Ariane Haase Created 2026-10-18 Updated 2026-11-05
Ariane Haase coauthored a magnetostriction measurement system using Fibre Bragg gratings as optical strain gauges. The apparatus measured small samples in pulsed magnetic fields, resolving strain of order with a -kHz bandwidth at low temperatures.[ref]
High resolution magnetostriction measurements in pulsed magnetic fields using Fibre Bragg Gratings by Ramzy Daou and others. Author list and abstract, corresponding to Review of Scientific Instruments 81 (2010), 033909: fibre gauges, strain resolution and bandwidth.
Floating pinion 2026-11-05
A floating pinion has mounting freedom that permits a limited position adjustment between its mating meshes. The resulting force balance can improve load division in a split-torque transmission. Floating does not mean unsupported: bearing and shaft constraints still transmit loads, and the allowed displacement must match the intended balancing direction.
An original symmetric scalar model illustrates the mechanism. Let two opposed mesh reactions bewhere sets mean compression, represents an initial mismatch and is the pinion's balancing displacement. Assume both contacts remain compressed. Let floating-pinion centering stiffness provide support reaction , with the reaction sign chosen so that equilibrium is . ThenWith negligible centering restraint, and the reactions become equal. In the rigid-centering limit, and the original imbalance remains.
For stipulated , and , rigid centering gives forces and . Free adjustment gives and . At , displacement is and forces are and . These describe the chosen scalar model, rather than a complete face-gear support design.
The primary 2002 rig slow-rolled pinions between two face gears, applied loads through hanging masses, pulleys and cables, and used tooth-root strain gauges. Its cantilevered pinion mount allowed a balancing displacement.[ref]
Development of Face Gear Technology for Industrial and Aerospace Power Transmission by Gregory F. Heath and others. Summary, printed p. iii; Introduction, printed p. 1; Section VIII, torque calibration and split determination
The report's modified fixed-pinion comparison sent nearly all its load to one face-gear mesh, illustrating the effect of constraint in that tested assembly.[ref]Development of Face Gear Technology for Industrial and Aerospace Power Transmission by Gregory F. Heath and others. Conclusions, printed p. 84, fixed modified-idler comparison
Finite travel, friction, backlash or loss of one contact can prevent the ideal balancing solution. At low load, the condition that both model forces are nonnegative must be checked; a gear tooth engagement threshold can change the equations. Position freedom can help sharing without guaranteeing identical tooth stress or a perfectly equal torque split at every operating condition.
Force probe 2026-10-14
A force probe measures an applied force through a calibrated response. A bending beam with strain gauges is one realization; orientation and measurement calibration matter.
Mathias Doerr Created 2026-10-18 Updated 2026-11-05
Mathias Doerr coauthored a magnetostriction measurement system using Fibre Bragg gratings as optical strain gauges. The apparatus measured small samples in pulsed magnetic fields, resolving strain of order with a -kHz bandwidth at low temperatures.[ref]
High resolution magnetostriction measurements in pulsed magnetic fields using Fibre Bragg Gratings by Ramzy Daou and others. Author list and abstract, corresponding to Review of Scientific Instruments 81 (2010), 033909: fibre gauges, strain resolution and bandwidth.
Measuring transducer 2026-11-05
A measuring transducer is a device whose output quantity has a specified relation to its input quantity and is used in measurement. VIM examples include a thermocouple, a strain gauge and a Bourdon tube.[ref] A measuring transducer provides a link in a measuring chain; it need not itself display a finished measurement result.
For an original pressure readout, choose a linear modelwith pressure , output electric potential difference , transducer sensitivity , and offset . An output then corresponds to . An amplifier, analog-to-digital converter and display can follow the transducer, each contributing to the whole measuring system.
The inverse calculation exposes distinct uncertainty contributions. Holding the other inputs fixed, a small output change changes inferred pressure by ; a small offset error changes it by . An output increment corresponds to for the stipulated sensitivity, but does not establish a total measurement uncertainty of that size.
Characterize the relevant range, temperature conditions, response time and possible instrumental drift during measurement calibration. The relation can be nonlinear, in which case local transducer sensitivity is the appropriate derivative rather than one gain valid everywhere. The definition also allows input and output quantities of the same kind; it does not require changing from a mechanical quantity to an electrical one. A sensor denotes the part directly affected by the phenomenon being sensed, whereas a complete measuring chain can contain further measuring transducers.
Overhung shaft bending stress 2026-11-05
Overhung shaft bending stress is the longitudinal normal stress caused by the bending moment from a transverse load beyond the shaft's supports. It differs from twisting due to shaft-axis torque. In the ideal two-support model, the largest overhung shaft bending moment has magnitude , where is the end load and the overhang.[ref]
For a homogeneous linear elastic beam, plane sections in the beam model give longitudinal strain relative to the neutral axis. With Young's modulus ,where is the second moment of area. Thus . For a solid circular shaft of diameter , and the outermost distance is , givingAn original example uses , and . Then and . Reducing diameter to multiplies nominal stress by , raising it to about . The cubic diameter dependence makes a diameter change different from an equal percentage change in overhang.
A measurement check can place opposed axial strain gauges at one shaft station. In a simple axial-plus-bending model, readings and microstrain give axial strain microstrain and bending strain microstrain. This separates two contributions that a single gauge would mix.
The nominal formula excludes local geometric concentrations, multiaxial loading and yielding. It is not a fatigue-life prediction. Under a stationary bending direction, a rotating material point can experience alternating stress, motivating rotating shaft bending fatigue even when the external load is steady. A permissible load requires the actual geometry, material and load history.
The source's variable inductor and variable resistor are in parallel. Let their combined complex impedance beUse the left and right source terminals as the drive nodes. The upper divider has arms and ; the lower divider has arms and . At bridge balance, the detector draws no electric current and the divider midpoint electric potential differences agree, soSubstitution and cancellation at a nonzero drive frequency giveEquating real and imaginary parts yieldsThe first expression has units of resistance and the second units of inductance. Both are independent of the drive amplitude and, for ideal frequency-independent components, of the chosen nonzero drive frequency. At zero frequency the ideal inductors short their arms and the cancellation would not be valid as a measurement of .
Two applications are precision comparison of an unknown electrical resistance with calibrated standards in a Wheatstone bridge, and detecting small resistance changes in a strain gauge or resistance thermometer. Alternating-current bridges additionally compare capacitance, inductance and dielectric losses; this particular bridge determines the two parameters of a non-ideal inductor from a null measurement.
Robert R. Filler 2026-11-05
Robert R. Filler is a coauthor of experimental mechanical-engineering work on face gear transmissions. The2002 report with Gregory F. Heath and Jie Tan identifies all three with The Boeing Company in Mesa, Arizona. Their report documents design, manufacture and testing of a scaled250-horsepower proof-of-concept split-torque transmission.[ref]
Development of Face Gear Technology for Industrial and Aerospace Power Transmission by Gregory F. Heath and others. Title page; Summary, printed p.iii; Introduction, printed pp.1–2
The experiment made load balance measurable. The input pinions were slow-rolled under torque supplied through weights, pulleys and cables, while tooth-root strain gauges recorded deformation associated with load. Measurement calibration was needed to convert those indications into an estimate of the torque division. The reported full two-pinion/two-idler configuration gave approximately48% and52% at the upper and lower input-pinion meshes.[ref]
Development of Face Gear Technology for Industrial and Aerospace Power Transmission by Gregory F. Heath and others. Summary, printed p.iii; §VIII, printed pp.71–78, torque calibration and split estimation
For an illustrative normalization to100N·m total input torque, those fractions correspond to48 and52N·m. The larger branch is4% above an ideal50N·m equal share, even though the two branches differ by4N·m. The distinction matters when comparing a measured torque split with the load intended for each path. Filler's documented contribution is as a coauthor of the experimental transmission study; the result depends on the complete tested arrangement.
Split-torque transmission 2026-11-05
A split-torque transmission divides transmitted load among two or more mechanical paths and subsequently combines their contributions. Its purpose is to let several meshes carry a total load that would otherwise pass through one path. The gear torque-path load fraction depends on compatibility, stiffness, gaps and mounting; a symmetric layout alone does not prove equal sharing.
For an original idealization, refer both branch torques to the same shaft coordinate and let their common elastic twist be . With torsional stiffnesses and no initial gaps,Values and under total torque give and branch torques and . If each branch were limited to , this sharing would limit total load to ; equal sharing would permit within the same simplified capacity assumptions.
Parallel-path gear efficiency also differs from the product rule for serial stages. If input power fractions are with , and each branch delivers fraction of its input power to the common output boundary, thenFor fractions and efficiencies , the result is . Multiplying the two branch efficiencies would describe a different arrangement of power boundaries.
The primary face-gear program reported input-pinion torque division about , while its two idlers shared about . These were measured results with stated calibration limitations, not exact consequences of the layout.[ref]
Development of Face Gear Technology for Industrial and Aerospace Power Transmission by Gregory F. Heath and others. Summary, printed p. iii; Conclusions, printed p. 84, torque splits and strain/load calibration limits
A meaningful load-sharing test measures both paths over relevant load and position ranges. Strain gauges need an appropriate measurement calibration because different tooth load distributions can produce different strain responses for the same transmitted load. Floating pinions provide one mechanism for reducing imbalance, but the complete assembly and its constraints still determine the operating split.
Strain gauge Created 2026-10-14 Updated 2026-10-18
A strain gauge changes its electrical resistance with mechanical deformation, enabling calibrated deformation measurements and force probe readout.
Stress concentration 2026-11-05
A stress concentration is a localized increase of stress caused by geometry or another disturbance of the load path. Holes, notches and abrupt section changes can make the largest local normal stress much greater than a stress calculated from the total force divided by a reference cross-sectional area. A stress concentration factor is meaningful only after both the stress component and its reference have been specified.
The Kirsch equations give an instructive exact result for a circular hole of radius in an infinite, isotropic linear elastic elastic plate under remote tensile stress in one direction, using a plane stress model. Measure the polar angle from the loading direction. At the hole boundary,At , the tangential normal stress reaches , giving relative to remote stress. At , it is . A traction-free hole therefore does not require every component of its stress tensor to vanish: it requires zero traction on the radial boundary.[ref]
For a finite plate, distinguish gross and net reference areas. A plate of width , thickness and central hole diameter transmits force through gross area and minimum net area . Defining and gives the exact conversionThis is a change of normalization, not a solution for the finite plate's stress field. For an original numerical example, take , , and . The reference stresses are and . If the local maximum is stipulated as , the same physical maximum gives and . Neither number changes the local stress by choosing a different denominator.
The distinction appears in real historical measurements. In 1939, C. Dumont loaded a perforated aluminum-alloy plate in out-of-plane bending and measured strain and deflection at two loads. The reported peak tangential stress was 1.59 times the computed net-section stress, but 1.85 times the computed stress for an unperforated plate under the same bending forces. These are bending results for that geometry, rather than the infinite-plate tensile factor three.[ref]
Modern demonstrations can combine a metal plate instrumented with strain gauges and a transparent polymer viewed in a polariscope. The latter uses stress-induced birefringence; its fringes respond to differences of principal stresses. The MIT laboratory compares local and remote strain measurements with qualitative photoelasticity observations around holes and a slot.[ref]
Isotropic Linear Elastic Stress Concentration by MIT Mechanical Engineering. §§6–7, Figures 6–9 and strain-gauge procedure
The elastic stress concentration factor is dimensionless. It differs from the stress intensity factor used to describe a sharp crack's singular field. Local yielding or a crack changes the mechanical problem; multiplying a remote stress by the elastic does not, by itself, establish a failure load.
Oberlin College's documented demonstration uses a track, two collision carts, two force probes set to the range, added bars, and a laptop with a Vernier interface. Preparation consists of entering the measurement calibration, securing the force probes to the carts, and zeroing them. Rubber stoppers serve for elastic collisions, clay for inelastic collisions, and hooks with string for pulling. Comparing the two force records tests the mutual interaction; adding mass to one cart tests whether unequal masses change the equality. [ref]
Collision Carts and Force Sensors. Oberlin College, Collision Carts and Force Sensors, Apparatus, Description, and Notes: ranges, mounting, zeroing, attachments, and unequal-mass control
Vernier's force probe uses a bending beam with strain gauges; changing electrical resistance produces a voltage readout calibrated as force. Its manual recommends zeroing in the working orientation. If recalibration is needed, use an unloaded reading and a known suspended gravitational weight; for the range its example is giving . Re-zero after changing orientation. The manual quotes calibrated accuracy , distinct from the resolution of that range, and warns that the interface's data-collection rate can limit collision measurements. [ref]
The following sampling and control choices are proposed additions to that documented experiment. Level the track and check unloaded motion in both directions for slope and friction. Use a soft bumper and one interface for simultaneous records; start before contact and stop after separation. A trial sampling rate of , if supported, would put about 100 samples across a interaction. Increase the sampling rate and repeat until the peak and integrated impulse comparison are stable; a large sample count alone does not establish adequate response. Measure each total moving mass, including the force probe and added bars.
Convert both channels to the same right-positive force convention. Oppositely facing force probes can have matching raw signs because their local positive directions differ; check each sign by a gentle push of known direction before the run. Overlay and , and also examine their signed sum. Integrate both over the same contact interval to compare impulses. Repeat with added mass on one cart, exchange the probes between carts, and check unloaded zeros before and after. These controls help distinguish a physical mass change from a channel offset or gain error.
Agreement within measurement error supports the pair-interaction model over the resolved interval; it does not establish exact equality at arbitrarily short time scales. Misalignment, a loose mounting, sensor-beam dynamics, saturation, unequal timing, and zero drift can spoil the comparison. Track friction and cable pulls are additional external forces; a probe measuring bumper contact need not measure the entire net force on its cart. If a massive connector carries appreciable changing momentum, compare the full cart–connector collection rather than assuming its endpoint forces are an instantaneous cart-to-cart pair. The constructed pulse diagram above illustrates what to compare, and supplies no measurements from this apparatus.