Charles D. Harris 2026-11-05
Charles D. Harris is the first named author, with James A. Blackwell, Jr., of the 1972 NASA report testing rear-upper-surface changes on a supercritical airfoil. The experiment examined a local off-design velocity peak while also checking the consequences at the design condition. The published summary reports that the particular attempted change adversely affected design-condition drag.[ref]
Wind-tunnel Investigation of Effects of Rear Upper Surface Modification on an NASA Supercritical Airfoil by Charles D. Harris and James A. Blackwell, Jr.. Byline, Summary and Introduction, printed pp. 1–2
The tests covered Mach numbers from to in a transonic wind tunnel. The models differed in rear-upper-surface shape while retaining their trailing-edge thickness; pressure measurements and a wake rake connected the geometric change to aerodynamic observations.[ref]
An original comparison shows why an improvement needs its operating condition. Stipulate that a proposed modification changes drag coefficient by at one condition and at another. With the same reference dynamic pressure and area for this arithmetic example,gives and , respectively. The sign of the benefit reverses. These invented coefficients are not values reported by Harris; they isolate why suppressing one local feature cannot establish lower total drag throughout an operating range.
A useful experimental comparison therefore records the Mach number, Reynolds number, angle of attack, loading and surface condition with the measured pressure coefficient distribution and drag. Changes of boundary-layer transition or mounting effects can alter the result. The documented negative outcome is scientifically informative because it tests a specific geometric proposal rather than assuming that a locally smoother-looking flow must improve complete performance.
Common-origin pressure-tap position error 2026-11-05
A common-origin pressure-tap position error shifts several inferred tap positions together relative to a fixed physical reference. It is a shared contribution to correlated position errors of pressure taps, not an independent placement error for every hole. Whether it affects a pressure-derived load depends on which references are held fixed.
For dimensionless chord coordinate , suppose the uncertain displacement is the same scalar for every tap. A first-order Taylor expansion of the pressure coefficient gives . For a reconstruction with fixed quadrature weights,The position covariance matrix is , a rank-one matrix. Squaring each tap's contribution before adding would discard the shared covariances. The covariance terms belong in the general propagation of uncertainty.[ref]
An original locally linear example takes eight equal weights , equal local slopes and . The reconstructed coefficient has standard uncertainty . Incorrect independence would give . If a two-dimensional load per span is with stipulated dynamic pressure Pa and airfoil chord m, these become and N/m. The chosen slopes describe a sensitivity model, not measured airfoil data.
Opposite-signed sensitivities can cancel the shared contribution. Conversely, repeating coordinate readings without independently checking the misplaced datum cannot average away its fixed error. A proposed test measures an independent reference mark and deliberately translates the assumed origin in the reconstruction, comparing the observed load sensitivity with the derivative above. If moving coordinates also changes the integration weights, those additional derivatives must be included.
Pressure-tap datum cancellation is a different situation. When the tap, leading edge and trailing edge are all expressed through the same affine map , with ,The common origin and scale cancel exactly. Merely translating a shared coordinate system causes no physical tap misregistration. Affine pressure-tap coordinate calibration must therefore state whether the datum is shared or independently fixed before assigning a common-origin uncertainty.
D'Alembert's paradox 2026-10-13
Ideal steady flow with incompressible flow, inviscid flow and irrotational flow can predict zero drag on a body that has nonzero drag in a real fluid. The zero-circulation cylinder pressure coefficient distribution gives an explicit cancellation example; viscosity and flow separation are absent from that model.
Dynamic pressure 2026-10-14
Dynamic pressure is the bulk kinetic energy per unit volume associated with fluid motion at speed in a specified reference frame:Here is mass density. The word "pressure" identifies its units and its use as a pressure scale; is not an extra isotropic stress to add to the local static pressure in every surface traction. A stationary fluid can have large static pressure with . Conversely, knowing and fixes without fixing static pressure. The definition remains useful in viscous fluid flow and compressible flow, even when the simplest Bernoulli equation is inapplicable. [ref]
For stipulated mass density and reference speed , . At with the same mass density, . This quadratic scaling makes dynamic pressure a useful normalization for the lift coefficient, drag coefficient and pressure coefficient; it predicts four times a particular force only if its corresponding coefficient remains unchanged.
The connection with stagnation pressure requires hypotheses. For steady flow, constant mass density, inviscid flow, and gravity as the only body force, the Bernoulli equation gives, along one streamline,Here is static pressure, is gravitational acceleration, and is height. Bring that flow to rest without losses at the same height and the limiting static pressure is the stagnation pressure :There must be no intervening pump supplying work or other energy input. Constancy along one streamline does not assert equal on all streamlines; irrotational flow in a connected region supplies that additional conclusion. Changing height requires retaining . In compressible flow the stopping pressure difference generally differs from , and viscous dissipation can reduce recovered stagnation pressure. [ref]
A Pitot-static tube turns this relation into a measurement: its upstream-facing opening senses stagnation pressure, while separate side openings sample static pressure. Connect these to the positive and negative ports of a differential pressure transducer or manometer. Under the hypotheses above, the measured difference givesThus the stipulated and imply , not an independently measured speed. Align the probe with the incoming flow and keep its passages clear: blockage and pinched tubing invalidate the comparison. At very low speed, the difference can be smaller than instrument error; at high Mach number, compressibility and possibly a shock wave require a different reduction. [ref]
A useful control is differential-pressure calibration. For a digital manometer, zeroing establishes the reading at equal port pressures; it does not establish the gain away from zero. The manufacturer's Series 475 Handheld Digital Manometer: Specifications - Installation and Operating Instructions by Dwyer Instruments, Inc. directs the user to vent both ports to the atmosphere before zeroing. Its stated accuracy is a fraction of full scale, not of the reading, and depends on instrument temperature. Select a suitable range and record the instrument variant and units; the manual covers several ranges.[ref]
Series 475 Handheld Digital Manometer: Specifications - Installation and Operating Instructions by Dwyer Instruments, Inc.. p. 1: Specifications, Model Chart and ZERO instructions
An independent physical check can use a liquid-column manometer: apply a stable pressure difference to both instruments and compare the digital reading with the hydrostatic pressure inferred from the vertical level difference. For equal-height connections carrying a gas of mass density above a manometric liquid of mass density ,This follows by balancing hydrostatic pressure down and up the two connected columns. Use vertical height, even if a tube is inclined. Known mass densities, measured height and gravitational acceleration set the comparison scale. Check several differences across the working range and reverse the port connections to check the sign. This is a proposed independent check, not a claim that the cited teaching experiment performed a full instrument calibration. Recheck zero after reconnecting the sealed tubing; a zero adjustment alone cannot detect a blocked passage or an incorrect scale.
James A. Blackwell, Jr. 2026-11-05
James A. Blackwell, Jr. coauthored NASA's 1972 study of rear-upper-surface modifications to a supercritical airfoil with Charles D. Harris. The report connects specified shape changes with measured aerodynamic loads.[ref]
The apparatus combined surface pressure orifices with a downstream rake for the fluid wake, in the Langley 8-foot transonic wind tunnel. Surface readings characterized the pressure coefficient distribution, while wake measurements supplied separate information for drag. These observations constrain different parts of the aerodynamic response.[ref]
Wind-tunnel Investigation of Effects of Rear Upper Surface Modification on an NASA Supercritical Airfoil by Charles D. Harris and James A. Blackwell, Jr.. Printed pp. 4–6, Apparatus and Techniques
An original pressure-load example illustrates that distinction. On normalized airfoil chord , stipulate two lower-minus-upper pressure coefficient distributions,Both integrate to one, giving the same chord-normal pressure force. Their first moments differ:At dynamic pressure and airfoil chord , both loads are . In this chord-normal-load model, nose-up-positive pressure moments about the quarter-chord are instead and per metre of span. Equal integrated force therefore does not establish equal load location or pitching moment. These profiles are invented, not reconstructed report data; a measured pressure distribution also does not by itself include the full viscous stress contribution to drag.
Lift (force) Created 2026-10-13 Updated 2026-11-05
Lift is the component of the fluid force perpendicular to the far-field flow relative to the body. It need not point vertically: a tilted flow changes the lift direction, and a banked wing can produce a sideways component. In a planar problem choose a unit vector along the incoming relative velocity and a perpendicular unit vector pointing towards the chosen positive-lift side. ThenHere is drag and is signed lift; means a force towards the opposite side. In three dimensions the plane perpendicular to also admits a separate side-force direction, so a lift axis must be specified. Lift is also distinct from buoyancy, which can exist without a relative flow. [ref]
https://www1.grc.nasa.gov/beginners-guide-to-aeronautics/aerodynamic-forces/. NASA Glenn, Aerodynamic Forces: components relative to the flow
The force comes from adding local surface tractions, rather than assigning a single pressure to each side. Let be the wetted body surface and its unit normal vector pointing out of the body into the fluid. The pressure contribution pushes inwards; the viscous stress tensor also contributes, including tangential shear stress:Using a constant reference pressure is legitimate on a closed surface because . This surface integral makes the direction explicit: a surface-normal force is generally neither pure lift nor pure drag. Pressure and skin shear stress both enter the resultant, although the pressure term usually dominates lift on an airfoil. [ref]
https://www1.grc.nasa.gov/beginners-guide-to-aeronautics/aerodynamic-forces/. NASA Glenn, Aerodynamic Forces: pressure and shear contributions
The lift coefficient isolates a useful scale. For a finite wing of reference area (normally its projected planform area), and for a two-dimensional airfoil section of chord length , respectively,Here is dynamic pressure, is far-field mass density, and is lift per unit span, with units . The signs of and follow the chosen lift axis. For stipulated values , , and , and . Doubling gives four times the lift only if stays fixed: changes in Reynolds number, Mach number, surface condition or angle of attack can change it. [ref]
https://www1.grc.nasa.gov/beginners-guide-to-aeronautics/lift-coefficient/. NASA Glenn, Lift Coefficient: normalization and similarity limits
A motivating experiment is to compare two independently observed quantities: the lift registered by a force balance, and the lift inferred from surface pressures. A low-speed wind tunnel holds the model fixed while air passes it at adjustable speed; a calibrated balance measures forces, while small flush holes on both surfaces connect by tubing to differential-pressure sensors referenced to . Iowa State's GA(W)-1 teaching model has taps around a chord; its instructions give their coordinates and close the contour by repeating the first tap. A classroom comparison can combine this pressure-panel method with a balance on the same model; this is an experiment design, not a claim that those instructions report a combined measurement. [ref]
https://www.aere.iastate.edu/~huhui/teaching/2026-08F/AerE344/lab-instruction/AerE344L-Lab-05-Pressure-Airfoil-instruction.pdf. Hui Hu, Iowa State, AerE344 Lab 05, p. 2: GA(W)-1 taps and pressure panels
[ref]https://www1.grc.nasa.gov/beginners-guide-to-aeronautics/drag-measurement/. NASA Glenn, Drag Measurement: force balances and calibration
Before turning on the wind, apply known positive and negative loads to the balance through its resolving centre; use for the known load from a mass. Record all balance channels during loading and unloading, including response to drag and torque loads, to detect cross coupling, hysteresis and zero drift. Record a wind-off tare at each model orientation so its gravitational weight does not become an aerodynamic lift reading. Map tunnel flow direction and uniformity, rather than using the fan setting as a speed measurement. Covert's MIT guide describes these calibration, tare and flow-survey requirements. [ref]
https://ocw.mit.edu/courses/16-621-experimental-projects-i-spring-2003/f38ecde8773fd36c0d8f9069e6aa1df5_student_wt_guide.pdf. Eugene E. Covert, A Student's Introduction to the Wright Brothers Wind Tunnel at MIT, pp. 3–8
For each pressure channel, apply zero and several known pressure differences spanning the expected range; determine the voltage-to-pressure relation and recheck it after a run. Inspect tubing for leaks and blocked taps, and wait for readings to settle before averaging: tubing can delay a pressure signal. This calibration principle is used in NASA's electronically scanned pressure systems, where several applied calibration pressures determine each sensor's response and repeated calibration tracks drift. A simple pressure standard can instead use a liquid-column height difference and the hydrostatic pressure law. [ref]
Measure far-field static and total pressure outside the model's fluid wake; in low-speed incompressible flow their difference gives by the Bernoulli equation, so . Record temperature and ambient pressure to determine mass density using the ideal gas law. At fixed , step the angle of attack, repeat selected settings, and sweep back down to check reproducibility. Record balance lift, each tap's mean pressure, and fluctuation sizes. NASA describes pressure probes connected to differential transducers and emphasizes recording their reference pressure. [ref]
https://www.grc.nasa.gov/www/k-12/airplane/tunptm.html. NASA Glenn, Total Pressure Measurement: probes, tubing and pressure references
Convert each tap to a pressure coefficient . For consecutive taps bounding a panel of length with outward normal vector , a trapezoidal rule estimate of the pressure force per unit span isCompare this with balance lift divided by span only when the spanwise flow is approximately uniform. Agreement tests the pressure-resultant picture; disagreement calls for checking unresolved leading-edge pressure variations, skin shear stress, support loads and three-dimensional end effects before rejecting it. A force balance senses the total load, while taps alone reconstruct the pressure part. Tunnel walls and model blockage alter the effective flow and require corrections; end plates or a model extending between walls approximate two-dimensional flow but do not guarantee it. Record the Reynolds number and Mach number with the result, and do not interpret tunnel lift coefficients as universal wing data. [ref]
https://ocw.mit.edu/courses/16-621-experimental-projects-i-spring-2003/f38ecde8773fd36c0d8f9069e6aa1df5_student_wt_guide.pdf. Covert, pp. 8–9: flow characterization and wall effects
[ref]https://www1.grc.nasa.gov/beginners-guide-to-aeronautics/lift-coefficient/. NASA Glenn, Lift Coefficient: Reynolds and Mach number dependence
Pressure coefficient 2026-10-14
The pressure coefficient compares a local static pressure with a specified reference static pressure, using a fixed reference dynamic pressure:The reference mass density, speed, pressure and location must accompany a reported pressure coefficient. Keep the same throughout a surface distribution; replacing it by local gives a different quantity and fails at a stagnation point. The definition itself requires neither Bernoulli's principle nor inviscid flow, so measured pressure coefficients remain useful when those idealizations fail.
Positive means ; zero means equality; negative means . This sign does not specify the sign of absolute pressure. For stipulated absolute and , gives absolute: a deficit, not a negative absolute pressure. If equals atmospheric pressure, the numerator is gauge pressure; a wind tunnel's reference static pressure need not equal room atmospheric pressure. These are reference choices, not different physical pressures.
Under the same-height, constant-mass density , steady flow and inviscid flow hypotheses of the Bernoulli equation, and with the same Bernoulli invariant as the reference flow,The first equation immediately gives the second after subtracting and dividing by . Hence a lossless stagnation point has , gives , and gives . For a real stationary wall satisfying the no-slip boundary condition, the velocity is zero right at the wall; inserting that wall velocity in an inviscid flow formula would wrongly predict everywhere. A thin boundary layer approximation instead relates the wall pressure to the outer-flow pressure and uses the outer velocity where the Bernoulli equation applies.
For potential flow around a circular cylinder of radius with zero circulation, the surface tangential velocity is . Thus the ideal pressure coefficient isWith measured from downstream, the front is at and the rear at zero. Both ideal stagnation points have , while the sides at and have . This exact model is a useful baseline for an experiment; its complete rearward pressure recovery is not a prediction for a separated real fluid wake.
To obtain a force, integrate the local normal contributions with their directions. Let be the unit normal vector from the body into the fluid and its closed wetted surface:The second equality removes a spatially constant reference pressure over the closed surface; it does not remove a nonuniform hydrostatic pressure or justify dropping the reference term on an isolated open patch. A negative contributes outwards in this reference-subtracted calculation, even though a positive absolute pressure still pushes inwards locally. Project onto the chosen lift and drag directions. The full fluid force also includes from the viscous stress tensor, including tangential shear stress; pressure tapping does not measure that contribution.
For the two-dimensional cylinder, force per unit span follows from per unit span and :Substituting gives : opposite points have identical pressure coefficients and opposite normal vectors. Zero drag despite a strongly nonuniform pressure is the instructive limitation associated with D'Alembert's paradox. Real viscosity, boundary layers and flow separation can prevent rearward pressure recovery and produce pressure drag. Thus the measured curve can test the model and estimate a pressure contribution without proving that total drag vanishes.
A motivating measurement is Virginia Tech's Experiment 3 - Flow Past a Circular Cylinder. Its open-jet wind tunnel holds a rotatable cylinder with end plates and 36 one-millimetre pressure tappings at ten-degree intervals. A reference Pitot-static tube supplies and to one digital manometer; a second connects a surface tap to its positive port and reference static pressure to its negative port. Record the simultaneous readings:The last equality uses the low-speed stopping relation, not an additional speed measurement. The manual requires sealed tubing and zero checks with the tunnel off. It also provides a water-column manometer: read each column's initial level, and subtract the independently measured reference-to-atmosphere pressure from the tap-to-atmosphere readings. Record tap positions after rotation. Compare the two instruments and check spanwise uniformity; end plates do not guarantee two-dimensional flow. [ref]
The inferential distinction matters: the manometers directly measure pressure differences, the ratio estimates pressure coefficients, and a surface integral estimates the pressure part of the force. Measure room absolute pressure and temperature if converting the reference difference to speed through the ideal gas law ; use thermodynamic temperature in that equation. For force reconstruction, cover the complete contour and use numerical integration with the tap geometry. Finite tap spacing, unknown end effects, probe disturbance and fluctuations limit that reconstruction; tubes and instruments also average or delay changing pressures. Retain the signed raw readings, repeated readings and reference readings so that these limits can be assessed. A small reference difference magnifies any zero error in the ratio, rather than producing a reliably large .
Pressure-tap position calibration 2026-11-05
Pressure-tap position calibration determines the locations assigned to pressure tappings relative to a specified model coordinate system, with corrections and uncertainties. It is a geometrical measurement calibration, distinct from calibrating the pressure transducer. A correct pressure reading cannot compensate for assigning it to the wrong point on a steep pressure coefficient profile.
A proposed practical procedure measures each hole center against visible reference marks, establishes the leading edge and airfoil chord used for normalization, and records the coordinate transformation. A calibrated imaging scale or translation stage can provide the comparison. Record repeated readings and shared datum errors separately, and check that the measured view represents the intended surface coordinates rather than an oblique projection. This is a proposed metrological procedure, not an assertion that a particular historical airfoil experiment performed it.
An affine pressure-tap coordinate calibration has the simple formwhere is the instrument coordinate, an offset and a scale. With an independently established , , and , a nominal reading gives and , rather than . For a locally linear pressure coefficient slope of , that coordinate discrepancy corresponds to .
Reference sharing matters. If the same affine map determines the tap, leading-edge and trailing-edge coordinates, its common offset and scale cancel inThis cancellation does not remove distortion, uncertain feature identification or non-affine errors. It shows why the references and their covariances must be part of the measurement model, rather than independently attached after normalization.[ref]
Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results by Barry N. Taylor and Chris E. Kuyatt. Appendix A.1 and equation A-3, complete measurement model and correlated inputs
Robert M. Pinkerton's 54-orifice airfoil experiment illustrates why spatially distributed pressure data matter: the experiment compared measured distributions with potential flow predictions.[ref]
Calculated and Measured Pressure Distributions over the Midspan Section of the NACA 4412 Airfoil by Robert M. Pinkerton. Author abstract, pressure orifices and measured/theoretical comparison
A position check tests the coordinate assignment, whereas additional taps address quadrature ambiguity of pressure-tap data; neither task substitutes for the other. Pressure-tap position error 2026-11-05
A pressure-tap position error assigns a measured surface pressure to the wrong point on an airfoil. This differs from a pressure transducer's pressure-reading error: an accurate instrument can faithfully measure the pressure at a misplaced or incorrectly labeled hole. A steep spatial pressure gradient makes a small location error important.
Let be the nominal chord coordinate and let the actual pressure tapping lie at . For a differentiable pressure coefficient profile,If the derivative is bounded by throughout the interval between the two positions, the mean value theorem gives the rigorous bound . Knowing only an endpoint slope does not establish that bound across an unresolved peak.
In an original local example, take , a physical position error , and a profile locally linear with . Then and . At dynamic pressure , the corresponding pressure difference is . These are stipulated values illustrating sensitivity, not measurements of a particular airfoil.
For fixed quadrature weights and small errors in several tap positions, put . If is their position-error covariance matrix, the first-order variance contribution to a reconstructed coefficient isThis formula retains correlated position errors of pressure taps, including a shared coordinate-origin error. It holds the reconstruction weights and surface geometry fixed; uncertainty in those also needs accounting when geometry is inferred from the same coordinates.
Pressure-tap position calibration measures the actual hole coordinates and their reference origin, alongside pressure-channel calibration. Robert M. Pinkerton's distributed-pressure experiment used 54 orifices on an airfoil model to compare a measured distribution with potential flow predictions.[ref]
Calculated and Measured Pressure Distributions over the Midspan Section of the NACA 4412 Airfoil by Robert M. Pinkerton. Abstract, pressure-orifice distribution and theoretical comparison
Such a comparison tests both where a feature occurs and how large it is; pressure-only calibration cannot fix a displaced coordinate. Quadrature ambiguity of pressure-tap data 2026-11-05
Quadrature ambiguity of pressure-tap data means that the same finite set of measured surface pressure values can be consistent with different integrated forces. A chosen quadrature rule fixes an estimate from those readings; it does not, by itself, establish the unsampled distribution. This is an instance of how finite samples do not certify quadrature accuracy.
For an original smooth example, use the normalized airfoil chord coordinate and let be the lower-minus-upper pressure coefficient difference. Put three sample locations at , and , and considerThese polynomials agree at all three taps. Both the composite trapezoidal rule and any other deterministic rule using only these same values produce identical answers for them. Nevertheless,The discrepancy is not caused by a discontinuity or mislocated tap: both profiles are smooth at every sample. At stipulated dynamic pressure and airfoil chord , the chord-normal pressure loads are and . Their relation to flow-relative lift still requires the geometric resolution explained in surface pressure integration for airfoil lift.
Additional assumptions can make an error bound possible. If a twice differentiable has a known bound over the entire chord, the local linear-interpolation remainder gives an integral error at most on an interval of width . Summing givesFor uniform spacing on this unit interval it becomes . A value of inferred only from the same sparse readings is not an independently established bound. Conversely, a justified polynomial model of fixed degree would supply different information and could remove the ambiguity.
A proposed experiment compares the pressure reconstruction with an independently corrected force-balance measurement at matched angle of attack and Reynolds number, then adds taps near suspected sharp features. Pressure-tap position calibration and repeated pressure readings address other error sources. Agreement of two sparse-data rules is a check on their chosen interpolants, not proof that an unresolved contribution is absent.
Supersonic leading edge 2026-11-05
A supersonic leading edge has an incoming edge-normal flow component exceeding the speed of sound. For a straight planar edge at leading-edge sweep angle in the convention of normal Mach number for a swept leading edge, the criterion isIt classifies a direction of the incoming velocity, rather than asserting that the same local Mach number holds over the whole aircraft wing.[ref]
Introduction to Aircraft Performance and Static Stability by Earll Murman. PDF p. 9, Basic Sweep Concept, edge-normal Mach classification
For an original example with and , . The condition can persist at larger sweep: at , even a leading-edge sweep gives : large sweep by itself does not establish a subsonic leading edge.
For , the Mach angle is . On an aft-swept half-wing the edge's angle from the downstream streamwise direction is . Thusso the leading edge lies outside the downstream Mach cone from its apex in this ideal geometry. At , whereas the example edge has . Equality is the sonic boundary and belongs to neither strict inequality.
The classification helps select a high-speed flow model. It does not determine shock wave strength, drag or flow separation without the section shape and operating conditions. A measured pressure coefficient distribution or flow visualization can test those additional predictions; naming the regime alone cannot.
Surface pressure 2026-11-05
Surface pressure, in fluid-mechanical loading, is the local pressure evaluated at a boundary such as an airfoil surface. It is a scalar field over position and time, with units of pascals. The field can vary strongly along the same body even when the surrounding free-stream conditions are fixed.
For a small surface patch with outward unit normal vector pointing from the solid into the fluid, the pressure contribution to the force isIt acts normally to the surface. Tangential viscous stress is a separate contribution. Experiments commonly compare the boundary value with a reference pressure using the pressure coefficientwhere is dynamic pressure. A coefficient is dimensionless; reconstructing the pressure difference requires the reference conditions.
For an original patch example, let , and . Then . On a patch, absolute pressure gives an inward force of ; relative to the reference pressure, the pressure-force contribution differs by outward. A negative coefficient therefore describes a reference-relative deficit, not a negative absolute pressure.
A primary wind tunnel experiment by Robert M. Pinkerton used 54 pressure orifices in a NACA4412 model and compared measured distributions at different angles of attack with potential flow predictions. Such pressure tapping observes local boundary pressures through small openings; the distribution is reconstructed from measurements at selected positions.[ref]
Calculated and Measured Pressure Distributions over the Midspan Section of the NACA 4412 Airfoil by Robert M. Pinkerton. NACA-TR-563, NTRS abstract: 54 orifices, tested incidence range and comparison with calculations
Spatial resolution of surface-pressure measurements limits what that reconstruction can establish between taps. Reference pressure, probe response and flow unsteadiness also affect the result. Surface pressure integration for airfoil lift uses the reconstructed field and surface directions to obtain an overall force; one pressure reading alone does not determine lift.