of treating an increased programmed delay as a complete characterization.
Diode Created 2026-10-14 Updated 2026-10-18
A diode is a two-terminal component with an asymmetric current-voltage characteristic: reversing its terminal electric potential difference need not reverse its electric current with the same magnitude. Name the terminals diode anode and diode cathode . Define using their electric potentials, and take positive electric current from to . The bar in the diode symbol marks . Positive is the forward direction; negative is the reverse direction.[ref]
The asymmetry makes a rectifier possible: a sinusoid can drive electric current through a resistor on one half of each cycle. An ordinary resistor obeying Ohm's law instead reverses its electric current when the applied electric potential difference reverses. The useful idea is directional selection; the ideal diode model captures it, while the Shockley diode equation describes a smooth exponential function rather than an abrupt switch.
Diode anode 2026-10-18
The terminal of a diode at which positive forward electric current enters, with the orientation used in the ideal diode model.
Diode cathode 2026-10-18
The terminal of a diode at which positive forward electric current leaves. The bar in the diode symbol identifies this terminal.
The New Jersey Institute of Technology laboratory uses a silicon 1N4148 diode. For its forward current-voltage characteristic, the supply operates in current-source mode; a benchtop voltmeter independently reads the diode electric potential difference. Small electric current steps resolve the steep branch. For reverse measurements, a sensitive ammeter sits in series; the handout suggests a – series resistor. Reversing the applied polarity supplies the comparison. Meter placement must avoid counting the voltmeter's own electric current, and the zero reading may have an offset. The same diode is then measured with an Agilent U2722A source measure unit for graphical comparison.[ref]
The prescribed analysis uses a logarithmic scale for forward electric current to infer and from the straight region. Large-electric current departures can indicate series electrical resistance. The handout cautions that the accessible range may not determine it precisely; meter loading also matters. This is a measurement procedure, without a published set of device readings.[ref]
The reason for the logarithmic scale follows directly from the Shockley diode equation. If and series electrical resistance is negligible,
where is a fixed reference electric current making the logarithm dimensionless. The slope is , so extracting needs the junction temperature. Fitting only an appropriate interval matters: a straight-looking subset cannot establish the model at all electric currents.
Electrical impedance Created 2026-10-14 Updated 2026-10-20
Electrical impedance is the ratio of terminal electric potential difference and electric current phasors at one specified positive angular frequency . For an electrical circuit modeled as a linear time-invariant system, use the sinusoidal steady state after any decaying transient has settled. With the passive sign convention, positive electric current enters the terminal assigned positive electric potential difference. Define peak complex amplitudes by
The physical and are real; the complex numbers encode their amplitudes and wave phases. The unit of electrical impedance is the ohm, . Both phasors may instead use root mean square magnitudes, with the same ratio . A nonlinear diode can generate additional frequencies; a single then does not describe the whole response.
Write the electrical impedance in Cartesian and polar forms as
Here is the resistive real part, the signed electrical reactance, and the voltage-minus-current phase difference, defined modulo a full turn. The Pythagorean theorem gives the modulus from a right triangle in the complex plane. The complex argument gives the rotation from the current phasor to the voltage phasor. Thus , while negative means electric current leads terminal electric potential difference. For , lies between and ; outside that case, use the quadrant of the complex number rather than a bare inverse tangent. The geometric magnitude and phase difference are the two pieces of the AC relation.[ref]
Figure 1. . Original ideal series RC impedance calculation: , , . Left: , resolved into its real part and signed electrical reactance. Right: normalized predicted sinusoids with the current phasor as the zero-phase reference; their peak separation is . The plotted normalized heights do not compare volts with amperes. Details.
Multiplication by acts on phasors, not on instantaneous physical signals. For example, when ,
The second term is in phase quadrature with electric current; it cannot be represented by pointwise multiplication when . This is the useful compression: one complex multiplication replaces separate amplitude and phase difference calculations, while the real part restores the physical signal.
An ideal resistor, inductor and capacitor have , and . Their electrical impedances add in a series RLC circuit, giving . The current amplitude is , so cancellation of the imaginary parts explains the resonant series RLC response. The component-law derivation and opposite complex exponential convention are in reactance phase convention.
Envelope detector 2026-10-14
An envelope detector extracts the slowly varying nonnegative wave envelope of a rapid carrier wave. In a simple electrical version a diode charges a capacitor near positive carrier peaks and an attached resistor discharges it between peaks. When , ideal envelope extraction gives ; removing the constant leaves . This permits recovery without a synchronized carrier reference. Carrier injection thus trades transmitted power for simplicity.[ref]
A working peak detector needs margins as well as : should comfortably exceed the diode's forward-voltage scale and noise, and the time constant must suppress carrier ripple while following a falling wave envelope. The coarse scale window is
A time constant that is too short leaves carrier ripple; one that is too long makes the discharging capacitor fall more slowly than the envelope. In the ideal zero-drop, continuous-tracking approximation, following a falling requires . For ,
Differentiating the ratio locates its maximum at . This original slope check explains why operation near is demanding even before overmodulation: the upper bound tends to zero while the need to smooth carrier cycles persists. It is an approximate circuit criterion, not a guarantee in the presence of diode drops, loading or noise. At there is no varying message to track; at ideal envelope extraction remains algebraically possible, but the simple detector has no positive trough margin.
For , even an ideal noiseless envelope detector returns . Removing its mean or its original offset cannot restore the discarded sign. A more elaborate receiver can use the retained wave phase through coherent demodulation.
Half-wave rectifier 2026-10-18
A half-wave rectifier with one diode and a resistor load passes one half of each input cycle.[ref]
For an original ideal example, let an ideal voltage source supply the sinusoid , with and angular frequency . Connect its positive reference terminal to the diode anode, the diode cathode to the upper terminal of a load resistor with electrical resistance , and the lower terminal to the source return. Let be the upper-minus-lower load electric potential difference, and the downward load electric current. Assume the ideal diode model, zero source electrical resistance, and no filter capacitor, inductor or switching delay.
Figure 1.
An ideal half-wave rectifier selects the positive half-cycle
. Original schematic and calculated load electric potential difference for and . The diode cathode is the bar at ; positive load electric current flows downward through the resistor. Dashed orange: source sinusoid. Blue: load output, zero during the negative half-cycle. Green: its cycle-average electric potential difference . No smoothing capacitor is present; these are ideal model predictions. Details.
The Kirchhoff cycle law gives , and Ohm's law gives . If , the blocking assumption would give , contradicting the ideal diode model, so the diode conducts with . If , conduction would give , also forbidden, so the diode blocks. At the crossings both values vanish. Thus
The peak load electric current is . The output is unidirectional but still varies in time, reaching zero throughout every negative half-cycle. Over a period of a function , write the wave phase as . Its average value of a function and root mean square follow from two integrals:
Consequently the average load power is , not . The ideal diode has zero loss; the resistor converts supplied energy into Joule heating. The same switching argument predicts when the diode is reversed. Directional selection changes the waveform and its average value of a function; it does not by itself produce a constant output.
H-bridge 2026-11-05
An H-bridge is a four-switch arrangement that can apply either polarity of a DC supply across a two-terminal electrical load. Two switches form each side, with the load joining their midpoint nodes. Power inverters and bidirectional electric motor drives use this switching geometry. The primary TI lesson illustrates its components, forward/reverse states and inductive-current paths.[ref]
In an idealized switching model, let select the lower or upper rail at midpoint A and B, with supply magnitude . Then
Opposite choices give or across the load. Equal choices give zero terminal difference even though both midpoints can be at the upper rail. This zero-output state does not mean every switch is open.
Each leg's upper and lower devices must not simultaneously provide a low-resistance path between supply rails: that is H-bridge shoot-through. Bridge switching dead time introduces a nonoverlap interval during a transition. Inductive load electric current still needs a path during that interval, often involving diodes or controlled conducting devices. The actual current path depends on the bridge state and current direction.
An original inductor example shows why reversing the commanded terminal polarity need not instantly reverse electric current. Neglect winding electrical resistance and opposing motor electromotive force, and take with initial current . Applying gives
Current reaches zero only after about if this voltage is maintained. Initially : the inductive load is returning stored energy through the bridge rather than absorbing it. Its initial magnetic energy is .
During rapid ideal bipolar switching, applying for fraction and for the rest gives interval-average output . With and , the average is . This average does not specify instantaneous current or heating without a load model.
A proposed low-voltage observation records both midpoint potentials, differential load electric potential difference and load electric current. Comparing them through reversal distinguishes a changed switch command from changed current direction. Driver delays, device drops, recirculation and the supply's ability to accept returned energy determine how closely a real bridge follows the ideal states.
Ideal diode model 2026-10-18
The ideal diode model sets the conducting electric potential difference to zero and the blocking electric current to zero. With the stated orientation,
[ref]
The surrounding electrical circuit chooses the state and remaining value. The two branches meet at . Their product vanishes, so the ideal diode dissipates no power: .
The ideal diode model omits forward drop, reverse leakage, diode reverse breakdown and switching delay.
Figure 1.
Smooth diode models and the ideal diode constraint
. Original calculated current-voltage characteristics, not device measurements. Left: the Shockley diode equation with , , , and a constructed extension with internal series electrical resistance . The inset resolves reverse electric current in nanoamperes. Right: the two allowed branches of the ideal diode model, using the same terminal orientation. Details.
Light-emitting diode Created 2026-10-18 Updated 2026-10-20
The optical and electrical questions are different: photon energy sets a color scale, while light-emitting diode efficiency determines how much supplied energy escapes as light. The blue light-emitting diode made compact white light-emitting diodes and full-color displays practical. A modulated light-emitting diode can also supply the optical signal in a chopped-light lock-in experiment.
Figure 1.
Blue light-emitting diode: carrier injection, emitting structure and optical readout
. Original functional schematic of a representative indium gallium nitride quantum well device on sapphire, not a reconstruction of the 1989 or 1994 devices. Layer thicknesses are schematic. Separate electrical and optical readings determine different properties: terminal electric potential difference and electric current, spectrum, and calibrated escaping optical power. The arrows represent routes through the device rather than a calculated energy band profile. Source. Details.
Measuring a solar cell's current-voltage characteristic Created 2026-10-18 Updated 2026-10-20
Keep the illumination and cell temperature approximately constant. Connect an ammeter and an adjustable resistor as a series circuit across the solar cell; connect a high-resistance voltmeter across its terminals. Vary the electrical resistance and record pairs of electric potential difference and delivered electric current . This measures the illuminated current-voltage characteristic.
A load close to a short circuit estimates at . With the load disconnected, an open circuit measurement using a high-resistance voltmeter estimates at . Neither endpoint delivers useful power: vanishes there. The intermediate readings locate the maximum of and determine the solar-cell fill factor. Holding illumination fixed matters because the photogenerated electric current changes with light intensity; holding temperature fixed matters because the diode saturation current and junction response change with it.
This experiment distinguishes producing an electric potential difference from delivering energy to a load. To determine conversion efficiency as well, measure the incident power on the illuminated area, rather than equating it to a lamp's electrical rating.
Figure 1.
The maximum-power point of an illuminated solar cell lies between short circuit and open circuit
. An illustrative ideal diode model, with , shows the current-voltage characteristic and delivered power. These are calculated curves, not measured data. Details.
The illuminated area and incident power are
A photon has energy , above the silicon band gap. With one collected electron per photon,
Use the ideal-diode approximation with ideality factor , negligible shunt leakage and the same dark diode parameters under illumination. At , . The measured dark point then fixes
At open circuit the forward diode electric current balances the photocurrent:
This is below the band gap expressed per elementary charge. Excess photon energy does not translate directly into terminal voltage; much of it thermalizes.
The paper does not explicitly specify an ideality factor. If it is not taken as unity, one dark operating point cannot determine both and . The corresponding family is
Thus is a stated-model estimate, not a parameter-free inference from that one measurement.
Donor doping supplies conduction electrons to n-type semiconductor; acceptor doping supplies holes to p-type semiconductor. In the nondegenerate, fully ionized limit, majority densities are approximately and , while minority densities follow . On contact, majority carriers diffuse across the junction, exposing positive donor ions on the n side and negative acceptor ions on the p side. The depletion-region electric field points from n to p and opposes further diffusion. At thermal equilibrium the Fermi level is uniform and drift balances diffusion, with no net current.
For an abrupt junction with uniform doping and permittivity , charge neutrality gives . Poisson's equation then gives
Positive applied means forward bias: it lowers the barrier and narrows the depletion region. Most depletion width lies in the more lightly doped side. The formula assumes the depletion approximation and fails once its operating assumptions break down.
forward bias increases minority densities at the depletion edges by the factor . In the neutral material, the steady diffusion–recombination equation gives exponentially decaying excess minorities, with lengths and . Taking the carrier gradients at the junction yields
This ideal diode law assumes low injection, nondegenerate statistics, negligible depletion-region recombination and series resistance, and sufficiently long neutral regions. Its exponential comes from the bias-dependent injection barrier; there is no universal abrupt “turn-on” voltage. reverse bias suppresses injection, giving an approximate current until additional leakage or breakdown matters.[ref]
Rectification uses the asymmetric current-voltage characteristic; controlled reverse breakdown enables voltage references, with current limiting. Bias-dependent depletion capacitance enables varactors. photodiodes and solar cells collect optically generated carriers through the junction field and diffusion toward it; efficient light-emitting diodes use radiative electron–hole recombination, preferably in a direct-gap material. Series resistance, high injection, trap-assisted recombination, heating and finite carrier storage explain departures from the ideal steady-state law.
A p-n junction brings p-type and n-type regions into contact. Majority-carrier diffusion initially leaves exposed ionized acceptors and donors, producing a depletion region and a built-in potential. At thermal equilibrium the electrochemical potential is constant: drift and diffusion currents cancel. The internal barrier is not a freely extractable battery voltage.
For a nondegenerate abrupt homojunction,
Here denotes forward bias and the depletion approximation is assumed. forward bias lowers the barrier and injects minority carriers; reverse bias widens the depleted region and suppresses ordinary majority injection. In the ideal diffusion regime,
Recombination can change the ideality factor; series resistance, high-level injection, leakage and breakdown limit this simple Shockley diode equation. The original junction theory explicitly treats both electron and hole currents, which is essential to carrier injection and transistor action.[ref]
As a rectifying diode, the junction conducts strongly in one bias direction and weakly in the other before breakdown. This permits power rectification, signal detection and electronic switching. Stored minority charge affects turn-off time, so a static exponential current-voltage relation alone does not specify switching speed. A junction capacitance varies with reverse bias and can be used in a voltage-controlled capacitor; heavily doped or high-field junctions can instead exploit controlled tunnelling or avalanche breakdown.
In a photodiode, absorbed photons generate electron-hole pairs and the depleted-region field assists collection. reverse bias widens the collecting region and can improve speed, but adds dark-current noise and breakdown constraints. In a solar cell, the same carrier generation supplies current against an external voltage. An ideal illuminated characteristic is : at open circuit the forward diode current balances photocurrent, while useful power is taken at an intermediate operating point. Neither short circuit nor open circuit delivers power to a load.
A forward-biased light-emitting diode injects electrons and holes that can recombine radiatively. Efficient emission favors suitable direct-gap materials and carrier confinement; the characteristic photon energy is near the semiconductor band gap. nonradiative recombination, escape losses, series resistance and heating limit efficiency. Two coupled junctions also form a bipolar junction transistor: an emitter injects minority carriers through a thin base, and a reverse-biased collector collects them. Useful current gain depends on efficient injection and limited base recombination, not simply on joining any three arbitrary regions.
These functions are experimentally distinguished by measuring dark and illuminated current-voltage curves, bias-dependent capacitance, transient switching or optical emission, with controlled temperature and current limits. The common mechanism is bias-controlled carrier injection or collection at a depletion barrier; the device geometry and operating mode determine which function is useful.