Step voltage 2026-10-31
The electric potential difference between the ground-contact points of the two feet. A ground current can make it nonzero.
Stopping potential Created 2026-10-18 Updated 2026-10-20
A stopping potential is the magnitude of the retarding electric potential difference just sufficient to stop collection of even the fastest relevant electrons in an ideal collection geometry. Since the electron's electric charge is , the positive energy barrier is . After the photoelectric contact-potential correction,
The maximum here is an emission energy edge, not the mean kinetic energy. In an ideal planar retarding geometry, transmission instead selects the component normal to the plates; identifying its endpoint with the full edge requires collection of trajectories that attain that edge in the relevant direction.
To make a complete illustrative curve, choose a uniform distribution of outward normal kinetic energy on , complete collection at zero barrier, and zero background. This is a deliberately chosen distribution, not a prediction of the Einstein photoelectric equation. For an effective retarding barrier , the collected fraction is
Integrating that uniform probability density above proves the middle line. Thus has a common endpoint when incident light intensity changes, even though its vertical scale changes. Real emission distributions need not give straight segments.
Figure 1.
Frequency sets the emission energy edge; light intensity sets a collection scale
. Original chosen single-photon model with work function . Left: the allowed upper kinetic energy edge begins at the photoelectric threshold frequency; the dotted continuation is an unavailable single-photon channel. Right: the chosen uniform-normal-energy collection model at , with , , and incident powers and . The shared stopping potential is about . No points or curves are measured data. Source. Details.
The magnetic energy stored in a linear solenoid of constant self-inductance is
in the long-solenoid approximation. The first formula is an inductor relation; the second identifies its storage with magnetic energy in the interior magnetic field, under the vacuum-core approximation. This agreement joins the electrical circuit description to the spatial magnetic field description. The expression is the vacuum magnetic energy density. [ref].
A short derivation starts from the terminal electric potential difference , with positive electric current entering the terminal at higher potential. The absorbed power is , and integrating from zero electric current gives
The result describes recoverable storage in the inductor; Joule heating in the wire is a separate expenditure of energy. [ref].
For the long-coil example, and give . Substituting the ideal and volume into gives the same value. Doubling electric current quadruples stored magnetic energy. In a real coil, reducing electric current can return this energy to an electrical circuit, or release it as Joule heating in a closed RL circuit.
Superconductivity Created 2026-10-06 Updated 2026-10-20
Superconductivity is a phase of matter that supports steady electric current with zero bulk electrical resistivity and exhibits the Meissner effect: equilibrium screening of a sufficiently weak, static magnetic field from the interior. It occurs below a material-dependent superconducting transition temperature, provided the electric current and applied magnetic field are also sufficiently small. [ref] Bulk expulsion means that a sample much thicker than its London penetration depth has an almost field-free interior; the magnetic field need not vanish at its surface. Conventional BCS theory explains superconductivity through correlated electrons forming Cooper pairs. [ref]
The two observations answer different questions. A resistance-versus-temperature experiment for superconductivity asks whether a steady electric current requires a measurable electric potential difference. A Field-cooled Meissner experiment asks whether a magnetic field already present in the material is expelled when it enters superconductivity. An ideal perfect conductor with zero electrical resistivity can preserve that pre-existing magnetic field; zero electrical resistance alone therefore does not establish the Meissner effect.
The usefulness follows directly from Joule heating, : maintaining a steady electric current through a segment with zero electrical resistance produces no resistive heating in that segment. This makes persistent electric currents attractive for producing steady magnetic fields. The beauty is that one phase has both a transport property and an equilibrium magnetic response, and the second cannot be inferred just by making an ordinary electrical resistance very small. The London equations encode this extra magnetic response. [ref]
Supply rate 2026-11-05
A supply rate specifies the instantaneous quantity whose time integral is compared with a change of storage function in dissipativity. With control input , plant output and state , a chosen function enters the balance
The supply rate can be negative: it then represents net withdrawal in the chosen accounting. Its physical interpretation depends on the variables and sign convention, rather than on the word supply alone.[ref]
For a mechanical terminal with applied force and inward-convention velocity , choose , the entering power. For an electrical terminal with electric current entering its positive-potential terminal, the corresponding choice is , with an electric potential difference. Both have units of watts when is energy. Reversing one terminal sign without changing the other reverses the apparent power flow.
An original capacitor example illustrates the sign. Let , terminal electric potential difference , and charging electric current . Its stored electrostatic energy is , and at that instant . With the same potential and , the supply rate is and storage decreases. This is consistent with nonnegative stored energy; negative supply does not mean negative storage.
A different supply rate can express a signal-performance requirement:
Nonnegative final storage and zero initial storage then bound accumulated output-square by times accumulated input-square. These squares need not be physical power. Scaling or changing the units of the signals requires corresponding changes in the coefficients. A general real quadratic choice can be written as , with symmetric ; the selected quadratic form states which input–output relation is being tested.
A switching-current distribution of a Josephson junction records the bias electric current at the first detected transition to a sustained nonzero electric potential difference. Interpret it using a stipulated monotone ramp , a reproducible initial trapped state, and an instantaneous escape hazard function . Neglect retrapping and readout delay. The survival function obeys , so changing variable from time to electric current gives
Here is a probability density function per unit electric current, not a rate per unit time. Division by the surviving population is essential: only trials still trapped can escape. A typical switching current is consequently not identical to the noiseless superconducting critical current.
Figure 1.
From trapped phase to a voltage event and an escape probability
. Original functional readout model and chosen constant-rate calculation. Boxes represent functions rather than historical wiring. The plotted survival function and switching probability density function assume and with perfect event detection and no retrapping; they are not experimental traces. Details.
For an independent illustrative check, choose constant and . Then
Half the trials have switched after , corresponding to of ramp. Doubling doubles the mean increment without changing the underlying escape rate. Real junction rates vary sharply with bias; this example isolates the statistical conversion.
Repeating the preparation, measuring the ramp, resolving the voltage onset, and allowing cooling after each dissipative event are prerequisites for this interpretation. Missed events, finite detection delay, changing temperature and retrapping alter the measured distribution. Even a correctly reconstructed rate needs the independent thermal and spectral checks before identifying its escape mechanism.
Synaptic integration Created 2026-10-13 Updated 2026-11-05
Synaptic integration is the conversion of inputs at a neuron's synapses into a changing membrane potential and, in a spiking neuron, the timing or absence of action potentials. Spatial summation concerns inputs at different locations; temporal summation concerns inputs at different times. A useful question is whether individually ineffective inputs can act together, and whether an inhibitory postsynaptic potential changes that cooperation. The answer depends on location, timing and the receiving neuron's state.
A synaptic potential is a voltage response, whereas synaptic conductance describes activated ion channels. With inward-positive electric current, the contribution of input is
Here is its synaptic conductance, its reversal potential and the local membrane potential. The driving force is an electric potential difference. An EPSP generally brings the membrane potential toward a more positive reversal potential, but its driving force shrinks during depolarization. An IPSP need not produce hyperpolarization: a reversal potential above rest but below the neuronal firing threshold can produce depolarization while opposing a larger excursion. At , the added synaptic conductance initially carries zero electric current yet can cause shunting inhibition of another input.[ref]
Two distinct nonlinearities matter. Even a passive cell membrane can show sublinear synaptic integration when added synaptic conductances reduce driving force and effective electrical resistance. Active voltage-gated ion channels and NMDA receptors can instead amplify sufficiently concentrated inputs and produce a dendritic spike. Neither summing prescribed electric currents nor adding separate measured EPSPs is an exact universal rule for a branching neuron.[ref]
Thermal boundary resistance describes a temperature drop between the two sides of a material interface carrying heat flux. Efficient thermal conduction within each material does not guarantee efficient heat transfer between them. The solid–helium case is Kapitza resistance; the broader concept also includes solid–solid interfaces. [ref]
Let and be the temperatures extrapolated to the interface from its solid and liquid sides, each treated as internally in thermal equilibrium. For uniform normal heat flux through area , define the finite-drop, area-specific thermal resistance and the resistance of the whole interface by
The macroscopic jump represents an unresolved interfacial region; it is not a claim that one point has two equilibrium temperatures. At nonzero heat flux, the two sides are outside mutual thermal equilibrium. A measured difference between distant thermometers also contains bulk temperature gradients, which must be measured or bounded before assigning all of it to the interface.
An energy balance explains why a temperature jump can coexist with continuous heat flux. For a stationary interfacial region with no local work or heat source,
The first law of thermodynamics therefore requires in a steady state. It does not require . For a heated sample with electrical power , an independently determined outward parasitic loss and no other inputs,
Here is the heater's electric potential difference and its electric current. Subtracting a lead loss means subtracting power before dividing by area; is not the total heating power. Unknown losses and stored internal energy prevent that simple steady inference.
For a one-dimensional comparison, put an interface between two slabs with the same area , positive constant thermal conductivities and lengths . Neglect side losses. Integrating Fourier's law across each slab gives
Thus, for a linear interface with constant , the series result is
These slab formulas are a chosen thermal conduction model, not a bulk transport law for moving liquid helium. If the interface law is nonlinear, substitute its own relation between and into the preceding balance; a single constant resistance cannot describe every load. Increasing bulk thermal conductivity has diminishing benefit when the interfacial drop dominates. Increasing usable contact area reduces the whole-interface thermal resistance if the local interface law and the other conditions remain fixed.
Thermal electrical noise 2026-10-18
Thermal electrical noise is the fluctuating electric potential difference or electric current produced by thermal fluctuations in a dissipative electrical circuit, even without an applied voltage. A resistor at thermal equilibrium is both a source of noise and a sink for electrical energy. Its electrical resistance describes the dissipation, and its absolute temperature sets the scale of the fluctuations. This connects a practical limit on signal-to-noise ratio to statistical mechanics: a warm, unbiased resistor is not electrically silent.
John Bertrand Johnson measured the effect using a vacuum-tube amplifier and thermocouple; his 1928 paper reported agreement with the Boltzmann constant. Harry Nyquist's companion paper calculated the effect from thermodynamics and statistical mechanics.[ref][ref]
Thermal resistance Created 2026-10-14 Updated 2026-10-18
Thermal resistance measures the temperature drop required to drive a given rate of heat transfer. For the steady one-dimensional bar model in thermal conduction,
Here relates the temperature drop to heat flux, while relates it to the rate of heat transfer. The single bar above has and , so its drop drives .
To see why series thermal resistances add, apply Fourier's law in each layer to obtain . With no accumulation or side losses the rate of heat transfer is the same through both, so adding the drops gives . This lets us size layered walls without solving a new differential equation for every layer. The structure matches Ohm's law: temperature difference plays the role of electric potential difference, the rate of heat transfer plays the role of electric current, and thermal resistance plays the role of electrical resistance. [ref]
Thermocouple Created 2026-10-14 Updated 2026-10-14
A thermocouple uses two different electrical conductors and the Seebeck effect to infer a measuring-junction temperature from a voltage and a known reference temperature. The reference material and the reference temperature are distinct choices: B specifies the comparison Seebeck coefficient, while specifies the lower limit of the integral. The two-material experiment in Seebeck effect gives the geometry, sign convention, and calibration limitations.
The useful measurement is a pair: the raw terminal electric potential difference and the thermocouple reference junction temperature. For the A-positive terminal order and homogeneous-wire assumptions of Seebeck effect, write the open-circuit electromotive force as
Here is the thermocouple measuring junction temperature and is the common temperature of the reference connections. The subscript names the measuring end; it need not be hotter. A voltmeter senses the complete connected thermoelectric path through the wires and its leads, in the electrochemical potential convention already described under Seebeck effect. It does not measure an absolute temperature, the individual Seebeck coefficient of A, or an isolated contact electric potential.
Figure 1.
Thermocouple wiring with two copper-lead junctions at a common reference temperature
. Original schematic. The isothermal terminal block contains electrically separate A–Cu and B–Cu transitions and a local temperature sensor. Both homogeneous copper leads end at the same meter-input temperature , so their thermoelectric contributions cancel. The displayed is calculated from a stipulated constant difference of Seebeck coefficients, not measured data or a calibration of actual materials. Details.
Thermoelectric offset 2026-11-05
A thermoelectric offset is an unwanted electric potential difference associated with Seebeck effect responses in a measurement circuit. Dissimilar conductors at different junction temperatures can generate a signal even when the intended electrical input is absent. Keithley's handbook discusses these offsets as a major limitation in low-voltage and low-resistance measurements.[ref]
For a simple two-material circuit, a useful model is
where the Seebeck coefficients depend on conductor material and temperature. With a stipulated constant difference and junction-temperature difference , the offset is . These are teaching inputs, not coefficients assigned to a particular real connector pair.
That small offset can dominate an intended signal. For an original resistor tested at , the wanted drop is also . An additive offset of the same sign doubles the indication to and gives an apparent if it is ignored. Reversing the current produces readings and in this model; their half-difference recovers the wanted .
Polarity reversal measurement cancels the unchanged offset, not every temperature effect. Thermal changes during the cycle can leave a residual, while current-induced heating can alter the resistor itself. The handbook therefore connects reversal timing with thermal stability.[ref]
An offset investigation records connector materials, junction temperatures, warm-up and handling, and compares readings before and after reversal. Reducing temperature gradients and avoiding unnecessary dissimilar-metal connections can reduce the generated signal. Keep residual correction uncertainty in the measurement result. A thermoelectric offset and random thermal noise have different roles in the measurement model; they are not interchangeable merely because both involve temperature.
Thermopile Created 2026-10-14 Updated 2026-10-18
A thermopile connects multiple thermocouples in series to turn a temperature difference into a larger electrical signal. Absorbed thermal radiation can heat its sensing junctions while reference junctions remain cooler; the signal depends on the thermal and optical design.
A thermopile is an array of thermocouples connected as a series circuit with their electromotive forces adding in the chosen terminal order. It measures a collective temperature difference through the Seebeck effect. An open-circuit electric potential difference requires no externally supplied electric current through the array: a high-input-electrical resistance voltmeter reads the signal. The heat that maintains the junction temperature difference still comes from somewhere, such as absorbed electromagnetic radiation.
In a membrane detector, an absorbing film heats the measuring junctions while reference junctions lie on the surrounding support. Actual junction temperatures can differ across the membrane.[ref] This converts difficult-to-observe heat transfer into an accessible electrical signal; the series connection combines many small contributions without requiring every thermocouple to have a separate meter.
PASCO's documented lamp experiment connects a TD-8553 thermopile sensor to a millivoltmeter and places it level with a lamp filament along a meter stick. Lamp and detector axes are aligned. With the lamp off, readings at several positions establish an average ambient thermal radiation background. With the lamp on at a fixed supply setting, detector readings at different distances are compared after background subtraction. Between readings, a reflective shield prevents the detector warming; its shutter also protects the reference junction when idle. Moving the shutter can move the sensor, so fixed geometry matters. The manual's lamp limits must be followed.[ref]
This protocol tests whether the background-corrected electric potential difference approximately follows the inverse-square law over a suitable distance range. It is a relative electromagnetic radiation measurement; those readings alone do not calibrate absorbed power in watts. The manual treats the filament as an approximate point source.[ref]
For an absolute calibration, independently known absorbed power and a monitored reference temperature would be needed. A useful additional control is to repeat a fixed detector position before and after a distance sweep: disagreement reveals possible drift. These additions test the measurement chain rather than assuming that background subtraction fixes every error. A finite source, changing illuminated area, reflections, changing reference temperature, and insufficient settling can alter the measured dependence. In particular, the time constant in thermopile thermal response explains why a quick reading and a settled reading may differ. The detector infers its own absorber temperature difference; inferring the source's temperature additionally requires its emissivity, optical geometry and an appropriate thermal radiation model.
Thermopile series voltage 2026-10-18
Use the A-positive terminal order of Seebeck effect for each thermocouple. Its thermocouple measuring junction has temperature and its reference connections have temperature . Define the difference of Seebeck coefficients as . Connect the B reference end of one thermocouple to the A reference end of the next at a common local temperature, so the terminal electric potential differences add:
The first A reference terminal is the positive meter input; the final B reference terminal is the negative input. Following this connected path and adding the individual Seebeck effect integrals proves the result. Matched meter leads with common endpoint temperatures cancel as in an isothermal terminal block. The manufacturer's sum formula also allows unequal individual contributions.[ref]
Figure 1. . Original idealized wiring, showing three of thermocouples. Each A leg rises from reference temperature to absorber temperature , and each B leg returns. B-to-A connections at join adjacent pairs; the thermally shared absorber and support do not short the electrically distinct junctions. A-positive and B-negative meter connections match the Seebeck effect convention. Arrows indicate absorbed electromagnetic radiation and escaping heat, not electric current. Details.
If all pairs share and the same nearly constant difference of Seebeck coefficients throughout that temperature interval, then
This is the pair's relative Seebeck coefficient, not either material's individual coefficient or a universal device constant. As an original constructed example, choose , and . Each thermocouple contributes and
Reversing the meter connections changes the sign. Exchanging and reverses the integrals and hence the electromotive force; this reversible sign response does not make a detector with heat conduction a reversible thermodynamic process. Reversing the wiring of one pair instead gives , because one contribution is subtracted rather than added. For this example the result is , and at equal junction temperatures every contribution vanishes.
The open-circuit condition matters. If the array's total electrical resistance is and the meter input has electrical resistance , the elementary voltage divider model gives . Thus is needed to suppress voltmeter loading. Appreciable electric current also permits Joule heating and the thermoelectric heat transfer to disturb the assumed junction temperatures.
To determine the Thévenin resistance, remove the external electrical load and set each independent electrical source to zero in the circuit model. A zero ideal voltage source enforces zero electric potential difference, so replace it by a short connection. A zero ideal current source enforces zero electric current, so replace it by an open connection. Retain every resistor, including any explicitly modeled supply electrical resistance. Turning an actual power supply's front-panel control to zero is not evidence that it physically becomes an ideal wire.
Retain every dependent electrical source and its controlling variable: its response to an electrical test source is part of the network's electrical resistance. Impose terminal voltage with an electrical test source and calculate entering the suppressed network at . For a nonzero test yielding a finite ratio,
Alternatively inject a known entering electric current and solve for . The test electric current is opposite to the delivered-current convention of the original Thévenin terminal response. [ref]
For an original illustration, put a positive resistor across and a dependent electrical source in parallel that injects electric current from toward , where has units of electrical conductance. Its control is the same terminal voltage . Kirchhoff's current law gives
With and , a test draws , giving . Removing the dependent electrical source would falsely give . With , the model instead has ; with it draws zero test electric current for any imposed voltage and has no finite ratio. An active physical realization requires a supply and has a limited operating range.
For a finite nonzero and a well-defined short-circuit response, . Thus is usable when . A source-free positive resistor has both and , so this quotient cannot reveal its electrical resistance; an electrical test source can.
Thévenin's theorem Created 2026-10-13 Updated 2026-10-14
Thévenin's theorem replaces the terminal behavior of a linear resistive circuit by an ideal voltage source in series with a Thévenin resistance, whenever its terminal electric potential difference is a well-defined affine function of the delivered electric current. Fix terminals , write , and take positive out of the network at into the electrical load, returning through . Then
The open-circuit voltage is the intercept at ; is the slope. Thus two parameters predict what happens when many different electrical loads are connected. The Wheatstone bridge detector loading calculation uses precisely this replacement to find the detector reading even when the bridge's two voltage dividers interact through its detector.
For example, a ideal voltage source with above and below a voltage divider junction supplies and at that junction relative to the lower terminal. Attaching a electrical load reduces its voltage to and draws . The equivalent explains why an unloaded divider ratio alone cannot predict a loaded output.
Figure 1.
A 12 V voltage divider and its 8 V Thévenin equivalent feed the same load
. Original calculated example: the left circuit has and divider arms; the right circuit has an ideal voltage source and series Thévenin resistance. Both use and delivered electric current from into the same electrical load. Dashed boundaries identify what is replaced. Source. Details.
The equivalence concerns the chosen terminals, including the power delivered there. It does not identify internal branch electric currents or internal Joule heating. At open circuit the original divider still draws from its supply, while the equivalent's series branch carries no electric current. [ref]
Thomas M. Blooming 2026-11-05
A useful technical question is why improving fundamental displacement power factor can alter the response to other harmonic components. In an original lossless parallel LC circuit, the admittance is
Its reactive terms cancel at the resonant frequency
For stipulated and , . Doubling moves it to about . A correction component chosen for one operating frequency has therefore changed the network at other frequencies as well.
In this ideal parallel model the impedance diverges at resonance; a finite imposed harmonic electric current would demand an unbounded electric potential difference, signaling the ideal model's limit. Real losses and other network elements bound and shift the response. A proposed bench test uses a small known drive and sweeps frequency with and without the extra capacitor, recording both current and potential difference. It tests the frequency-dependent circuit rather than inferring behavior from the fundamental cosine alone.
The calculation is an original illustration of the network question, not an experimental result attributed to Blooming. His joint paper with Daniel J. Carnovale supplies the application context: component choice and operating conditions must be considered together. A correction that looks favorable in a single-frequency power factor calculation is not, by that fact alone, characterized across the full waveform.
Thomson charge-to-mass experiment Created 2026-10-18 Updated 2026-10-20
The Thomson charge-to-mass experiment infers the magnitude of an electron's charge-to-mass ratio by combining electric and magnetic deflection of cathode rays. The central idea is to determine speed separately from magnetic curvature: a known speed turns the observed gyroradius into a measurement of .
In 1897, J. J. Thomson used two grounded slits in an evacuated glass tube, then aluminium plates long, wide and apart. A battery supplied their electric potential difference. Deflected cathode rays produced a phosphorescence patch on the glass; an external scale and movable luminous pointer recorded its position in darkness. Greater evacuation reduced gas electrical conductivity that screened the electric field; reversing plate polarity reversed deflection. External coils supplied the magnetic field, calibrated by induction against larger coils. He adjusted equal electric and magnetic deflections. [ref]
His comparison included air, hydrogen, carbon dioxide, and aluminium versus platinum cathodes, supporting a common carrier. He explicitly noted uncorrected magnetic bending outside the plates. His tables give , the reciprocal of the magnitude used here. The inferred ratio alone could not separate electric charge from mass. [ref]
To connect this readout with the Lorentz force, derive a simple nonrelativistic model in modern SI notation. Let the uniform deflecting region have length , followed by a field-free drift of length . Assume a narrow speed distribution, small deflection angles, negligible collisions, and matching electric and magnetic field profiles. For an electron with speed , the electric acceleration has magnitude , the transit time is approximately , and the subsequent drift adds exit transverse velocity times . Thus the displacement magnitudes measured separately with only electric field or only magnetic field are
The electric expression follows from constant transverse acceleration; the magnetic expression uses its small-deflection approximation. Equal displacement magnitudes then give
This is an ideal derivation of the comparison principle, not a numerical reanalysis of the historical tube. Different exterior magnetic field profiles invalidate cancellation of the common geometrical factor. The comparison determines through deflection and the known apparatus dimensions; it does not require a downstream semicircle.
For a second, deliberately different teaching geometry, combine a velocity selector with a separate region containing only a uniform magnetic field perpendicular to the selected velocity. Here belongs to the velocity selector, while belongs to the analyzer: they need not be equal. The magnetic Lorentz force supplies the centripetal acceleration, so
If the analyzer turns the beam through a semicircle before it hits a screen in the entry plane, the separation between entrance and impact is the diameter: . For a shorter observed arc, the screen displacement is not generally a radius; fit the appropriate circle geometry. This two-stage velocity selector and curvature apparatus is an original ideal teaching model, not a claim that Thomson's Fig. 2 used a separate selector and semicircular analyzer.
Figure 1.
Inferring an electron's charge-to-mass ratio from selected speed and magnetic curvature
. Original ideal analyzer with zero electric field, magnetic field out of the page, and negative electric charge bending upward. The semicircle has screen separation . All numerical inputs are stipulated teaching values, not historical measurements. The magnetic field differs from the upstream velocity selector magnetic field . Details.
For a worked example, stipulate , , , and . The selected speed and inferred charge-to-mass ratio magnitude are
The SI units provide an independent check: and , because . The charge-to-mass ratio of the electron is negative; this calculation gives its magnitude. The bending direction gives the sign of the electric charge once the magnetic field direction is known. Scaling both and by the same positive factor preserves every displayed trajectory, so an independent electric charge measurement is required to determine mass separately.
The curvature formula assumes nonrelativistic momentum . At higher speeds, the relativistic cyclotron orbit gives , hence , where is the Lorentz factor; the ideal straight-through selection still follows from vanishing Lorentz force. The stipulated speed is about times the speed of light, making about . For this example the nonrelativistic approximation is adequate, but no massive particle can be selected at . Finite slit widths, collisions with residual gas, uncertain magnetic field calibration, and fields outside the ideal boundaries limit a real inference; repeat at several selected speeds and analyzer strengths to test consistency of rather than trusting one spot position.