Group delay versus pulse-front arrival for an RC load distinguishes a narrow-band modulation displacement from the earliest response to a newly applied input. For the relative amplifier-load model in group delay introduced by a capacitive amplifier load, the causal impulse response is for and zero for . Its convolution with an input that vanishes before zero also vanishes before zero. Nevertheless its group delay is , which is positive and frequency dependent. The phase-derivative definition concerns spectral components and their envelopes.[ref]
An original finite-pulse calculation shows why a threshold measurement gives another time. For an initially relaxed load, apply a rectangular pulse of height and duration . Convolution givesThe first mathematical response occurs immediately after zero. A rising threshold equal to fraction of the input pulse height is reached at only if the pulse lasts at least that long. This is the threshold-crossing time of a finite rectangular pulse through an RC load.
With and , the largest output is only : a threshold is never reached. If instead, that threshold is crossed at . Neither value is the group delay evaluated at .
A pulse generator and oscilloscope can compare the threshold observation with a slow modulation on a carrier; the chosen threshold and modulation bandwidth must be recorded. MIT's laboratory likewise separates square-wave decay measurements from sinusoidal amplitude/phase measurements.[ref]
Laboratory 11: Sinusoidal Steady State Response of RC and RL Circuits by MIT OpenCourseWare. Printed pp. 1–2
If wiring adds a transport delay , shift the impulse response to : the front moves to , while the modulation delay becomes . The immediate onset of the unshifted lumped model is not a model of propagation along a finite-length cable. Known-input calibration of a pulse detector 2026-11-05
Known-input calibration of a pulse detector uses a characterized optical waveform to separate the incident signal from the receiver response. In a linear, baseline-corrected model,where is known input power, a normalized impulse response and the overall responsivity. Recording the complete response givesThus a known reference energy calibrates the area gain without requiring the input to be an ideal impulse. Shape calibration additionally uses the reference waveform.
For nonnegative normalized profiles with finite second moments, define and . Since , their temporal variances satisfy . In an original chosen example, an input standard deviation and recorded deviation imply . Treating that finite input as a delta impulse would incorrectly assign the full to the detector. This finite-input correction in pulse-detector calibration concerns standard deviations; a universal subtraction rule for arbitrary FWHM values does not follow. Negative ringing also invalidates the nonnegative-profile interpretation used for the variance identity.
NIST's primary procedure illuminated the detector with a pulse much shorter than the detector response and characterized detector, cable and oscilloscope together at the relevant gain and signal levels.[ref]
Calibration Service for Low-level Pulsed-Laser Radiometers at 1.06 µm: Pulse Energy and Peak Power by Rodney W. Leonhardt. §§6.1–6.2; Appendix C.1–C.2, printed pp. 36–37, Figure C1 and measurement procedure
Such a known input breaks the optical tail and detector-response ambiguity described by the parent article.In the frequency domain, the same model is . Division can estimate where the input spectrum is known and sufficiently nonzero; small input components amplify measurement noise. A short reference pulse is useful because it excites a broad frequency range, but detector linearity, baseline, area coverage and reference uncertainty still need checking.
Laplace transform Created 2026-09-24 Updated 2026-10-14
The unilateral Laplace transform of a function is the integral transformHere is a complex number, is its real part, and is the imaginary unit. The exponential function factor weights the history, while probes its oscillations. The integral starts at zero, so it uses only the history from that starting time onward. This section concerns ordinary functions; their value at the single endpoint does not change the integral. See MIT 18.03SC, definition and elementary examples.
The Laplace transform is useful because it packages an entire time history into a function of : a derivative becomes multiplication by together with the initial value, and a convolution becomes a product. Thus a linear differential equation can become an algebraic equation that already remembers its initial value problem. The worked example below shows both descriptions of the same response.
If is a piecewise continuous function and has exponential order , then its defining integral is absolutely convergent for . This is a sufficient condition; the actual Laplace convergence region may be larger than the bound obtained from a chosen . [ref]
https://ocw.mit.edu/courses/18-03sc-differential-equations-fall-2011/fff4420903d82c5c5c483e54566bc5ec_MIT18_03SCF11_s27_2text.pdf. MIT 18.03SC, domain and growth conditions
.The bound has a short explanation. For sufficiently large , , so , whose tail integral is finite for . The finite initial interval is covered by piecewise continuity.
Three calculations make the convergence condition concrete. For the input , evaluate the finite-history integral first:At the finite-history integral is . For the exponential function input , the same calculation replaces by , givingIn particular, is allowed for this decaying input: its weighted integral is . For the sine input, Euler's formula gives ; linearity then yieldsThe Laplace convergence region is part of the answer. For example, has an analytic continuation to , but the defining integral for the input diverges there. The sine calculation is also developed in MIT 18.03SC, further elementary transforms.
To see why the initial value appears, suppose is an absolutely continuous function on every finite interval , with its right one-sided limit. At the chosen , assume and are Lebesgue integrable functions and . The Laplace transform of a derivative is thenFor example, exponential order bounds on both and guarantee these conditions whenever exceeds both growth bounds. The initial value is the lower-end boundary contribution of integration by parts.
Consider the initial value problemWrite . The Laplace transform of a derivative and linearity give for . A partial fraction decomposition therefore givesWe recognize the two elementary Laplace transforms already computed. Directly verify the result: its derivative is , soThis verifies both the ordinary differential equation and the initial value, and shows that the resulting bounded function has the Laplace transform used above. The response rises from zero toward : at that value the input balances the term . The general method is described in MIT 18.03SC, solving initial value problems.
The same solution is a convolution. For functions defined on , the unilateral convolution isThe main convolution article integrates over the whole real line; applying a causal extension by zero to both functions makes its formula identical to this one. Nonzero contributions require both and , hence . If and are Lebesgue integrable functions on , the convolution theorem for Laplace transforms statesFor piecewise continuous functions of exponential order and , it holds throughout . The weighted absolute double integral factors into the two finite weighted absolute integrals; Fubini's theorem therefore permits exchanging the order, and setting separates the product. [ref]
https://ocw.mit.edu/courses/18-03sc-differential-equations-fall-2011/0d4d90053f2bb24f7551c78e2d1b21a2_MIT18_03SCF11_s30_5text.pdf. MIT 18.03SC, convolution and system response
.For the linear time-invariant system starting at zero, the convolution kernel is its impulse response for , extended by zero for . With the Heaviside step function input, for , the accumulated response isThus on is both the algebraic solution and the Laplace transform of a finite-history convolution. Each past input contributes an exponential function that decays with its age , which makes the two descriptions easy to connect.
Finally, compare the Fourier transform convention . If is the causal extension by zero of , define . Whenever is a Lebesgue integrable function,A vertical slice of the Laplace transform is therefore the Fourier transform of the zero-extended, weighted input. Positive damps its positive-time history. A finite window function instead gives and ; this approaches in the Laplace convergence region. Setting directly requires an integrable zero-extended input: the input fails that condition, even though its Laplace transform exists for every .
The history of the Laplace transform spans several stages. Schiff's historical summary notes that Laplace's 1812 treatise acknowledged earlier work on integral transforms and describes later development of the modern Laplace transform method. [ref]
https://oldversion.stu.edu.vn/uploads/documents/170509-091205.pdf#page=9. Schiff, The Laplace Transform: Theory and Applications, historical summary, pp. x–xi
. Linear filter 2026-10-13
A linear filter obeys the superposition principle: filtering gives . Many familiar examples are also linear time-invariant systems, represented by an impulse response and convolution. Linearity alone does not imply time invariance: multiplying by the index is linear but changes its behavior when the same input is shifted.
The moving average is a finite impulse response example implemented by arithmetic; a band-pass filter can instead be built from a series RLC circuit. Their frequency responses explain which oscillations pass through. Choosing a filter means choosing how much amplitude, timing and detail may change, not simply removing every visible fluctuation.
Linear time-invariant system 2026-10-13
A linear time-invariant system combines two properties. Linearity means that the output from a linear combination of inputs is the same linear combination of their outputs. Time invariance means that shifting an input by an integer delay shifts its output by exactly that delay. The operation has no preference for a particular time origin.
For discrete time, write the unit impulse as at and zero otherwise, a Kronecker delta. Its response is the impulse response. A finite input can be decomposed into shifted impulses, givingThe superposition principle supplies the sum and time invariance supplies the shifted copies of . Infinite sums need convergence assumptions; for a bounded input and an impulse response with absolute summability, the discrete convolution converges absolutely. For a physical system with stored initial energy, this construction describes the response with zero initial state; a separate free response accounts for nonzero initial conditions.
The gain is reuse. Measure or calculate one impulse response, and the convolution predicts the response to every allowed signal without solving a new dynamical problem each time. Alternatively, the frequency response predicts how each oscillatory component changes. [ref]
https://ocw.mit.edu/courses/res-6-007-signals-and-systems-spring-2011/0400ba59406d52d94c079d99928156ee_MITRES_6_007S11_lec04.pdf. Oppenheim, lecture 4: convolution from shifted impulses
. Optical energy outside a time gate 2026-11-05
Optical energy outside a time gate is the radiant energy excluded by a specified ideal temporal acceptance set . For a nonnegative radiant power profile of finite positive total energy,The time-integral definition is the radiometric one.[ref]
International Lighting Vocabulary by CIE. entry17-21-041, note1, radiant energy as the integral of radiant flux
This observable needs a gate boundary but no fitted separation into a main field and an optical pulse pedestal.For an original three-pulse example, let an optical prepulse, main pulse and optical postpulse carry , and respectively, with disjoint supports. A gate containing only the main pulse admits of , so . Widening that gate to include the postpulse reduces the fraction to . The optical waveform has not changed; the admitted observable has.
For a translated interval with continuous boundary values,Unequal power at the boundaries produces first-order sensitivity to a timing shift. Equal boundary values eliminate this derivative but need not eliminate higher-order loss; quadratic energy loss from centred Gaussian gate timing error gives an existing example.
The total-energy denominator must cover the excluded light too. If the acquisition window misses an unknown tail, pulse-energy interval from incomplete tail measurements supplies conditional bounds rather than an exactly known fraction. A detection time gate on an electrical detector trace also includes the detector impulse response and is not automatically an ideal gate on incoming optical power. A characterized optical response and a stated detector baseline subtraction are needed to compare the two.
Optical tail and detector-response ambiguity 2026-11-05
Optical tail and detector-response ambiguity arises because a measured temporal trace combines the optical waveform with the receiver's dynamics. In a calibrated linear time-invariant system,where is incident radiant power and the unit-area detector impulse response. One trace does not generally identify both unknown functions. The parent bounding unobserved optical energy with an exponential tail model gives an impulsive-input example; two finite-width profiles provide another exact ambiguity.
Define for , and zero otherwise. Consider model A with optical power and detector response , and model B with these two time constants exchanged. By commutativity of convolution, both give exactlyTheir optical energies after are nevertheless and . For original chosen , those are about and . Identical recorded tails therefore coexist with very different true late optical energy.
Different optical tails and detector responses can produce the same measured pulse
. Original unit-area exponential response models. Model A has a2ns optical time constant and10ns detector time constant; model B exchanges them. Both incident pulses have100nJ total energy. The measured convolution is identical despite different optical energy after20ns. Source. Details.Known-input calibration of a pulse detector supplies information missing from this inverse problem. NIST measured the detector/cable/oscilloscope response with optical excitation much shorter than the response before calculating waveform distortions.[ref]
Calibration Service for Low-level Pulsed-Laser Radiometers at 1.06 µm: Pulse Energy and Peak Power by Rodney W. Leonhardt. Appendix C.1–C.2, printed pp. 36–37, Figure C1 and bandwidth-correction procedure
The example above is an independent mathematical construction. A fitted electrical decay constant alone cannot establish a global optical-tail envelope. Past exam of the mathematics course of the University of Cambridge 2007 ia Paper 2 7B i a Solution 2026-10-14
Inserting the Dirac delta forcing into the integral gives the impulse responseIt is zero before the impulse and obeys the homogeneous equation afterward. Integrating the equation across zero gives , exactly the jump in this formula. Thus the formula also verifies the differential equation as a distribution; assigning a particular value at the jump does not affect that distribution.
Past exam of the mathematics course of the University of Cambridge 2007 ia Paper 2 7B i Solution Created 2026-09-24 Updated 2026-10-14
Multiply the first-order linear differential equation by the integrating factor . ThenIf in the remote past, then there. Integration from gives the necessary formulaWhen this integral exists and tends to zero as , differentiating verifies the equation and the past condition. Two such solutions differ by , which diverges at unless , proving uniqueness. This is the causal response of a first-order relaxation equation, a convolution with its decaying impulse response.
The phrase “general function” implicitly requires compatibility with the past condition: it does not guarantee existence for arbitrary . A sufficient condition is bounded forcing with as ; after setting , the integral is bounded by the supremum of before . For example, gives , so no solution has the stated past limit. Both forcings below vanish in the past and meet the intended causal condition, the impulse being interpreted distributionally.
Past exam of the mathematics course of the University of Cambridge 2009 ib Paper 3 6A Solution Created 2026-09-24 Updated 2026-10-14
With , the causal exponential is integrable and its Fourier transform isFor the pendulum system, a transfer function is the Fourier transform of its causal impulse response, equivalently the multiplier relating the transformed forcing to the transformed zero-initial-data response. Transforming derivatives givesPartial fractions therefore giveThe exponential transform identifies the causal response as for and zero for . It solves the homogeneous equation for , with and , the jump required by a unit impulse. The forcing is understood as switched on at zero; its transform is , and convolution with gives, if the time response is wanted,This has both stated initial values equal to zero.
The convolution theorem gives the causal responseDefine the integrated impulse response, for , byDirect differentiation gives and . ThusIn particular, after switch-off the answer isThe response and its first derivative are continuous at both switching times, and the post-pulse motion is a freely decaying damped harmonic oscillator. The expression described as valid for in the paper is understood for ; before the pulse the causal output is zero.
The Fourier transform of a derivative is times the transform under the stated convention. Transforming the linear ordinary differential equation givesThe applied force is , with the Heaviside step function, so . Partial fractions giveUsing the transform pair yieldsIts value and first derivative both vanish at , so the joining introduces no spurious Dirac delta terms. Equivalently, this is the convolution of the force with the causal impulse response .
Convolution describes the response of a linear time-invariant system to an arbitrary input. If is its impulse response and its input,This is a weighted sum of responses to shifted impulses. For integrable functions the operation is commutative and associative. A causal system has for , restricting the integral to past inputs. With the Fourier convention , the convolution theorem gives .
For example, an RC low-pass frequency response has and , where is the Heaviside step function. Fast input variations are smoothed. The same mathematics describes optical blurring by a point spread function and many other linear response measurements.
Deconvolution tries to recover from measured and known . In noise-free data one formally sets where . Zeros of lose corresponding information; small values amplify measurement noise. If the measured spectrum is , the direct estimate has error , which can be very large at frequencies strongly suppressed by the instrument. An inverse is therefore not automatically unique or stable.
One regularized spectral deconvolution reconstruction isThis minimizes at each frequency and limits noise amplification, at the cost of bias and lost resolution. Choosing the regularization requires assumptions about noise and the desired signal; deconvolution cannot restore components that the data do not determine without such additional information.
Paul D. Hale 2026-11-05
Paul D. Hale is a metrology researcher named with Tracy S. Clement and Dylan F. Williams on a 2001 NIST paper about optical receiver frequency response. It compares frequency-domain optical heterodyne detection with time-domain measurements using an oscilloscope, including corrections for the electrical connection and finite optical stimulus.[ref]
Frequency response metrology for high-speed optical receivers by Paul D. Hale and others. Byline, p. 1 introduction and p. 3, Time-domain measurements
An oscilloscope trace need not be the receiver's isolated impulse response. In an original idealized model of linear time-invariant systems, let be the receiver impulse response, the optical pulse envelope and the readout impulse response. Ignoring mismatch for this illustration, the measured waveform is the convolutionA broader measured pulse can therefore reflect the receiver, the stimulus or the readout. If all three envelopes are normalized Gaussian functions, with independent convolution widths, their variances add:For illustrative widths , and , the inferred receiver width is , rather than . These are chosen model values, not results reported by Hale.
The example motivates characterizing the stimulus and readout as well as the specimen. Dividing by where that product is nearly zero also amplifies measurement noise, so a formal Fourier transform inversion does not guarantee a reliable corrected response. This is why measurement uncertainty belongs alongside the quoted frequency response.
Pulse duration 2026-11-05
Pulse duration quantifies a pulse's temporal extent using a stated observable and width convention. A common optical convention is the full width at half maximum of the background-subtracted radiant power profile. The Ansys source documentation explicitly defines its PULSELENGTH parameter as the power-profile FWHM, rather than the width of the electric-field amplitude.[ref]
Plane wave and beam source - Simulation object in Ansys Optics documentation. Frequency/Wavelength tab, Standard source PULSELENGTH definition
For an original example, choose a triangular power pulseIts nonzero support extends from to , giving total support width . Its half-maximum crossings occur at , giving a power FWHM of only . Neither number is wrong when its convention is specified. The pulse energy shape factor additionally relates a chosen width to integrated energy and peak power.
A fast photodetector and oscilloscope record an electrical response to an optical pulse. For a linear response model, the recorded trace is a convolution with the instrument's impulse response; a slow response can broaden the measured feature. The readout width need not equal the optical width. State the observable, background treatment and instrument response when reporting a duration. Pulse energy baseline correction affects where the half-maximum threshold lies, while Gaussian pulse energy and peak power treats the conversion for a specific power-profile family.
Quadratic energy loss from centred Gaussian gate timing error is the leading decrease in collected energy when a symmetric gate is displaced slightly from the centre of a Gaussian pulse. At the optimum the first-order change vanishes, but the second-order change is negative. The Gaussian pulse time-gate energy fraction gives the exact displaced-gate integral; here the local loss and its effect on jitter are derived explicitly.
Let be the centred energy-normalized pulse profile, let , and setThe Leibniz integral rule gives . Since is even and ,The Taylor expansion therefore yieldsThis is an absolute fraction of the full pulse energy. The relative loss compared with the centred gate is instead .
For a gate as wide as the power FWHM , and . An offset gives leading loss , or about percent of the centred gate's collected energy. Neither the full pulse energy nor the gate width has changed.
A zero mean offset does not eliminate this loss. For a sufficiently narrow random offset with mean and variance , the leading expectation isIf has a centred normal distribution, the quadratic model also gives . At , the leading mean loss is and this standard deviation is . These formulas neglect fourth-order effects; they are local approximations, not bounds for large timing excursions.
Exact Gaussian gate capture and its local quadratic loss: a zero first derivative does not remove timing sensitivity.
Details. An apparatus check scans the gate delay about its optimum and compares the measured decrease with the model, while monitoring gate width and the pulse. A gate on the detector's electrical output need not act directly on optical power: the detector impulse response and readout convolution must be included. NIST's impulse-response measurements illustrate that distinction.[ref]
Ratiometric cancellation with matched signal and reference filters preserves a resistance ratio despite changing excitation when both paths apply the same dynamics to the shared electric current. Matching only the steady gain is insufficient during a transient.
Let constant sensor and reference resistances be , and let both paths be linear time-invariant systems with impulse responses . With consistent initial conditions, their filtered electric potential differences arewhere is convolution. If , simultaneous sampling gives whenever the denominator is nonzero. Arbitrary unequal stored initial states need not cancel. Nor can a time-varying generally be pulled outside the convolution.
For unit steady gains, write after settling at . Define and . ThenThis displays exactly which excitation component survives. For small fluctuations the fractional residual is , so both amplitude and timing differences between the transfer functions matter.
As an original transient example, step the excitation up by ten percent from a settled state. Two first-order low-pass filters with time constants and give, for ,At the reading is high by approximately , although both filters have the same final gain and the error tends to zero. Setting both time constants to cancels this particular excitation step at every time. Sampling skew after matched ratiometric filters can still break simultaneous cancellation even with identical hardware.
The primary ADS1248 experiment used a resistance decade box, a excitation and a reference. Reference-only filtering produced signal-dependent noise; matching the signal and reference paths substantially reduced that dependence. The report provides the circuit and noise-versus-input plots, rather than merely recommending a common nominal cutoff.[ref]
Ratiometric measurement 2026-11-05
A ratiometric measurement infers a quantity from a ratio of two measured signals chosen to share an unwanted multiplicative variation. The useful question is which inputs actually share that variation: a reference resistor error or a change in the sensor itself generally survives the cancellation.
In a shared-excitation resistance ratio measurement, a current source passes the same electric current through a sensor of electrical resistance and a reference resistor . Their electric potential differences are and . An ideal normalized analog-to-digital converter reading is thereforeThe current source need not have a perfectly constant output for this cancellation, provided both measurements sample the same electric current, the denominator is nonzero, and the converter stays within its operating ranges. This is a standard arrangement for a resistance thermometer.[ref]
A Basic Guide to RTD Measurements by Joseph Wu. §2.1.3, pp. 10–11, shared-current resistance measurement
For an original ideal example, take , and . Then , and . Increasing by gives and : the ratio remains . If the converter instead uses an independent fixed reference and the calculation assumes the original , the inferred electrical resistance becomes .
Shared excitation cancels in a resistance ratio; a fixed independent reference retains the excitation error. Original ideal calculation, not measured data.
Details. The reference-resistor error in ratiometric resistance measurement remains even with perfect shared excitation. If the actual reference resistor is but the calculation uses its nominal value, thenThus a reference error makes the nominal estimate of a true sensor about . Reference accuracy and its variation with temperature still matter.[ref]
Nor does the ratio remove sensor self-heating in a ratiometric resistance measurement. Joule heating dissipates , which is in the example. A temperature rise changes the actual electrical resistance of a resistance thermometer; the ratio then measures that changed resistance. Reducing the electric current or comparing several currents can reveal this physical effect.[ref]
The law of propagation of uncertainty makes the role of covariance explicit. For small perturbations of nonzero mean signals, the first-order measurement uncertainty of obeysThe contribution from a shared excitation fluctuation cancels through the covariance term. Treating the two signals as independent random variables would discard that cancellation. Other errors need their own inputs in the complete model.[ref]
For time-varying excitation, ratiometric cancellation with matched signal and reference filters requires matching dynamics as well as shared wiring. With constant resistances and identical linear time-invariant systems of impulse response , the filtered signals are and , so their ratio is still wherever defined. Here denotes convolution. Different filters or different sampling times can leave an excitation-dependent error.[ref]
RTD Ratiometric Measurements and Filtering Using the ADS1148 and ADS1248 Family of Devices by Luis Chioye. First-page abstract and low-pass filter design discussion, matching input and reference filters
A simple proposed bench test first replaces the sensor by a stable calibrated resistor, sweeps the electric current within the instrument limits, and records both electric potential differences and their ratio. That separates electrical cancellation from changing sensor temperature. Repeating with a resistance thermometer in a stable bath then tests Joule heating; changing the reference resistance or one filter tests the predicted failure modes. These are proposed checks of the model, rather than reported experimental results.
Resistor-capacitor equilibrium noise 2026-10-18
Connect one physical resistor across an ideal lossless capacitor , with no applied source and an ideal readout that draws no electric current. Represent the resistor by its noisy Thévenin equivalent. The resulting RC low-pass frequency response gives the stationary capacitor voltage power spectral densityIts mean square follows by the effective noise bandwidth calculation:This is also the equipartition theorem: the mean capacitor energy is . Raising makes the low-frequency spectrum taller and its width narrower in exactly compensating proportions. It changes the equilibration time , not the final variance.
The integral to infinity belongs to the ideal classical model. For a physical electrical circuit, assume thermal equilibrium, linear components with negligible extra dissipation, and a corner far below the frequencies where parasitic effects, frequency-dependent electrical resistance, or invalidate the model; the omitted high-frequency tail must be negligible. A finite-bandwidth instrument measures only part of this variance. Its input capacitance contributes to the total , and its finite input electrical resistance introduces both loading and its own thermal electrical noise.
For and , the predicted equilibrium variance is and the root mean square voltage is . At , and . At , and ; the equilibrium root mean square voltage is identical.
To obtain the growth curve, prepare exactly and connect the resistor at while maintaining its temperature. The RC low-pass filter's causal impulse response is for . Classical ideal white noise with two-sided power spectral density givesThe factor here is the two-sided time-domain noise intensity; the equilibrium spectral integral above used the one-sided . They give the same long-time limit. The variance approaches equilibrium with time constant , although a deterministic initial voltage decays with time constant . If the capacitor already starts in thermal equilibrium, its initial variance supplies the missing exponentially decaying term and the total variance stays constant.
Sampling skew after matched ratiometric filters is the timing difference between the signal and reference samples in a ratiometric measurement, after their analog paths have the same response. Shared wiring and matched filters cancel excitation at the same effective time; they do not make two different times interchangeable.
For constant sensor and reference resistances, let the common filtered excitation be , where is the common impulse response and denotes convolution. With consistent initial conditions, the two filtered electric potential differences are and . If the sensor is sampled at but the reference at , the measured ratio isBoth denominator factors must be nonzero. The sampling instants here mean the effective acquisition times; conversion-result arrival times need not be those instants. Ratiometric cancellation with matched signal and reference filters treats the equal-time cancellation, supported by the primary circuit report's matching requirement.[ref]
RTD Ratiometric Measurements and Filtering Using the ADS1148 and ADS1248 Family of Devices by Luis Chioye. Abstract and §2, matching the signal and reference responses
For positive differentiable and small skew, expanding the logarithm givesA later reference sample during a rising excitation therefore makes the inferred resistance low. The relevant rate is the fractional slope , not the absolute slope alone. A timing-skew bound for a ratiometric measurement can express a worst-case requirement using a bound on this logarithmic slope.
For an original local example, suppose over the acquisition window, with and . Then the exact scale error is . The small-skew estimate is . Doubling the common amplitude leaves both errors unchanged; reversing the sample order changes their sign to first order. This is a stipulated short-window excitation model, not an instrument-performance claim.
A focused bench check replaces the sensor with a stable resistor, imposes a controlled excitation change, and compares simultaneous acquisition with deliberately delayed reference sampling. Recording the excitation on an oscilloscope supplies its fractional slope. Repeating on a settled plateau separates timing error from reference-resistor error in ratiometric resistance measurement and other steady scale errors.