Rectifier 2026-10-18
Reference resistor 2026-11-05
A reference resistor is a resistor whose assigned electrical resistance supplies the comparison value in a resistance-measurement circuit. Its value may come from measurement calibration rather than its nominal marking. The useful reference is its value under the stated temperature, loading and connection conditions, together with the associated measurement uncertainty.
In a shared-excitation resistance ratio measurement, the sensor and reference resistor carry the same electric current. Measuring their electric potential differences gives , so . A reference value error therefore sets a scale error even when excitation cancels perfectly. Reference-resistor error in ratiometric resistance measurement derives the exact relation and distinguishes a correction from its remaining measurement uncertainty.[ref]
The connections define which resistance is compared. In four-terminal sensing, two leads carry the electric current while a separate high-impedance pair senses the electric potential difference at the reference terminals. This avoids including the current-lead drops in the assigned reference value, within the sensing instrument's limitations.
For an original ideal example, a reference resistor carries through two current leads, each of electrical resistance . The reference element has a potential difference of , while a reading outside both leads is . If this latter reading is used as the denominator while the calculation assumes , a true sensor is inferred asSensing directly at the reference terminals removes this idealized lead contribution. It does not correct a wrong reference value. The circuit guide explicitly shows a Kelvin connection at the reference terminals for this purpose.[ref]
A small temperature change shifts the value approximately by , with temperature coefficient of resistance . Excitation also dissipates electric power ; a reference with a different temperature or load from its measurement calibration may require a correction or additional measurement uncertainty. A proposed check compares the reference before and after the measurement sequence under the same connection and loading conditions. Repeating the comparison at a lower electric current tests for a heating contribution. Stability of the observed ratio alone cannot certify the reference's assigned value.
Reflected impedance Created 2026-10-24 Updated 2026-11-05
The reflected impedance is the contribution of a coupled secondary load to a primary winding's input impedance. For two ideal mutually coupled inductors, choose winding signs so that positive electric currents reinforce their magnetic fluxes. If the secondary loop has complex impedance , its Kirchhoff's voltage law gives . Substitution in gives . For , the reflected real part is , and primary mean input power equals secondary mean Joule heating.
The relation between current distortion factor and THD with DC current accounts for the mean component omitted from the usual fundamental-normalized total harmonic distortion. For a periodic electric current, let be its signed DC component, the fundamental RMS magnitude, and the RMS magnitudes of higher harmonic components. The Parseval identity givesDefine and current distortion factor . Division by provesThe root mean square in this expression includes the mean, while the stated total harmonic distortion excludes it. An instrument reporting AC-only RMS or a differently normalized distortion quantity requires a correspondingly different conversion.
For an original example, take , and combined higher-harmonic RMS magnitude . Then , and . Neglecting the DC component would instead predict . In the same conductor electrical resistance , the actual heating is , while that omission would predict .
For a zero-mean sinusoidal supply of RMS and an in-phase fundamental current, the example absorbs . Its apparent power is approximately , so total power factor is despite a displacement power factor of one. The DC component carries no average power from that particular zero-mean supply, but it still increases mean-square electric current. If the supply itself has a DC component, its contribution must be included through the harmonic active power sum.
As tends to zero the defining current distortion factor can tend to zero, but fundamental-normalized total harmonic distortion is undefined at . Do not evaluate the boxed relation there by silently dividing by zero. The manufacturer's documentation also uses differing labels for distortion ratios, reinforcing the need to state the defining normalization.[ref][ref]
Overview of Functions: Harmonic Measurements by Schneider Electric. Quality Indicators, Distortion Factor
Remaining useful life 2026-11-05
Remaining useful life is the future time, cycle count or other usage until a component reaches a specified end-of-life criterion, conditional on its current condition and assumed future operation. The endpoint must be stated: crossing a performance limit, exhausting a discharge and reaching a long-term degradation threshold are different events. For an increasing damage variable , threshold and present time , a mathematical definition is the first-passage timeA prediction of this quantity supports condition-based maintenance, while requiring more than detection of existing damage.
For an illustrative deterministic model, let current normalized damage be0.60, the end threshold1.00 and future damage rate0.02 per hour. Linear extrapolation gives . If the plausible future rate instead ranges from0.015 to0.025 per hour, the corresponding times range from about26.67 down to16h. Remaining useful life uncertainty therefore includes future operating conditions and degradation-model uncertainty, as well as measurement error.
A primary NASA battery-aging dataset makes the endpoint concrete. A custom testbed cycled electric batteries under controlled load and temperature, recording quantities including electric potential difference, electric current and temperature. The reported aging endpoint was30% loss of rated capacity, from2Ah to1.4Ah. That long-term endpoint is distinct from the terminal-potential threshold used to end an individual discharge.[ref]
Li-ion Battery Aging Datasets by NASA. Dataset description, end-of-life criterion and Data Acquisition apparatus list
A useful validation compares predictions made before the endpoint with subsequently observed crossing times under documented operation. Reporting one predicted number without its endpoint, usage assumptions or uncertainty can conceal the main sources of disagreement between a model and a real endurance test.
A reset error budget with a persistent pedestal assigns separate tolerance to a decaying pre-reset residual and an offset created when the reset switch opens. Increasing the preceding discharge time can reduce the former without reducing the latter. The integrator reset settling time article derives the basic worst-case bound and its logarithmic reset-duration requirement.
A focused extension includes leakage during a fixed post-opening readout delay . Let the pre-reset residual magnitude be at most , its decay time constant be , the opening reset charge-injection pedestal magnitude be at most , and subsequent electric current magnitude be at most on fixed capacitance . The triangle inequality givesThis separates a duration-controlled term from an error floor . For and a required guarantee , finite reset time is possible from this bound only when , and
For an original chosen circuit, take , , , , and . Leakage consumes . A total tolerance leaves for the old residual, requiring about of reset. A tolerance requires changing the stipulated pedestal or readout conditions; reset duration alone cannot guarantee it.
These are worst-case bounds, not root-sum-square standard uncertainties. Test the discharge by varying , the opening step with zero-input records, and the subsequent drift by varying . Real charge transfer depends on switching sequence, and prior overload can require separate recovery.[ref]
ACF2101 Low Noise, Dual Switched Integrator datasheet. p11, Charge Transfer and Droop; p10, Output Overload
Accidental cancellation of signed errors is not a reproducible worst-case margin. Resistance thermometer self-heating 2026-10-14
Measuring electric current creates Joule heating, raising the sensing temperature. At fixed bath temperature, compare settled readings at and and extrapolate the approximately linear dependence toward zero current.[ref]
Guide on Secondary Thermometry: Industrial Platinum Resistance Thermometers by Jonathan Pearce and others. §4.1, printed pp. 24–26, equation (4.1.1): self-heating, two-current extrapolation, and medium dependence
Under the local model ,For synthetic readings at and at , the extrapolated value is . The lower-current excess corresponds to in the Pt100 local linear model. At , dissipates ; power alone does not specify a temperature rise without a thermal coupling model. These stipulated values are not measurements.
Repeat the comparison after settling and test the approximation if necessary. Changing from liquid to air changes heat transfer; a self-heating correction need not transfer unchanged. The saturation-pressure equilibrium measurement provides an existing example of controlling this disturbance in resistance thermometry.
Suppose a calibrated measurement bounds the fractional loss of a nonzero superconducting persistent current by , with , over a duration . Take by choosing the circulation direction. Under the constant-, constant-, undriven RL circuit model,The inequality follows because the logarithm is increasing. The final approximation requires and slightly understates the exact upper bound. If is uncertain, an independently established upper bound on gives the conservative electrical resistance bound. The uncertainty in the initial reading, the final reading, background subtraction and drift must all be included in ; a display resolution alone does not provide it.
An illustrative exponential decay, its logarithmic slope and the resulting resistance bound
. Chosen numerical model, not historical data: fixed self-inductance and no external drive. The final panel assumes a calibrated fractional-loss bound of at each chosen observation duration. Longer observation tightens the bound only while that fractional uncertainty remains controlled. Details.For an original illustrative example, let and suppose the corrected electric current ratio after is at least . ThenThese are conditional bounds for stipulated parameters, not values attributed to the 1914 apparatus. With the same but , the model instead gives and : a readily visible loss on the chosen scale.
A resolved decay can be checked using its logarithm:A straight line supports this constant-parameter model; curvature or jumps demand a different account. If an effective electrical resistance varies with time while remains fixed and the loop remains undriven, only its time average is constrained:This does not bound every instantaneous value of . Changing self-inductance or external linked magnetic flux adds terms to the circuit equation, so an uncorrected magnetic signal cannot simply be substituted for . Nonobservation of decay leaves arbitrarily small positive constant electrical resistance compatible with a finite observation: it is not a logical proof that .
The motivating observation is an abrupt disappearance of detectable electrical resistance on cooling, rather than a smooth improvement in conduction. The diagram pairs the measuring arrangement with an idealized transition. Its curves are deliberately synthetic; neither their scales nor their abrupt step are a reconstruction of measured mercury data.
In a report communicated in November 1911, Heike Kamerlingh Onnes described a mercury thread in seven connected glass U-tubes immersed in a stirred liquid-helium bath. Expansion spaces kept freezing mercury from breaking the glass or interrupting the thread. Separate leads supplied electric current and sensed electric potential difference. He compensated a troublesome thermoelectric effect and reversed the main electric current to extract the resistive signal. He reported a rapid fall between and on his stated historical temperature scale, with electrical resistance disappearing at the lower value. The apparatus and control of spurious electric potential differences are part of the discovery, not incidental details. [ref]
https://dwc.knaw.nl/DL/publications/PU00013242.pdf. Kamerlingh Onnes, Communication 124c (1911), §§2–3, pp. 819–821
A modern version places a contacted sample and a calibrated thermometer close together in a cooling environment. Use four-terminal sensing, record the small applied electric current , the sensed electric potential difference , and the sample temperature , then plot . Repeat on warming as well as cooling, and allow readings to stabilize near thermal equilibrium. Disagreement between warming and cooling is a reason to check sample–thermometer lag and reproducibility before quoting a superconducting transition temperature. Mikhailov and Kordosky's undergraduate experiment uses this strategy with liquid-nitrogen cooling. [ref]
https://physics.wm.edu/~evmik/classes/2021_fall_Experimental_Atomic_Physics_251/lab_descriptions/superconductivity/. Mikhailov and Kordosky, Physics 251 superconductivity lab, measurement procedure and discussion
Choose the measuring electric current small enough that Joule heating does not appreciably change the sample temperature, and repeat with a smaller electric current to check that the transition persists. Cancel stable offsets using the reversal described in four-terminal sensing. A reading indistinguishable from zero supplies an experimental upper bound, not a proof of exact zero electrical resistance. If bounds the unresolved resistive electric potential difference, thenFor a stipulated sensitivity and , this is . The bound applies between the sensing contacts; it is not the electrical resistance of the complete wiring. A conducting path through part of an inhomogeneous sample can also make negligible, so the Field-cooled Meissner experiment adds independent evidence about the material's magnetic response.
Resistive load line 2026-10-14
The straight terminal relation of a resistive electrical load satisfying Ohm's law. Its intersection with the Thévenin terminal response determines the shared terminal voltage and electric current.
Resistive magnetic entry of a falling loop Created 2026-10-20 Updated 2026-11-05
A rectangular loop entering a uniform magnetic field while only one horizontal segment is immersed has motional electromotive force . Neglecting self-inductance, its electric current is and its upward magnetic force is . The equation gives exponential relaxation toward . This entry model ends when both horizontal segments enter the field; then their net magnetic force and the rate of change of external magnetic flux vanish.
Resistivity and Hall Measurements by National Institute of Standards and Technology Created 2026-10-20 Updated 2026-11-05
Official text: www.nist.gov/pml/nanoscale-device-characterization-division/popular-links/hall-effect/resistivity-and-hall
Institutional measurement procedures covering contact geometry, reversal of electric current and magnetic field, and extraction of sheet carrier density and Hall mobility. Bulk density requires the conducting thickness.
Resistor-capacitor equilibrium noise 2026-10-18
Connect one physical resistor across an ideal lossless capacitor , with no applied source and an ideal readout that draws no electric current. Represent the resistor by its noisy Thévenin equivalent. The resulting RC low-pass frequency response gives the stationary capacitor voltage power spectral densityIts mean square follows by the effective noise bandwidth calculation:This is also the equipartition theorem: the mean capacitor energy is . Raising makes the low-frequency spectrum taller and its width narrower in exactly compensating proportions. It changes the equilibration time , not the final variance.
The integral to infinity belongs to the ideal classical model. For a physical electrical circuit, assume thermal equilibrium, linear components with negligible extra dissipation, and a corner far below the frequencies where parasitic effects, frequency-dependent electrical resistance, or invalidate the model; the omitted high-frequency tail must be negligible. A finite-bandwidth instrument measures only part of this variance. Its input capacitance contributes to the total , and its finite input electrical resistance introduces both loading and its own thermal electrical noise.
For and , the predicted equilibrium variance is and the root mean square voltage is . At , and . At , and ; the equilibrium root mean square voltage is identical.
To obtain the growth curve, prepare exactly and connect the resistor at while maintaining its temperature. The RC low-pass filter's causal impulse response is for . Classical ideal white noise with two-sided power spectral density givesThe factor here is the two-sided time-domain noise intensity; the equilibrium spectral integral above used the one-sided . They give the same long-time limit. The variance approaches equilibrium with time constant , although a deterministic initial voltage decays with time constant . If the capacitor already starts in thermal equilibrium, its initial variance supplies the missing exponentially decaying term and the total variance stays constant.
Resistor power under fixed drive Created 2026-10-14 Updated 2026-10-20
Whether increasing electrical resistance increases Joule heating depends on what the supply holds fixed. Consider separate ideal resistor experiments with and , each maintained at its specified temperature. At fixed electric current , doubling changes the required electric potential difference from to and doubles power from to . At fixed electric potential difference , doubling halves electric current from to and halves power from to . These are stipulated model values, not measured data.
Increasing electrical resistance has opposite effects on Joule heating under fixed electric current and fixed electric potential difference
. Original calculated comparisons, with on the left and on the right. The marked and cases are separate ideal experiments. Each lower panel shows the companion quantity that changes when the supply holds the other quantity fixed. Details.The comparison also predicts feedback when a particular resistor's electrical resistance rises with temperature: a supply maintaining electric current increases its heating power, whereas one maintaining terminal electric potential difference reduces it. Predicting the actual temperature still needs the material response and its heat transfer to the surroundings; a nominal supply setting does not establish which drive is actually constant at the resistor.
Resonant frequency 2026-10-18
A frequency at which a specified driven response is resonant. The value can depend on the observable and damping: the electric current amplitude of a driven series RLC circuit peaks at , while a different circuit readout need not peak at the same frequency.
Resonant series RLC response Created 2026-10-05 Updated 2026-10-18
Drive a series RLC circuit with electric potential difference , where and . After the free transient decays, the electric current has the same angular frequency as the source:For fixed positive , the electric current amplitude is largest exactly at . The two electrical reactance contributions cancel there, leaving only the drop from electrical resistance. In particular,Every solution approaches this periodic response because its difference from the displayed solution is a decaying free response. The peak remains at even for an overdamped RLC response; free ringing is not required for a maximum of driven electric current. [ref]
University Physics Volume 2 by Samuel J. Ling and others. OpenStax University Physics 2, §15.3: current amplitude, phase, and resonance
.For example, stipulate , , , and . Then , , and the peak electric current amplitude is . Holding the source amplitude fixed is essential when comparing responses at different frequencies.
Three frequencies must be distinguished. The free underdamped RLC response rings at . Driven electric current peaks at . Driven electric charge has amplitudewhose peak occurs at only if . Otherwise it decreases from its zero-frequency limit , with no positive-frequency peak. The different peak locations follow because electric current is the time derivative of electric charge, multiplying a sinusoidal amplitude by . The limiting responses are as and as .
The Q factor measures selectivity:The average Joule heating power is . Its half-maximum angular frequencies and their separation are exactlyThese follow by setting . In the numerical example, and . Reducing makes a taller, narrower electric current peak; varying tunes the selected frequency. Measuring the drop gives a band-pass filter that suppresses very low and very high frequencies while passing a range near resonance. This is useful for selecting a radio signal, though the range must be broad enough to pass its modulation. [ref]
https://www.feynmanlectures.caltech.edu/II_22.html#Ch22-S7. Feynman lectures, II.22.7: resonant filters and radio sidebands
. Return probability from effective resistance Created 2026-10-14 Updated 2026-11-05
For the conductance-weighted random walk on a graph, set . The voltage has boundary values one and zero. The total electric current is . The first-step analysis therefore gives the displayed positive-return-time formula. Wiring the exterior of finite sets and taking limits gives .
Reversal potential 2026-10-13
A reversal potential is a membrane potential at which a specified open ion channel, or specified combination of ion channels, carries zero net electric current, with the surrounding conditions fixed; the electric current changes sign across that voltage. Specifying which current matters: an individual ion contribution and a sum of several contributions can reverse at different voltages. Zero net electric current does not mean that all ions have stopped moving. See Purves et al., Neuroscience, 2nd edition (2001): reversal of a mixed-ion channel current.
Throughout these examples, membrane potential is , and conventional current is inward-positive. Positive electric current corresponds to net positive electric charge entering or net negative electric charge leaving. Negative electric current corresponds to the reverse charge transfer. A convenient Ohmic approximation iswhere is the available electrical conductance. For fixed , gives positive electric current, gives zero, and gives negative electric current; the line has slope . If , the modeled pathway carries zero electric current at every voltage: closing it does not locate its reversal potential. 3.1 Synapses (§3.1: conductance-based synaptic current) uses outward-positive ; the formula here reverses that sign to match this wiki's inward-positive convention.
For the stipulated single-pathway example from ion channel, and giveThe open ion channel carries zero net electric current at even though remains positive. Near that point a change of membrane potential changes the electric current, which is why zero current at one voltage does not make an open pathway electrically irrelevant; see shunting inhibition.
Inward-positive electric current: one reversal and two-channel cancellation
. Original computed curves for stipulated constant electrical conductances and fixed reversal potentials. Left: , . Right: a potassium pathway with , and a sodium pathway with , . Their net electric current vanishes at while both individual electric currents remain nonzero. These are model values, not empirical measurements. Details.For an ion channel passing only one ion species by passive transport, its reversal potential can equal that species' Nernst equilibrium potential, where the chemical and electrical contributions to electrochemical potential balance. At that thermodynamic equilibrium, passage in both directions can continue with no net transport. For an ion channel admitting several ion species, opposing contributions can cancel while each species continues to have net transport. Such a reversal potential is not generally any one species' Nernst equilibrium potential. See the Purves reference above.
To work out that cancellation explicitly, put two Ohmic ion channel populations across the same cell membrane. Stipulate constant electrical conductances and fixed reversal potentials:The potassium and sodium contributions add because both pathways experience the same membrane potential:Thus . This weighted mean follows simply by expanding and regrouping the two current terms; it assumes additive Ohmic contributions and a positive total electrical conductance. At , the inward-positive individual electric currents areThe potassium contribution is outward and the sodium contribution inward. Equal and opposite electric currents give ; neither pathway has stopped transporting its ions. The calculation treats two distinct pathways. Applying it to one mixed-species ion channel would additionally require a justified decomposition into independent Ohmic contributions; a general mixed-channel reversal potential cannot be obtained by assuming those hypotheses silently.
This is an instantaneous balance of the specified passive electric currents. It would be the stationary voltage of a passive capacitance model containing only these constant pathways and no applied electric current, but it is not a complete prediction of a living cell's resting membrane potential. Other electric currents, voltage-dependent gating, and pumps involved in active transport can matter. Pumps that transfer net electric charge are electrogenic and contribute their own electric current. See Purves et al.: functional properties of the sodium/potassium pump.
The toy model holds ion concentrations and therefore the stipulated reversal potentials fixed. Continuing inward sodium and outward potassium transport would change finite reservoirs unless active transport or external control maintained them. Transport can be a small fraction of the reservoir's ions over a short interval, making fixed concentrations a useful approximation; it is not a claim that the reservoirs never change. See Gerstner et al., Neuronal Dynamics (2014), §2.1: equilibrium potentials, channel currents and maintained gradients.
A reversal potential makes the effect of opening an ion channel predictable from the present membrane potential. The same open pathway can carry inward or outward electric current as crosses its reversal potential. The two-pathway example reveals a particularly useful distinction: zero net charge transfer can coexist with continuing exchange of different substances. That distinction connects membrane transport to electric current measurements without mistaking electrical balance for thermodynamic equilibrium.
Richardson-Dushman law Created 2026-10-18 Updated 2026-10-20
The Richardson-Dushman law models the magnitude of emitted electric current density asHere is absolute thermodynamic temperature, is the work function, is the Boltzmann constant, and is the Thermionic Richardson constant. The signed electric current density points opposite to the outgoing electron motion; here is positive. For uniform emission over area , the emitted electric current magnitude is .
The Richardson-Dushman law assumes an emitter close to thermal equilibrium, a surface with a well-defined and approximately constant work function over the fitted temperature range, and predominantly thermal escape over the barrier. Interpreting a measured collector electric current with this law additionally requires an emission-limited thermionic current, known emitting area, and negligible return emission from the collector. Strong electric fields can lower the surface barrier or enable quantum tunnelling; then this zero-field expression is insufficient.
For a deliberately chosen teaching model, take and , expressing the barrier in electronvolts. These are illustrative parameters, not measured properties of a named material. Using , at the Boltzmann factor is about , yetA 20 percent increase in temperature raises the predicted electric current density by about 69 times. For a chosen emitting area , these correspond to approximately and if collection is complete. The small escaping fraction is replenished by the external electrical circuit.
The sensitivity is especially clear from the logarithmic derivative at fixed :In the chosen model at , a rise changes by about 2.5 percent to first order. Accurate temperature measurement matters even when electric current measurement is easy.
Richardson hot-wire emission experiment 2026-10-18
In his Nobel lecture, delivered on 12 December 1929 for the 1928 prize, Owen Willans Richardson recalled heating wires for weeks while hand-pumping away gas released by the apparatus. With platinum, he found a finite emission per unit area that rose rapidly with temperature. His initial 1901 formula used ; he preferred the form in 1911.[ref]
Thermionic Phenomena and the Laws which Govern Them by Owen Willans Richardson. Nobel Lectures, Physics 1922–1941; pp. 224–225 and 229, preparation and chronology
The early apparatus surrounded a heated platinum wire with a metal cylinder connected to earth through a galvanometer. Wire electrical resistance supplied the temperature readout. After checking collection saturation, Richardson measured at a wire potential of , over roughly –; reversing polarity suppressed the negative discharge.[ref]
O. W. Richardson and the Electron Theory of Matter, 1901–1916 by Ole Knudsen. Histories of the Electron: The Birth of Microphysics edited by Jed Z. Buchwald and Andrew Warwick; pp. 229–231, resistance thermometry and Fig. 7.2, reproducing the 1903 apparatus
Heated-wire emission and separate collection and temperature measurements
. Original functional schematic of the measurement principle, with a wire and surrounding collector shown in section. The layout is simplified; no dimensions or instrument performance are asserted. Details.The inference rests on several controls. A temperature sweep probes thermal escape; reversing the collecting electric field tests the sign of the mobile electric charge; varying collection voltage tests whether transport is limiting. Prolonged pumping and heating test whether a transient gas release is responsible. These controls address different alternatives, and none by itself establishes a clean, uniform surface.
For a modern repetition, stabilize each temperature, measure the collector electric current against collecting electric potential difference, and record the pressure and surface preparation. Repeat selected temperatures after cooling to reveal drift. Use the collection plateau and the actual emitting area to construct a Richardson plot. The resulting slope estimates the work function only within the stated surface and transport assumptions; it does not turn an uncontrolled wire into a reference material.