Dielectric Created 2026-10-14 Updated 2026-10-18
A dielectric is a material in which an electric field produces electric polarization while transport of electric charge is sufficiently small for the intended use. An insulating solid in a capacitor is an example; real dielectrics can still have dielectric loss and nonzero electrical conductivity.
The important distinction is between rearranging bound electric charge and transporting mobile charge carriers through the specimen. Bound electric charges can move a little within a chemical atom or molecule, or an existing electric dipole can turn. Their averaged electric dipole moments produce electric polarization even if there is negligible steady electric current between the electrodes. A changing electric polarization does give a bound current; the absence of steady conduction does not mean that the material is electrically unresponsive.[ref]
For uniform electric polarization in a rectangular slab, polarization density gives zero bound volume charge density in the interior and opposite bound surface charge densities on the left and right faces. The electric charge has been redistributed, not created. More generally, the divergence theorem makes the cancellation explicit:
Here is the outward normal vector on the material boundary. This accounts for both bound volume charge density and bound surface charge density; omitting either can falsely suggest that an initially neutral dielectric acquired net electric charge.
An electrical insulator between capacitor plates supports a useful combination: appreciable electric polarization, little leakage electric current, and tolerance of the intended electric field. This lets a small parallel-plate capacitor store separated electric charge and recoverable capacitor energy. The comparison in dielectric capacitor response explains why specifying fixed electric charge or fixed electric potential difference changes the answer. High relative permittivity alone does not establish good insulation or a large usable energy density; dielectric loss and dielectric breakdown matter as well.
The motivating observation is that inserting an insulating material between fixed capacitor plates increases its capacitance. [ref]. To investigate this response, use two flat parallel metal electrodes with measured overlapping area and separation , a uniform specimen filling the gap, and an instrument that measures electrical impedance. Record the capacitance with and without the specimen at the same small applied electric potential difference, frequency and temperature, after capacitance measurement calibration. An increase in corrected capacitance indicates a larger permittivity, provided the geometry is unchanged. A guard electrode reduces the contribution of the fringing field of a capacitor. [ref].
For negligible dielectric loss in the parallel-plate capacitor approximation,
An air reference approximates ; it is not an exact vacuum reference. For the following synthetic example, stipulate , and the rounded vacuum permittivity . Then in this model, and relative permittivity four gives . A residual parallel capacitance of would make an uncorrected sample/reference ratio , rather than four. This additive error does not cancel in a ratio.
Figure 1.
Synthetic capacitance response to relative permittivity and frequency
. Left: the ideal scalar capacitance and a hypothetical additive stray capacitance of . Right: a hypothetical dielectric relaxation model, with , for the same geometry. The solid curve is the parallel capacitance ; the dashed curve is the loss component , not an independently measured storage capacitance. Every plotted value is synthetic. Details.
At nonzero frequency , measure both magnitude and phase of the electric current relative to the applied electric potential difference. Define , where is electrical impedance. For the stated complex permittivity convention, the ideal uniform specimen gives
Thus a parallel capacitor and electrical conductance describe the readout at that frequency; a single scalar capacitance cannot describe both components. The diagram's assumed dielectric relaxation gives and at . These are model predictions, not observations.
Repeat the reference measurement after removing the specimen and vary the small applied electric potential difference to test drift and linearity. Record specimen thickness, electrode area, contact conditions, frequency and temperature. Air gaps act as additional layers in series and can lower inferred relative permittivity; roughness, uncertain thickness and the fringing field of a capacitor limit the geometric formula. At sufficiently high frequency, the fixture itself changes the electromagnetic field, so low-frequency guarding and a lumped capacitor model require reassessment. [ref].
Dielectric strength Created 2026-10-14 Updated 2026-10-20
Dielectric strength characterizes the electric field at dielectric breakdown under specified test conditions. In an ideal uniform gap, it sets a voltage scale .[ref] The parallel-plate capacitor model consequently gives the stored energy density scale
This is a model scale, not an operating rating: fringing field of a capacitor make local electric fields differ from , while leakage and dielectric loss spend some supplied energy as heat. Comparing usable capacitor energy therefore requires insulation and breakdown performance as well as permittivity.
Electrical insulator 2026-10-14
An electrical insulator has sufficiently small transport of electric charge for its operating conditions. Insulation is a practical requirement involving electric potential difference, temperature, geometry and duration, rather than a universal claim of zero electrical conductivity. Electric polarization can be substantial in an electrical insulator; dielectric breakdown can end the insulating regime.
For an idealized uniform slab with small constant electrical conductivity , the Ohmic conductor model predicts leakage electrical resistance in parallel with capacitance . An isolated capacitor then has
This is a derived model of slow discharge, not an assertion that every leakage mechanism obeys Ohm's law. Its time scale matches charge relaxation. The fixed-charge comparison in dielectric capacitor response needs an observation time short compared with , but long enough for electric polarization to settle. During a maintained voltage, leakage consumes power as Joule heating; delayed electric polarization can add dielectric loss under changing electric fields.[ref]
Large relative permittivity alone does not rule out either mechanism.[ref]
Southern Methodist University's teaching lab, Introduction to the Parallel Plate Capacitor Lab, makes the response tangible with a capacitor assembled from aluminium foil, paper and taped wire contacts. Its instructions specify approximately foil rectangles, aligned with the paper completely separating them. A multimeter in capacitance mode supplies the readout; a ruler measures plate dimensions and a micrometer measures specimen thickness. The lab replaces the paper with other sheets, including cardstock, plastic wrap and wax paper. It asks students to keep foil area and alignment consistent, measure thickness at several positions, estimate thickness uncertainty, and wait for the capacitance reading to stabilize. These are published preparation and measurement instructions, not measured results reported here.[ref]
The inference uses each specimen's own thickness , not just a comparison of raw meter readings. With corrected capacitance and overlapping area , the ideal estimate is . A thicker sheet can give a smaller capacitance despite larger relative permittivity. This is why changing material while letting the plate gap change does not isolate electric susceptibility by itself.
Useful additional controls are to keep leads in the same positions, use capacitance measurement calibration, repeat one sheet after the others to check drift, and repeat the assembly to assess contact reproducibility. An air-gap reference must have known spacers maintaining the same separation; removing a supporting sheet and letting the foil touch is not such a reference. Record the instrument's test frequency and measurement mode when available. A capacitance display alone does not establish negligible dielectric loss or a strictly static permittivity. These are proposed controls extending the published teaching instructions.
Air gaps produce a particularly revealing systematic error. Suppose a uniform sheet of thickness and relative permittivity is separated from the electrodes by air layers of total thickness . Approximate air permittivity by vacuum permittivity, neglect the fringing field of a capacitor and use the same area in each layer. The common normal electric displacement field has magnitude , so integrating the electric field through the layers gives
If the analyst inserts the sheet thickness alone into the ideal filled-gap formula, the inferred value is
For the stipulated model and , this gives , not three. These values are calculated examples, not measured sheet properties. If total plate separation is used instead, the effective estimate is ; it still mixes the sheet and the air. Thus measuring a thickness accurately cannot compensate for an unrecognized layer.
The fringing field of a capacitor and additive lead capacitance further limit a foil measurement. Keep lateral plate dimensions large relative to separation, and use a guard electrode of a capacitor in a suitable fixture for more demanding work.[ref] A family of thickness measurements can help distinguish material response from an additive offset, but air gaps can vary with the assembly. A large, repeatable reading supports a capacitance change; extracting a material electric susceptibility requires the geometry, gaps, instrument response and dielectric loss assumptions to survive these checks. No measured relative permittivity is claimed for any of the lab's sheets.
State a time convention before using complex response: take fields proportional to , with and for a passive wave entering the material. In a homogeneous Ohmic medium, Maxwell equations with give
The ohmic-conductor complex wavenumber describes both phase advance and amplitude decay. Real constant conductivity is only a low-frequency approximation. In the Drude model, gives
with a fixed positive ionic background and no additional bound-electron contribution in this simple model. The plasma frequency marks the inertial electron-response scale. More elaborate band structure, interband transitions and nonlocal transport limit this scalar treatment.[ref]
In the collisionless nonmagnetic limit, the dispersion relation is . For ,
A crest can move faster than without carrying a new signal faster than light. Below cutoff the ideal wave is evanescent, with penetration length ; it does not propagate as an ordinary real- bulk wave. Evanescence in the lossless limit is not Joule dissipation. Nonzero collision rate gives a dissipative conductivity and smooths this ideal cutoff picture.
For a good conductor with approximately real , the spatial branch becomes
A field amplitude falls as , while intensity falls as . The phase velocity is in this limit. Magnetic and electric amplitudes are not related by the vacuum ratio: with the chosen time convention. Its positive real part is the surface resistance. The local mean heating is , consistent with electromagnetic energy flowing into the metal. skin depth is an amplitude length; interpreting it as an intensity length gives a factor-of-two error.
A transmission-line mode propagates chiefly through the dielectric between conductors, even though finite metal conductivity causes loss at its boundaries. With per-length parameters , the telegrapher's equations give, for the same convention,
Writing a forward wave as , , gives . In the low-loss regime and , set to obtain
This low-loss transmission-line attenuation separates series conductor loss from dielectric leakage loss. Average forward power falls as . In the normal skin-effect regime, reduced conducting area makes the AC conductor resistance increase roughly as ; dielectric loss can supply a separate frequency dependence. Reflection from a mismatched termination changes delivered power without being, by itself, dissipation in the line.[ref]
To test loss, compare several lengths of otherwise identical line with matched terminations, calibrate connectors and incident/reflected power, and monitor temperature. Separate amplitude attenuation from phase delay and from standing-wave minima. Bulk penetration, line attenuation and dielectric propagation speed are related electromagnetic quantities but describe different experimental geometries.
Figure 1.
Conducting-wave propagation
. Chosen dispersion and decay models. Details.
An applied electric field displaces bound charges or reorients permanent dipoles, producing electric polarization , the dipole moment per unit volume. It gives bound charges and . Define
for a linear isotropic dielectric. Then separates free charge from the bound-charge response. Electronic, ionic and orientational electric polarization respond on different timescales; real permittivity is frequency dependent, and its dissipative part describes dielectric loss.
A uniform dielectric filling a parallel-plate capacitor raises its capacitance to . At fixed charge this reduces field energy ; at fixed voltage the stored energy increases because the voltage source supplies charge and energy. Insulation and energy storage are useful applications, limited by loss and dielectric breakdown. Static interface conditions are continuous tangential and a jump in normal equal to free surface charge.
Distributed circuit model. A transmission line must be treated as a distributed system when its propagation time is appreciable compared with the signal timescale. Divide a uniform two-conductor line into elements of length . Each has series resistance and inductance , and shunt electrical conductance and capacitance . The primes denote quantities per unit length, with units , , and , respectively.
Kirchhoff's voltage and current laws give the Telegrapher's equations:
For a lossless line, , differentiation gives and the same wave equation for . The propagation speed and characteristic impedance are
A general lossless signal has and . Thus characteristic impedance is the voltage/current ratio of one travelling wave, not simply the resistance of the wires. It can be real even when the line dissipates no energy, because energy is carried away by propagation.
For sinusoidal quantities with convention , the general lossy-line formulas are
Choose the square-root branches for forward attenuation and positive forward power. The real part of is attenuation per unit length; its imaginary part is the phase wavenumber. For small losses, attenuation is approximately , using the lossless real in this estimate.
Fields and geometry. Two separated conductors support a transverse electromagnetic mode, with electric and magnetic fields transverse to the propagation axis. For a homogeneous dielectric and negligible conductor penetration, both examples below have and hence . The distributed circuit model follows from the field energy and charges in each slice.
For a coaxial cable with inner radius and inner surface of the outer conductor at , Gauss's law and Ampère's law give
The electric field is radial and the magnetic field circles the axis. Integration of voltage and field energy gives
The equal and opposite return current on the outer conductor confines the ideal external field to the annulus.
For wide parallel plates of width separated by , neglect fringing. The electric field crosses the gap, , while the magnetic field lies in the gap parallel to the plates and perpendicular to propagation, . Therefore
For a forward wave, points along the line. Integrating this Poynting vector over either cross-section gives instantaneous power . For complex peak amplitudes, average power is , or for a single forward wave on a lossless line. The conductors guide an energy flux predominantly in the dielectric between them.
Figure 1.
Electric and magnetic fields in coaxial and parallel-plate transmission lines
. Original transverse cross-sections for a forward TEM wave. Blue arrows show the electric field and orange arrows the magnetic field strength. Dots denote current out of the page and crosses current into it. Parallel-plate edge fields and coaxial conductor penetration are neglected. Details.
Terminations and reflection. At a load , require . If and are the incident and reflected voltage amplitudes there, the total current is . Thus
A matched load, , absorbs the incident power with no reflection. An open circuit has , a current node and a doubled voltage at the end. A short circuit has , a voltage node and a doubled current there. A purely reactive load on a lossless line has and accepts no average power. For real , the reflected power fraction is and the accepted fraction is .
Incident and reflected waves produce a standing-wave pattern with voltage standing wave ratio . The input impedance of a lossless length is
This gives for a short and for an open. A quarter-wave section gives , enabling impedance transformation. After a source launches a pulse, a distant termination affects it only after the reflected pulse returns; the return time is . Real conductor resistance, dielectric loss and departures from a TEM field profile limit the ideal model at high frequency.
A dielectric responds to an electric field mainly by displacing or orienting bound charges, rather than by sustaining a steady conduction current. The polarization density is electric dipole moment per unit volume. It creates bound charge
Separating these charges from free charge motivates
For an isotropic linear dielectric, , so
The electric susceptibility describes material polarization and is not the magnetic susceptibility. More generally it is a tensor and can depend on frequency, field strength and temperature.
Electronic polarization displaces an electron cloud relative to its nucleus; ionic polarization displaces positive and negative ions; orientational polarization partially aligns permanent molecular dipoles against thermal disorder. For independent permanent moments of magnitude , weak-field orientational response gives when local-field corrections and interactions are negligible. This explains a common inverse-temperature contribution without asserting that every dielectric follows that law.
At a static interface, and the tangential electric field is continuous. Bound surface charge is already included through . For a homogeneous filled capacitor, , and a reversible linear dielectric stores energy density . At fixed voltage, insertion raises the stored field energy but the voltage source also supplies energy; force arguments must include that source. At fixed charge the capacitor energy instead decreases on insertion.
At frequencies too high for a polarization mechanism to follow the field, its contribution weakens. A complex permittivity represents dissipative dielectric loss as well as phase lag; the sign of its imaginary part depends on the time convention. Strong fields can cause nonlinear response or dielectric breakdown, beyond the reversible linear model.
Permittivity Created 2026-10-05 Updated 2026-10-18
Permittivity describes how an electric field and a material's electric polarization combine into the electric displacement field. In a static, local response with linearity and isotropy, and no electric polarization at zero electric field, the constitutive equation is
Here is vacuum permittivity, while is the relative permittivity, a dimensionless quantity. The SI unit of permittivity is farad per metre, : multiplying it by an electric field in gives an electric displacement field in . A larger positive permittivity lets the same parallel-plate capacitor hold more plate electric charge at the same electric potential difference.
The material contribution is electric polarization , the electric dipole moment per unit volume. The electric displacement field and electric susceptibility satisfy
Substitution gives the first constitutive equation. The electric field here is the averaged, total field inside the material, not just the field of the external plate electric charges. The continuum approximation averages over many chemical atoms or molecules; locality means that the electric polarization at a position depends on the electric field there. Static equilibrium, fixed material conditions and sufficiently small electric fields are needed for this scalar proportionality. [ref].
For an ideal parallel-plate capacitor completely filled by a uniform dielectric, hold the free plate electric charge magnitude fixed and neglect the fringing field of a capacitor. Writing for the plate area, Gauss's law gives . Thus
The electric dipoles point along the electric field. Their surface electric charges, described by polarization density, oppose the field from the free plate electric charges. For a hypothetical dielectric with , the internal electric field is one quarter of its vacuum value, while . At fixed electric potential difference instead, the internal electric field stays approximately and the plate electric charge grows fourfold. These are different experimental constraints. [ref].
Figure 1. . An original schematic and normalized model comparison for a uniform dielectric with relative permittivity four. The arrows for electric dipole moments run from negative to positive electric charge; the two field contributions oppose each other. The bar values compare electric displacement field , , and electric polarization , which all have units . The schematic is not to microscopic scale. Details.
Permittivity is a useful material summary, not a universal constant of the material under every condition. Temperature, frequency and electric field strength can change the response. In a linear anisotropic dielectric, permittivity is a tensor, , so the electric displacement field need not be parallel to the electric field. At nonzero frequency, delayed electric polarization requires complex permittivity and may produce dielectric loss. [ref].
Total internal reflection Created 2026-09-29 Updated 2026-10-18
Total internal reflection occurs when a wave travels from higher to lower refractive index above the critical angle for total internal reflection, leaving no propagating transmitted plane electromagnetic wave normal to the interface.
At an infinite planar interface, total internal reflection returns all incident normal power in the reflected plane electromagnetic wave. Assume homogeneous dielectrics with isotropy, linearity, no dielectric loss, magnetic permeability , and positive real refractive indices . Above the critical angle for total internal reflection, both TE polarization and TM polarization have unit optical reflectance despite the external evanescent wave.[ref]
This makes total internal reflection useful for guiding light in an optical fiber: suitable internal incidence angles keep energy inside successive boundaries. Its more surprising feature is that perfect optical reflectance coexists with an external electric field. The evanescent field in total internal reflection can interact with a nearby object, as the frustrated total internal reflection experiment demonstrates.
For an original idealized example, choose , at vacuum wavelength . At angle of incidence , Snell law for electromagnetic waves gives an angle of refraction , so a transmitted light ray still emerges. At , its direction becomes tangent to the boundary. At , the proposed sine of a real angle of refraction would be : the transmitted wavevector must instead have an imaginary normal component. These are predictions for the stipulated media, not measured properties of a particular block.
Figure 1.
Constructed ray geometry just below, at, and above the critical angle for refractive indices 1.5 and 1; arrows indicate directions rather than relative powers
. Details.
A real semicircular-block experiment isolates this threshold. The University of Maryland laboratory instructions place a laser, motor-driven rotation stage and photodetector together; an aperture limits the detector voltage. The semicircular block is centered on the rotation axis, with the photodetector aligned along its flat face. The instructions identify a strong grazing-beam signal and a weaker signal just before the critical angle for total internal reflection. The readout is detector voltage versus stage angle. Retracing the incident laser beam identifies normal incidence for alignment.[ref]
The semicircular shape supplies a geometric control: a light ray passing radially through the curved face enters at normal incidence, avoiding additional entrance refraction. The weaker signal near the flat face locates a limiting angle of refraction; a vanishing remote-detector signal alone would not establish that the external electric field vanishes. Beam width and alignment limit angular resolution; no measured threshold or decay depth is supplied.[ref]