Terminal velocity under linear drag 2026-10-14
Consider a point mass of fixed mass released from rest in a stationary medium. Choose downward as positive, assume constant gravitational acceleration , neglect buoyancy, and impose linear drag with constant linear friction coefficient . Here is the signed downward velocity component; it equals speed during this descent. Newton's second law becomesThe terminal velocity balances the two forces, and the time constant controls how quickly that balance is approached:For the illustrative parameters , and , the time constant is and the terminal velocity is downward. At , the downward velocity is and the downward acceleration is . This is a toy linear drag model, not a claim that every falling object has this resistance law.
Exponential approach to terminal velocity and decay of acceleration in an illustrative linear drag model
. Details. For a proof outline, subtract the equilibrium value: obeys . The exponential decay solution and the initial condition give ; one derivative gives the acceleration. Every time constant multiplies the remaining gap by . The exact limit is reached only as . This makes the model useful for estimating a settling duration without mistaking vanishing acceleration for vanishing velocity.
Newton already analyzed vertical motion under uniform gravity and resistance proportional to velocity in Book II, Section I, Proposition III of the Principia. His geometric construction includes a greatest downward velocity, illustrating that a limiting rate can emerge from balancing a driving force and resistance. [ref]
https://en.wikisource.org/wiki/The_Mathematical_Principles_of_Natural_Philosophy_(1729)/Book_2/Section_1. Newton, Principia, Book II, Proposition III; Motte's 1729 translation
Testing a differential thermal actuator 2026-10-18
A proposed bench test can isolate the mechanism without a gas burner. Illuminate a blackened and a polished sample of matched material and geometry, record both temperatures and their relative displacement, then block the beam. Measure incident irradiance separately. Swap the surface treatments, hold the ambient temperature fixed for the illumination test, and change it with the beam blocked for a common-heating control. This is a model-based experiment proposal, not a report of measurements.
A larger response of the dark sample would support a difference in absorbed power; the displacement and cooling curves test the assumed linear thermal expansion coefficient and time constant. A stable illumination step that never reaches the switching gap challenges the chosen parameter model rather than the existence of thermal expansion. Nonuniform sample temperature, unequal losses and mechanical friction can separate the physical device from the ideal equations.
Thermal equilibration of two finite bodies Created 2026-10-14 Updated 2026-10-20
Consider two rigid bodies forming an isolated system, with fixed composition and constant whole-body heat capacity at constant volume values and . Their initial temperatures are and . Assume each body remains internally uniform, their contact stores negligible energy, no phase transition occurs and no work is done or extracted. These are stipulated model values, not material measurements.
Because , write with arbitrary fixed reference constants . The conserved relative internal energy isThis is an energy reference convention, not a claim about actual heat capacities down to zero temperature. At thermal equilibrium the two temperatures equal , so the first law of thermodynamics givesThe larger heat capacity pulls the common temperature closer to its initial value: body 1 warms by , while body 2 cools by .
Two finite bodies approach thermal equilibrium at
. Ideal model with and and contact conductance . The weighted temperature stays at and the relative internal energy stays at ; the plotted curves are model predictions. Details.To predict a timescale, stipulate a constant contact conductance , the reciprocal of the contact's thermal resistance. The rate of heat transfer into body 1 is , givingAdding proves conservation of . Subtracting gives exponential decay of the temperature difference, with time constantand thereforeExact equality is approached as in this ideal model. Changing changes the rate but not : equilibrium and the speed of reaching it are separate predictions. Real bodies can have internal temperature gradients, changing heat capacities and contact losses, so the plotted is an assumed model timescale.
Thermometer Created 2026-10-14 Updated 2026-10-14
A thermometer measures temperature through a physical response whose relation to temperature is known. Examples include the length change from thermal expansion, a change in electrical resistance, and the pressure of a gas thermometer. If the response function is an injective function over the working range, its measured value determines through the inverse function. Thermometer calibration establishes that relation for the particular instrument and measurement conditions. Two matching readings are meaningful only after calibration to a common scale and with the probes sampling comparable equilibrium states. [ref]
https://openstax.org/books/university-physics-volume-2/pages/1-2-thermometers-and-temperature-scales. Ling, Moebs and Sanny, University Physics Volume 2, section 1.2: physical responses used in thermometers
For a contact thermometer, the sensing part must reach thermal equilibrium with the region being measured. That region may differ from the rest of the object: an immersed probe near a heater can read a local temperature while the surrounding water remains cooler. A stable reading can also be a steady state set by competing heat transfer paths to the sample and the room. Good contact, adequate immersion, mixing where appropriate, and checks for spatial differences help establish which temperature the reading represents. These are measurement controls inferred from the thermal equilibrium requirement, not a guarantee that every flat trace is equilibrium.
A thermometer also changes the sample it touches. Consider an original toy calculation with an initially uniform sample at , a probe at , and constant whole-body heat capacities and . Suppose together they form an isolated system, with no work or phase transition and negligible contact energy. The first law of thermodynamics and thermal equilibrium giveThe final thermometer reading underestimates the sample's original temperature by about , although it correctly measures their new common temperature. The disturbance becomes small when the participating probe heat capacity is small compared with the sample's. A large controlled heat bath is a different limit: it supplies or removes heat while approximately maintaining its own temperature.
Waiting time is a separate issue from disturbance. Under a toy Newton's law of cooling model for a uniform probe in a maintained heat bath, a constant contact conductance givesThe time constant controls this exponential decay. For stipulated values , and , the probe reads about after one time constant and after three. These are calculated values, not an instrument specification or measured data. Real probes may have multiple relaxation times and additional heat transfer paths; choose an equilibration criterion from the required accuracy, rather than assuming that a fixed waiting time works universally.
Thermopile radiative measurement 2026-10-18
PASCO's documented lamp experiment connects a TD-8553 thermopile sensor to a millivoltmeter and places it level with a lamp filament along a meter stick. Lamp and detector axes are aligned. With the lamp off, readings at several positions establish an average ambient thermal radiation background. With the lamp on at a fixed supply setting, detector readings at different distances are compared after background subtraction. Between readings, a reflective shield prevents the detector warming; its shutter also protects the reference junction when idle. Moving the shutter can move the sensor, so fixed geometry matters. The manual's lamp limits must be followed.[ref]
Thermal Radiation System: Instruction Manual and Experiment Guide, TD-8553, TD-8554A and TD-8555 by PASCO scientific. p. 1, Radiation Sensor; pp. 9–11, Experiment 2, Fig. 2.1, procedure and calculations: alignment, lamp-off ambient readings, heat shield and distance comparison
This protocol tests whether the background-corrected electric potential difference approximately follows the inverse-square law over a suitable distance range. It is a relative electromagnetic radiation measurement; those readings alone do not calibrate absorbed power in watts. The manual treats the filament as an approximate point source.[ref]
Thermal Radiation System: Instruction Manual and Experiment Guide, TD-8553, TD-8554A and TD-8555 by PASCO scientific. p. 3, Stefan-Boltzmann Lamp; p. 11, Experiment 2 calculations: point-source approximation and comparison against inverse squared distance
For an absolute calibration, independently known absorbed power and a monitored reference temperature would be needed. A useful additional control is to repeat a fixed detector position before and after a distance sweep: disagreement reveals possible drift. These additions test the measurement chain rather than assuming that background subtraction fixes every error. A finite source, changing illuminated area, reflections, changing reference temperature, and insufficient settling can alter the measured dependence. In particular, the time constant in thermopile thermal response explains why a quick reading and a settled reading may differ. The detector infers its own absorber temperature difference; inferring the source's temperature additionally requires its emissivity, optical geometry and an appropriate thermal radiation model.
Thermopile thermal response 2026-10-18
A useful original model treats the thermopile absorber as one approximately uniform temperature with heat capacity , connected to a fixed reference temperature by thermal conductance . Both parameters are positive constants here. Let be an added absorbed power above the initial background. Linearize the outgoing heat transfer about that background. With measured from an initial state having , conservation of energy gives the first-order linear differential equationThe left side is the rate of stored energy; the two terms on the right are added power and outgoing heat transfer. The effective thermal conductance can include several paths, rather than just heat conduction along the wires. The model assumes a stable reference, negligible electrical loading, a common absorber temperature, and changes small enough for constant parameters.
For a step from zero to constant at , subtract the steady solution . The difference obeys exponential decay, so the initial condition fixesThe time constant has units . With the same constructed and , choose , and . ThenAt one time constant, the response is of its final value: . Reaching requires . A voltmeter read too soon therefore underestimates the steady signal even when its electrical calibration is perfect.
The steady ratio is in this constructed model. Halving thermal conductance doubles this ratio but also doubles the time constant if heat capacity stays fixed. Reducing heat capacity alone speeds the response without changing its steady value. Increasing gives a larger signal only at fixed individual temperature differences: adding legs can also change thermal conductance, heat capacity and electrical resistance. The algebra identifies coupled design choices, rather than predicting a particular manufactured detector.
A finite electrical resistance produces Thermal electrical noise. For nearly uniform absolute temperature and effective measurement signal bandwidth , its root mean square open-circuit voltage isHere is the Boltzmann constant. Thermal electrical noise in the sensing element is an important contribution, and the signal bandwidth enters its voltage variance.[ref]
Thermopile detectors by Hamamatsu Photonics K.K.. p. 3, §3-2 Noise, Eq. (3-2): element resistance, absolute temperature and measurement bandwidth
If identical pairs have fixed electrical resistance and fixed , then : the signal grows as while this noise grows as . The resulting signal-to-noise ratio grows only as under those assumptions. Reference temperature drift, environmental electromagnetic radiation, and meter noise remain separate limits; reducing signal bandwidth trades fast information for less integrated electrical noise. Time scale 2026-10-24
A time scale is a characteristic duration over which a specified variable or process changes appreciably. Comparing time scales helps choose a dimensionless time and identify a singular perturbation. An exponential relaxation has relaxation time constant ; a nonlinear process can have several distinct time scales.
Tracking error 2026-10-14
The tracking error used by the controller is the signed differencebetween the reference signal and the measured output. A positive tracking error means the readout is below the desired value; a negative tracking error means it is above. With exact measurement , and give . For a positive-response controlled plant, positive feedback gain in proportional control then reduces the plant output. The sign of the controller must also account for the sign of the controlled plant's response: a positive command that reduces the plant output requires a different sign choice. Kantor uses the opposite tracking error convention, , together with a minus sign in his controller; translating both signs gives the convention here. [ref]
Distinguish the controller's tracking error from the physical plant output discrepancy . If the readout has constant sensor bias , thenAll four quantities have the same units under dimensional analysis; a sensor bias is expressed in those units too. A readout that is too high by can make when the physical temperature is below the goal. Integral action integrates the tracking error it receives; it cannot infer this missing calibration information from that tracking error alone. Thermometer calibration against an independent reference addresses a different problem from tuning a feedback gain.
A motivating apparatus/model comparison is Park, Martin, Kelly and Hedengren's temperature-control laboratory: two TIP31C heaters with attached TMP36GZ sensors and heat sinks, an Arduino, a power supply, and a USB-connected computer. The readout converts sensor voltage to temperature; software records that measured output while specifying heater commands from to . For the single-heater test, one command changes in steps and the other heater stays off. Parameters are fitted to one run, then a different command sequence tests predictions without feeding measured temperatures into the simulation. The authors observe that their richer thermal model predicts the response better than the approximation with a single time constant and a delayed control input, especially after command changes. The real sensor has its own thermal lag. They also repeat the same command profile at different ambient temperatures and find changes in the response, motivating ambient-condition reporting. This experiment measures a command-to-readout response, not independently the exact heater temperature or delivered power. [ref]
https://www.researchgate.net/publication/338614896_Benchmark_Temperature_Microcontroller_for_Process_Dynamics_and_Control. Park, Martin, Kelly and Hedengren, Benchmark Temperature Microcontroller for Process Dynamics and Control, sections 2 and 3, Figures 3, 6 and 7: author-uploaded full text
The lesson for tracking error is to record three traces during a tracking test: the reference signal, the measured output, and the applied control input. Their first difference is the tracking error; a model prediction minus a readout is instead a model discrepancy. In a proposed comparison of proportional control and proportional-integral control, keep the initial temperature, ambient conditions, heater limits, and target changes fixed; run the second heater separately as a known control disturbance. Independent thermometer calibration is needed to assess physical accuracy. These are suggested controls, not additional experiments claimed for the paper. A sensor's lag, measurement noise, actuator saturation, and changed ambient conditions can all invalidate conclusions drawn from the ideal first-order model.
Two-state ion-channel gating Created 2026-10-14 Updated 2026-10-14
Two-state ion-channel gating models an individual gate as a random switch between closed and open states. Write for its open probability; this is the in the header equation. An individual gate's state is always closed or open, rather than partly open. A population of identical gates can have a fraction open near , and averaging repeated identically prepared trials estimates the same probability. A finite population's observed fraction fluctuates. See Purves and colleagues, Neuroscience, 2nd edition (2001): Ion Channels Underlying Action Potentials for single-channel steps and their population averages.
At fixed membrane potential , let constant rates govern closed-to-open and open-to-closed transitions respectively, in . This is a two-state continuous-time Markov chain. Over a short interval , an initially closed gate opens with probability , and an initially open gate closes with probability . Gain minus loss gives the deterministic ordinary differential equation for the probability:Here is the fixed-voltage limiting open probability, and is a time constant. The ratio of the rates fixes the limit, while their sum fixes the speed. With initial probability ,For a short derivation, subtract : the deviation obeys , yielding the exponential function. After one time constant, of the initial deviation remains. The solution stays between and , so it remains a valid probability. The rate and time constant formulations are described in Gerstner and colleagues, Neuronal Dynamics, §2.2.2: transition rates and channel kinetics.
For a worked toy condition A, choose and . Then , , andIn a separately prepared condition B, choose , and the same . Now , , and . Condition B approaches a higher limit more quickly. These are two stipulated constant-rate conditions with held fixed in each experiment, not an empirical function relating rates to voltage or a sequential switch between conditions. The initial need not be the limiting probability at the newly imposed voltage.
Two-state ion-channel gating: two constant-rate relaxation conditions
. Original computed probability curves, both starting at . Dashed lines show the limiting open probabilities and ; dotted lines mark time constants and . The dot marks condition A at , where . Smooth curves represent open probability or population averages, not an individual gate's random state trace or an ionic electric current. Details.In the Hodgkin-Huxley model, the rates depend on membrane potential: and . Its is the limit for voltage held at that . During an action potential, changing changes the rates and gates feed back onto through ionic electric currents; substituting the present voltage into the constant-rate solution does not solve that coupled system. Gating describes availability of a conducting pathway. Even an open ion channel carries zero net ionic electric current at its reversal potential.
The useful bridge is from abrupt random molecular events to a smooth population prediction. A channel requiring several independent permissive gates in an ion channel has an open probability equal to their product; this can make channel availability much smaller than each gate's availability. The Hodgkin-Huxley model uses and for sodium and potassium electrical conductances, respectively.




