For two ideal strings under a common tension, the positive mechanical impedances satisfy , where are their linear mass densities. The reflected fraction of incident power is . Solving for the positive ratio gives or its reciprocal. Squaring yields the displayed linear mass density ratios. For , the heavier string has times the lighter string's linear mass density; the impedance ratio is only .
Supercritical airfoil 2026-11-05
A supercritical airfoil is shaped to control transonic flow so that shock-related drag rises less severely over its intended operating range. Here supercritical refers to operation beyond the onset of locally sonic flow around the section; the freestream need not be supersonic. Characteristic shaping includes reduced upper-surface curvature over much of the chord and substantial aft camber, rather than a requirement that no shock ever appear.
A primary NASA experiment describes the design objective as reducing losses from shock waves and flow separation, using a large leading-edge radius, a flattened upper surface and a strongly cambered trailing region. It investigated changing the rear contour to suppress an off-design second velocity peak.[ref]
Wind-tunnel Investigation of Effects of Rear Upper Surface Modification on an NASA Supercritical Airfoil by Charles D. Harris and James A. Blackwell, Jr.. Introduction, printed pp. 1–2
The pressure recovery must work with the viscous boundary layer; a favorable change at one condition can worsen another.The apparatus makes that tradeoff observable. Tests in the Langley 8-foot transonic pressure tunnel covered freestream Mach numbers –. Flush surface orifices supplied pressure distributions, while a rake about one chord downstream sampled wake pressures for drag inference. Controlled transition strips helped specify the boundary-layer state. The tested attempt to reduce the second peak adversely affected drag at design conditions.[ref]
Wind-tunnel Investigation of Effects of Rear Upper Surface Modification on an NASA Supercritical Airfoil by Charles D. Harris and James A. Blackwell, Jr.. Summary; Apparatus and Techniques, printed pp. 4–6
These observations motivate off-design pressure recovery of a supercritical airfoil; optimizing a single contour feature is not enough.For an illuminating coefficient calculation, define . A measured pressure recovery from to over a short distance has . At stipulated this is . The abrupt recovery identifies a region to investigate with higher spatial resolution and a compressible-flow model; those two numbers alone do not establish the full shock strength or separated-flow extent.
A separate original performance comparison fixes reference area, dynamic pressure and lift coefficient. Reducing measured drag coefficient from to at and reduces drag by . At , the associated drag-power difference is . These are stipulated values illustrating how a coefficient improvement translates into force and power; they are not a promised improvement for every supercritical section.
A useful comparison therefore matches Mach number, Reynolds number, lift, surface condition and transition treatment, and measures both surface pressure and wake or balance drag. Compare the full intended operating range, including lower-speed lift and off-design conditions. Thin-airfoil incompressible calculations cannot by themselves establish transonic drag performance.
Supply rate 2026-11-05
A supply rate specifies the instantaneous quantity whose time integral is compared with a change of storage function in dissipativity. With control input , plant output and state , a chosen function enters the balanceThe supply rate can be negative: it then represents net withdrawal in the chosen accounting. Its physical interpretation depends on the variables and sign convention, rather than on the word supply alone.[ref]
Dissipative Dynamical Systems, Part I: General Theory by Jan C. Willems. General Theory, definition of supply and storage inequality
For a mechanical terminal with applied force and inward-convention velocity , choose , the entering power. For an electrical terminal with electric current entering its positive-potential terminal, the corresponding choice is , with an electric potential difference. Both have units of watts when is energy. Reversing one terminal sign without changing the other reverses the apparent power flow.
An original capacitor example illustrates the sign. Let , terminal electric potential difference , and charging electric current . Its stored electrostatic energy is , and at that instant . With the same potential and , the supply rate is and storage decreases. This is consistent with nonnegative stored energy; negative supply does not mean negative storage.
A different supply rate can express a signal-performance requirement:Nonnegative final storage and zero initial storage then bound accumulated output-square by times accumulated input-square. These squares need not be physical power. Scaling or changing the units of the signals requires corresponding changes in the coefficients. A general real quadratic choice can be written as , with symmetric ; the selected quadratic form states which input–output relation is being tested.
System temperature 2026-10-20
The equivalent input noise temperature of the antenna-plus-receiver system is defined by available noise power in one matched polarization of waves mode. It includes receiver noise and the appropriate sky and instrumental contributions. It is not generally the physical temperature of a single component.
A tangential force integral around an instantaneous moving loop is not generally the force work along the actual particle trajectory. For an expanding circular guide, the particle has both radial and tangential velocity; the magnetic radial and tangential powers cancel exactly even when the tangential circulation is nonzero.
Testing a differential thermal actuator 2026-10-18
A proposed bench test can isolate the mechanism without a gas burner. Illuminate a blackened and a polished sample of matched material and geometry, record both temperatures and their relative displacement, then block the beam. Measure incident irradiance separately. Swap the surface treatments, hold the ambient temperature fixed for the illumination test, and change it with the beam blocked for a common-heating control. This is a model-based experiment proposal, not a report of measurements.
A larger response of the dark sample would support a difference in absorbed power; the displacement and cooling curves test the assumed linear thermal expansion coefficient and time constant. A stable illumination step that never reaches the switching gap challenges the chosen parameter model rather than the existence of thermal expansion. Nonuniform sample temperature, unequal losses and mechanical friction can separate the physical device from the ideal equations.
Thermal boundary resistance 2026-10-18
Thermal boundary resistance describes a temperature drop between the two sides of a material interface carrying heat flux. Efficient thermal conduction within each material does not guarantee efficient heat transfer between them. The solid–helium case is Kapitza resistance; the broader concept also includes solid–solid interfaces. [ref]
Let and be the temperatures extrapolated to the interface from its solid and liquid sides, each treated as internally in thermal equilibrium. For uniform normal heat flux through area , define the finite-drop, area-specific thermal resistance and the resistance of the whole interface byThe macroscopic jump represents an unresolved interfacial region; it is not a claim that one point has two equilibrium temperatures. At nonzero heat flux, the two sides are outside mutual thermal equilibrium. A measured difference between distant thermometers also contains bulk temperature gradients, which must be measured or bounded before assigning all of it to the interface.
An energy balance explains why a temperature jump can coexist with continuous heat flux. For a stationary interfacial region with no local work or heat source,The first law of thermodynamics therefore requires in a steady state. It does not require . For a heated sample with electrical power , an independently determined outward parasitic loss and no other inputs,Here is the heater's electric potential difference and its electric current. Subtracting a lead loss means subtracting power before dividing by area; is not the total heating power. Unknown losses and stored internal energy prevent that simple steady inference.
For a one-dimensional comparison, put an interface between two slabs with the same area , positive constant thermal conductivities and lengths . Neglect side losses. Integrating Fourier's law across each slab givesThus, for a linear interface with constant , the series result isThese slab formulas are a chosen thermal conduction model, not a bulk transport law for moving liquid helium. If the interface law is nonlinear, substitute its own relation between and into the preceding balance; a single constant resistance cannot describe every load. Increasing bulk thermal conductivity has diminishing benefit when the interfacial drop dominates. Increasing usable contact area reduces the whole-interface thermal resistance if the local interface law and the other conditions remain fixed.
Thermal noise loading 2026-10-18
An external electrical load changes the terminal noise. Connecting a purely resistive load to the noisy resistor gives the voltage divider ratio . The source resistor's contribution at the load isIn a rectangular signal bandwidth , the power delivered by that source contribution to the load isbecause . Equality occurs at : this is matched available noise power. Matching halves the voltage, quarters its power spectral density, and gives . Dividing the squared open-circuit voltage by would instead give four times this available power.
These expressions isolate the source resistor's contribution. A real load resistor also generates thermal electrical noise. At the same temperature its independent contribution produces the equal reverse power flow, so the net thermal power transfer is zero at thermal equilibrium. For example, two equal resistors at the same temperature have total terminal power spectral density , equivalent to . One contribution alone is . The fictitious noiseless series in the Thévenin equivalent is not an additional physical source: adding its noise again would double count the original resistor.
Thermal noise worked example 2026-10-18
For an original hypothetical calculation, stipulate , , and an ideal rectangular measurement signal bandwidth . Using givesA matched electrical load receives root mean square from the source resistor, giving . These are stipulated model predictions, not laboratory measurements. Increasing raises the open-circuit voltage noise but does not increase the matched available power. Restricting the measurement signal bandwidth reduces root mean square noise as its square root; it improves signal-to-noise ratio only if the desired signal is preserved.
Thermal Raman line ratio 2026-10-18
Assume one harmonic normal mode at thermal equilibrium, weak spontaneous excitation far from electronic resonances, the same collection solid angle and wave polarization, and matched response after instrumental correction. The Boltzmann distribution givesHere is the Boltzmann constant, is temperature, and is the probability of vibrational quantum number . Thus . Linear coupling to has squared oscillator matrix elements proportional to for Stokes Raman scattering and for Anti-Stokes Raman scattering. Summing over initial levels gives strengths proportional to and respectively; their ratio is , even when levels above are occupied.
Let and denote line-integrated radiant intensities, meaning power per collection solid angle. The off-resonant electric dipole radiation law adds the fourth power of emitted frequency:The photon rate divides each line's power by its own . Consequently, the ideal response-corrected anti-Stokes/Stokes count-rate ratio has the third power of the same frequency ratio. Peak heights alone do not give line-integrated radiant intensities if linewidths differ. Uncorrected detector counts can also include unequal detector response and unequal optical filter transmission. Resonant enhancement, overlapping spectral lines, nonthermal populations and local optical heating can invalidate a temperature inferred from this simple formula.
For a matched receiver accepting one spatial mode and one polarization of waves, the thermal contribution to the available spectral power of a blackbody isThis expression excludes a zero-point term; it is the thermally emitted contribution. Defining the Rayleigh-Jeans law equivalent antenna temperature by gives the displayed relation. With ,Thus requires . It is an approximation with a frequency-dependent error, rather than a redefinition of thermodynamic temperature.
For the stipulated and , and . Replacing by here would differ by about . At much higher frequencies, the approximation fails more strongly. A real instrument averages over its measured frequency response and antenna beam pattern, so using a single central frequency adds a narrow-band approximation.
Thermoelectric cooler energy balance 2026-10-18
The chosen steady-state model isHere is the terminal voltage drop along positive electric current through the module. Its Seebeck effect term opposes the cooling supply. The cold Peltier effect term removes heat; Joule heating and returning heat conduction reduce the available cooling. At zero electric current, : the passive leak warms c and removes heat from h, consistent with the stated signs. Subtracting the two face equations cancels heat conduction and gives the electrical power, an independent conservation of energy check.
The factor one half is an ideal-model result, not a universal rule for every contact. To see its origin, let run from cold to hot along a uniform equivalent leg of length , cross-sectional area , electrical resistivity and thermal conductivity . With constant coefficients, insulated sides and no Thomson effect, steady conservation of energy givesThe Fourier's law heat current in the positive direction is . At it equals , and at it equals , using and . Adding the local transported heat current gives the two face equations. Summing equivalent legs preserves this accounting. Nonuniform material properties, side losses or asymmetric contact dissipation require a revised model.
For an original toy module, stipulate , , , and . At ,The coefficient of performance is defined here only for refrigeration with and . The hot-side assembly must remove , not just the extracted . These are stipulated calculations, not measurements or a commercial module specification.
At the same fixed face temperatures but , the same boundary definitions give , , and . The formerly cold face is now heated; the formerly hot reservoir supplies . Still . Reversal changes the linear terms, while and the leak at fixed temperatures remain unchanged. Holding the old labels fixed makes this check meaningful.
The corresponding steady entropy production of the module is the outgoing reservoir entropy minus the incoming reservoir entropy:The Peltier effect terms cancel because they carry the same entropy at each end. This cancellation explains the reversible coupling; it does not make finite-resistance operation reversible. In the toy example the two positive contributions are approximately and , giving for either current direction. In cooling operation, combining this inequality with the energy balance gives the Carnot refrigerator limit , equal to for these reservoir temperatures. A coefficient of performance above one would describe transported heat per electrical work, not the creation of energy.
Thermoelectric cooling 2026-10-18
Thermoelectric cooling uses the Peltier effect to remove heat from a load using electrical work. A typical thermoelectric module connects many pairs of different semiconductors electrically in a series circuit and thermally in parallel between two faces. For an idealized pair with , positive conventional current crosses n to p at the cold bridge and p to n at the hot return. With common bridge material and isothermal contacts, the intervening metal contributions telescope: the net pair coefficient is . For identical pairs define the module Seebeck coefficient .
Choose fixed face temperatures , , module electrical resistance and open-circuit thermal conductance . All three module parameters are constants over the chosen operating range. Positive is the orientation absorbing Peltier effect heat at c. Define as net heat extracted from the cold reservoir per unit time, as net heat delivered to the hot reservoir per unit time, and as electrical power entering the module. Despite the conventional letters , both denote power in watts, not accumulated energy. Ferrotec gives the corresponding single-stage equations and distinguishes module performance from bypass leaks.[ref]
Thermoelectric cooling current limit 2026-10-18
At fixed face temperatures, differentiation of the thermoelectric cooler energy balance givesThus current chosen for maximum cooling power is not automatically current for maximum coefficient of performance. Cooling exists only when , and then only between the two positive rootsAt equality the parabola merely touches . For the toy module the interval is approximately , with and . At , the object is heated even in the nominal cooling polarity: . This mathematical interval supplies no permission to exceed an actual device's current or temperature ratings.
The fixed-face constraint matters. With fixed but a freely cooling object, must be solved from its heat load and leaks rather than held at while claiming an arbitrary temperature drop. For zero load and optimal current, the same model givesHere has units and is a module parameter. The toy model gives and when . This is an ideal zero-load limit with stipulated constant properties; cooling a real load requires above zero and reduces the attainable drop. Contact thermal resistance, a warming heat sink, external leaks and temperature-dependent coefficients further change the result. Electrical control is convenient, but conservation of energy still requires a thermal path that removes the extracted heat plus the electrical input.
Thermoelectric effect Created 2026-10-13 Updated 2026-10-18
A thermoelectric effect couples heat transfer and the transport of electric charge: a temperature gradient can generate an electromotive force, while an electric current can carry heat and cause heating or cooling at a junction of different materials. This coupling makes electrical measurement of temperature possible through a thermocouple, and permits conversion of a sustained flow of heat into electrical work. A finite open-circuit voltage does not itself deliver power: electrical power requires an electric current through a load. Thermoelectric conversion therefore involves both electromagnetism and thermodynamics. [ref]
https://thermoelectrics.matsci.northwestern.edu/thermoelectrics/history.html. Northwestern thermoelectrics research group: thermoelectric effects and applications
. Thermoelectric generator Created 2026-10-20 Updated 2026-11-05
A thermoelectric generator converts part of a heat flow driven by a temperature difference into electrical output through the Seebeck effect. Thermoelectric legs connect hot and cold sides; their electrical arrangement combines the generated voltages while their thermal paths carry heat between the sides.
A load draws electric current, so delivered power depends on both open-circuit voltage and internal resistance. Shorting the output gives current but zero terminal voltage, while an open circuit gives voltage but no useful delivered power. Thermal contacts and heat leakage alter the actual leg temperatures, so a material's thermoelectric figure of merit alone does not specify the complete generator's efficiency.
Thermoelectric power factor Created 2026-10-20 Updated 2026-11-05
The thermoelectric power factor is the product of the squared Seebeck coefficient and electrical conductivity, with units . It combines a material's voltage response to a temperature gradient with its ability to carry electric current. For example, and give .
At fixed geometry and imposed temperature difference, a constant-property thermoelectric generator behaves as a voltage source with internal electrical resistance. Matching the external electrical resistance to it maximizes output power; the material dependence of that maximum is proportional to the thermoelectric power factor. Maximizing thermal efficiency also requires controlling thermal conductivity, which is why the thermoelectric figure of merit includes the thermal denominator.[ref]
Complex thermoelectric materials by G. Jeffrey Snyder and Eric S. Toberer. pp. 105–107, power factor and zT trade-offs
Thermomechanical effect 2026-10-18
The thermomechanical effect couples a temperature difference to a pressure difference across a superleak. For the closed-chamber model in the apparatus figure, consider neighboring equilibrium states with small velocities, negligible height difference and pure helium-4. Let be chemical potential per unit mass, in . The Gibbs free energy differential per unit mass givesThe superleak allows the superfluid to redistribute until the two sides have equal . Setting therefore givesThe sign matters: heating one side at initially equal pressure lowers its ; inflow raises its pressure until chemical balance is restored. The hotter side has the higher pressure. The integral follows the constant- path; it need not be evaluated at fixed pressure when material properties vary appreciably.
For an original local example, stipulate constant , and . The predicted pressure difference is . These are teaching assumptions, not helium measurements. This static thermodynamics relation predicts neither the required heater power nor the filling time: those require heat leakage, channel conductance and chamber heat capacity. An outlet would introduce kinetic energy and a flowing balance, so the static is not a predicted fountain height.
Thermopile absorber 2026-10-18
A thermopile absorber converts incident electromagnetic radiation into heat near the thermocouple measuring junctions. Electrically separate junctions can share its temperature through thermal contact. The reference support provides a path for heat transfer and a comparison temperature; “cold” denotes this reference role, even if it is warmer than the absorber.
Distinguish incident power from absorbed power. A window, the illuminated area, and the absorption of the coating determine their relation. A detector's measured voltage sensitivity can depend on where a small illuminated spot lies.[ref]
Thermopile detectors by Hamamatsu Photonics K.K.. p. 3, §3-1 Sensitivity, Eq. (3-1) and following paragraph: uniform illumination versus a localized spot
The model in thermopile thermal response takes absorbed power as its input, so an optical calibration is a separate step. Thermopile radiative measurement 2026-10-18
PASCO's documented lamp experiment connects a TD-8553 thermopile sensor to a millivoltmeter and places it level with a lamp filament along a meter stick. Lamp and detector axes are aligned. With the lamp off, readings at several positions establish an average ambient thermal radiation background. With the lamp on at a fixed supply setting, detector readings at different distances are compared after background subtraction. Between readings, a reflective shield prevents the detector warming; its shutter also protects the reference junction when idle. Moving the shutter can move the sensor, so fixed geometry matters. The manual's lamp limits must be followed.[ref]
Thermal Radiation System: Instruction Manual and Experiment Guide, TD-8553, TD-8554A and TD-8555 by PASCO scientific. p. 1, Radiation Sensor; pp. 9–11, Experiment 2, Fig. 2.1, procedure and calculations: alignment, lamp-off ambient readings, heat shield and distance comparison
This protocol tests whether the background-corrected electric potential difference approximately follows the inverse-square law over a suitable distance range. It is a relative electromagnetic radiation measurement; those readings alone do not calibrate absorbed power in watts. The manual treats the filament as an approximate point source.[ref]
Thermal Radiation System: Instruction Manual and Experiment Guide, TD-8553, TD-8554A and TD-8555 by PASCO scientific. p. 3, Stefan-Boltzmann Lamp; p. 11, Experiment 2 calculations: point-source approximation and comparison against inverse squared distance
For an absolute calibration, independently known absorbed power and a monitored reference temperature would be needed. A useful additional control is to repeat a fixed detector position before and after a distance sweep: disagreement reveals possible drift. These additions test the measurement chain rather than assuming that background subtraction fixes every error. A finite source, changing illuminated area, reflections, changing reference temperature, and insufficient settling can alter the measured dependence. In particular, the time constant in thermopile thermal response explains why a quick reading and a settled reading may differ. The detector infers its own absorber temperature difference; inferring the source's temperature additionally requires its emissivity, optical geometry and an appropriate thermal radiation model.