Magnetoresistance Created 2026-10-18 Updated 2026-10-20
A change of electrical resistance associated with an applied magnetic field, with material, temperature, measuring electric current and preparation specified. The response can depend on magnetic history as well as the instantaneous field. A magnetoresistance measurement therefore compares defined states, rather than treating every material as a single-valued function of field magnitude.
Magnetorotational instability Created 2026-09-24 Updated 2026-10-14
The magnetorotational instability destabilizes a magnetized differentially rotating flow when angular velocity decreases outward. Magnetic tension couples neighboring fluid elements, allowing the inner one to lose angular momentum and fall inward while the outer one gains angular momentum and moves outward.
Magnetosonic wave Created 2026-09-24 Updated 2026-10-14
A magnetosonic wave is a compressive MHD mode polarized in the plane of the wavevector and background magnetic field.
Magnetosphere Created 2026-10-14 Updated 2026-10-25
A magnetosphere is the region around a body in which the body's magnetic interaction controls charged-particle motion and its response to the surrounding plasma. A planet with an intrinsic magnetic field can support a compressed dayside and an extended magnetotail in the solar wind. Magnetospheric currents must be distinguished from the internal field when inferring a planetary dynamo.
Magnetostatics 2026-10-03
Magnetostatics studies time-independent magnetic fields and steady currents. In vacuum its field equations are and .
Magnetostriction Created 2026-10-14 Updated 2026-10-18
Magnetostriction is a change of a material's shape or dimensions associated with its magnetization. A magnetic field can therefore produce strain without a contact force. The resulting magnetoelastic coupling lets a ferromagnet convert changes of magnetic state into mechanical motion; a constraint can instead turn the preferred deformation into stress. James Prescott Joule published his study of iron and steel bars in 1847.[ref]
The surprising point is that reversing the magnetization need not reverse the deformation. A material can prefer a longer axis along either or : an axis has no arrow. Isotropic linear magnetostriction vanishes excludes one particular linear constitutive term, while saturated isotropic magnetostrictive strain supplies a nonzero response with a quadratic dependence on the magnetic direction. The pulsed-field optical magnetostriction experiment shows how an actual length change can be resolved, and quadratic magnetostriction and frequency doubling separates an illustrative response law from a measured material curve.
A divergence-free magnetic field satisfying the Taylor constraint on all geostrophic cylinders. It is a compatibility condition for slow rotating-fluid balance, not a local force-free condition. To retain such a state as magnetic induction proceeds, the velocity must also preserve the time derivative of the cylindrical torque constraint.
Magnetotelluric sounding 2026-10-24
An electromagnetic method using naturally varying fields to infer subsurface electrical resistivity; conductive anomalies require geological interpretation.
Magnetron motion 2026-10-18
The slow radial normal mode of a Penning trap. Its angular frequency arises from the combined static electric field and magnetic field; it is distinct from the driven Paul trap micromotion.
Mars Created 2026-10-06 Updated 2026-10-14
A terrestrial planet with a thin present atmosphere and evidence of a different past volatile and climate history.
The 1985 spectroscopy experiment used niobium-based tunnel Josephson junctions on silicon, thermally anchored with final bias low-pass filters to a dilution refrigerator. Calibrated germanium and cobalt thermometers measured temperature. A filtered coaxial cable injected microwaves; repeated switches to nonzero electric potential difference measured escape with irradiation on and off. Bias scans at fixed microwave frequency resolved separate enhancements matching calculated unequal energy level spacings. Raising temperature merged the structure toward classical response. Junction parameters were calibrated in the classical regime; reducing the superconducting critical current with a magnetic field checked thermal readout. Parameter uncertainties limited absolute resonance positions.[ref]
The companion escape experiment mounted a tunnel Josephson junction on an attenuating coaxial cable, cold-anchored its bias filters, ramped the electric current, and counted switches to nonzero electric potential difference. Rapid current shutoff limited heating. Classical escape and microwave resonance calibrated the superconducting critical current, capacitance and environmental loading. Low-temperature escape agreed with the quantum prediction using these calibrated parameters. A magnetic field reduced the superconducting critical current to keep the same apparatus thermally activated at lower temperature, testing excess noise. Frequency-dependent loading contributed uncertainty; the predicted damping correction was smaller than combined errors, so the experiment did not resolve that correction.[ref]
Together these tests connect spectral structure and escape of the same kind of collective coordinate. They do not constitute a demonstration of coherent gate operations on a qubit, or prove that every macroscopic coordinate retains quantum behavior under arbitrary environmental coupling. The attraction is more concrete: a fabricated electrical circuit admits both an independently measurable classical model and quantitative quantum tests of its phase dynamics.
Masaki Oshikawa Created 2026-10-20 Updated 2026-10-31
Figure 1.
Portrait of Masaki Oshikawa
. External portrait hosted by Institute for Solid State Physics, University of Tokyo. Source.
Mass spectrograph Created 2026-10-13 Updated 2026-10-14
A mass spectrometry instrument with a photographic readout. In the 1919 apparatus described in Chapter V: The Mass-Spectrograph, a gas discharge produced positive ions. Two narrow slits formed a ribbon beam in a vacuum; plates applied an electric field to spread it, an aperture selected part of it, and a magnetic field bent it oppositely. Focusing reduced the spread caused by differing ion speeds, concentrating a given mass-to-charge ratio into a line on a photographic plate.
The observed quantity was line displacement from a fiducial spot. Known reference lines calibrated displacement against mass-to-charge ratio; repeated exposures with changed magnetic field tested the calibration. Evacuation limited collisions. Comparing line shapes with narrow and wide apertures helped distinguish geometric broadening from photographic spreading. Finite slit widths, plate response, and overlapping molecular or multiply charged ions limited interpretation. See Chapter V: The Mass-Spectrograph (§§33–40: apparatus and photographic procedure; §§43 and 45–46: calibration, aperture comparisons, and accuracy).
In Mass spectra and isotopes by Francis William Aston (Nobel lecture, 12 December 1922), the reported neon lines at 20 and 22 have companions at 10 and 11 from doubly charged ions. That paired pattern and comparison with reference lines support different atomic masses within one chemical element, rather than an atomic mass concentrated at the bulk average. The lecture also describes an earlier failed separation by distillation and partial separation by diffusion, showing why the focused mass spectrum supplied stronger evidence. These numbers used a historical oxygen-based reference scale. The lecture's whole-number rule was an empirical approximation at its stated accuracy, not the modern exact definition .[ref]
Mass spectrometry Created 2026-10-13 Updated 2026-10-20
Mass spectrometry separates and detects ions according to mass-to-charge ratio. It can distinguish isotopes which belong to the same chemical element but have different atomic masses. The instrument measures ions: interpreting the result as a neutral atomic mass requires accounting for electron removal and its ionization energy. For a singly positive ion in its ground state, , where is the electron rest mass, is the ionization energy, and is the speed of light.
For a simple illustrative analyzer, positive ions of mass and electric charge gain kinetic energy across an electric potential difference before entering a transverse uniform magnetic field . The Lorentz force supplies centripetal acceleration, so
At fixed and , the measured bending radius separates mass-to-charge ratios, not masses independently of electric charge. This ideal model assumes negligible initial kinetic energy and speeds small compared with the speed of light; the historical focusing mass spectrograph used the geometry described below.
The experimental achievement is to turn invisible differences between individual ions into separated, calibrated positions. Aston velocity focusing explains how an early mass spectrograph sharpened its images; the velocity-selected magnetic mass analyzer provides an independent model whose equations can be checked directly. The magnesium isotope mass spectrum shows why position, width, and intensity carry different information.
In a homentropic flow, the cross-helicity conservation law gives
Consequently cross-helicity density is conserved along each trajectory exactly when the right-hand side vanishes. In a steady state, mass conservation gives , so the criterion becomes
The absence of an entropy source in a conservation law does not alone make its density an advected scalar: compression and transport along the magnetic field still change that density.
For smooth ideal magnetohydrodynamics, write and . The continuity equation and induction equation give . The vector-potential equation becomes . Contracting these two equations cancels their velocity-gradient terms and proves
Consequently the magnetic helicity in a material volume satisfies . It is conserved when the magnetic field is tangent to the boundary. A single-valued gauge transformation changes by , which also vanishes under that condition.
Maxwell equations Created 2026-09-24 Updated 2026-10-13
The Maxwell equations are the field equations of classical electromagnetism. In SI units, in vacuum with prescribed charge density and current density , they are
Here is the electric field in volts per metre, the magnetic field in teslas, in coulombs per cubic metre, and in amperes per square metre. The constants are vacuum permittivity and the vacuum value of magnetic permeability. “Vacuum” specifies the field laws without a material response; “source-free” additionally means and . Matter described by averaged fields instead requires Maxwell equations in matter and constitutive relations.
The first equation, Gauss's law, makes electric charge a source of electric flux. Gauss's law for magnetism sets the net magnetic flux through a closed surface to zero. The two curl equations, Faraday's law and the Ampère-Maxwell equation, couple changes of the electric field and magnetic field. Appropriate initial conditions and boundary conditions select a physical solution; the two divergence equations constrain the initial fields. [ref].
Mean-field dynamo 2026-10-06
A mean-field dynamo evolves a slowly varying spatially averaged magnetic field. Correlations of fluctuating velocity and magnetic field supply a mean-field electromotive force. Its local linear response includes the alpha effect; gradients of the mean field can contribute additional transport terms. The distinction between a uniform test field used to measure a response coefficient and a spatially varying mean field used to obtain growth is essential.