Aharonov-Bohm effect Created 2026-09-28 Updated 2026-10-20
The Aharonov-Bohm effect is the phase acquired when a charge encircles magnetic flux , even when the magnetic field vanishes along the charge's path.
In the magnetic Aharonov-Bohm effect, a coherent electron wave takes two routes around inaccessible magnetic flux. Recombination converts their relative wave phase into displaced interference fringes. In 1959, Yakir Aharonov and David Bohm proposed a shielded solenoid geometry and identified the obstruction to removing the magnetic vector potential throughout the accessible region.[ref]
Significance of Electromagnetic Potentials in the Quantum Theory by Yakir Aharonov and David Bohm. 1959, §2, pp. 486–487, Fig. 2 and reflecting-barrier discussion
Use International System of Units, electric charge , and magnetic minimal coupling . Let run from the same source to the same detector point . The oriented closed curve follows and then backwards. For a static magnetic vector potential, the magnetic contribution to the relative wave phase isHere is the oriented magnetic flux through a spanning surface. Equal or calibrated nonmagnetic propagation phases are assumed. For an electron, , where is the elementary charge; reversing reverses the sign. The observable is the gauge-invariant holonomy , rather than a unique local value of the magnetic vector potential.
The accessible region is a multiply connected region: cannot contract to a point without entering the excluded flux region. Stokes theorem does not set the line integral to zero, because a spanning surface must cross that excluded region, where the magnetic field need not vanish. There is real magnetic flux in the apparatus; only the accessible paths are idealized as free of the magnetic field. The exterior of a finite straight solenoid also permits routes around its ends, so its exact topology and leakage differ from those of an infinite solenoid or an excluded solid torus.
An explicit model makes the obstruction visible. Outside an infinite flux tube of radius , choose cylindrical coordinates andIts curl vanishes there, but a loop with winding number has . Locally ; the angular coordinate changes by on a circuit. For generic , that candidate gauge removal changes the wave function's single-valued boundary condition. On a simply connected region, a smooth static magnetic vector potential with zero curl instead has a globally defined scalar primitive and is a pure gauge potential. Thus local zero magnetic field and globally removable magnetic vector potential are different conditions.
Two accessible paths can link inaccessible magnetic flux
. Original functional geometry. Left: a cross-section of an ideal infinite flux tube; traverses the blue route forwards and the orange route backwards. Right: a meridional section of an excluded solid torus; the magnetic field circulates inside its core, with opposite signs through the section. One route passes through the central hole and the other outside the torus. The drawn linking surface intersects one core section. Paths denote coherent alternatives, not measured trajectories; shielding thicknesses and beam optics are schematic. Source. Details.For an original interference example, take mutually coherent scalar amplitudes with constant individual intensities and an imposed carrier phase , as in off-axis holography. ThenThe interference fringe spacing is . An electron enclosing has , shifting maxima by for this orientation. Increasing the magnetic flux by changes by and restores the same pattern: the electron Aharonov-Bohm effect has magnetic flux quantum . This uses , the Planck constant. It does not require the source's magnetic flux to vary continuously during a single exposure.
For , , the extrema are , , and the interferometric visibility is . A fixed Aharonov-Bohm phase translates these fringes without changing their contrast. Averaging unresolved fluctuating phases can reduce the contrast; a darkened pattern alone cannot identify enclosed magnetic flux. These formulas assume coherence, indistinguishable alternatives and stable beam envelopes.
The appeal of the Aharonov-Bohm effect is that a local Lorentz force calculation along either ideal path misses information carried by their global arrangement. It gives a physical example of holonomy and supplies the encircling phase used in Chern--Simons flux attachment. This alone does not establish intrinsic topological order. The static comparison also matters: changing magnetic flux can induce an electric field, so a time-dependent experiment requires the scalar-potential contribution as well as the displayed spatial line integral.
Aleksander Stefanov 2026-11-05
Aleksander Stefanov works across mathematical physics, mechanics and optical measurement. A 2022 Sofia University academic statement identifies his education in theoretical and mathematical physics, doctoral work on nonlinear dynamical systems associated with Lie algebras, and work in the Faculty of Mathematics and Informatics. It describes research on integrable models, walking-robot dynamics and educational physical-constant measurements.[ref]
Statement on Aleksander Stefanov's associate-professor application by Ivan Chavdarov. pp.2–3, candidate information and research contributions
The same document identifies Korteweg-De Vries equation and nonlinear Schrödinger-type models among his theoretical interests. He also coauthored the 2023 theoretical and experimental comparison of Gouy phase for Bessel-Gaussian beams with Lyubomir Stoyanov, Alexander Dreischuh and Gerhard G. Paulus.[ref]
Gouy phase of Bessel-Gaussian beams: theory vs. experiment by Lyubomir Stoyanov and others. Published byline and affiliations
An original example illustrates the quantitative idea behind a noise-based constant measurement. For ideal independent charge-transfer events, the one-sided current shot noise spectral density is . With mean current , elementary charge C and a rectangular effective noise bandwidth kHz, the predicted root-mean-square fluctuation isThese stipulated numbers are not data from Stefanov's apparatus. They explain why estimating charge from noise requires a calibrated gain, known bandwidth and a model for other fluctuations. Thermal noise and detector noise must be distinguished from the charge-transfer contribution; a measured noise amplitude alone is insufficient.
The attraction of this work is the bridge between mathematical models and observable signals. The academic statement describes physical walking-robot tests as well as electronic measurements; those are different ways to test a theoretical prediction. The available sources identify this Sofia researcher, and do not justify merging him with unrelated researchers who share a surname.
Ampere 2026-10-14
The ampere is the SI unit of electric current. Since 20 May 2019 its definition fixes the elementary charge exactly at , with . This gives electrical measurements a reference based on a fixed elementary charge. [ref]
https://www.nist.gov/si-redefinition/ampere-introduction. NIST, Ampere: introduction to the 2019 definition
; [ref]. Antiporter 2026-11-05
An antiporter is a membrane protein that couples movement of different substances in opposite directions across a cell membrane. In an idealized exchange cycle, one substrate moves inward while another moves outward. The ratio transported, or stoichiometry, depends on the transporter; opposite directions do not imply equal numbers or zero net electric charge.
NhaA provides a measured example. In a 1993 study, purified Escherichia coli NhaA was reconstituted in sodium-loaded membrane vesicles. Parallel measurements of sodium efflux and proton influx supported exchange of two protons for each sodium ion. An independent method based on the generated membrane electric potential difference and ion gradients agreed under the stated coupling assumptions.[ref]
The charge accounting is revealing. In the tested direction, two inward singly positive ions and one outward singly positive ion produce one net positive charge moving inward per exchange cycle. Thuswhere is the magnitude of the elementary charge. An antiporter can therefore be electrogenic. Directional exchange, charge balance and the energy available from an electrochemical gradient must be assessed separately.
Atomic nucleus Created 2026-10-06 Updated 2026-10-18
The central system of protons and neutrons in an atom. Its mass number is its baryon number in ordinary nuclear states; is the proton number and the neutron number.
The nucleus contains almost all of an atom's mass and carries positive electric charge , where is the elementary charge. The atomic number identifies the chemical element; changing at fixed gives another isotope. The mass number counts nucleons, rather than specifying the exact nuclear mass: nuclear binding energy lowers the mass of a bound system relative to its separated constituents. The simplest nucleus is a single proton; other atomic nuclei can contain many protons and neutrons bound by the nuclear force.
A nuclear quantum state has properties such as spin and a spatial nuclear charge distribution. These are different questions from merely counting nucleons. A small-angle elastic scattering measurement can reveal a nuclear charge radius, while a wider range of momentum transfer tests the distribution's shape. The Hofstadter nuclear electron scattering experiment made this connection between scattering patterns and nuclear structure experimentally concrete.
Atomic number Created 2026-10-13 Updated 2026-10-20
The atomic number is the number of protons in an atomic nucleus, and fixes the chemical element. It is a count, with no units. An atomic nucleus with six protons is always carbon, regardless of how many neutrons accompany them or how many electrons surround it. See the IUPAC Gold Book, atomic number.
Three independent bookkeeping questions become easy once their symbols are kept separate. Let count neutrons, count electrons, be the mass number, and be the net electric charge. A proton carries electric charge and an electron carries , where is the positive elementary charge; a neutron carries zero net electric charge. HenceThe reasoning is just counting: add protons and neutrons for , and subtract negative electron contributions from positive proton contributions for . A neutral chemical atom has , so . For a positively charged ion, fewer electrons remain. Notation gives the mass number at upper left and atomic number at lower left, with standing for the chemical element; a right superscript such as specifies the electric charge in units of . See Flowers et al., Chemistry 2e, atomic structure and symbolism.
For neutral carbon-12, , the atomic number gives six protons, the subtraction gives six neutrons, and neutrality gives six electrons. Neutral carbon-13, , instead has neutrons, with the same six protons and six electrons. Thus these two isotopes occupy the same carbon box in the periodic table.
For neutral sodium of mass number , , the counts are eleven protons, neutrons, and eleven electrons. Removing one electron gives the ion : , so . Both its atomic number and its twelve neutrons stay unchanged. This is ionization, not conversion into the chemical element neon, even though a neutral neon chemical atom also has ten electrons.
Atomic number fixes chemical element identity: changing isotopes changes neutrons, while forming a sodium ion changes electrons
. The dots are counting tokens, with protons and neutrons in an atomic nucleus inventory and electrons in a separate inventory. Their layout does not depict physical positions, sizes, or orbits. Neutral carbon-12 and carbon-13 differ by one neutron; neutral sodium of mass number 23 and its singly positive ion differ by one electron. Details.This bookkeeping is useful whenever a symbol must be translated into a physical inventory. Mass number answers how many protons plus neutrons there are; electric charge answers the imbalance between protons and electrons; atomic number alone answers which chemical element it is. Keeping those questions distinct prevents an isotope or an ion from being mistaken for a different chemical element.
Atomic units 2026-10-18
The convention used here chooses units in which the numerical values of the reduced Planck constant, electron mass, elementary charge and times the vacuum permittivity are one.
Blue light-emitting diode Created 2026-10-18 Updated 2026-11-05
Blue transitions motivate wide-bandgap semiconductors, but a large band gap alone cannot guarantee efficient emission. Gallium nitride has a direct band gap; indium gallium nitride composition tunes the transition energy.[ref]
https://www.kapitza.ras.ru/~glazkov/students/Nobel-akasaki-lecture.pdf. §2, printed pp. 8–10: direct/indirect gaps and nitride composition range
For an emitted photon, with frequency and vacuum wavelength ,where is the Planck constant and the vacuum speed of light. Multiplying energy by wavelength gives . Thus chosen wavelengths and correspond to and : blue requires more energy per photon than red. A stipulated transition energy instead gives , in the ultraviolet. These are conversions, not measured emission lines.
For near-edge emission, estimates the photon energy from the emitting material's band gap. Quantum well confinement or impurity transitions can change it. The 1994 blue light-emitting diode used zinc-doped indium gallium nitride, emitting below its near-edge transition.[ref]
Candela-class high-brightness InGaN⁄AlGaN double-heterostructure blue-light-emitting diodes by Shuji Nakamura and others. p. 1688, Fig. 2 discussion: Zn-related emission
The measured forward terminal electric potential difference is also not fixed by , where is the elementary charge. It depends on electric current, temperature, contacts and series electrical resistance. Even the simple Shockley diode equation with series electrical resistance has , whereas an optical transition does not acquire an extra energy merely because the contact drop increases. Consequently, extracting a band gap from one terminal-voltage reading is not justified.
Bond polarization Created 2026-10-13 Updated 2026-10-20
Bond polarization is unequal sharing of electron density across a chemical bond. An electronegativity difference is a heuristic for its direction and tendency, not a unique partial atomic charge.
A simple two-site model makes the notation explicit. Represent each site by effective positive electric charge , and allocate expected electron populations to and to , with . Here is the elementary charge; these effective sites omit the internal structure of real chemical atoms. Subtraction givesFor the stipulated illustration , the populations are and , and the effective partial atomic charges are and . Fractional expected populations do not split an individual electron into pieces. The total population remains two, and the pair remains neutral. No formula connecting to has been assumed; many electron density distributions and partitioning conventions can share one qualitative electronegativity ordering.
Stipulated two-site bond polarization: expected electron populations, effective partial atomic charges, and opposite chemical and physical arrow conventions
. Original model with and , effective positive site charges , and two expected electrons in total. The population bars are bookkeeping weights, not a measured electron density map. Arrow lengths illustrate direction only; no empirical electronegativity values or charge calibration are implied. Details. Bubble-chamber stereo reconstruction 2026-10-18
Stereoscopy supplies depth because different cameras see different projections of the same track. A functional reconstruction first matches the same interaction vertex and track segments across views. A calibrated lens and window model maps each measured image coordinate back to a ray inside the liquid. Refraction at the windows must be included. Intersecting the rays, or finding their closest agreement when measurements have errors, estimates three-dimensional coordinates. Several points then determine a trajectory, rather than only a projected arc.
An original ideal-camera model makes the geometry explicit. Take two parallel pinhole cameras with centers and , focal length , and optical axes along . Use virtual image planes in front of the pinholes so that image coordinates have the same orientation as the scene. A point then givesSubtracting the horizontal image coordinates gives disparity , henceFor stipulated , , , and , the reconstructed point is . These are ideal optical inputs, not dimensions of Alvarez's apparatus. This model omits refraction and lens distortion; actual calibration replaces its simple ray geometry. Since , the same disparity error gives worse depth precision for distant points.
From stereo bubble photographs to coordinates, momenta and an event ensemble
. Original functional diagram. The chamber, camera positions and tracks are schematic, not a historical mechanical drawing. The parallel-camera ray construction illustrates an idealized model without refraction. Details.The Lorentz force then supplies a momentum scale. With magnetic field uniform and negligible stopping power over a fitted segment, bubble-chamber track readout gives . The local three-dimensional helix tangent supplies the missing direction: if is its angle to the field, . In practical units,Here is the elementary charge and the speed of light. A short, almost straight arc poorly constrains its radius of curvature; a visually sharp track can therefore have poor momentum precision.
Cathode-ray attenuation with finite detector acceptance Created 2026-10-18 Updated 2026-10-20
An original toy model separates two ways to lose a central cathode ray signal. Let be forward depth into a uniform gas. Normalize the entering electron population to one. Write for the fraction still in a narrow forward channel, and for the fraction diverted into a wider collection channel. Assume constant removal rate per unit depth in both channels, and constant transfer rate from to , with no return. Removal means that an electron stops or is trapped before reaching the collecting plane; it does not mean that its electric charge disappears. The wide ideal collector accepts all surviving members of both channels. This is a stipulated two-population differential equation model, not a general law of electron transport:The first equation gives exponential decay. Adding the equations gives for , henceThese formulas also give a conservation check: . The fraction has been removed before the plane, while remains present but misses the narrow collector. An exponential fit to the narrow signal therefore measures , not the removal rate by itself. This is an identifiability issue: one declining signal cannot distinguish the two unknown rates.
For a worked example, choose and . These are invented teaching inputs, not measured coefficients for air or Lenard's apparatus. At ,Thus about misses the narrow collector, although only about has been removed in this model. Treating the whole narrow-signal deficit as stopping would confuse redistribution with removal.
Suppose a calibrated readout is proportional to arriving electron number with the same response for either channel. Choose an empty-path signal arbitrary units, of which is background; the two collection geometries have the same calibrated reference. The calculated readings at are and . After background subtraction, define for each geometry. Then the original inverse problem has the solutionA single narrow reading would instead allow every nonnegative pair with . Using the raw ratios without subtracting gives an erroneous narrow rate of about . In a real fluorescent screen, the assumed response must be tested: deposited energy and conversion to light need not remain constant as electrons slow. Repeating the comparison at several depths tests the constant slopes, although straight slopes alone do not establish the microscopic mechanism.
Actual electrons change kinetic energy and direction. Electron stopping power describes mean kinetic energy loss per travelled path length ; collisional losses include ionization, while radiative losses include bremsstrahlung. The continuous slowing-down approximation range integrates reciprocal total electron stopping power, neglecting fluctuations. It approximates travelled path length, not forward penetration depth.[ref]
Appendix: Significance of Calculated Quantities. Stopping-Power and Range Tables for Electrons, Protons, and Helium Ions by M. J. Berger and others; Appendix: Significance of Calculated Quantities, collision/radiative/total stopping power, CSDA range, projected range and detour factor
As a separate original limiting example, stipulate a straight path, constant , and entering kinetic energy . Then until stopping, and . In that deterministic model every entering electron reaches each depth below and none crosses a plane beyond it. There is no exponential population tail. Real fluctuations and electron scattering make the situation more complicated, but the example already proves that continuous energy loss does not imply constant-rate removal.The window also changes the entering population: source kinetic energy before the foil need not equal just outside it. For an electron initially at rest, an ideal static accelerating electric potential difference supplies electrical work , where is the elementary charge. If losses before and within the foil total , a transmitted electron enters the observation chamber with . A screen's brightness determines neither nor . These formulas specify a modern ideal work-energy theorem argument; no numerical historical voltage or foil thickness is inferred from the diagram.
CCD clocked charge transfer Created 2026-10-18 Updated 2026-10-20
For an electron packet, a sufficiently positive gate electric potential attracts electrons beneath the insulating layer of a MOS capacitor. The corresponding potential energy is , where is the magnitude of elementary charge: a larger electric potential gives a deeper potential well for electrons. A drawing of potential energy must therefore reverse the vertical sense of a drawing of electric potential.
A simplified three-phase transfer raises the adjacent gate's electric potential before lowering the old holding gate. This overlaps the accessible regions, then leaves the packet under the new gate. Repeat with the next gate to move it forward. Isolated wells with an intervening barrier would store the packet without transferring it.[ref]
Charge Coupled Semiconductor Devices by Willard Sterling Boyle and George Elwood Smith. Boyle and Smith, 1970, p. 587, neighboring capacitors and manipulated electrode potentials
CCD clocked charge transfer and cumulative charge-transfer efficiency
. Original explanatory potential energy profiles show storage, overlap and arrival, with lower curves meaning more attractive regions for electrons. These are qualitative effective profiles, not measured voltages or prototype wiring. The right panel calculates the main-packet fraction for the stipulated constant-efficiency model; charge absent from that packet may be deferred or truly lost. Details. Charge lattice inference from oil drops 2026-10-18
An integer pattern must survive the stated measurement uncertainty. For an original simulated example, choose a reference electric charge , define , and stipulate state meansHere each is an independent standard uncertainty of a state mean, before shared calibration effects. The generator constructs repeated noisy observations with these means; the numbers are deliberately chosen, not historical data. There is no conversion of to coulombs and no measured value of the elementary charge in this example.
For a candidate spacing in units of and proposed integers , use weighted least squares:The last two expressions follow by differentiating the quadratic in and propagating the independent errors. They are conditional on fixed, correct integer assignments and the stated error model. They do not include uncertainty from choosing those assignments. For , they give , , and . Such a small residual is compatible with this chosen error scale; it is not evidence that the errors vanish. A chi-squared distribution interpretation additionally needs the appropriate normal distribution error model and allowance for the fitted parameter; searching many assignments changes that interpretation.
Finite noisy electric charges fit a candidate unit and its subdivisions
. Original calculation for the simulated state means above. Horizontal bars show one standard uncertainty. Both spacings and have exactly the same fitted locations and residuals when the integer labels double. The lower curve minimizes over integers separately at every candidate spacing; a low residual alone cannot identify the elementary charge. Details.The obstruction is identifiability: replacing by for any positive integer leaves every predicted reading unchanged. In particular, an -spaced pattern also fits an lattice using even indices. Even the coarsest well-fitting spacing need not be the physical unit: a dataset containing only even charge states can have twice that unit. Worse, if arbitrarily fine spacings and unrestricted integers are allowed, rounding each givesConsequently a finite fit cannot prove a minimal transferable electric charge. Reproducible smallest observed jumps supply additional evidence; interpreting them as single-carrier transfers requires independent physical support. One visibly abrupt transition could contain several unresolved transfers. In the simulation the successive differences are , , and , each with standard uncertainty . These support changes near conditional on that unit; they equally support units of . Neighboring differences share a state reading and are therefore correlated, even though the state means were stipulated independent.
A shared scale error can preserve every apparent integer relation. To first order, an independent fractional scale standard uncertainty adds to the covariance matrix of the . For the simulation, stipulating changes the conditional uncertainty of to approximately , despite the same residual pattern. Repeating timings cannot average away this common scale contribution. In the uncorrected continuum model in elementary charge, holding the other measured inputs fixed gives , so a small fractional error in air dynamic viscosity causes times that fractional error in inferred electric charge. The gas slip correction to Stokes drag requires its own propagation. Pattern agreement, drop-stability controls and absolute measurement calibration together make the inference persuasive within resolution.
Charge-to-mass ratio Created 2026-10-18 Updated 2026-10-20
The charge-to-mass ratio is a body's electric charge divided by its mass . Its SI unit is the coulomb per kilogram, . In a prescribed electric field and magnetic field, nonrelativistic acceleration depends on through the Lorentz force. Two bodies with the same initial position, velocity, and charge-to-mass ratio therefore have the same trajectory in this ideal model. For an electron, write with the elementary charge: , whereas the positive number is the magnitude of the charge-to-mass ratio.
Circular-orbit derivation of the Bohr model Created 2026-10-18 Updated 2026-10-20
Consider a single electron of mass and a point atomic nucleus of mass and positive electric charge , with the elementary charge. Use nonrelativistic classical mechanics, omit external fields and interactions with other electrons, and writeHere is the Coulomb two-body reduced mass, the vacuum permittivity, and the Planck constant. The separation and relative speed describe the two-particle relative coordinate; neither body is silently pinned in place. The electron's own radius about the centre of mass is .
For the assumed circular orbit, Coulomb's law provides the required centripetal acceleration, and the imposed orbital angular momentum condition isSubstitute into the first equation and cancel to obtainThe kinetic energy is and the Coulomb potential energy is , with zero energy at infinite separation. HenceThis derives the energy sequence from the stated circular model; the modern Schrödinger equation derivation is the distinct series-termination quantization of the Coulomb radial equation. The radius above scales as , whereas the binding energy scales as . The Bohr radius article supplies the corresponding Coulomb potential length scale. The nonrelativistic assumption requires , with the speed of light.
For an original numerical example choose , , , , , , and . Treat these as stipulated constants for the calculation. They give , , and , where denotes an electronvolt. At , and ; the ground-state ionization energy is .
Taking gives . A finite nuclear mass reduces every binding energy by and increases each separation by . This follows from relative motion, not a fitted correction to individual spectral lines. Replacing the atomic nucleus by a heavier isotope changes the same factor, providing another check of the model.
Classical electron radius Created 2026-10-18 Updated 2026-10-20
The classical electron radius is the length scale formed from the elementary charge, vacuum permittivity, electron mass and speed of light. It is not a measured material radius of an electron. In the classical low-energy scattering model it sets the Thomson cross-section, .
CODATA recommended values of the fundamental physical constants 2014 by National Institute of Standards and Technology Created 2026-10-20 Updated 2026-11-05
The 2014 adjustment gives the historical Planck constant, elementary charge and electron mass used for numerical evaluation. These are external reference values, without a claim about the exam handbook's rounding.
Cold-plasma radio dispersion 2026-10-18
Take a cold, unmagnetized, collisionless plasma with uniform equilibrium electron density , fixed neutralizing ions, and a small electromagnetic wave that is a transverse wave. Cold means that thermal-motion corrections are neglected. For electron mass , elementary charge magnitude and electric field , the linear Newton's second law equation is . Thus and the current density is . Writing the induced electric polarization as gives a negative electric susceptibility. With vacuum permittivity ,The plasma frequency controls the response. For , the propagating branch has real refractive index . For , this homogeneous model has an evanescent wave, not an ordinary propagating wave with a negative real refractive index. In a slowly varying vertical profile, a normally incident ray approaches a turning region where ; the geometrical-ray approximation fails right at that region. At oblique incidence the conserved horizontal wave vector changes the turning condition. A smooth density gradient can therefore return a skywave without a mirror or a layer of metal.
For a homogeneous propagating section, direct differentiation of the dispersion relation givesA phase velocity greater than does not send information faster than . Here a narrow wave packet has group velocity , while the full causal response must still respect special relativity. Even this stripped-down plasma is strongly dispersive near its plasma frequency. In the actual ionosphere, collisions produce absorption, and the magnetic field of Earth changes the response with direction and wave polarization; a single real scalar cannot capture all of that behavior.
Current density Created 2026-09-24 Updated 2026-10-20
The current density describes the amount and direction of local electric charge transport per area per time. Its SI unit is . Through a small area element with unit normal , the contribution to electric current is : the dot product selects transport through the surface. A current density tangent to the surface contributes zero. If current density is uniform and perpendicular to a wire's transverse slice, its magnitude satisfiesHere is the wire cross-sectional area. For nonuniform current density, is only the average normal component, and the surface integral is needed. [ref]
https://openstax.org/books/university-physics-volume-2/pages/9-2-model-of-conduction-in-metals. Ling, Sanny and Moebs, §9.2: local current density
.Consider two separate uniform-flow cases, each carrying electric current . A wire cross-sectional area of gives ; doubling the wire cross-sectional area to gives . Equal electric current can therefore mean different local transport intensity. This distinction matters for Joule heating, whose local power per volume depends on current density and electric field.
Equal electric current through different wire cross-sectional areas gives different current densities
. Both cases carry with uniform normal current density. The transverse slices use the same spatial scale; the bars compare . Source. Details.For a toy electron transport model, stipulate mobile electron number density and drift velocity , with the positive unit normal . Each electron has electric charge , where the elementary charge is exact in SI. These are defined model inputs, rather than measured parameters of a particular material. [ref] The current density and its magnitude areFor wire cross-sectional area and constant transport over time , this givesThe two minus signs make conventional current point opposite to the electron drift velocity. A small drift velocity can carry an appreciable electric current because many charge carriers contribute; it does not specify the propagation speed of an electrical disturbance.
Depletion region 2026-10-18
An illustrative abrupt-junction depletion approximation assumes uniform, fully ionized donor impurities and acceptor impurities, negligible mobile space charge in the depleted layer, and permittivity . For area , doping number densities and built-in electric potential difference , it givesHere is the elementary charge and is positive for forward bias. Increasing both doping densities reduces in this estimate. That explains the preparation strategy for a tunnel diode; it does not make this sharp-depletion approximation a precise microscopic model of a degenerate semiconductor.







