Thermal noise measurement 2026-10-18
MIT's laboratory guide mounts resistors on an aluminum box beneath a metal beaker shield, with short twisted leads. Its SR560 amplifier uses nominal gain before a Krohn-Hite – band-pass filter; an oscilloscope reads root mean square voltage. Calibration sweeps an attenuated sinusoid and measures the actual gain . Students alternate the resistor and a short circuit, subtracting squared readings , and disconnect the ohmmeter during noise acquisition. Lead and input capacitance enter the gain-squared integral. With settings unchanged, varying electrical resistance or temperature tests the predicted mean square. The guide prescribes repeated readings and warns against averaging noise waveforms to zero. This is a documented teaching protocol, not a supplied dataset of measured outcomes.[ref]
Johnson Noise and Shot Noise: The Determination of the Boltzmann Constant, Absolute Zero Temperature and the Charge of the Electron by MIT Department of Physics. MIT Department of Physics, Johnson Noise and Shot Noise, pp. 5–9: equation (13), apparatus §III, calibration §IV.1, Figure 5, and shorted-input subtraction equation (20)
The subtraction requires care: shorting the input changes the source electrical impedance. An amplifier's input current noise can therefore produce different voltage noise in the two configurations; a shorted baseline alone does not remove that contribution. Gain drift, interference and insufficient observation time also limit the inference. These are limitations of interpreting the measurement, not corrections that can be inferred from the nominal signal bandwidth alone. In an independent analysis one would compare the measured difference withwhere represents the measured shunt capacitance and excludes that separately modeled shunt. If calibration already includes the same shunt response, applying the denominator again counts the attenuation twice. The thermal noise worked example and both original figures illustrate ideal models; they claim no measured agreement or measured value of the Boltzmann constant.
Thermal noise spectral convention 2026-10-18
Model an ideal resistor of constant electrical resistance at uniform absolute temperature by its Thévenin equivalent: a zero-mean random voltage source in series with a noiseless . In the classical range its one-sided, open-circuit voltage power spectral density, per hertz, iswhere is the Boltzmann constant. Thus a positive-frequency interval of width contributes to the mean square voltage. This is approximately white noise only where the electrical resistance is effectively constant and , with the Planck constant. The ideal constant spectrum cannot describe arbitrarily high frequencies.[ref]
For a real voltage, an equivalent two-sided power spectral density is over signed frequencies. With a real linear time-invariant system of frequency response , the same output mean square isAngle brackets denote an expected value; for this zero-mean noise the mean square is its variance. Do not integrate over both signs of frequency: that counts the same fluctuations twice. All integrals here use frequency in hertz, not angular frequency . The amplitude spectral density is in , whereas the root mean square voltage requires a specified measurement signal bandwidth.
Thermal noise worked example 2026-10-18
For an original hypothetical calculation, stipulate , , and an ideal rectangular measurement signal bandwidth . Using givesA matched electrical load receives root mean square from the source resistor, giving . These are stipulated model predictions, not laboratory measurements. Increasing raises the open-circuit voltage noise but does not increase the matched available power. Restricting the measurement signal bandwidth reduces root mean square noise as its square root; it improves signal-to-noise ratio only if the desired signal is preserved.
Thermistor 2026-10-18
A thermistor is a temperature-sensitive resistor used as a resistance thermometer. Its calibrated electrical resistance supplies a temperature indication; probe heat capacity and unwanted thermal conduction can affect its response and immersion error.
Thévenin divider example 2026-10-14
In the pictured original linear resistive circuit, the ideal voltage source keeps its upper node at relative to . Let connect that node to , and connect to . With the external electrical load removed, the voltage divider givesTo find the Thévenin resistance, Thévenin source suppression replaces the ideal voltage source by a wire. Both resistors now join to in parallel, givingThis is the electrical resistance looking into the original network with its independent electrical source suppressed; the external electrical load is excluded.
An independent check uses Kirchhoff's current law at , without suppressing anything:The Thévenin terminal response thus follows directly from the original topology. Shorting to in this ideal calculation gives : the lower resistor has zero voltage and the upper resistor limits the electric current. All numerical values here and in the figures are stipulated model values, not laboratory data.
Thévenin measurement experiment 2026-10-14
An authored teaching experiment uses an adjustable steady-voltage supply, a digital multimeter, fixed resistors, and a potentiometer or resistance decade box. Its original circuit uses a supply and , , and resistors; the student compares and electrical loads. The readout is load voltage, recorded against prediction and deviation. The student then removes the electrical load to measure the open-circuit voltage, disconnects the supply and substitutes a wire to measure the Thévenin resistance with the multimeter's resistance mode, and restores the supply for an independent method: adjust the variable electrical load until the voltmeter reads half the unloaded voltage. Finally the student builds the equivalent and repeats both load measurements. Its tables are blank recording forms, not reported observations. [ref]
Laboratory Manual for DC Electrical Circuit Analysis by James M. Fiore. Laboratory Manual for DC Electrical Circuit Analysis by James M. Fiore, version 1.4.3, experiment 11, printed pp. 52–55: Equipment, Procedure 1–10, Tables 11.1–11.3
The half-voltage inference assumes negligible voltmeter loading and positive . A finite voltmeter input electrical resistance actually gives an apparent unloaded readingWhen the same voltmeter remains connected across a variable electrical load , the network sees . Setting its reading to , rather than to the true , givesThus the uncorrected half-reading method underestimates positive . In the original example, a stipulated gives and half-reading load , instead of . These are model predictions for a deliberately loading meter, not the specification or observed readout of the source experiment's instrument.
Finite readings can also estimate the terminal line without a physical short. For two distinct load settings with corrected delivered electric currents and terminal voltages ,If the voltmeter remains across each electrical load, the delivered electric current is , including the meter branch. Omitting it biases the inferred slope.
Useful additional controls are to measure each resistor separately before assembly, verify terminal polarity, repeat an earlier load setting to detect supply drift, and compare a third setting with the inferred Thévenin terminal response. These are proposed controls, not reported outcomes of the source experiment. Closely spaced electric currents make the slope estimate sensitive to voltage resolution and measurement error; widely separated settings may trigger source current limiting or Joule heating that changes electrical resistance. Lead and contact electrical resistance, meter input uncertainty and rounding limit the inference. An ohmmeter injects its own test electric current; its reading on a powered network is not the suppressed-network ratio. Measurements with independent sources physically removed do not characterize an active dependent electrical source whose control or supply has also been disconnected.
Thévenin resistance 2026-10-14
The negative slope of the Thévenin terminal response with delivered electric current . Thévenin source suppression determines it from the ratio of test voltage to entering test electric current. It need not represent a physical positive resistor inside the original network.
Thévenin source suppression 2026-10-14
To determine the Thévenin resistance, remove the external electrical load and set each independent electrical source to zero in the circuit model. A zero ideal voltage source enforces zero electric potential difference, so replace it by a short connection. A zero ideal current source enforces zero electric current, so replace it by an open connection. Retain every resistor, including any explicitly modeled supply electrical resistance. Turning an actual power supply's front-panel control to zero is not evidence that it physically becomes an ideal wire.
Retain every dependent electrical source and its controlling variable: its response to an electrical test source is part of the network's electrical resistance. Impose terminal voltage with an electrical test source and calculate entering the suppressed network at . For a nonzero test yielding a finite ratio,Alternatively inject a known entering electric current and solve for . The test electric current is opposite to the delivered-current convention of the original Thévenin terminal response. [ref]
Thevenin and Norton Equivalents, University of Houston teaching notes. Thevenin and Norton Equivalents, pp. 5–7, “Test Source Method for RTH” and Notes: suppress independent sources, retain dependent sources
For an original illustration, put a positive resistor across and a dependent electrical source in parallel that injects electric current from toward , where has units of electrical conductance. Its control is the same terminal voltage . Kirchhoff's current law givesWith and , a test draws , giving . Removing the dependent electrical source would falsely give . With , the model instead has ; with it draws zero test electric current for any imposed voltage and has no finite ratio. An active physical realization requires a supply and has a limited operating range.
For a finite nonzero and a well-defined short-circuit response, . Thus is usable when . A source-free positive resistor has both and , so this quotient cannot reveal its electrical resistance; an electrical test source can.
An electronic comparator registers a pulse only if its input reaches the chosen threshold. For an initially uncharged capacitor driven through an electrical resistance , a short rectangular pulse may end before that happens. The resulting threshold-crossing time of a finite rectangular pulse through an RC load depends on threshold and pulse duration, as well as the time constant ; it is not determined by group delay alone.
Take a positive input electric potential difference for , zero input outside that interval, and output across a capacitance . Include the source's effective series electrical resistance in . The initial condition is . Kirchhoff's voltage law and the capacitor current relation give the first-order linear differential equationThe output is a continuous function and reaches its maximum at the pulse's falling edge:The input jumps there, but an ideal capacitor's stored electric charge cannot change discontinuously under the finite currents of this model.
Choose a fixed threshold with . Solving the rising exponential function using a natural logarithm givesIf , the output never reaches the threshold. At , it touches the threshold only at its peak; the ideal time spent strictly above threshold is zero. A nonzero high interval in an ideal non-inverting electronic comparator requires . This is RC pulse-width discrimination: different input durations can give a missing pulse or a finite output pulse even when their input heights are equal.
For , solving the falling exponential decay givesHere is the time above threshold for an RC-filtered rectangular pulse, before any electronic comparator switching dynamics. It is not generally the input duration . Just above , differentiation gives and hence to first order; a half-height threshold gives slope two at the detection boundary.
For an original numerical example, take , , , and , so . A input peaks at only and is rejected. A input peaks at and givesThese are model calculations, not recorded instrument traces.
A threshold near the asymptotic input height is also especially sensitive to noise and threshold measurement uncertainty. Holding the absolute input height and fixed, the threshold timing sensitivity of an RC step response isFor the same , model, a effective threshold perturbation gives approximately of timing change at , but at , by first-order uncertainty propagation. The rectangular pulse must still last long enough to reach the selected threshold; changing together with is a different sensitivity calculation.
A bench test uses a pulse generator and an oscilloscope to record both the applied electric potential difference and the capacitor output. Sweep while keeping and the actual threshold fixed, and allow enough time between pulses for the measured initial output to be negligible at the desired precision. Include probe and comparator-input capacitance in . MIT's laboratory measures RC decay with a capacitor, a resistor and square-wave excitation; that gives a directly measurable component-value time constant.[ref]
Laboratory 11: Sinusoidal Steady State Response of RC and RL Circuits by MIT OpenCourseWare. Printed pp. 1–2, component values and decay/phase measurements
The pulse-duration sweep proposed here extends that decay measurement to a threshold observation. A real electronic comparator's input offset voltage, hysteresis and finite switching time must be separated from the ideal RC crossing times; a Schmitt trigger uses different rising and falling thresholds. Transistor small-signal amplifier 2026-10-18
An original teaching model exposes the roles of input loading, output loading and the supply. Choose a small-signal model with positive input electrical resistance , transconductance , and output electrical resistance . Its controlled output current source draws from the output node toward the reference node. This chosen sign gives an inverting voltage gain; it is not the historical contact circuit's sign convention.
Assume a fixed operating point, negligible reverse coupling, a frequency range where coupling capacitors pass the signal, and negligible other capacitances and transit delays. A collector resistor connects the output to a steady ideal supply ; an external electrical load is coupled through a capacitor, so it draws no direct current. The input source has series electrical resistance . All voltages below are small departures from the operating point. An ideal fixed supply has zero incremental voltage and therefore becomes the reference node in the small-signal model.
Define and , where . Input voltage division and output Kirchhoff's current law giveConsequently the port voltage gain, overall source-to-output voltage gain, and load current gain magnitudes areThis current gain uses load electric current, not all the controlled-source electric current. It is also a different port definition from the historical emitter-to-collector current gain. Larger attenuates the input; smaller attenuates the output.
For a sinusoid input signal, use root mean square voltages. The power gain from accepted input signal power to useful load power isUnlike , this tends to zero as either or . Differentiation givesThus matching the output electrical load maximizes delivered power in this unilateral resistive model. For fixed source voltage, input loading multiplies by ; the accepted-input power gain above excludes the loss in .
Choose , , , and . Then . With and root mean square, the input is and the inverted output has magnitude root mean square. Hence and : . These are calculated values of the chosen model, not historical measurements.
With the same parameters but , while . At , while . Neither current gain nor voltage gain alone establishes power gain.
For the direct current load line in the figure, choose , and , consistent with . Locally extend the model as . With the external electrical load isolated at direct current, its intersection with is . Keeping small compared with the available voltage headroom is essential; extrapolation to arbitrarily large signals would be unphysical.
At the chosen operating point the collector supply delivers : is dissipated in and in the output device. Under a small signal, that energy flow is redistributed to provide load power. The incremental controlled current source hides the supply's steady energy flow; it does not create energy. A real complete amplifier also needs its input biasing network and has further losses. This calculation establishes neither its total efficiency nor a universal law for point-contact transistors.
Tunnel-diode load-line stability 2026-10-18
A current-voltage characteristic determines possible steady operating points; it does not alone determine their linear stability. Consider an ideal voltage source feeding a tunnel diode through a resistor , with a positive constant capacitance across the junction. Assume a quasistatic device relation and neglect inductance, transit delays, noise and heating. Kirchhoff's current law gives the original one-state modelA steady operating point satisfies : the device curve intersects the descending supply line. This is the source-side counterpart of a resistive load line. A small perturbation obeysThus the equilibrium point is locally attracting if and unstable if the inequality reverses. Equality requires higher-order analysis. Even on a negative differential resistance segment, a sufficiently small supply electrical resistance can stabilize this model. The assumption about the electrical circuit matters: an inductive or delayed circuit has additional state variables and may behave differently.
Choose an original toy forward characteristic, with no fitted device parameters:where , and . For every , , so this entire forward curve absorbs positive total power. NeverthelessThe model therefore separates negative differential resistance from negative total . The corresponding peak and valley are at approximately and ; these voltages deliberately differ from the historical peak.
With and , the supply line is . The intersection equation factors exactly:The three operating points are , and . Their values of are respectively , and . The outer two attract nearby trajectories; the middle one repels them. This is bistability in the specified one-state electrical circuit.
For the second panel, choose and . Now andThere is exactly one real operating point, again . Here , despite the device's own slope . With , the perturbation decays with time constant ; the unstable middle point of the first panel has growth time .
The one-state autonomous model supports switching between attracting operating points after a perturbation or parameter change; it cannot produce a nonconstant periodic orbit. A proposed oscillator needs additional dynamics. This limitation is useful: a load-line intersection establishes a possible steady reading, the slope test establishes local attraction in a specified model, and neither calculation alone predicts an oscillation frequency for a real tunnel diode.
Two-current resistor model 2026-10-18
Consider two identical magnetic layers separated by a nonmagnetic layer, between reservoirs that impose the same terminal electric potential difference on both spin channels. Neglect spin-flip scattering and assume each layer obeys Ohm's law. In a magnetic layer, define positive channel electrical resistances . Let the spacer contribute to each channel. These are circuit parameters, not measured iron or chromium resistivities.
For parallel layer magnetizations, one channel meets and the other . For opposite layer magnetizations, each meets one , one , and the spacer. The two channels share the same terminal electric potential difference and run in parallel. Writing givesThe inequality is algebra, given the specified network. It shows how a difference between spin-channel responses can yield a difference between magnetic configurations even though all the constituent resistors are ohmic.
For chosen , , , the parallel channels have total electrical resistances and , while the opposite-alignment channels each have . Thus and . At a common terminal electric potential difference , the total electric currents are and , respectively.
Voltage divider Created 2026-10-13 Updated 2026-10-14
A voltage divider uses two resistors connected in series to obtain a fraction of an applied electric potential difference. Let the upper electrical resistance be , the lower one , and the input be relative to a common electrical reference potential. The output is the junction's electric potential difference relative to that same reference, across . The familiar ratio assumes zero output electric current: no external electrical load draws from the junction. In a steady direct current model with fixed resistors obeying Ohm's law and an ideal voltage source,Here is the open-circuit voltage; correspond to in the header formula. With no junction branch, Kirchhoff's current law makes the same electric current pass through both resistors, and Ohm's law gives the two voltage drops. For , division gives ; if , the predicted output is zero but this ratio is undefined.
An original stipulated example has and . With zero output electric current, and . An attached electrical load instead gives ; a load gives . These are exact model predictions, not measured readings or specifications of a particular multimeter or oscilloscope.
The same voltage divider has three different predicted outputs as the attached load changes
. Original circuit and readout comparison for ideal input and two resistors. Each finite connects across ; the displayed numbers are model predictions with ideal readout, not experimental data. Source. Details.The divider is useful for scaling a voltage or converting a change in a sensor's electrical resistance into an electric potential difference. Its beauty is also its trap: multiplying both electrical resistances by the same positive factor preserves the unloaded ratio, but changes the effect of any fixed electrical load. A divider therefore supplies a predictable ratio under specified loading conditions; it is not a source that maintains that voltage for arbitrary output electric currents. A Wheatstone bridge compares two divider junctions, while Thévenin's theorem describes the divider's response to many different loads.
Voltage divider teaching experiment 2026-10-14
Southern Illinois University's ET 304A guide, Lab 4: Voltage Measurements and Meter Loading Effects, documents an instructive test: build equal-arm voltage dividers on a supply, then measure across the lower arm with a digital multimeter, analog multimeter, and oscilloscope. Starting with two resistors, repeat with equal pairs from to . It requires separate recorded readings, unloaded predictions, and predictions including each instrument's input electrical resistance. The guide obtains meter resistances from specification sheets and scope resistance from the input-panel marking. Equal ratios control the unloaded target while changing susceptibility to voltmeter loading. The provided tables are blank: the guide specifies a procedure, not measured outcomes.[ref]
Preparation and accuracy checks are made concrete by Berkeley's Lab 1: Introductory Experiments and Linear Circuits I. Its different divider uses nominal and resistors and a supply on a breadboard. Measure isolated resistors first, record actual supply voltage, recalculate with these measured values, then record the junction voltage with the digital multimeter. It explicitly compares actual values with resistor tolerance and the final voltage with a range-dependent accuracy bound from the instrument manual. This is an uncertainty check, not an independent measurement calibration.[ref]
For a controlled comparison, additionally record the selected instrument range, probe factor, and input coupling; connect each instrument separately to the same electrical reference potential, and monitor the input rather than treating the supply label as an exact voltage. These are proposed controls for interpreting the documented procedures. A voltage indication and a resistance indication from the same digital multimeter do not independently validate its measurement calibration; a traceable reference comparison would be needed for that. Resistor tolerance describes component variation, while measurement uncertainty describes what is known about measured values. Using nominal arms alone can confuse mismatch with loading: equal nominal arms each within one-percent tolerance can give unloaded ratios from to .
The inference to test is specific: once actual arm values, input voltage, and meter input electrical resistance are accounted for, the readout should approach the loaded voltage divider prediction within the remaining measurement uncertainty. A discrepancy can instead reflect contacts, changing temperature, source droop, or an input that is not a fixed passive resistor. A source with positive series electrical resistance can be modeled by replacing with only when denotes its ideal internal voltage; when the actual voltage across the divider is measured, that terminal value is already . During settling, or with appreciable input capacitance and changing signals, the steady direct current calculation is insufficient. Neither institutional procedure supplies measured values for the original example above.
Voltmeter loading 2026-10-14
Voltmeter loading is the change in an electric potential difference caused by the electric current drawn by the measuring voltmeter.
For a loaded voltage divider in steady direct current, a voltmeter connected across the lower resistor places its finite input electrical resistance in parallel with the lower arm's electrical resistance and any intended electrical load of electrical resistance . With positive, fixed electrical resistances, an upper resistor of electrical resistance , and an ideal voltage source supplying electric potential difference , Kirchhoff's current law and Ohm's law giveHere is the connected circuit's electric potential difference across the voltmeter; omit if there is no intended electrical load. The parallel connection and need for large input electrical resistance are standard voltmeter operating principles.[ref]
10.4 Electrical Measuring Instruments. §10.4, Measuring Voltage with a Voltmeter: parallel connection and large input resistance
Voltmeter loading is a bias relative to the target electrical circuit with the voltmeter absent and any intended electrical load still present. Voltage divider loading error instead compares the attached-load output with the wholly unloaded output. An accurate readout of , supported by measurement calibration, can still differ from either target: calibration accuracy concerns the indication of the connected electric potential difference, whereas voltmeter loading changes that electric potential difference itself.
Wheatstone bridge Created 2026-10-13 Updated 2026-10-20
The Wheatstone bridge has four resistor arms and two diagonals. Here the supply holds node at constant electric potential difference relative to node , our electrical reference potential. The left path is ; the right path is . The unknown is , and is adjustable. A voltmeter or galvanometer connects to . We define its positive reading as ; exchanging its leads reverses the sign. All four electrical resistances are positive, the supply is ideal, and the calculation describes steady electric currents at fixed temperature.
Four labeled Wheatstone bridge arms and the equivalent circuit seen by the detector
. The supply spans ; the detector spans and reads . The right panel uses Thévenin's theorem to replace the bridge by its open-circuit electric potential difference and a series electrical resistance. Source. Details.Charles Wheatstone described the instrument in his 1843 Bakerian lecture while explicitly crediting Samuel Hunter Christie. The account from King's College London's collection identifies that attribution; the familiar name should not be read as an assertion that Wheatstone alone originated the bridge.[ref]
Wheatstone Collection by King's College London. Wheatstone Collection, section “Wheatstone's contributions to electricity”: 1843 lecture and credit to Samuel Hunter Christie
Wheatstone bridge detector loading 2026-10-14
A real voltmeter has finite input electrical resistance ; a galvanometer also has a finite winding electrical resistance. Away from balance, its electric current changes both intermediate electric potentials. This is voltmeter loading when the detector is a voltmeter. Model the detector as a passive resistor, with no offset or injected electric current. Thévenin's theorem supplies the full response without pretending the connected bridge remains two independent voltage dividers.
With the detector removed, the equivalent source is . Replace the ideal supply by a wire to calculate the source electrical resistance seen between : nodes merge, making parallel and parallel. ConsequentlySince the attenuation factor is strictly positive for , the null remains . A smaller detector electrical resistance reduces the measured electric potential difference off balance but does not shift the ideal null. Its electric current sensitivity instead depends on ; detector gain and resolution also matter in deciding how closely a null can be located.
Finite detector resistance reduces bridge voltage sensitivity while preserving the null
. Calculated curves use and . All cross zero at ; the inset resolves their different slopes. These curves are a model, not measured data. Source. Details.In the plotted example, gives and . A detector with instead reads . Using that loaded reading in the unloaded voltage divider formula would underestimate the deviation of from . Balancing the bridge avoids this particular systematic measurement error.
The local derivative makes the sensitivity explicit. For and , the first-order Taylor expansion isAt the plotted null, the open-circuit slope is , compared with for . Increasing the supply improves this ideal sensitivity but also increases Joule heating. A finite source electrical resistance requires recomputing ; the displayed parallel-pair expression assumes an ideal supply.
Wien bridge 2026-10-18
An alternating-current electrical circuit comparing a parallel resistor-capacitor arm with a series resistor-capacitor arm. Let the upper-left arm have electrical impedance , the lower-left arm , and the upper-right and lower-right arms have electrical resistances . For input between the upper and lower nodes and an unloaded difference measurement between the arm junctions, voltage divider balance requires . Separating real and imaginary parts givesThe balance angular frequency is positive for positive components. Equal and require and . Reversing which reactive arm is upper changes the divider ratios, so the connections must always be specified.
Wirewound resistor Created 2026-10-25 Updated 2026-11-05
A wirewound resistor uses resistive metal wire wound on an insulating former. Suitable alloys and heat-resistant construction provide stable electrical resistance and substantial electrical dissipation; parasitic inductance and interturn capacitance limit the frequency range over which it behaves as a pure resistor.
Zero-input response 2026-11-05
The zero-input response is the output due to a system's initial internal state when its externally applied input is set to zero. It describes memory left by earlier excitation. For a linear time-invariant system, linearity separates this from the zero-state response due to the subsequent input.
For constant matrices in , , setting and givesThe matrix exponential solves the homogeneous state equation. With an arbitrary input, the complete solution adds the zero-state response:A zero initial output alone does not establish that the whole state is zero.
For an RC circuit with capacitor difference and no applied source, , so . The capacitor energy falls as ; the resistor receives the dissipated energy. The primary MIT lecture explicitly distinguishes the capacitor's initial state, zero external input and zero initial state.[ref]
State and Memory by Anant Agarwal and Jeffrey Lang. PDF pages 2–6, RC memory and zero-input/zero-state decomposition
At a time constant and , the modeled difference after two seconds is . Zero input has not meant zero output or zero stored energy. A direct experiment charges the same capacitor to different known initial differences, removes the charging source and records the decay across a fixed resistor. The amplitudes should scale with while the normalized decay remains the same in the linear model.
A zero-input response need not decay in every system: an ideal undamped oscillator retains its initial motion, and an unstable homogeneous system can amplify a nonzero initial state. The transfer function describes the zero-state input-output map, so its product with a zero input cannot represent a separate nonzero initial-state contribution.