Radiometry measures the energy and power carried by electromagnetic radiation, including light. It asks how much radiation a source supplies, where it travels, and how much reaches a receiving surface. The measurements are physical rather than weighted by the sensitivity of the human eye: equal radiant fluxes at different wavelengths need not look equally bright. [ref].
The five quantities below answer different questions about the same radiation. The International System of Units makes the distinctions visible: a watt is a joule per second, while a steradian measures solid angle. [ref].
QuantityWhat is resolved?Units
Radiant flux Total radiation power in the specified beam or collection
Radiant intensity Power per outgoing solid angle
Radiance Power per projected area and per solid angle
Irradiance Incident power per receiving area
Radiant exitance Outward emitted power per emitting area
Resolving wavelength or frequency adds a further “per unit interval”, as in spectral radiance. The notation is consistent with NIST's table of spectral quantities. In particular, radiant flux is power, whereas the existing astronomical radiative flux is power per area. [ref].
This bookkeeping makes an optical camera's collected signal calculable from a source's radiance and the geometry of the receiving aperture. It also lets radiation measurements from different instruments be compared. For example, NIST describes separate calibrations of spectral radiance and spectral irradiance for instruments used to observe Earth. [ref].
An integrating sphere is an optical cavity with diffusely reflecting interior walls and ports for illumination, samples or detectors. Repeated wall reflections mix the incident radiant flux, reducing sensitivity to where it first strikes. Baffles prevent a receiver from directly viewing an unwanted source or illuminated patch; port size and wall reflectance remain part of the response model.[ref]
An original encounter model illustrates the effect of openings. Suppose a well-mixed reflection retains fraction and fraction of the reflected light escapes through ports before the next wall encounter. The integrating-sphere port-loss factor combines with wall reflectance to give a survival fraction . If the first wall encounter carries energy , successive encounters carry , so their summed incident energy is .
With stipulated and , this sum is . Enlarging the openings to reduces it to . These are repeated encounters with the same initially supplied energy, not optical gain: absorption and escape together still account for that original energy. The example counts incident wall encounters from the first one and does not assert a calibrated detector multiplier.
An actual sphere measurement compares its detector signal with a calibrated input or reference. Coating wavelength dependence, ports, sample substitution and temporal response can affect the conversion. The primary guide discusses reflectance/transmittance arrangements and their measurement geometry.[ref] An integrating sphere is therefore useful apparatus, rather than a guarantee that every outgoing component has been measured without correction.
The integrating-sphere port-loss factor is the fraction of a well-mixed reflected field that next encounters the wall rather than an absorbing opening, where is total port area divided by the internal spherical area. It is a geometric retention factor, not wall reflectance. With uniform wall reflectance , successive wall encounters retain fraction . The primary sphere derivation explicitly separates the port fraction from reflectance and generalizes to nonzero port reflectances.[ref]
An original energy-accounting example starts with energy incident on the wall after the input beam's first impact. At each encounter fraction is absorbed; fraction reflects and escapes; fraction reaches the wall again. Summing the geometric series gives
The two fractions sum to one. For stipulated and , about is ultimately absorbed and escapes. Thus a four-percent port fraction does not mean that only four percent ever exits: repeated reflections give repeated opportunities. This is the integrating-sphere escape probability in the stated ideal encounter model.
The input convention matters: these fractions start at a wall encounter and omit any input beam that escapes without striking that wall. Real ports can contain reflective samples or detectors, and baffles change direct paths. A sphere experiment can vary an aperture while monitoring a stable injected radiant flux, but its response must include those surfaces and the receiver field of view. The factor alone is not a detector calibration or a universal collection efficiency.
The integrating-sphere escape probability is the chance that a photon in a specified integrating sphere model eventually leaves through a port rather than being absorbed by the wall. It depends on both the port area fraction and wall reflectance , as well as where the model begins. In the ideal uniformly diffuse model with nonreflecting ports, the integrating-sphere port-loss factor is and the survival probability between successive wall encounters is .[ref]
Start immediately before a wall encounter. The photon is absorbed there with probability , reflects and escapes before the next wall encounter with probability , or returns to the wall with probability . These satisfy . Under the same well-mixed encounter rule each time, eventual escape at encounter has probability . Summing the geometric series gives
Similarly, and . These are an original probability derivation of the guide's repeated-reflection bookkeeping, not an additional source of optical energy.
Figure 1.
Ideal photon accounting from the first wall encounter: eventual escape versus port fraction, and cumulative escape, absorption and survival for a stated reflectance and port fraction
. Details.
For an original numerical example, and give , so
Although only four percent of the spherical area is open, almost half the initial photon ensemble eventually exits: surviving photons get repeated opportunities. After completed encounters, the escaped fraction is , the absorbed fraction is , and the fraction still inside is . The three fractions sum to one for every .
The stopping encounter has a geometric distribution with termination probability . Its expected count is , about 12.76 in this example. This counts wall encounters; it does not specify elapsed time without a model of path lengths and propagation.
Boundary cases clarify the assumptions. With and , every photon is eventually absorbed. With and , every photon eventually escapes. If both and , the ideal photon never terminates and the formula's is inapplicable. Starting after a successful first reflection instead would also give a different conditional escape probability; the starting point must accompany the result.
A measurement can vary a known aperture while injecting a stable radiant flux that first strikes the wall. A monitored detector then tests the apparatus response against a model including its viewing geometry. A single detector signal is not automatically the total energy escaping through all ports. Real coatings, reflective port fixtures and direct paths require corrections; baffles prevent the receiver from directly viewing an unusually bright first-illumination patch.[ref] The probability above is therefore a useful ideal-model prediction, not a universal detector efficiency.
Spherical irradiance counts incident radiance from all directions without selecting a receiving-plane normal. Using the projected-area convention specified in the CIE entry's note2,
Here is an element of solid angle. An ideal small sphere of radius intercepts radiant flux . The denominator is its diametrical projected area, not its full surface area.[ref]
For an original isotropic radiance field example, take in every direction. Then . A one-sided plane instead receives
The factor four follows from the different angular geometries; it is not a unit conversion. Averaging the sphere's intercepted power over its actual surface also gives , rather than the projected-area-normalized quantity above.
An all-direction receiver must have a characterized angular response. A single flat irradiance detector inherently samples a hemisphere with projected-area weighting, so rotating it or enclosing it in a diffuser does not supply an all-direction value without an appropriate response model and measurement calibration. Report the angular and area conventions with the result; equal units do not make irradiance and spherical irradiance interchangeable.
An isotropic radiance field has the same radiance in every direction at the specified point: . Angular isotropy is a local property; it does not by itself assert that is the same at every spatial position. Integrating this constant field gives the orientation-independent one-sided irradiance . The spherical irradiance article derives the corresponding all-direction value using its projected-area convention.[ref]
An original counterexample shows why a few equal detector readings do not establish isotropy. Send six ideal narrow beams toward a point along the positive and negative Cartesian axes. Give every beam a normal-incidence irradiance . A one-sided planar receiver with unit normal then records
The three axis-aligned receiver orientations all give . However, a normal along gives . Three mutually perpendicular measurements therefore agree even though the idealized field is strongly directional. Finite narrow beams approximate this construction.
An angular isotropy test with planar irradiance measurements must sample enough orientations to test its stated angular model. A collimated light source and a rotating receiver can check angular response before such a test. Detector-area projection and the instrument's own angular sensitivity must be distinguished from variation in the incident field.
An angular isotropy test with planar irradiance measurements rotates a characterized receiver to test whether its readings agree with a specified model of an isotropic radiance field. A one-sided ideal cosine receiver measures . Constant radiance gives the same for every normal. Instrument angular response needs characterization; the primary guide describes experimental correction of cosine receptors.[ref]
An original restricted-model example makes the inference quantitative. Assume a dipole anisotropy of a radiance field,
Hemisphere integration gives . For , and along the vertical axis, upward/downward-facing receivers give and . Their difference divided by their sum is , implying within this chosen model.
Use the same receiver position, background treatment and a stable source monitor while changing orientation. Gain drift or moving into a different spatial field can otherwise imitate an angular effect. A finite set of readings tests the assumed angular family; it does not prove unrestricted isotropy. The six-beam counterexample in isotropic radiance field shows why a few equal axis readings can miss other directional structure.
A dipole anisotropy of a radiance field is a directional first-order departure from a constant radiance:
Here is a unit viewing direction, and the bound ensures nonnegative radiance. Writing with unit gives the amplitude/direction convention in the title. The angular isotropy test with planar irradiance measurements derives its receiver response.
An original inversion uses opposite receiver orientations. Suppose measured irradiances are , , and all four readings equal . The pair means give . Since
the fitted vector is . Agreement of the three pair sums is an additional check on this restricted model and a stable measurement chain.
The first angular moment of a radiance field is . By contrast, integrating over all directions gives , independent of . Thus this example's projected-area-normalized spherical irradiance is , exactly the value for an isotropic field with the same . One all-direction scalar cannot determine its dipole.[ref] Receiver angular response must also be characterized rather than assumed ideal.
The first angular moment of a radiance field is the vector
with units for frequency-integrated radiance. It records a directional imbalance. Here is the viewing direction toward the arriving light, as in dipole anisotropy of a radiance field; using propagation directions instead reverses the vector. With that convention change, this is the bolometric vector form of the radiative flux, an existing radiation-field moment.
Opposite ideal planar receivers measure this moment without assuming a pure dipole. Since , the cosine-response irradiance formula gives
Three orthogonal receiver pairs therefore determine the three components. For original differences , the moment has those components and magnitude . The derivation requires the same spatial field, stable gains and known angular response. The primary optical guide describes cosine-receptor characterization rather than assuming it perfect.[ref]
A zero first moment does not establish an isotropic radiance field. For example, two equal oppositely directed collimated beams have cancelling vector moments while remaining strongly directional. Conversely, any nonzero first moment rules out isotropy. The scalar all-direction integral bounds the moment by for nonnegative radiance, by the triangle inequality and .
Within the restricted dipole anisotropy of a radiance field model, determines its dipole vector. More general angular structure is not reconstructed by these three numbers. Opposed receivers reveal the first moment, not the entire directional distribution.
Radiant energy is the amount of energy emitted, transferred or received as electromagnetic radiation. It is measured in joules. For the specified beam or collection of rays crossing a boundary,
where radiant flux is radiation power. The receiving geometry and time interval are part of the statement; dividing by a receiving area produces radiant exposure, rather than another total energy.[ref]
For an original passive-optic example, stipulate incident during an interval, with no remaining change of stored energy afterward. Suppose is transmitted, reflected and absorbed. Their sum is the incoming . A detector collecting only the transmitted path receives , even though the source supplied more. This radiometric energy balance specifies the collection boundary instead of equating every energy readout in the apparatus.
A thermal detector converts absorbed radiation into an observable temperature response; a calibrated model relates that response to received energy. A documented NIST arrangement uses a slow thermal reference and calibrated beam splitting to establish pulse-energy measurements.[ref] Absorbed energy, incident radiant energy and energy in an uncollected branch must remain distinct in that calibration.
Two sources can deliver the same radiant energy with different radiant flux histories or spectra. Their total energies agree only for the specified integration and collection; this alone does not determine peak power, radiant exposure at a point or detector response.
A radiometric energy balance accounts for radiant energy crossing the specified measurement boundary during a specified interval. For a passive optic, suppose the relevant transient has finished, no electromagnetic energy remains stored, and no additional energy source is present. Incident radiation is partitioned into all outgoing radiation and energy transferred to matter. Resolving outgoing paths gives
The channels must be disjoint: a scattering term cannot include energy already counted by a reflection or transmission collector. The definition of radiant energy concerns radiation emitted, transferred or received, so the location and collection geometry belong in each term.[ref]
For an original example, inject and measure in the transmitted path plus in the specular reflection. Calling the missing absorbed is premature. If a separate collector finds of diffuse outgoing radiation outside those channels, the inferred absorbed energy is only . The uncollected scattering in a radiometric energy balance would otherwise be misidentified as optical absorption.
A physical check compares calibrated incident and outgoing energy readouts while controlling apertures, backgrounds and the observation window. The scattered component may need a different collection geometry from the specular beam. Energy absorbed by matter can remain stored or later leave as heat or radiation; a more general control-volume balance must explicitly include storage, other heat transfer and work. It must not count absorbed energy twice by also treating the same material-energy increase as an independent loss.
Uncollected scattering in a radiometric energy balance is outgoing scattered radiation that falls outside the measured channels. Assigning every missing joule to optical absorption then overestimates the absorbed energy. The radiometric energy balance must count disjoint transmitted, reflected, scattered and absorbed terms for the same interval.
For an original collection model, stipulate incident, transmitted and specularly reflected. A separate scattered-light receiver collects . If its calibrated capture fraction is , the scattered energy is , leaving absorbed. If all that is known is , scattering can range from to and absorption from to . One receiver reading cannot determine both the total scattering and its capture fraction.
The fraction is an energy fraction, not automatically the receiver's fraction of solid angle. Converting geometrical coverage into an energy fraction also needs the scattering distribution.
An integrating sphere provides broad angular collection through repeated diffuse reflection. Actual reflectance/transmittance arrangements depend on port geometry, baffles and whether the specular component is included. The primary guide describes excluding that component through a port and using baffles to prevent direct viewing of the illuminated sample.[ref] The apparatus therefore needs its own response calibration; calling a receiver integrating does not establish perfect collection.
Radiant exposure measures the radiant energy received per unit surface area during a specified interval. At a fixed surface point , it is the time integral of incident irradiance :
The area belongs to the receiving surface: its orientation and location matter. An irradiance in specifies a rate, while radiant exposure in specifies the accumulated arrival of energy.[ref]
For a uniform rectangular pulse, , with constant irradiance and duration . Stipulate one pulse at for , and another at for . Both deliver , but their peak irradiances differ by a factor of four. The two radiant exposures agree only after each complete pulse has arrived. A shorter observation window can intercept different fractions of them, and a nonlinear receiver can respond differently even to their complete pulses.
Figure 1.
Original rectangular-pulse example: different irradiance histories accumulate the same radiant exposure.
Details.
Integrating over a receiving patch gives its incident radiant energy:
Here is the spatially averaged radiant exposure, rather than necessarily the local maximum. Uniform illumination is the special case where this spatially averaged radiant exposure equals the local value everywhere on the patch. In the rectangular-pulse example, a uniformly illuminated patch receives .
For an original spatial example, consider a circular Gaussian beam at a fixed transverse plane, with constant Gaussian beam radius throughout the pulse. Let be its total radiant power and its laser pulse energy. Integrating its transverse irradiance in time gives the radiant exposure of a Gaussian beam:
The normalization follows by integrating from to . The disk of radius contains only , so its actual spatially averaged radiant exposure is , not . With stipulated and , the peak is , while the average inside that disk is . State the Gaussian beam radius convention and the receiving area with any reported value.
An energy readout alone therefore does not specify a surface's radiant exposure. In an ideal linear model for pulse energy measurement with a photodiode, dark-subtracted photocurrent has constant spectral responsivity at the chosen wavelength. Integrating the electric current gives signal electric charge . If a known patch of area is uniformly illuminated and all of its incident energy is collected, then
As a separate stipulated example, and correspond to . Uniform illumination over gives . Background subtraction, collection geometry, detector linearity and an integration window covering the full response are part of this measurement model. Continuous-wave responsivity alone does not establish linearity for a short pulse: silicon-photodiode experiments have observed pulse-dependent saturation.[ref]
A historical NIST measurement calibration separates these operations experimentally. A modulator produces pulses from a continuous-wave laser; a calibrated beam splitter sends one beam to a slow thermal reference and another to the pulse detector. The reference records the accumulated energy, while the pulse repetition rate and injection duration determine the mean energy per pulse. The detector's integrating electronics provide a pulse-energy readout. Converting such a readout to radiant exposure additionally requires the illuminated area and its spatial distribution.[ref]
The beam-use term fluence denotes the same time integral for a directed beam normal to the chosen surface. For light arriving from many directions, specify the angular geometry: planar irradiance and spherical irradiance are different quantities, so a value defined using one cannot simply be substituted for the other.[ref]
The radiant exposure of a Gaussian beam is its time-integrated transverse irradiance. At a fixed plane normal to a circular Gaussian beam, suppose the Gaussian beam radius is unchanged during a pulse and denotes the radius where irradiance is of the on-axis value. With total laser pulse energy ,
The primary beam account specifies this radius convention and the corresponding irradiance normalization; the radiant exposure parent derives its time integral.[ref]
An original aperture example asks how much of that energy a finite receiver collects. Integrating over a centred disk of radius gives the encircled radiant energy of a Gaussian beam:
For stipulated , and , the receiver collects only percent, or . Its spatially averaged radiant exposure is about , compared with on-axis . Dividing the total by this receiver's area would count energy that missed it.
Figure 1.
Local Gaussian radiant exposure and cumulative energy capture describe different functions of radius.
Details.
To collect a chosen fraction under this ideal model, the centred aperture needs . For95percent, . A possible experimental check measures integrated received energy through several known apertures and compares their ratios. Aperture centring, detector linearity and any profile change during the pulse affect that comparison. A time-varying radius must remain inside the time integral rather than being replaced by an unspecified average radius.
The encircled radiant energy of a Gaussian beam is the radiant energy inside a centred circular receiver at a specified transverse plane. For fixed Gaussian beam radius and total laser pulse energy ,
The radiant exposure of a Gaussian beam contains the radial integration and aperture-capture plot. Its is the irradiance radius, as specified in the primary beam account.[ref]
An original annular example distinguishes energy near an axis from energy between two radii. Subtracting two encircled values gives
Choose , , and . The annulus receives , or 47.12 percent of the full beam energy. A bright central point does not imply that most energy lies in an arbitrarily small disk around it.
Indeed, the radial radiant-energy density of a Gaussian beam is , where is local radiant exposure. For this profile it is largest at , even though is largest at zero radius. Increasing a centred aperture and comparing integrated detector readings can test the cumulative prediction. Detector linearity, aperture alignment and the finite collection boundary must be controlled; a displaced aperture is not described by the centred formula.
The radial radiant-energy density of a Gaussian beam gives energy per increment of radius, rather than per unit surface area. For local radiant exposure and encircled radiant energy of a Gaussian beam ,
Its units are , while has units . The primary Gaussian profile uses as the irradiance radius.[ref]
For an original narrow-annulus comparison, take and . The central disk from zero to receives about . The annulus from to receives about . Both span the same radial width, but the outer annulus has much more area. Equal radial width is not equal receiving area.
The shell density is maximal at and vanishes at , despite the local exposure being largest on axis. Dividing by gives a probability density function over nonnegative radius: it is a Rayleigh distribution with scale . This is an energy-weighted mathematical representation, not an additional photon-counting assumption. Differences between successive centred-aperture energy measurements estimate shell energies; dividing by their radial separation approximates when that separation is sufficiently small.
Spatially averaged radiant exposure is the received radiant energy divided by the specified receiving area. For a patch and local radiant exposure ,
Both local and averaged values have units , but the average need not equal the local maximum. The radiant exposure definition uses incident energy and the receiving surface's area.[ref]
For an original unequal-area example, let one region receive a uniform , and a neighbouring region receive . They receive and respectively. The average over the combined patch is therefore
The unweighted average of the two listed exposure values would be , which is wrong for these unequal areas. The area weighting of radiant exposure gives the larger region three times the influence. The actual peak remains in the stipulated piecewise-uniform model.
A receiver integrating all incident energy over the complete patch can determine ; division by its known collecting area then gives the average. That measurement alone cannot identify the peak or reconstruct the spatial distribution. Subdivision with a characterized spatial response supplies additional information. For a finite aperture intercepting a Gaussian beam, use energy actually entering the aperture, as calculated in radiant exposure of a Gaussian beam, rather than the total energy of the untruncated beam.
Area weighting of radiant exposure combines patch-average exposures in proportion to the receiving areas they represent. For disjoint patches with areas and mean radiant exposures , the coefficients satisfy , and the combined spatially averaged radiant exposure is . This follows by adding the received energies , rather than averaging a list of values without its geometry.[ref]
An original coordinate example explains a calibration issue in image-based measurements. Let a rectangular receiving strip have length and constant width. Stipulate for . Suppose a calibrated image coordinate maps to physical position . Uniform sampling in is therefore nonuniform in physical area.
The physical area average is
An unweighted average over increasingly dense, uniformly spaced samples would instead converge to . The factor is the change of variables formula's area correction for the chosen mapping; the constant strip width and cancel in the normalized average.
Thus a Jacobian area correction for radiant-exposure maps can matter even if every local exposure value is correct. An optical camera measurement needs its spatial calibration and the receiving-surface map, not just pixel values. Overlapping patches must not be counted as disjoint areas, and local point samples need an explicit quadrature model before they can stand for patch averages.
A Jacobian area correction for radiant-exposure maps converts a coordinate-space integral into one over the physical receiving surface. For a one-to-one planar calibration map ,
The Jacobian determinant supplies physical area per coordinate-area increment. This change of variables formula preserves the radiant exposure definition as incident energy per receiving area.[ref]
For an original two-dimensional example, let and map , , with and . Then . Stipulate with . The physical receiving area is , and
Its spatially averaged radiant exposure is . Uniformly averaging the exposure values over without the determinant gives only .
The correction applies to exposure densities represented in distorted coordinates. If each detector sample already reports energy integrated over its physical patch, summing those calibrated energies requires no second multiplication by patch area. Otherwise the area is counted twice. An optical camera reduction must specify whether its values represent energy, irradiance, exposure or a further processed signal.
Ocean optics relates measured light in seawater to optical absorption, scattering of light and the underwater angular light field. Water, dissolved substances and suspended particles all contribute, so ocean color is not determined by one pigment concentration alone.
A transmission measurement through a known water path constrains beam attenuation; detectors at selected angles measure scattered light; an upward-looking instrument measures downwelling irradiance. These observables answer different questions. In particular, a diffuse attenuation coefficient includes angular redistribution and need not equal the material's absorption coefficient. Comparing several measurements helps separate mechanisms that one emerging optical spectrum cannot uniquely determine.
The illuminated region of a water body. In ecological usage its photosynthetically usable part is often identified with the euphotic zone; the operational light threshold must be stated.
The upper water interval with sufficient light for substantial photosynthesis. A common operational lower boundary is the euphotic depth at 1% of surface photosynthetically active radiation.
The depth of a chosen light threshold, commonly 1% of just-below-surface photosynthetically active radiation. It depends on spectral attenuation and is not a universal species-specific compensation depth.
The spectral distribution of light emerging from a water body, determined by absorption and scattering by water, dissolved material, particles and sometimes the bottom. It supports remote inference of biological and optical properties.
The logarithmic rate at which downwelling spectral irradiance decreases with depth. It depends on absorption, scattering and the angular light field, rather than equaling the absorption coefficient.
Inference of chlorophyll a concentration from measured optical signals. Simple blue/green ratios rely on assumptions about covarying absorbers and scatterers; coastal mixtures can violate those assumptions.
The rate per unit path length at which light is scattered into the backward hemisphere. It influences water-leaving radiance and must be distinguished from the absorption coefficient.
The ratio of water-leaving radiance to incident downwelling irradiance just above the surface. It depends on both absorption and backscattering and has units of inverse steradian.
An optically defined non-phytoplankton particle category, including detritus and suspended mineral material. Its absorption is often strongest in the blue; scattering can also strongly affect remote-sensing reflectance.
The light-absorbing fraction of dissolved organic material. Its visible absorption commonly decreases approximately exponentially from blue to red, and can confound chlorophyll retrieval.
Solar radiant power incident per unit area. Horizontal, beam-normal and tilted-plane irradiances are different quantities: for a direct beam on a horizontal plane, , where is solar elevation.
Inferring properties of a distant object from measured signals, often electromagnetic radiation. Spatial sampling, spectral information and observation cadence must jointly resolve the physical process of interest. Received radiance alone need not uniquely separate temperature, emissivity and atmospheric attenuation.
Range measurement using transmitted laser light and its returned signal. For a pulse traveling a round trip in air, the elementary range is , where is the propagation speed and the measured travel time. Sensor position, pointing and time synchronization place returns in a three-dimensional point cloud. Scanning lidar can record multiple returns from vegetation and the ground; a return is an observation of a reflecting surface, not automatically bare-earth elevation.
Lidar acquired from an aircraft with surveyed trajectory and orientation. Ground-return classification removes canopy and structure returns before constructing a bare-ground digital elevation model. Penetration through forest is sampling through canopy gaps, not unrestricted transmission through leaves. Areas with few or no ground returns require uncertainty assessment rather than treating interpolated heights as observations.[ref]
Recovery of object positions and shape from photographs with overlapping views. Known or estimated camera geometry and matched image features constrain three-dimensional point positions. A metric reconstruction requires scale and a coordinate reference; image pixel size is not automatically the positional accuracy of the reconstructed surface. Stereo photogrammetry and structure-from-motion photogrammetry use related geometry with different acquisition and camera-estimation strategies.
An identifiable image feature or target with independently surveyed coordinates, used to georeference and constrain a photogrammetry model. A check point is withheld from the fit to assess reconstruction accuracy. Distribution across the site, accurate survey and consistent height datums matter as well as the number of points.
A photogrammetry workflow jointly estimating camera geometry and scene structure from many overlapping images, commonly followed by dense surface reconstruction. Ground control points or accurately surveyed camera positions establish scale and georeferencing. Independent check points test accuracy rather than participating in the fit. A fine image ground-sampling interval does not alone establish equal vertical accuracy.
Three-dimensional reconstruction using two or more overlapping photographs from different viewing positions. Corresponding image points define viewing directions whose intersection estimates the surface position. Surveyed camera positions and orientations, camera calibration and ground control points establish the coordinate geometry. Ordinary optical stereo models the visible surface, which can be forest canopy rather than bare ground.
Imaging in many narrow, usually adjacent wavelength bands. Relative to broad-band multispectral imaging, it can resolve narrower mineral absorption features in spectral reflectance, helping distinguish surface lithologies, at the cost of data volume and often reduced signal per band.
Atmospheric correction estimates surface-related optical signals from observations that also contain atmospheric absorption and scattering. A satellite receives radiation scattered toward it along the path as well as radiation transmitted from the surface, so correcting only for a multiplicative loss is generally insufficient.
For ocean observations, the retrieval must account for atmospheric path contributions, transmission and relevant surface effects before estimating water-leaving radiance and remote-sensing reflectance. Its assumptions are tested against reference observations or independent atmospheric information. Cloud contamination and an incorrect scattering model can create false surface features, even when the detector calibration is accurate.[ref]
The Geostationary Operational Environmental Satellite series, used for frequent weather observations from geostationary orbits.
A European meteorological satellite series including geostationary orbit missions for repeated regional weather observations.
A European optical multispectral imaging mission using Sun-synchronous orbits for repeated observations of land and coastal areas.
A series of Earth-observation missions using repeated optical and multispectral imaging from near-polar Sun-synchronous orbits.
Multispectral imaging records spatial images in several selected wavelength bands. An optical filter array, separate filtered optical paths or a tunable selection mechanism lets different detector channels sample different portions of the optical spectrum.
Comparing red and near-infrared spectral reflectance can distinguish vegetation-like responses from some other surfaces, but measured channel values also depend on illumination, atmosphere and sensor response. The bands must sample corresponding locations: motion between sequential exposures can create apparent spectral differences at edges. More bands add information only when their calibration, spatial sampling and signal-to-noise ratio support the intended comparison.
An image formed by dividing corresponding calibrated pixels in two spectral bands. If their signals have a common multiplicative factor, and , their ratio is and does not depend on . This explains suppression of some common illumination effects and enhancement of spectral contrasts. Additive atmospheric radiance and small denominators prevent exact cancellation and can amplify errors. Normalized difference vegetation index is a related normalized spectral contrast.
The normalized contrast of red and near-infrared reflectances. Large positive values indicate a vegetation-like spectrum, but soil, atmosphere, shadows and canopy saturation affect its interpretation.
A displayed image assigning measured bands to colour channels that differ from ordinary visual perception. Assigning near-infrared to red is a common way to highlight vegetation.
The steep increase of healthy green vegetation reflectance between red absorption and the high near-infrared scattering plateau, typically around 0.68–0.75 micrometres.
Comparison of coherent radar phases from repeated observations to infer relative line-of-sight displacement. A complete deformation fringe represents half a radar wavelength after other phase contributions have been removed.
An image of the relative radar phase between co-registered coherent observations. A displacement changes the two-way path length, giving phase change proportional to , with sign set by the adopted range convention. A full wrapped phase cycle therefore corresponds to half a radar wavelength of line-of-sight displacement. Orbital geometry, topography, atmospheric delay and scattering changes must be separated from deformation; a fringe is not uniquely an elevation contour or an earthquake displacement.[ref]
A normalized measure of consistency of complex radar returns over a neighborhood. Low coherence makes interferometric phase unreliable and can arise from vegetation, surface changes, viewing differences or extreme displacement gradients.
The component of a displacement vector along a specified sensor–target viewing direction. Its sign must state whether motion toward or away from the sensor is positive.
The phase difference of complex radar returns. It includes deformation, topography, orbital geometry and propagation contributions; the displayed wrapped phase is defined modulo .
The fraction of transmitted light scattered sufficiently far from the forward direction under a specified measurement geometry. A transparent electrode can have high total transmittance yet blur an image if scattering is strong. State the collection angles and wavelength when comparing haze measurements.
The photon flux incident from all propagation directions, resolved by wavelength when needed for photodissociation. It is distinct from the net radiative flux through a horizontal surface; scattered and diffuse photons can contribute even when their net vertical flux cancels.
For a beam at a specified surface, fluence is the time-integrated incident light intensity: , with units of energy per area. It records how much energy arrived during an exposure rather than the instantaneous rate of delivery.
For a constant rectangular pulse, . Two pulses can therefore have equal fluence and different peak intensities if their durations differ. This matters in nonlinear optics, where the response can depend strongly on instantaneous intensity, and in comparing exposure protocols. Photon fluence instead counts incident photons per area; converting it to energy fluence requires the photon energies.
Energy carried by incident photons per unit area. For monoenergetic photons, , where is photon fluence. With charged-particle equilibrium, relates it to absorbed dose.
The number of photons incident per unit area in a specified geometry. It is distinct from a rate per unit time. For a monoenergetic beam, photon energy fluence is .
A radiometer measures electromagnetic radiation through its received power. A radio radiometer can express that power as a noise temperature, allowing an unknown source to be compared with calibrated reference temperatures.
For a stable linear radiometer, known cold and hot radiances give . Put and . Then ; all three measured voltages contribute to the retrieved uncertainty.
A noise temperature expresses received or internally added noise power on an equivalent temperature scale. For one matched receiving channel in the classical thermal limit, an ideal rectangular bandwidth gives , with Boltzmann constant . An equivalent noise temperature need not equal a component's physical temperature.
The system noise temperature includes all noise contributions referred to a specified receiver input. In a simple additive model with negligible intervening losses, , where is the antenna temperature and the receiver noise temperature.
The receiver noise temperature represents noise added by the receiver as an equivalent noise temperature referred to its input. Separating it from the antenna temperature prevents internal receiver noise from being mistaken for radiation from the sky.
For a stable radiometer with affine output , let be the fixed response coefficient and the receiver noise temperature. Two reference loads with known equivalent input noise temperatures give outputs and . Subtracting their outputs eliminates ; dividing source and reference differences eliminates :
This two-load radiometer calibration assumes unchanged response and receiver noise temperature between readings, with the loads and source referred to the same input. It also eliminates an additional constant output offset. Physical load temperatures must first be converted to the applicable equivalent input noise temperatures when the classical thermal approximation fails. The Penzias-Wilson microwave background experiment gives an original worked example.
The fraction of incident radiant flux returned by reflection, for specified wavelength, angle of incidence and collection directions.
A function relating reflected radiance in one direction to incident irradiance from another direction at a surface location. A local nonemissive, nonfluorescent optical reflection model integrates over incident solid angle to obtain outgoing radiance. Transmission, wavelength conversion and nonlocal transport need additional models.
The ratio of reflected to incident radiant flux as a function of wavelength, under specified geometrical and illumination conditions. Unlike a perceived colour, spectral reflectance describes a physical response; perceived colour also depends on the incident spectrum and the observer.
The transfer of energy from electromagnetic radiation to matter. Optical reflection redirects the incident electromagnetic radiation, and transmission lets it pass through; absorption transfers some of its energy to the material instead.
Radiant flux is the power carried by electromagnetic radiation: radiation energy transferred per unit time, measured in watts, . Specify what is counted: all radiation emitted by a source, radiation within one beam, or radiation intercepted by a photodetector. Writing for the cumulative energy crossing the specified boundary gives
The first expression is an instantaneous derivative; the second is an average over the stated time interval. If arrives during , the mean radiant flux is . The photodetector's absorbed power equals this incident radiant flux only if it absorbs all of the incident radiation.
Keeping radiant flux fixed while widening a beam reduces its irradiance, the incident power per receiving area. Radiance additionally resolves the propagation direction and has units ; an optical camera can collect different radiant fluxes from sources with the same radiance but different apparent solid angles. Luminous flux, measured in lumens, weights the optical spectrum by the human eye's standardized response instead of counting energy equally at every wavelength. Equal radiant fluxes need not give equal luminous fluxes.[ref]
Radiant power also differs from the optical power of an optical lens, which is reciprocal focal length in dioptres. Likewise, astronomical radiative flux is power per area. Stating the units prevents these shared words from hiding different physical quantities.
In geometrical optics, suppose radiation has a nonnegative radiance whose directional contributions add as power. Here is the actual propagation unit vector, is a solid angle element, and the collecting oriented surface has chosen unit normal . Assume the following integrals exist. The outward and inward radiant fluxes are
Both quantities are nonnegative; their difference is the signed net radiant flux. The dot product supplies the cosine of the angle with the unit normal, hence the projected area. For incoming radiation the outward unit normal gives a negative dot product; the minus sign makes the collected power positive. Measuring the incoming angle from a source-facing unit normal instead gives the familiar positive . The units check is .
Equivalently, the incoming surface integral is with local irradiance ; the emitted part of is with radiant exitance . For a small flat patch and a narrow accepted cone, nearly constant radiance and angle give . This approximation requires uniformity across the patch and cone. Direction-independent outgoing radiance over a whole hemisphere gives the different exact result , by Lambert's cosine law and the spherical coordinates calculation in radiant exitance. Replacing the cosine-weighted integral by the hemisphere's solid angle would double the answer.[ref]
These radiance formulas presume a description in additive directional power; they do not reconstruct arbitrary coherent wave interference from separate ray contributions. For general electromagnetic fields, the signed instantaneous power crossing an oriented surface is , using the Poynting vector ; optical measurements commonly average over many wave periods. A zero net radiant flux can conceal equal nonzero incoming and outgoing radiant fluxes.
Consider an ideal parallel circular beam with uniform irradiance inside radius , zero outside, and total radiant flux . A centred circular collector of radius , perpendicular to the light rays, intercepts
For and , and the collected radiant flux is . Expanding the beam to while keeping fixed divides irradiance and the same collector's radiant flux by four: and . A collector covering either entire beam still receives .
Tilting a flat collector of actual area by an angle to the beam direction gives if its entire projected area remains inside the uniform beam. At the small collector's radiant flux halves. A collector large enough to intercept the whole beam after tilting still receives : the footprint on its surface grows as and cancels the irradiance factor. This model ignores diffraction, beam-edge structure, and changes in absorption with incidence angle; it counts incident rather than absorbed power.
Figure 1.
Fixed radiant flux, different beam widths and collecting projected areas
. Original ideal geometry, not measurements. The beam cross-sections use the same centimetre scale and total radiant flux of ; both collectors have radius . The side view shows a collector's cross-section at : its projection perpendicular to the light rays has half the width, with depth unchanged. The stated half-power result requires the projected collector to stay inside the uniform beam. Details.
Spectral radiant flux resolves radiant flux by wavelength or frequency:
Its units are per metre of wavelength or per hertz of frequency. A density quoted per nanometre must be integrated with wavelength intervals in nanometres; its numerical value is times the per-metre density. The frequency and wavelength spectral radiance conversion applies equally to spectral radiant flux, through the change of variables formula:
with the speed of light in vacuum and expressed per metre. The Jacobian determinant preserves integrated power rather than the height or location of an optical spectrum's peak.
For two explicitly synthetic optical spectra, let and quote the following densities in :
The triangle under and the rectangle under both have area : . Their band radiant fluxes differ: – contains of , while – contains of . These are specified functions, not measured source spectra.
Figure 1.
Equal total radiant flux can hide different band radiant fluxes and detector signals
. Original synthetic optical spectra with exact total radiant flux each. Darker shading marks the stated 100 nm bands. The lower panel uses a stipulated linear spectral responsivity ; integrating it against the two spectral radiant fluxes gives dark-subtracted electric currents and . The response is illustrative and is not a calibration curve for a real photodiode. Details.
The dark-subtracted electric current of a linear photodiode is
using its spectral responsivity. The figure's stipulated gives and despite equal total radiant flux. Symmetry places 's mean wavelength at and 's at ; a linear averages to its value at that mean. A single electric current therefore cannot determine an unknown broadband radiant flux without additional spectral information or a sufficiently flat calibrated response.
An optical power meter makes the definition operational: collect a specified beam on a calibrated photodiode, measure its electric current, and infer incident radiant flux using spectral responsivity. In the manufacturer-authored Model 1830-R Series Optical Power Meters User's Manual by Newport Corporation, §5.5.1 specifies a concrete sequence: connect the detector and its calibration module, select watt mode and the source wavelength, block the beam and press ZERO, then unblock it and read the display. The stored background includes dark current and ambient light present during zeroing. For narrowband radiation,
The electric current difference divided by spectral responsivity has units . For a stipulated and difference , the inferred radiant flux is ; these numbers illustrate the inference and are not reported measurements. The entire beam must hit the active area, and §5.6 calls for correct wavelength, background subtraction, and operation below detector saturation. If an optical attenuator is fitted, §5.4 requires the calibrated detector–attenuator pair and the matching meter setting.
The calibration itself must connect electric current to independently known incident power. NIST's Spectroradiometric Detector Measurements: Ultraviolet, Visible, and Near-Infrared Detectors for Spectral Power by Thomas C. Larason and others describes this chain. A cryogenic radiometer, an electrical substitution radiometer, compares temperature changes from absorbed light with those from known Joule heating (§5.2). Transfer and working detectors carry that watt scale to a spectral comparator (§5.1). A source, monochromator, focusing optics, shutter, beam splitter, and monitor photodiode illuminate a standard and test detector in turn; calibrated current-to-voltage electronics and voltmeters provide the readout (§§3.2.2–3.2.4, 4.3.1). At each wavelength, subtract blocked-beam signals and normalize each detector signal by the simultaneously sampled monitor signal. Comparison with the standard yields the test detector's spectral responsivity. NIST uses two working standards and alignment normal to the beam (§6.1.1).
Controls distinguish a smaller collected radiant flux from a faulty conversion: block and unblock the beam to check the baseline; check that its footprint fits the active area; verify the calibrated optical attenuator configuration; and test proportional response within the specified operating range. Source drift faster than monitor sampling is not removed. NIST discusses finite spectral bandwidth, stray light, temperature, and spatial response variations (§§3.1.1, 6.2, 7.2). A broadband optical spectrum requires the weighted integral in spectral radiant flux, rather than dividing by an arbitrary single spectral responsivity. These limitations explain why the meter's displayed watts need a stated collection boundary, spectral assumptions, and calibration conditions.
Radiant intensity describes how a source distributes its radiant flux over directions. A small cone of solid angle carries approximately when varies little across it; integrating over all emitting directions recovers the total radiant flux. For a source with isotropy emitting over a full sphere, and a cone carries . A planar source satisfying Lambert's cosine law instead has direction-dependent radiant intensity, even though its radiance is direction-independent.
An ideal point emitter emits radiant flux from one location. It approximates a physical source when its emitting dimensions are small relative to the distances relevant to the calculation. With isotropy, its radiant intensity is for total radiant flux . An extended source generally requires integrating contributions from different emitting positions.
Radiance resolves both position and direction: it is radiant flux per projected area and per solid angle. For a surface element of area , and a small outgoing cone at angle to its outward unit normal,
Here locates the patch and is a unit vector along the outgoing direction. The factor is the patch's apparent area viewed along that direction. The same local definition applies to transmitted or received radiation, choosing the positive projected area for the crossing direction. [ref].
For a planar patch of area with spatially uniform, direction-independent radiance , integrating over the patch gives
Take and . The radiant intensities are and . A sufficiently narrow cone therefore carries approximately or , respectively. Both views have the same radiance : the oblique view presents half the projected area. This is Lambert's cosine law, not a loss of radiance with viewing angle.
Figure 1.
One uniform patch: halving projected area halves radiant intensity while preserving radiance
. The geometric panels show a cross-section of a rectangular patch with the same depth perpendicular to the page. Parallel projection onto a plane perpendicular to the viewing direction changes its width by . The graph gives for the stated patch and marks the exact and cases. Details.
Radiance is useful because it separates a source's local directional output from the geometry of an observation. Integrating over outgoing directions gives radiant exitance; integrating incoming radiance at a receiver gives irradiance. In the stationary vacuum setting of vacuum conservation of specific intensity, a resolved uniform source retains its radiance along each light ray, while the radiant flux received from the whole source can decrease as its apparent solid angle shrinks.
The projected area of a planar patch viewed from a direction is the area of its perpendicular shadow onto a plane normal to that direction. If and are its unit normal and viewing unit vector, then by the dot product. On the outward side, this is . For a rectangle tilted around one edge, the width perpendicular to that edge contracts by and the edge length stays fixed, proving the formula. At grazing view ; interpret the radiance definition by a limit rather than dividing by zero.
Spectral radiance is radiance per unit frequency or wavelength interval. Its astronomical synonym specific intensity is usually written or ; this is a spectral radiance, distinct from the radiant intensity in radiometry. For positive small intervals,
The two expressions refer to the same spectral slice, with the positive widths related through frequency and wavelength . For frequency measured in hertz, , the units are . For wavelength measured in metres, . Integrating over a spectral band gives its radiance, and then multiplying by the collecting projected area and accepted solid angle gives a small uniform beam's radiant flux. A spectral measurement therefore retains information that the band-integrated power alone loses.
For an ideal blackbody, Planck's law gives and at temperature , independent of outgoing direction. Its existing frequency and wavelength peaks of Planck's law illustrate why the coordinate matters. The simpler flat-band calculation below isolates that same change of variables without the thermal physics.
In vacuum, , where is the speed of light. Increasing wavelength decreases frequency, so the ordinary signed differentials satisfy . A spectral slice's positive contribution to radiance must be unchanged. The change of variables formula therefore gives the absolute Jacobian determinant
These formulas use per metre and per hertz. The factor has units , which converts the former density into the latter. If denotes the numerical density per nanometre in , its per-metre value is . Conversely, the per-nanometre value is times the per-metre value. Likewise, a density per terahertz is times its per-hertz value because .
For a concrete stipulated spectrum, let between and , and zero outside. This is exactly throughout the band. Using the exact International System of Units value , the corresponding frequency bounds are
The transformed spectral radiance is on this interval. At it is approximately , and at it is in the same units. These are respectively and per terahertz. Thus a flat wavelength density becomes a decreasing frequency density; relabelling the horizontal axis alone would miss both the shape and the units. [ref].
The equality of band radiances has a short exact proof:
The reversed bounds and the Jacobian determinant preserve the same spectral measure. Each half-band, – and –, carries , although the corresponding frequency widths are about and .
Figure 1.
A flat wavelength spectrum becomes curved in frequency, with equal band radiances
. Matching colours identify the same two spectral half-bands. The shaded areas are each in either coordinate. The right-hand density is plotted per terahertz; the longer-wavelength half-band occupies the lower-frequency, narrower interval. Both total shaded areas are exactly . Details.
A spectrum's peak is consequently a statement about a particular density and coordinate. The frequency and wavelength peaks of Planck's law differ for precisely this reason. Integrated radiance over a specified physical band supplies a comparison that survives the change of variables.
In a transparent, stationary vacuum with Euclidean geometry and observers at rest in the same frame, the radiative transfer equation has zero absorption and emission, so along a light ray. The same specific intensity reaches the observer without geometric dilution. More generally, is a Lorentz invariant; collisionless propagation preserves this ratio along a ray even with gravitational or cosmological redshift, rather than preserving at shifted frequencies. [ref].
The elementary geometry is instructive. Two facing surface elements separated by distance exchange spectral radiant flux
The receiver subtends at the source. Describing that same traveling beam at the receiver instead uses . Both descriptions have identical geometric factors, so conservation of its radiant flux gives equal specific intensities at the two ends. This compares the same propagation direction at both ends, not emission in the opposite direction.
A uniform source remains equally bright per resolved direction under these assumptions, but occupies a smaller apparent solid angle farther away. For a small source of projected area at distance and a small receiver facing it, irradiance is approximately . The radiant flux intercepted by receiver area is approximately . With , and , distances and give and , and received radiant fluxes of and . The inverse-square law concerns collected radiation from the whole source; remains at either distance.
Limb darkening is the decrease of emergent specific intensity toward the apparent edge of a stellar disc. A transit depth then depends on the intensity sampled by the planet as well as its projected area; the uniform-disc area ratio is only an approximation.
For a spherical star of radius , let be distance from the centre of its projected disk and let be the angle between the outward unit normal and the line of sight. The angular coordinate is
Disk centre has ; the apparent edge approaches . A resolved image measures specific intensity in each direction. Limb darkening means that this specific intensity itself falls toward the edge; the projected area factor used when collecting radiant flux is a separate geometric effect.
A simple explanation assumes a horizontally uniform plane-parallel atmosphere, a sufficiently deep optically thick medium, negligible scattering of light, and thermal absorption and emission in local thermodynamic equilibrium. Let be inward vertical optical depth at fixed frequency . An oblique light ray has line of sight optical depth , so it encounters the same attenuation at a smaller vertical optical depth. The formal solution of the radiative transfer equation gives
Here is the source function; under these assumptions it is the Planck function . If temperature increases inward, an oblique view preferentially samples cooler layers and hence lower specific intensity. [ref]
The weight is an exponential distribution in vertical optical depth, with expected value and standard deviation . Thus “seeing down to optical depth one” refers to the line of sight, and represents a broad sampling of layers rather than a sharp emitting surface. For a source function that is linear throughout the atmosphere, the Eddington-Barbier relation is exact:
This follows by integrating the constant and linear terms separately. A constant source function instead gives constant specific intensity, as in the blackbody limit of an isothermal atmosphere. An outward-rising temperature or important scattering of light changes the argument. Close enough to the actual edge, a plane-parallel atmosphere also loses validity because of curvature. Neither one limb-darkening coefficient nor a universal dependence on wavelength follows from this simple model.
The linear limb-darkening law parametrizes angular specific intensity by a stipulated limb-darkening coefficient :
Here denotes specific intensity at one frequency, or radiance integrated over a specified interval of frequency or wavelength; it does not denote radiant intensity. Within this stipulated range, gives a uniform disk and . The linear limb-darkening law is linear in , while its radial profile is curved. In the linear source function example above, when and .
For the illustrative choice , the specific intensity at , , and the limiting edge is respectively , , and . These are synthetic values, not measurements of the Sun. Real optical spectra and stellar atmospheres need not obey a linear limb-darkening law; more flexible profiles can be necessary for accurate exoplanet transit photometry. [ref]
Figure 1.
Synthetic stellar disk and angular and radial limb darkening profiles
. The disk uses the stipulated linear limb-darkening law with . The profiles compare four stipulated limb-darkening coefficients at equal central specific intensity. Shading represents relative brightness, without prescribing a wavelength or copying a solar measurement. Details.
The parameter in the linear limb-darkening law specifies its contrast between disk centre and the limiting edge. Its interpretation requires the chosen law and interval of frequency or wavelength. A limb-darkening coefficient fitted to an exoplanet transit may trade off against the transit impact parameter and planet radius; it is not a direct measurement of one layer's temperature.
For a circular stellar disk whose specific intensity is independent of azimuth, its mean specific intensity over projected area is
The polar coordinates element is after angular integration, and . Substitution of the linear limb-darkening law gives
For a distant observer at distance receiving light normally to the detecting plane, the observed radiative flux is
It is spectral irradiance, with units when is per hertz. The local outward radiative flux per actual surface area is instead , a spectral radiant exitance. In a spherical model with the same stellar atmosphere everywhere, the luminosity is and , consistent with the inverse-square law. Compare disks at fixed or fixed total observed radiative flux explicitly: increasing lowers the total in the first comparison, while the second requires a larger .
A dark, opaque circular planet of radius blocks specific intensity over its overlap with the projected star. With and no transit dilution, the instantaneous exoplanet transit depth is exactly
When , the entire planetary disk is inside the stellar disk, and specific intensity varies little across that disk, small-planet transit weighting reduces to
Here is the projected centre separation divided by . The numerator samples the local specific intensity; the denominator normalizes by the whole star's mean specific intensity. The small-size argument and the distinction between full overlap and ingress are explicit in the original analytic treatment. [ref]
For a short approximately straight crossing at constant transverse velocity , write with at mid-transit, and let be the transit impact parameter. Then and . With stipulated and , a central crossing has mid-transit exoplanet transit depth approximately , whereas gives . A uniform disk would give for either fully overlapping crossing. The brighter central chord produces a deeper dip and the off-centre chord a shorter crossing at the same .
Figure 1.
Two transit chords across the same synthetic limb-darkened disk flux distribution
. Stipulated and ; the coloured curves integrate the occulted specific intensity over the finite planetary disk, including ingress and egress. Dashed curves show small-planet transit weighting only where the whole planetary disk is inside the star. Horizontal dotted segments give the uniform-disk full-overlap depth . The chord panel shows mid-transit positions; the horizontal coordinate in the light curve is distance travelled divided by stellar radius, equivalent to scaled time at constant transverse velocity. Details.
At fixed away from the edge, a two-dimensional Taylor's theorem expansion over the symmetric planetary disk cancels the first derivatives; the first correction to the blocked radiant flux is of order if the second derivatives remain bounded. This error estimate is not uniform at the edge, where the radial derivative of the linear limb-darkening law diverges. Ingress, egress, a grazing exoplanet transit, and a crossing of a starspot require the overlap integral or a suitable more complete model. Inferring without the local-to-mean specific intensity ratio can bias the estimated planet radius.
A motivating measurement used the McMath solar optical telescope at Kitt Peak. The Sun's image drifted across a -high, -wide optical slit; a double-pass spectrograph selected wavelength intervals from wide at to at . An EMI 9750 QB photodetector or silicon photodiode supplied a digitized signal: samples were summed into 4096 positions per crossing, including dark and off-limb sky readings. [ref]
Controls included daily realignment of optical telescope mirrors, wavelength settings between spectral lines insensitive to the rotational Doppler shift, selection of detectors without detectable hysteresis, and measured electronic nonlinearity corrections below of maximum signal. Limb-position calibration combined centres of gravity of the edge derivative profiles with almanac semidiameters; the preliminary edge shifts were consistent with astronomical seeing of approximately arcseconds full width at half maximum. [ref]
The decreasing centre-to-limb readout gives a specific intensity profile, constraining stratification of the photosphere under a radiative transfer model. Astronomical seeing, instrumental scattering of light, and solar granulation limit this inference; brightness alone does not uniquely determine temperature versus geometric height. These observations need not follow the stipulated linear limb-darkening law.
Radiant exitance is total outward emitted radiant flux per actual emitting area, measured in . Integrate radiance over the outward hemisphere, keeping the projected area factor:
If the radiance is direction-independent, the spherical coordinates element is , so
The weighted solid angle is , although the whole hemisphere covers . Directions near grazing contribute less because of the projected area. This geometric factor is the bridge between Lambert's cosine law and the total output of a diffuse patch. [ref].
For the uniform patch with , radiant exitance is . Its area gives total radiant flux over the outward hemisphere. This total differs from its radiant intensity , which describes only one direction.
For an ideal blackbody, integrate Planck's law over frequency as well: by the Stefan–Boltzmann law. An ideal emitting patch of area emits about outward. Irradiance counts incoming radiation separately; for purely emitted output the net outward exchange per area is . Reflected output must also be included if the surface reflects incident radiation.
Radiant power leaving a surface per surface area and per unit frequency or wavelength. Isotropic cavity radiation obeys ; the factor combines the outward hemisphere and projected area.
Irradiance measures incident radiant flux per actual receiving area. Its units match radiant exitance, but it counts the incoming side of the radiation exchange. Measure incoming angles from the unit normal pointing toward the incident hemisphere. Then
For distributed uniformly over , . If the receiving plane is tilted in the same broad uniform parallel beam, the incident power per actual area is halved to . This receiving-surface cosine factor is geometric and does not assume Lambertian reflectance. Together, irradiance and radiant exitance describe how radiation supplies and removes energy at a surface, while radiance preserves the directional information.
Incident radiant flux per unit area and unit wavelength or frequency. Integrating over a wavelength interval gives the contribution to irradiance in that interval. Conversion between and requires the absolute Jacobian determinant associated with , as for spectral radiance.
A parallel beam incident at elevation has horizontal irradiance . Its path optical depth in a plane-parallel atmosphere is . Confusing these projections changes both attenuation and intercepted power.
Radiometric absorptance is the fraction of incident radiant flux converted to heat in the specified receiver: , with for a passive receiver. Specify the entrance boundary, wavelength, incidence angle and receiver temperature. Radiation reflected or transmitted out of that receiver is not absorbed power. A cavity can improve radiometric absorptance by giving light repeated opportunities for wave absorption; a dark coating alone does not establish .
For broadband light, spectral radiant flux matters: . A single effective radiometric absorptance therefore depends on the incident optical spectrum as well as on the receiver. If the stated incident boundary lies before a window of known power transmission , the receiver absorbs when other optical losses are absent. Window loss and receiver radiometric absorptance are separate corrections.
An electrical substitution radiometer measures radiant flux by replacing absorbed optical power with calibrated Joule heating. At fixed temperature, feedback control holds the receiver equally warm with the beam blocked or admitted: after corrections, absorbed optical power equals the reduction in supplied electrical heating. Incident radiant flux additionally requires radiometric absorptance and entrance-path corrections. This connects radiometry to electrical standards.[ref]
Picture a small absorbing cavity connected to a colder reference block by a radiometer thermal link. A heater supplies Joule heating, a thermometer senses the receiver, and feedback control adjusts the heater. When light supplies some of the heating, the controller supplies less. The readout is the change in heater power, rather than the beam's brightness or its number of photons. NIST's institutional description gives a concrete receiver with a conical interior, absorbing coating and weak Kapton support, operated with a receiver heater and thermometer.[ref]
Figure 1. . Original functional schematic, not a drawing of a particular laboratory instrument. The shutter defines dark and illuminated states; incident radiant flux is specified at the receiver entrance. The cavity absorbs a fraction , while the remainder escapes. The reference block and receiver have distinct controlled temperatures. The thermometer signal drives feedback control, and heater voltage and electric current provide the electrical power readout. Lead heating, stray radiation and spatial heating differences require separate checks. Details.
An explicit lumped model makes the cancellation understandable. Treat the receiver as having uniform temperature , heat capacity , heater power deposited in the receiver, net parasitic input , and outward heat transfer to a reference at temperature . With incident radiant flux and radiometric absorptance , conservation of energy gives
The dark state has no admitted beam. Compare settled dark and light states, denoted and ; each has . Subtracting their balances gives
where and . At identical and , with unchanged surroundings and parasitic heating, both correction differences vanish. Thus , and . Notice the signs: extra stray thermal radiation admitted with the beam also reduces heater power, so it must be subtracted from that reduction before attributing the result to the intended beam.
Measure the heater's own terminal voltage and electric current : for steady electrical heating, , where is its electrical resistance. A supply voltage that includes wire voltage drops counts Joule heating in the leads too; only the portion deposited in the receiver belongs in this balance. Changes in that deposited lead heat belong in . Optical-electrical heating non-equivalence adds a further instrument-specific correction when the uniform-temperature model is insufficient.[ref]
A radiometer thermal link is the intentional path for thermal conduction from receiver to reference block. Near a chosen operating point, write with local conductance in . A weaker link increases the steady temperature rise per added power, , but also increases the uncontrolled relaxation time when the link dominates other heat transfer. These are local linear approximations: actual thermal conductivity depends on temperature, and active feedback control introduces its own response. NIST explicitly describes the tradeoff between weaker links and smaller receiver heat capacity.[ref]
Stipulate a model receiver held at with a reference at . Choose , so outward thermal conduction is . Ignore other heat transfer, take in both states, and stipulate perfect optical/electrical thermal equivalence. These values specify an original example; they are not measurements or claimed performance of a NIST instrument.
With the beam blocked, supply . With light admitted, the required heater power is . For stipulated radiometric absorptance at the chosen single wavelength,
The illuminated receiver still gets of heating. The remaining of incident radiant flux escapes without heating it. Calling the measured heater reduction “incident power” would underestimate the stipulated incident radiant flux by .
Figure 1.
The same receiver temperature with different electrical and optical heating
. Original stipulated steady-state example, not experimental data. Both columns total of deposited heating and balance the same outward thermal conduction. Incident radiant flux is , of which is absorbed; the that escapes is outside the heating column. No response time or measured uncertainty is implied. Details.
Two variations expose different pitfalls. First, if admitting the beam also adds of stray heating while the same is absorbed from the intended beam, the heater falls to . The apparent reduction is now ; subtracting recovers the beam's absorbed power. Second, keep the original heater readings but stipulate a light-state receiver offset at fixed reference temperature. The link carries an extra ; the inferred absorbed power becomes , and incident radiant flux becomes . This second variation deliberately violates exact fixed-temperature substitution.
The heater can supply only nonnegative power in this model. Consequently an absorbed beam above the available dark heater power cannot be compensated at the chosen setpoint merely by reducing the heater. The operating point, link, or admitted radiant flux must change; zero heater demand is a range boundary, not evidence of greater radiant flux sensitivity.
Optical-electrical heating non-equivalence means that equal absorbed optical and electrical powers do not necessarily give identical thermometer responses. Light and the heater may deposit heat in different places, producing different temperature gradients and different routes of thermal conduction to the support. Holding one thermometer reading fixed need not hold every part of the cavity at the same temperature. This differs from incomplete radiometric absorptance: one concerns where absorbed heat goes, the other how much incident light becomes absorbed heat.
A useful accounting convention is
where the signed correction is determined by characterization of the instrument and represents the residual departure from the lumped electrical substitution heat balance. It is not a universal extra source of energy. Varying the beam location or heater location, comparing equivalent temperature excursions, and checking repeatable dark returns can test the assumptions; no single small correction proves that every other correction vanishes.
A cryogenic radiometer uses low-temperature operation to improve electrical substitution radiometry through particular material and thermal properties. Lower heat capacity of a copper receiver permits a substantial cavity without proportionately slow relaxation; cold shields reduce unwanted thermal radiation, and heater leads with superconductivity can suppress resistive lead heating. These features do not make radiometric absorptance exactly one or abolish optical-electrical heating non-equivalence.[ref]
Cold surroundings matter as much as a cold receiver. In a simplified gray-surface model, net outward thermal radiation is , using emissivity , area , shield temperature and the Stefan-Boltzmann constant . Cold shields reduce the incoming term as well as the receiver's emission; cooling the receiver alone while leaving it exposed to warm surroundings does not remove incoming radiation. An entrance window still provides an optical and thermal path. Vacuum reduces gas-mediated heat transfer, while an intentional radiometer thermal link remains necessary. This model explains specific losses, rather than promising a universal improvement factor or perfect accuracy.
In NIST's 2001 comparison, the Laser-Optimized Cryogenic Radiometer held its cavity near and controlled the heat sink separately. Opening the beam reduced heater power at fixed cavity temperature; an AC bridge read the temperature. Tests used stabilized, spatially filtered lasers at , and , with horizontal input and a movable photodiode transfer detector in the cavity's optical plane. The paper contrasts this with the High Accuracy Cryogenic Radiometer's optical heating followed by two electrical heating cycles and interpolation.[ref]
The two laboratories compared calibrations of the same transfer detectors, and checked their spatial response. Alignment differences and transported dust limited that comparison; its agreement did not prove universal equivalence. Its correction tables retain window transmission, cavity radiometric absorptance, alignment, electrical readout and optical-electrical heating non-equivalence. The heat sink was controlled, but §3 does not specify its numerical setpoint: the reference in the preceding example is stipulated.[ref]
For a reproducible substitution measurement, record the beam's wavelength and entrance boundary, receiver and reference temperatures, heater terminal voltage and electric current, dark readings before and after illumination, and the settling rule. Check beam collection at the aperture, window transmission, radiometric absorptance, deposited lead heating, and sensitivity to beam position. Repeatability alone misses a stable correction error. Photometric calibration can subsequently use this radiant flux scale, but photometry still needs the appropriate spectral visual weighting; the cold receiver does not itself measure luminous flux.
Articles were limited to the first 100 out of 101 total.

Articles by others on the same topic (1)

Radiometry is the science of measuring optical radiation, which includes electromagnetic radiation in the visible and invisible spectrum, such as ultraviolet and infrared light. It encompasses various concepts and units related to the detection and quantification of light energy, including its intensity, power, and distribution across different wavelengths. Key terms in radiometry include: 1. **Radiant Power (or Radiant Flux)**: The total amount of energy emitted by a light source per unit time, measured in watts (W).