Airy disk Created 2026-10-14 Updated 2026-10-14
The Airy disk is the central bright region, up to the first dark ring, in the scalar diffraction pattern of a uniformly illuminated, unobscured circular aperture. The whole pattern includes the weaker surrounding rings; its radius is distinct from its full width at half maximum.
For a circular optical pupil of diameter under normal, uniform monochromatic plane wave illumination, Fraunhofer diffraction gives
Here is the on-axis light intensity, is the angle from the optical axis, is the wavelength in the propagation medium, and is the order-one Bessel function of the first kind. The paraxial approximation replaces by , measured in radians. The first positive zero gives
This is the angular radius of the Airy disk; the angular diameter is twice as large. The Airy disk derivation explains the origin of the Bessel function of the first kind and of the numerical coefficient.[ref]
Figure 1.
Ideal circular-aperture intensity: central disk, dark rings and radial profile
. Details.
The image and both radial curves show the same calculated light intensity, divided by its peak. The image's logarithmic scale makes the weak rings visible; its colour is a display choice. The linear curve shows how small the ring peaks are compared with the centre. A dark ring marks a zero of wave amplitude, produced by cancellation across the optical pupil; it is not the edge of all transmitted light. The first Airy disk contains about of the total radiant flux, as calculated in Airy disk normalization and encircled energy.
For an original design example, take an ideal optical lens in air with focal length , circular optical pupil diameter and wavelength . In the focal plane, the radial coordinate gives
The first-zero diameter is . Solving gives , so the diameter measured by full width at half maximum is only
Thus a quoted “spot diameter” is incomplete without its definition. Doubling halves both widths at fixed wavelength and focal length; increasing magnification alone changes the image scale without improving object-space discrimination.
The Airy disk supplies a calculable reference for a point spread function, allowing diffraction to be distinguished from defocus and optical aberrations. Its beauty is that one circular boundary determines an entire sequence of bright and dark rings through a Fourier transform. The ideal formula assumes an unobscured pupil, uniform illumination, ideal optical focus, a single wavelength, and a scalar description with small output angles. A blocked centre, nonuniform pupil transmission or a significant pupil wave phase error changes the response. High numerical aperture may require polarization of an electromagnetic wave and a vector field description. The circular-aperture diffraction laboratory experiment tests the far-field pattern directly; the Rayleigh criterion uses its first zero to define a two-source convention.
Peak normalization does not make the integral of a point spread function equal to one. In the paraxial approximation to the focal plane, define and . The unit-integral point spread function normalization is
Here has units of inverse area; multiplying by the detected radiant flux gives image-plane irradiance. Its encircled energy, meaning the fraction inside radius , is
This is an integral over area, so its radial weight is . An unweighted integral of a line through the centre is a different quantity.
A short proof uses the Bessel function of the first kind identities and . They give
Both expressions for vanish at zero. Since these Bessel functions of the first kind tend to zero as , , establishing the normalization. At the first dark ring,
A circular detector region ending at the first zero therefore misses about of the ideal radiant flux, even though the surrounding rings have low peak light intensity. This matters when converting measured counts into total source brightness or choosing an image aperture for a photodetector.
Aperture Created 2026-10-05 Updated 2026-10-13
An aperture is an opening that admits light into or through an optical instrument. Its shape and size select the transmitted light rays; an aperture alone does not bend them as an optical lens does. The aperture stop is the opening that most restricts the bundle from an on-axis object point. The entrance pupil is the image of that aperture stop formed by the preceding optical lens elements, viewed from the object side. Consequently the effective collecting diameter is the entrance pupil diameter, which can differ from the physical hole's diameter. For example, preceding optical lens elements that enlarge a aperture stop by a factor of two give ; measuring the physical hole alone would misidentify the focal ratio. [ref].
For an unobscured circular entrance pupil under a uniform beam normal to its plane, the collecting area and admitted radiant flux are
where is incident irradiance. Doubling quadruples admitted radiant flux. Obstructions, nonuniform illumination and losses after the entrance pupil require the actual illuminated area and transmission to be included. The same also sets an angular diffraction-limited resolution scale at wavelength . Collection and diffraction therefore answer different questions from field of view: an aperture selects the bundle from each object point, while the receiving plane's extent helps select which object directions appear in the image.
NASA/JPL's published pinhole demonstration uses two white cards, foil taped over a window in one card, and a small hole pierced in the foil. Sunlight passes through the hole onto the second card; the projected image is viewed on that card. The activity describes a larger image when the card separation increases, improved visibility when the receiving card is shaded, and a separate image from each of several holes. These are qualitative observations of image formation, rather than calibrated measurements of radiant flux or diffraction. [ref].
A proposed quantitative extension replaces sunlight by a steadily illuminated asymmetric target and puts the foil and a translucent receiving screen in a dark box. Record target distance , hole-to-screen distance , hole diameter , image height, orientation and edge blur. Measure screen brightness with a fixed photodetector, or record the screen with an optical camera whose integration time and gain stay fixed. Exchange centred foils of measured at fixed ; then vary with the same foil. Geometrical optics predicts an inverted image with transverse magnification and a point's geometric blur diameter . Thus a larger hole admits more radiant flux without changing the central image scale, whereas increasing enlarges the image. These are predictions to test, not reported data. Keep target illumination and detector position fixed, subtract a hole-covered dark reading, repeat the original foil to check drift, and avoid clipping the detector response. Foil thickness and ragged edges can block oblique light rays; at sufficiently small , diffraction invalidates the claim that ever smaller holes always sharpen the image. A lensless optical camera has no optical lens focal length: is a propagation distance, not that focal length.
Insert a centred opaque circular stop of diameter directly in the plane of the bundle. It transmits the same directions at every surviving position, but discards the surrounding annulus. Therefore
With the uniform radiance of etendue of a circular aperture and cone, the transmitted radiant flux is and the blocked fraction is . Surviving light rays retain their radiance; the stop has not concentrated them. Lossless propagation after the stop preserves the etendue of this surviving subset, not that of the original incident bundle. A stop placed elsewhere can select positions and directions together, so its physical area ratio alone need not give the transmitted radiant flux fraction.
Basic radiance 2026-10-14
Basic radiance is radiance divided by the square of the refractive index. For radiance at a fixed wavelength,
Lossless propagation conserves reduced radiance along each light ray; itself is conserved only when the endpoint refractive indices agree. A larger irradiance at a smaller image can result from admitting more directions without increasing reduced radiance. Uniform wave absorption can lower radiant flux while leaving the occupied geometric etendue unchanged; an opaque aperture removes part of that occupied set. [ref]
Consider an ideal parallel circular beam with uniform irradiance inside radius , zero outside, and total radiant flux . A centred circular collector of radius , perpendicular to the light rays, intercepts
For and , and the collected radiant flux is . Expanding the beam to while keeping fixed divides irradiance and the same collector's radiant flux by four: and . A collector covering either entire beam still receives .
Tilting a flat collector of actual area by an angle to the beam direction gives if its entire projected area remains inside the uniform beam. At the small collector's radiant flux halves. A collector large enough to intercept the whole beam after tilting still receives : the footprint on its surface grows as and cancels the irradiance factor. This model ignores diffraction, beam-edge structure, and changes in absorption with incidence angle; it counts incident rather than absorbed power.
Figure 1.
Fixed radiant flux, different beam widths and collecting projected areas
. Original ideal geometry, not measurements. The beam cross-sections use the same centimetre scale and total radiant flux of ; both collectors have radius . The side view shows a collector's cross-section at : its projection perpendicular to the light rays has half the width, with depth unchanged. The stated half-power result requires the projected collector to stay inside the uniform beam. Details.
Use the triangular in equal radiant power under visual weighting and stipulate the detector's spectral responsivity
This model has nonnegative response: is zero outside –. For a ideal calibration line at , and , so . An equal-radiant flux test line at gives , and . The unchanged conversion indicates , whereas the model's intended weighted result is . The required spectral mismatch correction is : the uncorrected result is 50% too large. All these numbers are declared model outputs, not instrument measurements or standard photometry data.
Figure 1.
Calibration at one wavelength leaves a spectral mismatch at another
. Original schematic and analytic model. The apparatus shows the signal path of a filtered photodiode photometer, with shutter-closed subtraction; it is not a drawing to scale of a specific instrument. The lower panels use the declared triangular weighting and detector response, not CIE tables. The two ideal lines carry the same collected radiant flux; the source-dependent factor corrects the test indication within this model only. Details.
An optical power meter makes the definition operational: collect a specified beam on a calibrated photodiode, measure its electric current, and infer incident radiant flux using spectral responsivity. In the manufacturer-authored Model 1830-R Series Optical Power Meters User's Manual by Newport Corporation, §5.5.1 specifies a concrete sequence: connect the detector and its calibration module, select watt mode and the source wavelength, block the beam and press ZERO, then unblock it and read the display. The stored background includes dark current and ambient light present during zeroing. For narrowband radiation,
The electric current difference divided by spectral responsivity has units . For a stipulated and difference , the inferred radiant flux is ; these numbers illustrate the inference and are not reported measurements. The entire beam must hit the active area, and §5.6 calls for correct wavelength, background subtraction, and operation below detector saturation. If an optical attenuator is fitted, §5.4 requires the calibrated detector–attenuator pair and the matching meter setting.
The calibration itself must connect electric current to independently known incident power. NIST's Spectroradiometric Detector Measurements: Ultraviolet, Visible, and Near-Infrared Detectors for Spectral Power by Thomas C. Larason and others describes this chain. A cryogenic radiometer, an electrical substitution radiometer, compares temperature changes from absorbed light with those from known Joule heating (§5.2). Transfer and working detectors carry that watt scale to a spectral comparator (§5.1). A source, monochromator, focusing optics, shutter, beam splitter, and monitor photodiode illuminate a standard and test detector in turn; calibrated current-to-voltage electronics and voltmeters provide the readout (§§3.2.2–3.2.4, 4.3.1). At each wavelength, subtract blocked-beam signals and normalize each detector signal by the simultaneously sampled monitor signal. Comparison with the standard yields the test detector's spectral responsivity. NIST uses two working standards and alignment normal to the beam (§6.1.1).
Controls distinguish a smaller collected radiant flux from a faulty conversion: block and unblock the beam to check the baseline; check that its footprint fits the active area; verify the calibrated optical attenuator configuration; and test proportional response within the specified operating range. Source drift faster than monitor sampling is not removed. NIST discusses finite spectral bandwidth, stray light, temperature, and spatial response variations (§§3.1.1, 6.2, 7.2). A broadband optical spectrum requires the weighted integral in spectral radiant flux, rather than dividing by an arbitrary single spectral responsivity. These limitations explain why the meter's displayed watts need a stated collection boundary, spectral assumptions, and calibration conditions.
In NIST's 2001 comparison, the Laser-Optimized Cryogenic Radiometer held its cavity near and controlled the heat sink separately. Opening the beam reduced heater power at fixed cavity temperature; an AC bridge read the temperature. Tests used stabilized, spatially filtered lasers at , and , with horizontal input and a movable photodiode transfer detector in the cavity's optical plane. The paper contrasts this with the High Accuracy Cryogenic Radiometer's optical heating followed by two electrical heating cycles and interpolation.[ref]
The two laboratories compared calibrations of the same transfer detectors, and checked their spatial response. Alignment differences and transported dust limited that comparison; its agreement did not prove universal equivalence. Its correction tables retain window transmission, cavity radiometric absorptance, alignment, electrical readout and optical-electrical heating non-equivalence. The heat sink was controlled, but §3 does not specify its numerical setpoint: the reference in the preceding example is stipulated.[ref]
For a reproducible substitution measurement, record the beam's wavelength and entrance boundary, receiver and reference temperatures, heater terminal voltage and electric current, dark readings before and after illumination, and the settling rule. Check beam collection at the aperture, window transmission, radiometric absorptance, deposited lead heating, and sensitivity to beam position. Repeatability alone misses a stable correction error. Photometric calibration can subsequently use this radiant flux scale, but photometry still needs the appropriate spectral visual weighting; the cold receiver does not itself measure luminous flux.
Diffraction-limited resolution Created 2026-10-05 Updated 2026-10-14
Diffraction-limited resolution is a scale for distinguishing details with a specified ideal diffraction response and a specified criterion. For two equally bright, mutually incoherent optical point sources imaged through a uniformly transmitting, unobscured circular optical pupil, the Rayleigh criterion places the centre of one Airy disk at the first zero of the other. At small angles in air this separation is
Here is pupil diameter, is wavelength in air, and is the first positive zero of the order-one Bessel function of the first kind. This is the radius to the first zero, not the diameter of the central spot. Fraunhofer diffraction gives the radial peak-normalized light intensity
The removable value at zero follows from . The pupil Fourier transform reduces to a radial integral by circular symmetry, which produces the Bessel function of the first kind; its first zero supplies the factor .[ref]
In the usual scalar circular-pupil approximation for a fluorescence microscope, the corresponding object-plane Rayleigh criterion is
Here is the vacuum emission wavelength, and the object-side numerical aperture already includes the medium's refractive index. Do not divide by again. For small cone angles in air, and image-plane radius agrees with this form. The assumptions include a single wavelength, ideal optical focus, and mutually incoherent emitters. High numerical aperture can require a vector description with polarization of an electromagnetic wave and emitter orientation; confocal microscopy has its own excitation-and-detection response. The same formula therefore does not describe every microscope or illumination method.[ref]
Figure 1.
Doubling numerical aperture halves the ideal circular-pupil point-response scale at fixed wavelength
. Details.
In this original model, and numerical apertures and give first-zero radii and . Each point spread function is divided by its own peak to compare shape. The pupil axes are transverse wave vector components multiplied by , so pupil radius equals numerical aperture. A wider pupil accepts a wider range of transverse wave vectors, producing a narrower image. Increasing magnification alone enlarges the same spot and does not reduce its object-plane radius.
The Rayleigh criterion is a useful visual convention, not an absolute information barrier. For equal incoherent sources with total detected radiant flux and separation vector , the ideal image is
Below the Rayleigh criterion this still differs from ; for small , symmetry cancels the linear change and the first change is quadratic in separation. Estimating two unknown source positions is then increasingly sensitive to noise, background, relative brightness and uncertainty in the point spread function. Localizing one isolated source and recovering an arbitrary extended object are different inference tasks. Measurements that separate optical modes can also extract separation information differently from direct image light intensity measurement.[ref]
There remains a real limit for arbitrary images in this model: the optical transfer function is zero above the transmitted spatial frequency band. Its cutoff for scalar incoherent imaging is in object-plane cycles per unit length. The Nyquist–Shannon sampling theorem therefore suggests object-referred detector pixel pitch , with finer sampling providing margin. Finite detector pixels also integrate over their area, suppressing contrast; coarse sampling can cause aliasing. Finer sampling cannot alone recover spatial frequencies removed by the optics, and Fourier deconvolution amplifies noise where the optical transfer function is small. Photon shot noise, read noise, optical aberrations and defocus can all worsen practical discrimination. A useful resolution claim therefore reports the object model, criterion, wavelength, numerical aperture, sampling and signal-to-noise ratio in photon counting.
Diffraction-limited system Created 2026-10-05 Updated 2026-10-14
A diffraction-limited system has an optical response close to the ideal diffraction response for its specified optical pupil, wavelength and optical focus. Improving the optical aberrations further makes little difference to that response. This describes the optics: a poorly sampled or noisy detector can still deliver an image with much worse usable diffraction-limited resolution.
The optical pupil determines which wave amplitudes and wave phases contribute to an image point. In a scalar, paraxial approximation at the focal plane of an optical lens in air, write the pupil transmission as , after removing the ideal focusing phase. The amplitude spread function is proportional to its scaled Fourier transform:
Here are pupil coordinates, are image coordinates, is focal length, and is the wavelength in air. For a uniformly transmitting, unobscured circular optical pupil at ideal optical focus, the result is an Airy disk with surrounding rings. A blocked centre, support structures, or nonuniform transmission changes the ideal point spread function; “diffraction limited” does not specify one universal spot shape. The existing Fourier model of a Lyot coronagraph illustrates how pupil and focal masks deliberately alter this response.[ref]
Optical aberrations add pupil wave phase errors. Defocus contributes a quadratic pupil wave phase in the paraxial approximation, redistributing light intensity from the best-focused spot. The Strehl ratio compares the peak with the ideal response for the same pupil and total radiant flux. A broad optical spectrum produces a weighted sum of wavelength-dependent point spread functions; chromatic aberration can additionally change optical focus with wavelength. Thus the operating conditions belong with any claim that a system is diffraction limited.
An explicit lumped model makes the cancellation understandable. Treat the receiver as having uniform temperature , heat capacity , heater power deposited in the receiver, net parasitic input , and outward heat transfer to a reference at temperature . With incident radiant flux and radiometric absorptance , conservation of energy gives
The dark state has no admitted beam. Compare settled dark and light states, denoted and ; each has . Subtracting their balances gives
where and . At identical and , with unchanged surroundings and parasitic heating, both correction differences vanish. Thus , and . Notice the signs: extra stray thermal radiation admitted with the beam also reduces heater power, so it must be subtracted from that reduction before attributing the result to the intended beam.
Measure the heater's own terminal voltage and electric current : for steady electrical heating, , where is its electrical resistance. A supply voltage that includes wire voltage drops counts Joule heating in the leads too; only the portion deposited in the receiver belongs in this balance. Changes in that deposited lead heat belong in . Optical-electrical heating non-equivalence adds a further instrument-specific correction when the uniform-temperature model is insufficient.[ref]
Electrical substitution radiometer Created 2026-10-14 Updated 2026-10-14
An electrical substitution radiometer measures radiant flux by replacing absorbed optical power with calibrated Joule heating. At fixed temperature, feedback control holds the receiver equally warm with the beam blocked or admitted: after corrections, absorbed optical power equals the reduction in supplied electrical heating. Incident radiant flux additionally requires radiometric absorptance and entrance-path corrections. This connects radiometry to electrical standards.[ref]
Picture a small absorbing cavity connected to a colder reference block by a radiometer thermal link. A heater supplies Joule heating, a thermometer senses the receiver, and feedback control adjusts the heater. When light supplies some of the heating, the controller supplies less. The readout is the change in heater power, rather than the beam's brightness or its number of photons. NIST's institutional description gives a concrete receiver with a conical interior, absorbing coating and weak Kapton support, operated with a receiver heater and thermometer.[ref]
Figure 1. . Original functional schematic, not a drawing of a particular laboratory instrument. The shutter defines dark and illuminated states; incident radiant flux is specified at the receiver entrance. The cavity absorbs a fraction , while the remainder escapes. The reference block and receiver have distinct controlled temperatures. The thermometer signal drives feedback control, and heater voltage and electric current provide the electrical power readout. Lead heating, stray radiation and spatial heating differences require separate checks. Details.
Emissivity Created 2026-09-24 Updated 2026-10-14
Emissivity compares thermal emission from a surface with emission from an ideal blackbody at the same absolute temperature, using the same wavelength and angular averaging convention. For ordinary passive surfaces in the far field at local thermal equilibrium, the ratio lies between zero and one. A blackbody has emissivity one. Unless a spectral or directional qualification is given, the in is total hemispherical emissivity: a ratio of emitted radiant exitances, not of all outgoing radiant flux including reflected radiation.[ref]
Emissivity belongs to a specified surface state, not just a bulk material name. Coating, oxidation and surface finish can change it; wavelength, viewing direction and temperature also matter. A surface that looks white in visible light need not have low infrared emissivity. This distinction is useful when choosing a radiator coating or interpreting a radiation-based temperature measurement: a narrow-band detector needs the appropriate spectral emissivity, and its signal can include reflected surrounding radiation. The grey body and diffuse thermal emitter assumptions are separate simplifications, addressing wavelength and direction respectively.
An original declared model makes the distinction visible without substituting invented numbers for the photopic luminous efficiency function. Define a triangular weight
This is an illustrative function, not a fit or table of . Three ideal spectral lines, each carrying radiant flux , at , and have weights , and . Their model weighted outputs are respectively , and approximately . These are model calculations, not standard luminous fluxes or measured data. For mixtures of these lines the model outputs add, just as the integral adds independent spectral contributions.
Figure 1.
Equal radiant fluxes give different outputs under a declared spectral weight
. Original triangular weighting model, not CIE data. Each ideal line carries ; its drawn height represents line power, not a finite spectral density. The lower bars apply the stipulated model scale. The model demonstrates the mechanism without supplying calibration data for actual photometry. Details.
Etendue Created 2026-10-06 Updated 2026-10-14
Etendue measures how much position-and-direction space a bundle of light rays occupies. A small spot accepting a wide range of directions can have the same etendue as a large spot accepting a narrow range. This makes etendue useful for deciding whether an optical instrument can deliver an extended source's entire admitted radiant flux to a small receiver. For forward crossings of a surface, the geometrical optics definition is
where is the occupied set of surface positions and directions, is the local refractive index, is actual surface area, is solid angle, and is the angle to the forward unit normal. The cosine supplies the projected area. Opposite crossing directions must be counted separately with positive projected area, rather than cancelling them in a signed integral. [ref]
The shorthand assumes constant refractive index, a narrow nearly normal bundle, and the same admitted directions across the whole area . At larger angles, use the cosine-weighted integral; a position-dependent angular acceptance cannot generally be replaced by the product of two independent extents.
Etendue bench measurement 2026-10-14
A proposed optical bench test uses a steady illuminated diffuse patch, a relay made from two optical lens elements, interchangeable centred circular stops, and a calibrated optical power meter large enough to collect the whole output bundle. Start with small cone angles so an ordinary relay approximates the area-angle tradeoff. Measure the patch's image diameter and the accepted angular extent at both conjugate planes; the transverse magnification gives the spatial scale, but does not by itself measure etendue.
Map the local radiance with a baffled photodiode on translation and rotation stages, using two small aligned holes to select a narrow known solid angle. Keep the sampled position fixed while scanning direction, calibrate the sampling footprint and angular response, and repeat at several positions. Numerically integrate over the occupied samples, and integrate to predict the collected radiant flux. This checks the filled-cone assumption instead of inferring it from two outer dimensions.
Compare the relay without a stop and with a stop of times the illuminated diameter in the same plane. The uniform-bundle prediction is a radiant flux ratio of , with unchanged local radiance in the surviving samples. Cover the input for a dark reading, monitor source drift, repeat the open-stop reading, check detector linearity with calibrated optical attenuators, and enlarge the collecting detector or scan it to check for missed light rays. Lens losses, angular response, illumination gradients, alignment errors and diffraction can spoil the ideal prediction; their effects must be measured separately. This is a procedure to try, with predicted readouts, not purported experimental data.
Suppose an extended source fills every position of the entrance aperture with a cone of half-angle , and all these light rays must reach a one-sided planar receiver. If the receiver accepts at most a cone of half-angle , its available etendue bounds the admitted etendue:
Consequently
This original derivation combines conservation of etendue with the exact cone integral; the second inequality allows the complete output hemisphere. It bounds capacity and does not prove that a chosen shape attains the bound.
Figure 1.
Aperture clipping discards etendue; full-flux concentration requires a larger output angular range
. Left: a stop transmits of the spatial disk with unchanged directional acceptance. Right: endpoint geometry for the ideal air-to-air input-cone bound, . Interior sides are only a symbolic connection between ports, not a designed reflector or a traced ray path. Details.
For the input cone with , : a entrance cannot deliver the entire filled bundle to a circular receiver smaller than in diameter. If the output half-angle is restricted to , and the receiver diameter must be at least . For a receiver medium with model refractive index , the full-hemisphere capacity bound instead gives ; that larger value also depends on transmitting the bundle into that medium.
Attempting in the air-to-air example forces rejection of some input. For the uniform radiance already specified, even filling the entire output hemisphere gives
The maximum mean irradiance gain remains . With nonuniform radiance, rejecting a given fraction of geometric etendue need not reject the same fraction of radiant flux.
These bounds use a filled extended-source bundle in passive reversible geometrical optics, comparing the same wavelength and the same radiation channels. An ideal optical point source does not fill that four-dimensional set. Diffraction, optical coherence, or coupling a Gaussian beam into an optical fiber require a physical optics calculation; the cone bound is not a universal guarantee for a single wave mode. Likewise, optical gain or fluorescence changes the propagation assumptions.
Consider a planar circular aperture of diameter in constant refractive index . Suppose every position in its area is filled with directions inside the same rotationally symmetric cone about the unit normal, with half-angle . Using spherical coordinates, the exact etendue is
where is the appropriate side's numerical aperture. The ordinary cone solid angle is ; its cosine-weighted value is . A full forward hemisphere therefore gives , rather than . [ref]
For an original model example, choose , , and . Then
If the radiance is uniform across this filled bundle and equals , its radiant flux is . Neither the geometry nor the chosen radiance is an experimental measurement.