Self-inductance Created 2026-10-06 Updated 2026-10-14
Self-inductance is inductance associated with a coil's own electric current, rather than magnetic flux supplied by another coil. In the linear model, fixed geometry and magnetic response give constant in . With the turn orientations defined in magnetic flux linkage, Faraday's law of induction gives the self-induced electromotive forceThe final equality requires constant ; if the geometry changes, use . The minus sign expresses Lenz's law: the induced electromotive force opposes the change in electric current. It does not always oppose the electric current itself. When positive electric current decreases, the induced electromotive force acts in its direction. [ref]
https://openstax.org/books/university-physics-volume-2/pages/14-2-self-inductance-and-inductors. OpenStax University Physics 2, §14.2: self-induced emf and its direction
.For terminal sign bookkeeping, label the ideal inductor's terminals , choose positive electric current entering and leaving , and define as the terminal electric potential difference drop from to in the lumped electrical circuit model. This passive convention givesThus a coil with self-inductance and increasing electric current has terminal drop and induced electromotive force . These signs describe the same process with different reference conventions. The RL circuit uses the terminal-drop convention throughout.
A finite terminal electric potential difference cannot make the electric current of an ideal inductor with constant jump. Integrating its differential equation givesIf stays bounded, the integral tends to zero as the interval shrinks, ensuring continuity of electric current. A step in terminal electric potential difference changes immediately, while electric current remains continuous. At constant electric current, the self-induced electromotive force is zero, although the inductor's magnetic energy can remain nonzero.
Series circuit 2026-10-18
A series circuit connects components along one unbranched path, so any electric current through the connected components is the same. Oriented terminal electric potential differences add along that path. In an open-circuit measurement, negligible electric current permits the electromotive forces of serially connected sources to add without appreciable internal electrical resistance drops.
Series RC impedance 2026-10-18
Consider a stipulated series circuit containing an ideal resistor of electrical resistance and an ideal capacitor of capacitance . The same electric current passes through both. Their terminal electric potential differences add by Kirchhoff's voltage law, soA quick derivation uses : taking the derivative of the complex exponential multiplies the capacitor voltage phasor by , hence . Dimensionally, has units , matching .
At frequency , the angular frequency is . The signed capacitive electrical reactance, modulus and complex argument of the total electrical impedance areApply across the complete series circuit. Its root mean square electric current isWith voltage as the zero-phase reference, the current phasor has complex argument : electric current leads. The phasor drops have moduli and ; these add as complex numbers, not as positive magnitudes. Their squared magnitudes sum to .
The mean absorbed power uses the root mean square values:The ideal capacitor has zero cycle-averaged absorbed power; all the mean absorbed power becomes Joule heating in the resistor.[ref]
University Physics Volume 2 by Samuel J. Ling and others. §15.4, equations 15.12–15.14 and the capacitor/inductor paragraph: RMS average power and zero ideal reactive average power
To see why the phase factor appears, average over a full cycle with and . The cosine addition formula reduces the average to ; the term at averages to zero. Independently, , and the capacitor energy returns to its starting value after each cycle.At fixed applied , the limit gives , and : the ideal capacitor blocks steady electric current. The limit gives , and . These are limits of the ideal lumped electrical circuit; unwanted lead inductance and component losses can invalidate that model at high frequency. At , the equal legs of the impedance right triangle give and without numerical evaluation. Measuring both the magnitude and the sign of the phase difference distinguishes this capacitor response from an equally large positive electrical reactance.
Series RLC circuit Created 2026-10-05 Updated 2026-10-20
In a series RLC circuit, the same electric current flows through the resistor with electrical resistance , the inductor, and the capacitor. Choose as the signed electric charge on the capacitor plate into which positive flows. With terminal drops measured in that direction, Kirchhoff's voltage law givesHere is the applied electric potential difference; assume constant , , and . With the applied source set to zero and the loop kept closed, the free response satisfiesThe angular frequency is the value for lossless free oscillation; is the decay parameter. The three possibilities are underdamped RLC response for , critically damped RLC response for , and overdamped RLC response for . [ref].
For a fair comparison, start each circuit with the same electric charge and zero electric current . Set and ; then obeys . The plot compares . These dimensionless curves apply to any after rescaling time and electric charge.
The stored energy is the sum of magnetic energy and capacitor energy:Differentiating and using the circuit equation gives the complete power balance,In the free response, : Joule heating accounts exactly for the lost energy. For the plotted initial conditions, and . Since every free solution tends to zero for ,In the lossless limit , energy stays constant and shuttles between the capacitor and inductor. Thus an oscillation of electric charge and a decrease of total energy are compatible statements.
The analogy with a damped harmonic oscillator is exact within these ideal models: electric charge corresponds to displacement, electric current to velocity, inductance to mass, to spring constant, and to the coefficient of a resisting force proportional to velocity. The two stored energy terms play the roles of kinetic energy and elastic potential energy. [ref]
https://www.feynmanlectures.caltech.edu/I_23.html#Ch23-S3. Feynman lectures, I.23.3: the oscillator analogy
.Differentiating the driven equation also gives . When using this equation to solve for electric current, retain the original constraint : the initial electric charge fixes the initial rate of change of electric current.
Shockley diode equation 2026-10-18
For a p-n junction at fixed temperature, the Shockley diode equation models its electric current asHere is the diode saturation current, the diode ideality factor, the thermal voltage, the Boltzmann constant, and the elementary charge.[ref]
The Junction Diode by W. Marshall Leach, Jr.. The Junction Diode, §1.2, printed p. 4, equation (1.1) and parameter definitions
For an original model example, choose , , and . Using and gives . Then gives , whereas gives . These are predictions of the declared model. There is no universal turn-on electric potential difference: solving the Shockley diode equation for the value needed at a chosen electric current givesAt , increasing by multiplies the electric current by approximately . At the same model gives . Its reverse branch approaches ; it cannot describe diode reverse breakdown.
A constructed extension adds internal series electrical resistance to a junction whose electric potential difference is . Applying the Kirchhoff cycle law givesFor and the same , sustaining needs : across the junction plus across its internal electrical resistance. The derivativeshows why the current-voltage characteristic becomes nearly a straight line when the internal series electrical resistance dominates. This is still a fixed-temperature model; self-heating can change , and . Real diodes also have leakage and charge-storage effects omitted here.[ref]
The Junction Diode by W. Marshall Leach, Jr.. The Junction Diode, §§1.3, 1.8 and 1.11: temperature dependence, charge storage and series bulk resistance
Shockley-Queisser limit Created 2026-10-18 Updated 2026-10-20
The Shockley-Queisser limit is the radiative conversion-efficiency bound for an ideal single-junction solar cell, with one collected electron-electron hole pair per absorbed above-gap photon, carrier thermalization, and radiative recombination required by the reverse optical process. Photons below the band gap are not absorbed, while excess photon energy above it is thermalized. Maximizing the electrical power over the operating electric potential difference and then the band gap gives a ceiling of roughly thirty percent for ordinary unconcentrated sunlight; its precise value depends on the incident spectrum, cell temperature and emission geometry. The original calculation by William Shockley and Hans-Joachim Queisser obtained approximately at for a blackbody source and a cell at .[ref]
Short circuit Created 2026-10-18 Updated 2026-11-05
An ideal short circuit fixes zero electric potential difference across a terminal pair, corresponding to zero load electrical impedance. At the end of a lossless transmission line, its voltage-wave reflection coefficient is and the terminal voltage is zero. The available current is still limited by source and circuit impedances; real short circuits can dissipate substantial Joule heating.
Shunt resistor 2026-11-05
A shunt resistor is a resistor used to establish a known relation between current and a measured electric potential difference. For current sensing, it is placed in the measured current path, and Ohm's law givesThe voltage-sensing circuit should draw negligible extra current for this simple relation to describe the desired branch current. Its small series voltage drop is often called the burden voltage.
An original example uses and . The sensed drop is50millivolts and Joule heating dissipatesReducing resistance lowers both the burden and dissipation, but also reduces signal relative to a fixed amplifier offset or readout noise. The nominal resistor value alone therefore does not determine measurement quality.
Lead and contact resistance can dominate a low-value shunt. If a10milliohm shunt is inadvertently measured together with2milliohms of current-carrying interconnect, interpreting the total voltage using only the nominal shunt value overestimates current by20percent. Four-terminal sensing separates the high-current connections from the voltage-sense connections. Analog Devices' LTC6115 data sheet illustrates these Kelvin sense paths and explains how interconnect resistance introduces error.[ref]
A practical characterization drives known currents through the shunt while measuring the voltage at its sense terminals, then repeats after thermal settling. Temperature coefficient of resistance, self-heating and connection geometry affect the realized conversion. The amplifier's operating range and measurement calibration must be assessed alongside the resistor.
A shunt converts current into a local voltage signal; it does not inherently provide electrical isolation between the measured circuit and its readout. High-side current sensing and low-side current sensing describe alternative placements of that measurement relative to the load and reference conductor.
Signal Created 2026-10-13 Updated 2026-10-14
A signal is a function or sequence representing a quantity that carries information. An electric potential difference measured over time can be written ; regularly recorded values give a discrete-time signal . The meaning includes the measured quantity, units, time reference and sampling interval. The same list of numbers sampled once per second or once per millisecond describes different physical frequencies.
Signal-to-noise ratio 2026-10-18
A signal-to-noise ratio compares a chosen measure of a signal with the corresponding noise measure. For a constant measured electric potential difference and a root mean square noise voltage , an amplitude ratio is ; the corresponding power ratio under equal electrical resistance is its square. State the convention and measurement signal bandwidth, since changing either changes the numerical ratio.
Sinusoidal steady state 2026-11-05
The sinusoidal steady state of a stable linear time-invariant system driven by a sinusoid is its persistent response at the driving frequency, after the relevant transient response has decayed. A phasor calculation finds that response; it does not generally satisfy the circuit's switch-on initial conditions. The late-time assumption is explicit in Berggren's treatment of sinusoidal circuit analysis.[ref]
6.200 Notes: Sinusoidal Steady State by Karl K. Berggren. p3, start-up transient assumption; pp10–11, complex exponential solution
Using peak phasors, write the source as . If is the relevant transfer function, its particular solution isThe complete response adds a homogeneous solution determined by the initial conditions. Approaching the displayed expression requires the modes affecting the measured output to decay; an unchanged amplitude and a fixed phase shift then characterize its frequency response.
For an original turn-on example, drive a series RC circuit with for , measure the capacitor's electric potential difference, and take . With time constant , Kirchhoff's voltage law gives the first-order linear differential equationPut . Substitution verifies the sinusoidal particular solution . Adding and imposing the initial condition fixes , givingIts sinusoidal part has amplitude and lags by . The exponential settling bound for RC sinusoidal turn-on, relative to that amplitude, isWith chosen , , and , we have and . At turn-on the phasor approximation predicts 0.5 volt while the capacitor is initially at zero. After 5 milliseconds, their difference is about 3.37 millivolts, or 0.476 percent of the sinusoidal amplitude. A 1 percent settling time threshold for this specific switch-on is about .
A useful measurement compares a long, low-frequency square-wave response with sinusoidal responses at several frequencies. An oscilloscope can identify the exponential decay and then measure amplitude ratios and phase shifts. MIT's laboratory uses that sequence to connect the time constant to the sinusoidal response; probe loading belongs in the measured circuit model.[ref]
Laboratory 11: Sinusoidal Steady State Response of RC and RL Circuits by MIT OpenCourseWare. pp1–2, natural decay and sinusoidal amplitude/phase observations
Undamped resonant forcing has no bounded sinusoidal steady state. For an ideal series LC circuit, let be electric charge and . At resonance, the equationhas the particular solution . Its growing envelope prevents a bounded attracting sinusoidal response. This ideal counterexample explains why decay of the relevant homogeneous solutions is part of the physical steady-state assumption.
Slide-wire resistance bridge experiment 2026-10-14
PHYWE's documented experiment uses a one-metre slide wire, a connection box, an unknown resistor, a known comparison resistor, a supply, and a digital multimeter in steady-current mA mode as the null detector. Its two yellow detector leads join the fixed-resistor junction and the slider. Move the slider until the indicated electric current vanishes; read the two wire lengths on the ruler and infer the unknown electrical resistance from their ratio. The guide advises changing the comparison resistor if no null is reachable or the slider lies near an end.[ref]
The inference requires uniform electrical resistivity and wire cross-sectional area, so the two wire electrical resistances have the ratio of their lengths, by . Retaining PHYWE's labeling, its equation (6) is , where is the comparison electrical resistance. This is a different arm placement from our schematic. The guide's example table reports larger discrepancies near wire ends.[ref]
Useful additional controls distinguish a true null measurement from an insensitive or disconnected detector. Check the detector zero with the supply off, then move the adjustable arm slightly to either side of the candidate balance and verify opposite detector signs. Reconnect the unknown with short, secure leads and repeat the balance. Any lead or contact electrical resistance included in that arm contributes to the inferred value, even though a detector lead carries no electric current at exact balance. For very small unknown electrical resistances, four-terminal sensing addresses this separate connection problem; a detector null alone does not remove it.
Check for Joule heating by repeating at lower supply electric potential difference and with shorter powered intervals, holding ambient temperature fixed. At balance the unknown still dissipates powerHalving quarters this power while halving ideal detector sensitivity. A balance that moves with excitation or elapsed time suggests changing electrical resistance, including self-heating; it is not explained by passive detector loading alone. These are proposed controls, not claimed outcomes of PHYWE's experiment. Standard-resistor accuracy, wire uniformity, contact reproducibility and finite detector resolution still limit the electrical measurement. Large electrical resistances also make unwanted leakage paths consequential.
Small-signal model 2026-10-18
A first-order Taylor expansion of an electrical circuit's response about an operating point. It describes small changes in electric potential difference and electric current; the neglected higher-order terms limit the useful signal range.
Solar cell Created 2026-10-18 Updated 2026-11-05
A solar cell converts incident light into electrical power through the photovoltaic effect. A semiconductor p-n junction separates and collects photogenerated electrons and electron holes. An ideal illuminated junction has output current densityHere is the short-circuit current density, is the diode saturation current, and is the open-circuit electric potential difference. The conversion efficiency is the largest delivered divided by the incident power per unit area; the short-circuit and open-circuit operating points themselves deliver zero power.
Solar-cell fill factor 2026-10-18
The solar-cell fill factor compares the maximum delivered electrical power with the rectangle formed by the open-circuit electric potential difference and short-circuit electric current. It measures the shape of the illuminated current-voltage characteristic. The conversion efficiency is .
Space-charge-limited thermionic current Created 2026-10-18 Updated 2026-10-20
A space-charge-limited thermionic current occurs when the negative space charge of emitted electrons creates an electric field that obstructs further transport across the gap. Raising the emitter temperature may then increase the surface supply without producing the corresponding collector electric current. The gap geometry and collecting electric potential difference matter even when the surface is stable.
To distinguish this from an emission-limited thermionic current, vary the collecting electric potential difference at fixed emitter temperature, then repeat at another temperature. A voltage-dependent transport region followed by a collection plateau separates a gap constraint from a supply constraint. A weak collector electric current alone cannot establish a high work function. Nor does simply choosing a very large collecting electric potential difference guarantee a valid zero-field measurement: the surface barrier may then change.
Spark chamber Created 2026-10-18 Updated 2026-11-05
A spark chamber reveals a charged particle path as a sequence of electrical sparks between conducting plates. The particle first leaves an ionization trail in the intervening gas. A promptly applied high electric potential difference causes discharges preferentially near that trail, making it visible.
External scintillation counters can detect a crossing and trigger the voltage pulse while the trail remains available. Photographing sparks in several gaps samples the trajectory; it does not make each spark a direct photograph of the particle. Timing, gas condition and electrode geometry affect efficiency. [ref]
https://www.hep.phy.cam.ac.uk/~lester/teaching/SparkChamber/NIKHEF/eppog.web.cern.ch/eppog/Resources/SparkChamber.html. CERN European Particle Physics Outreach Group spark-chamber apparatus: trigger counters and pulsed plates
Spark gap 2026-10-14
A spark gap separates two electrodes; sufficient electric potential difference can cause an electrical discharge through the intervening gas.
Stark canal-ray experiment 2026-10-18
In 1913 Johannes Stark reported that an applied electric field resolved the hydrogen and spectral lines into five components at his instrument's spectral resolving power, viewed perpendicular to the electric field. Three inner components had polarization of an electromagnetic wave perpendicular to the electric field; two outer components had it parallel.[ref]
Observation of the Separation of Spectral Lines by an Electric Field by Johannes Stark. Stark, Nature 92 (1913), p. 401, two opening paragraphs; issue dated 4 December
In his lecture of 3 June 1920 for the 1919 prize, Johannes Stark describes canal rays emerging through a perforated cathode into the electric field between it and a supplementary electrode. A spectrograph recorded the emitted light. His earlier Doppler effect comparison used a collimator perpendicular to the beam and then along approaching rays. Later beam/electric field reversal changed component intensities.[ref]
Structural and Spectral Changes of Chemical Atoms by Johannes Stark. Nobel Lectures, Physics 1901–1921; Stark, Structural and spectral changes of chemical atoms, printed pp. 430, 433–435; lecture date p. 427
The historical account distinguishes observation perpendicular to the electric field, with five resolved components, from observation parallel to it, with three. These are viewing directions, distinct from the direction of the polarization of an electromagnetic wave.[ref]
The Discovery of the Stark Effect and Its Early Theoretical Explanations by A. J. Kox. Kox, The discovery of the Stark effect and its early theoretical explanations, §2 Johannes Stark, paragraph following Figure 2
The experimental distinctions matter. Changing the viewing direction tests a Doppler effect contribution; changing the applied electric field tests the Stark effect; analyzing polarization of an electromagnetic wave separates components that may overlap in an unpolarized record. A comparison with the unperturbed spectral line fixes the origin of a displacement. These are different controls, and the earlier Doppler effect comparison should not be described as a field-off control of the later discovery. A spectrograph's finite spectral resolving power can merge several components into one. In particular, a count of visible spectral lines does not by itself count all energy eigenstates.
Stark spectroscopy: field, beam and viewing axes
. Original conceptual reconstruction of the canal ray source and two alternative viewing geometries. No dimensions, electric field strengths or measured wavelengths are specified. The axial optical path requires an opening or adapted electrode; it is not a ray passing through the solid electrode drawn here. Details.For a modern idealization of the gap, an electric potential difference over separation gives only if edge effects and the charge density in the gas are negligible. This is a calibration model, not a historical value assigned to Stark's apparatus. Similarly, a canal ray beam need not be a pure beam of neutral excited hydrogen atoms; the quantum mechanics model below isolates one neutral hydrogen atom from the source's preparation and collision processes.