Chirped pulse amplification 2026-10-18
Chirped pulse amplification increases an optical pulse's energy while keeping its peak power lower during amplification: stretch the pulse, amplify it, then compress it. A chirp is a changing instantaneous frequency. Stretching separates the arrival times of different frequencies; pulse compression brings their contributions back together. The gain medium supplies energy, whereas the compressor concentrates the surviving energy into a shorter time.
Donna Strickland and Gérard Mourou demonstrated chirped pulse amplification at Rochester in 1985. Their experiment used an optical fiber, a regenerative amplifier and a diffraction grating compressor.[ref]
Compression of amplified chirped optical pulses by Donna Strickland and Gérard Mourou. Strickland and Mourou, corrected December 1985 paper, pp.219–221
The useful idea is to arrange where the large peak power occurs. Lower light intensity in the amplifier reduces unwanted self-focusing and self-phase modulation; the compressed output can still drive strong nonlinear optics. Stretching does not remove every damage mechanism, and compression does not manufacture energy.
For an isolated fluorescent molecule at displacement from the scanning optical focus, write for relative excitation light intensity and for the fraction of its collected emission passed by a centred detection pinhole of radius . The expected response, apart from a common brightness and collection factor, isHere is position in the detection-pinhole plane and is the emitted light intensity distribution there conditional on collection, with units of inverse area. This point spread function normalization retains throughput: is a fraction, not a curve rescaled to have peak one. The product expresses excitation followed by detection; it is an intensity/probability product, not multiplication of coherent wave amplitudes from different molecules. [ref]
Confocal microscopy (chapter manuscript) by Brad Amos and others. Manuscript p. 16, Fig. 4 discussion; Appendix §5, p. 37, Eq. A17: illumination-times-detection response
Assume linear, unsaturated fluorescence, independent emitters whose light intensities add, a stationary specimen, fixed collection efficiency and quantum efficiency, and negligible changes from scattering, absorption or bleaching during a scan. Different excitation and emission wavelengths generally give different excitation and detection responses. For a sufficiently small pinhole, is approximately its area times at the centre; this is the familiar excitation-times-detection point spread function. It is not universally the square of one point spread function. A spatially invariant response further allows the image to be expressed as a convolution with the emitter distribution; depth-dependent optical aberrations can invalidate that approximation.
For an explicitly synthetic axial example, put and choose an on-axis excitation , inspired by a Gaussian beam. Stipulate a circular Gaussian function for the detection-plane light intensity, with standard deviation . In dimensionless coordinates , put . ThenThe expression for follows by integrating over a disk using polar coordinates. The assumptions specify a toy model with matched axial scales; its parameters are not a calibration for a real objective optical lens. It omits Airy disk rings, vector diffraction, and unequal excitation and emission wavelengths.
Synthetic axial response: narrower pinholes reduce throughput and suppress defocus
. Original Gaussian toy model, not measurements. The left panel keeps a common signal scale; the right divides each response by its own peak to compare widths. Here is a radius in units of detection-plane Gaussian standard deviation, not an Airy-unit diameter. The dashed reference is the same scanned excitation with all collected emission accepted, not conventional uniform widefield illumination. Both panels retain nonzero out-of-focus tails. Details.For a vanishingly small pinhole, the peak-normalized synthetic response tends to , whose full width at half maximum is . With all collected emission accepted it tends to , of width . Meanwhile as the pinhole closes. The narrower normalized curve therefore accompanies a vanishing detected signal; peak normalization must not conceal that loss.
Error function Created 2026-09-24 Updated 2026-10-14
The error function records the signed area under a Gaussian function between zero and a variable endpoint:For a negative real number , reversing the integration limits makes this integral negative. The normalization uses the Gaussian integral: the full area of is , so its positive half contributes one after multiplication by . The same definition extends to a complex number along any path from zero to , giving an entire function.[ref]
For example, , , and . A finite positive endpoint captures only part of the positive Gaussian integral; approaches one as but never reaches it at a finite real .
The useful idea is to name a recurring integral once instead of carrying it through every calculation. The error function and the normal distribution express probabilities and quantiles through this area, while an error-function diffusion front describes how diffusion smooths a sharp jump. The complementary error function retains the small area left in the tail.
The fundamental theorem of calculus givesThus the real-axis error function is strictly increasing, with values in . Its integrand is an even function, so the error function is an odd function, . The derivative also gives : the curve is concave for and convex for . These real-axis properties do not imply boundedness throughout the complex plane; the existing quadrant asymptotics of the error function describe a different behavior in other directions.
Error function and the normal distribution 2026-10-14
For a standard normal random variable , its standard normal distribution function isThe change of variables and the symmetric distribution of the standard normal random variable give the second expression. For with , standardization of a normal random variable then givesIn particular, the intervals within one, two, and three standard deviations have calculated probabilities about , , and . These values depend on a normal distribution; they are not universal coverage guarantees for an arbitrary random variable. This is the direct connection between a Gaussian function area and the familiar central intervals.
For a small upper-tail probability, use the complementary error function directly:Computing this as instead can lose the tail to catastrophic cancellation. The Gaussian tail bound gives another useful estimate without requiring an exact error function value.
Even function Created 2026-09-24 Updated 2026-11-05
A function on a domain invariant under is even when . Its graph is symmetric about the vertical axis. Examples include , and the centered Gaussian function . On a symmetric finite interval, an integrable even function satisfies .
When a Taylor series about zero represents the function, its odd coefficients vanish: substituting and comparing coefficients gives . The analogous statement holds for a Laurent series on an annulus centered at zero. Parity does not itself guarantee such a series representation. For instance, the even smooth function , extended by zero at zero, has every Taylor coefficient zero there while being positive away from zero.
Extracted-ion window capture fraction 2026-11-05
An extracted-ion window capture fraction is the fraction of a particular ion peak's integrated mass-coordinate signal retained by an extracted ion mass window. For a nonnegative signal-density model and window ,assuming the denominator is finite and positive. This is a fraction of the specified peak model, not necessarily a fraction of analyte molecules or of the entire total ion current. The extraction window selects which mass-coordinate signal enters a profile.[ref]
Extracted ion profile in IUPAC Gold Book. Entry 12410, selected mass-coordinate values and time-dependent profile.
An original Gaussian function model makes window-capture sensitivity to mass offset explicit. Let the peak center be displaced by from the nominal window center, with standard deviation and symmetric half-width . If is the standard normal distribution's cumulative distribution function,At zero offset and , the retained fraction is approximately . Shifting the peak center to the upper window boundary, , reduces it to approximately . The model's total peak area has not changed; the selected fraction has.
A wider window admits more of this peak but can also admit another ion. The measured window sum can therefore increase for two different reasons: greater target capture or added interference. They cannot generally be distinguished from the summed trace alone.
The Gaussian shape is a stipulated teaching model, not a universal instrument response. Real peak asymmetry, finite recorded ranges, background and overlapping signals can change the fraction. Mass resolving power and mass-coordinate accuracy remain instrumental properties; a software window only selects from the information available.
Fluorescence instrument response 2026-10-14
A fluorescence instrument response is the distribution of recorded delays for an effectively prompt optical signal. Finite excitation-pulse width and timing variation in the photodetector and electronics contribute. With a normalized response , intrinsic fluorescent photon rate , and background rate , the expected trace isFit a candidate decay after this convolution with the measured response; treating the broadened leading edge as the intrinsic decay can bias fluorescence lifetime. The accessible technical note describes measuring prompt scattered excitation with a nonfluorescent scattering sample.[ref]
Time-Correlated Single Photon Counting (technical note v. 2.1) by Michael Wahl. Michael Wahl, Time-Correlated Single Photon Counting, v. 2.1, p. 3: scattering-medium response measurement and iterative reconvolution
Synthetic fluorescence lifetime decay broadened by an instrument response
. Original stipulated model, not measurements: for and zero otherwise; is a normalized Gaussian function of standard deviation centred at zero; the background is in the common signal units. The left panel compares intrinsic and convolved traces; the right shows how an unremoved background flattens the tail on a logarithmic scale. Negative delays come from the stipulated timing response about the pulse reference, not emission before excitation. Only the instrument-response curve is rescaled to unit peak for display. Details. Fluorescence localization precision Created 2026-10-25 Updated 2026-10-31
The precision of a fitted single-emitter position is distinct from its diffraction-broadened point spread function width. An ideal Gaussian function image of width with independent detected photons gives . Pixel size, background, model error, sample motion and drift limit practical performance; precision alone does not guarantee accuracy.[ref]
Precise nanometer localization analysis for individual fluorescent probes by Russell E. Thompson and others. Localization uncertainty with finite photon number, pixelation and background
Fourier inversion theorem Created 2026-09-24 Updated 2026-10-14
The Fourier inversion theorem makes decomposition into frequencies reversible: a complete Fourier transform, including its wave phases, determines the original function up to equality almost everywhere. With the angular-frequency conventionif and belong to the L1 space, thenalmost everywhere. The right side is a continuous representative of . If itself is continuous, equality holds everywhere, as explained by the continuous version of Fourier inversion. The integrability hypotheses ensure that both displayed integrals are ordinary absolutely convergent integrals. For arbitrary elements of the L2 space, the Plancherel theorem instead supplies inversion in the L2 space norm.
Each factor is a Fourier mode; the inverse integral adds them with the complex weights . The normalization is part of the recipe. In one dimension, writing ordinary frequency as gives the equivalent pairwhere . Reversing both exponential signs gives another equivalent convention, but the forward and inverse formulas must use opposite signs consistently.
For example, the Fourier transform of a Gaussian givesFourier inversion says that a weighted continuum of oscillations reconstructs this smooth Gaussian function. Narrowing the original Gaussian function by increasing broadens its frequency spectrum. This is a concrete demonstration that a sharply localized shape needs a wider range of frequencies.
Inversion is what makes a frequency calculation useful: transform a function, solve the simpler problem there, then return to the original variables. A brief proof outline is to multiply by , . The inverse integral becomes convolution with a normalized Gaussian function, an approximate identity. As tends to zero, dominated convergence gives the unregularized inverse integral, while the approximate identity recovers almost everywhere. Joseph Fourier's Théorie analytique de la chaleur (1822), Chapter IX, article 417, contains a cosine double-integral representation antecedent to this modern formula; the hypotheses above are the modern statement.[ref]
https://fr.wikisource.org/wiki/Th%C3%A9orie_analytique_de_la_chaleur/Chapitre_9. Fourier 1822, Chapter IX, article 417: cosine integral representation
Fourier support 2026-11-05
The Fourier support of a function or distribution is the support of a function of its Fourier transform, with distributional support used when necessary. For an ordinary transform, it is the closure of the set of frequencies where is nonzero. Thus a bandlimited function has Fourier support in a bounded frequency region.
Under the convention , multiplication by translates Fourier support by . Translation of in physical space instead multiplies its transform by a phase, leaving Fourier support unchanged. This distinguishes where a signal occurs from which frequencies it contains.
For example, the distribution has Fourier support . A nonzero Gaussian function has transform nonzero at every real frequency, so it has no compact Fourier support despite rapid frequency decay. Small coefficients and exact vanishing describe different properties.
Front velocity 2026-10-14
The front velocity is the propagation speed of the earliest boundary of a newly introduced disturbance's support. It asks when an initially unaffected observer can first respond, whereas group velocity asks how a narrow wave envelope translates. A detector threshold defines a practical arrival time, but can miss arbitrarily small earlier responses; a packet peak is another distinct timing convention. In a causal dielectric model, a high-angular frequency contour argument gives exactly zero field for , even when phase velocity exceeds . This is a statement about that model's relativistic causality, not a universal identification of group velocity with front velocity.[ref]
Wave-Front Propagation by Richard Fitzpatrick. equations 871–873 and the paragraph following equation 887: zero field ahead of the causal front
For the stipulated Klein-Gordon equation with compactly supported real Cauchy data, front velocity is bounded by , and is the model's maximal speed of influence. A short energy method outline usesIntegration outside an expanding interval shows that zero initial energy there remains zero. Thus initial support in cannot influence before . The positive energy density includes the restoring term : this adds oscillation behind the front without extending its domain of dependence. A particular disturbance may fail to excite the leading boundary, so the maximal speed is not a promise of a detectable response for every source.
A Gaussian function is nonzero arbitrarily far away, so the Gaussian envelope in a Klein-Gordon medium has no sharp initial support boundary. Its small distant tails are already in the initial data. Likewise, keeping only a narrow interval of the frequency spectrum cannot reproduce an exact abrupt onset. Cutting off a Gaussian tail changes its Fourier transform and the accompanying initial velocity; it is a different initial-value problem. The exponential initial-velocity tail for the Klein-Gordon equation is another concrete example of a pre-existing tail outside the main disturbance.
The water-tank measurement in phase velocity records free surface elevation with calibrated resistance probes and uses a ruler and stopwatch for an independent check. The inspected protocol calls the front or back of a group a timing feature. That visible edge establishes an envelope transit estimate, not the first nonzero disturbance in the sense of front velocity.[ref]
Surface Waves Kinematics (MIT 2.016 Hydrodynamics) by Massachusetts Institute of Technology, 2.016 course staff. p. 1, Equipment; p. 2, task 2; p. 3, tasks 5–6: apparatus, calibration and group-feature timing
A proposed additional control would repeat the transit fit at several detection thresholds and train durations, using matched probe calibration and the same sampling rate. Dependence on the threshold diagnoses wave envelope reshaping or limited sensitivity; records should be compared before reflections return. Such a test could expose limitations of a group velocity estimate, but would not establish an exact causal front or validate the stipulated Klein-Gordon equation for water waves. Gabor filter Created 2026-10-13 Updated 2026-10-24
A Gabor filter has a kernel formed by multiplying a Gaussian function by a sinusoid or a complex oscillation. In two-dimensional image processing, its orientation and spatial frequency select local image structure; evaluating the kernel's translated dot product with an image is spatial filtering. The real even example under signed spatial filter model of a simple cell uses a cosine.
There is experimental motivation for this family without making every simple cell an exact Gabor filter. Jones and Palmer fitted two-dimensional Gabor filters to measured spatial and spectral response profiles of simple cells in cat cortex and compared independently estimated parameters as a test of spatial linearity. Their reported residuals supported the approximation in that dataset. The chosen parameters and orientation tuning curve in this article are not extracted from their measurements. [ref]
https://pubmed.ncbi.nlm.nih.gov/3437332/. Jones and Palmer, An evaluation of the two-dimensional Gabor filter model of simple receptive fields in cat striate cortex (1987), primary abstract
Gaussian beam Created 2026-10-05 Updated 2026-10-14
A fundamental Gaussian beam is an ideal beam of light whose transverse wave amplitude has a Gaussian function profile. Here consider a circularly symmetric beam in vacuum, with propagation along , two transverse coordinates , and radius from the optical axis. With the beam waist at , total power , and vacuum wavelength , its time-averaged light intensity, meaning irradiance in , isHere is the minimum beam radius, and is the Rayleigh range. Far from the beam waist, with beam divergence half-angle . These are the fundamental circular Gaussian beam laws within the scalar paraxial approximation, appropriate when and the beam divergence is small. The underlying envelope solves the parabolic wave equation exactly; this does not make it an exact vector solution of Maxwell equations. [ref].
The radius convention matters. Writing for the complex wave amplitude envelope, the same is the wave amplitude radius and the light intensity radius:At these ratios are and , respectively. The light intensity radius is instead . None of these radii is a sharp edge: the ideal Gaussian function has nonzero tails at every finite radius. Kogelnik and Li explicitly use the wave amplitude radius in their fundamental-mode treatment. [ref]
https://dielslab.unm.edu/sites/default/files/Kogelnik66_0.pdf. Herwig Kogelnik and Tingye Li, Laser Beams and Resonators, Applied Optics 5, 1550–1567, 1966, §3.2
.For a numerical example, take vacuum wavelength and beam waist radius . Substitution gives Rayleigh range and far-field beam divergence half-angle . At , the beam radius is and the on-axis irradiance is half its waist value. At the same wavelength, halving the beam waist radius to quarters the Rayleigh range to and doubles the beam divergence half-angle to . At fixed power, that smaller beam waist also quadruples the peak irradiance.
Gaussian beam radii at 632.8 nm: a smaller beam waist gives a shorter Rayleigh range and greater beam divergence
. Details. The contours in the left panel are in a plane through the optical axis; they mark an light intensity level, not an outer boundary. The right panel compares the exact model radii with the far-field asymptotes . The horizontal and vertical axes use different length units, so the drawn slopes are not physical angles.
The normalization expresses conserved power during free propagation. In transverse polar coordinates, an annulus has area , soA proof outline is the substitution in this integral. Spreading reduces peak irradiance as while increasing transverse area as , leaving power unchanged. In particular, the disk of radius contains , or , of the total power; the local light intensity at its rim is only of the on-axis light intensity. These are different quantities.
The left panel compares normalized wave amplitude magnitude and irradiance; the right panel integrates the transverse area to show enclosed power. For an ideal absorbing circular aperture of radius centered on the optical axis, the same fraction gives the power passing the aperture at that plane. An aperture of radius clips about of the incident power; radius clips only , or . After clipping, extra diffraction means the transmitted field no longer obeys the unmodified ideal Gaussian beam law. Every finite aperture cuts some ideal tail. Kogelnik and Li distinguish their large-aperture beam analysis from their finite-aperture diffraction analysis. [ref]
https://dielslab.unm.edu/sites/default/files/Kogelnik66_0.pdf. Kogelnik and Li, 1966, §§3–4
.The useful tradeoff is that a small bright spot cannot remain narrow indefinitely. An optical lens can create a smaller beam waist, but diffraction then makes the beam spread faster. The particularly simple relation ties localization directly to beam divergence. A proof outline for the propagation law starts with . The parabolic wave equation separates into two transverse factors, and a Gaussian integral in each coordinate givesHere is dimensionless and is the wavenumber; the carrier convention is , with angular frequency . Taking the squared complex modulus gives the stated and its light intensity scaling. Each transverse factor contributes , explaining the prefactor here and the different prefactor in the preserved Gaussian beam with one transverse coordinate.
Historically, Gaussian beam theory developed alongside early laser resonator theory and lens-guided transmission. In their 1966 review, Kogelnik and Li credit Boyd and Gordon, and Goubau and Schwering, with early beam treatments; they summarize earlier work rather than claim the whole construction as a new discovery. Their paper brings beam propagation, focusing and finite-aperture diffraction into a common practical account. [ref]
https://dielslab.unm.edu/sites/default/files/Kogelnik66_0.pdf. Kogelnik and Li, 1966, introduction and §3
.For diffusion with a constant diffusion coefficient and no sources, the model flux is . A continuity equation gives . This proportionality is a constitutive assumption about transport; the continuity equation expresses conservation. If varies with position, it must remain inside the divergence, giving instead.[ref]
An exact constructed heat equation example on the whole plane uses dimensionless coordinates with and the smooth initial Gaussian function . Set . For ,Direct differentiation verifies both the initial condition andThe center decreases, while the region increases at that instant. The sign-change circle expands with radius . A fixed outer location can initially increase and later decrease as this circle passes it.
At time , the peak is , and the radius where the profile is times its peak is . The width grows as the height falls. Integration in polar coordinates givesThus a decreasing peak is compatible with a conserved spatial integral. Dividing by makes a probability density function with coordinate variances , connecting the same spreading to Brownian motion with diffusion coefficient one. Equivalently the profile is evolved by the Gaussian heat kernel with time parameter , since that article uses generator .
Gaussian dyadic summation bound Created 2026-10-06 Updated 2026-10-14
For fixed , and , complete the square in the exponent. A translated Gaussian function summed on a fixed-spaced lattice has mass uniformly in the translate, by comparison with its integral and its maximum. This keeps a square-root logarithm, rather than the full number of dyadic intervals, when summing exponentially damped exponential sum bounds.
Gaussian envelope in a Klein-Gordon medium 2026-10-14
For the stipulated Klein-Gordon packet velocities, take the original normalized spectral amplitudewith and . Here is the width of the spectral amplitude, not the standard deviation of its squared magnitude. Initially , a Gaussian function multiplying a carrier wave. Taking gives a real solution of the Klein-Gordon equation with the corresponding initial velocity. The tiny negative- tail is retained in this exact integral; the statement that it is mainly right-going is a narrow-spectrum approximation, not a claim of strictly positive wavenumbers.
Original Klein-Gordon packet evolution: exact spectral integral, slower envelope and carrier phase reference
. Details. The dimensionless figure uses and at . Blue curves are , orange bounds are , and the marked carrier wave reference is ; it need not be a crest of the full wavefield. The dashed envelope-centre reference is a leading approximation. These are calculated curves, not experimental records. The exact dispersion relation makes the packet slightly asymmetric; a quadratic approximation predicts symmetric broadening about .
The first-order Taylor expansion translates the initial wave envelope without changing its shape. Retaining curvature instead givesThe distinction between translation and curvature-driven spreading is the same one exposed by the Gaussian pulse calculation in Pulse Propagation by Richard Fitzpatrick (equations 9.8–9.18). Its first-order approximation is not an assertion that a dispersive packet keeps its shape indefinitely.
Evaluating the quadratic Gaussian integral gives the original approximationand henceHere is the amplitude width: the standard deviation of the normalized intensity is . The peak falls as the packet widens, while stays constant. This conserved integral is not the complete physical wave energy of the Klein-Gordon equation.
Rigid translation requires . The quadratic approximation can allow that quantity to be order one, but still requires the accumulated neglected cubic wave phase to be small over the appreciable spectrum, for example . This sufficient check controls only the stated three-width spectral window; the Gaussian tails must also be negligible at the required accuracy. Higher derivatives or very long times require returning to the exact spectral integral. The width is therefore a controlled local approximation; it neither predicts front velocity nor establishes a universal identity between group velocity and information velocity.
Gaussian hot spot under diffusion Created 2026-10-25 Updated 2026-10-31
On , the heat equation with initial Gaussian function , , has the displayed solution. Convolving the initial profile with the heat kernel adds the Gaussian width parameters; conservation of its spatial integral fixes the prefactor. Direct differentiation provides another proof. The width increases while the peak decreases, with no loss of the total integral.
Gaussian integral Created 2026-09-24 Updated 2026-10-20
The Gaussian integral gives the exact area under a Gaussian function. For a positive real number ,This is a finite improper integral over the whole real line. For example, and . Increasing from one to four narrows the curve and halves its area, while its height at zero stays one. The change of variables explains the factor .
The useful consequence is an exact normalization. For and any real center ,This is a probability density function for a normal distribution with expected value and variance . A narrower probability density function must be taller to keep total probability one. In the usual notation , the prefactor is , where is the standard deviation.
The same area calculation makes the one-dimensional heat kernelintegrate to one in , with the diffusion coefficient. A spreading Gaussian function can therefore preserve total mass while its height falls. This links the Gaussian integral with both the normal distribution and the diffusion equation.
Finite intervals lead to the error function, rather than this single constant:The complementary tail is described by the complementary error function. These definitions and their real-axis limits are given in the NIST reference. [ref]
Gaussian Poisson summation identity 2026-10-14
Take the Gaussian function with . Every derivative is a polynomial times the same Gaussian function, so is a Schwartz function. The Fourier transform of a Gaussian gives, in the cycles convention,Thus the Poisson summation formula gives the exact identityThe Gaussian Fourier transform is given in scaled form in Exercise 41 of Terence Tao's 245C, Notes 2: The Fourier transform.[ref]
245C, Notes 2: The Fourier transform by Terence Tao. §3, Exercise 41: transform of a scaled Gaussian; put r=1/sqrt(a) and adjust its prefactor
The identity is also the imaginary-axis transformation of the Jacobi theta function. At the Gaussian function is its own Fourier transform; at reciprocal values of its spatial and spectral widths exchange.For a short derivation of the Gaussian Fourier transform, write . Differentiation under the integral and integration by parts, using , giveThe Gaussian integral gives , so this ordinary differential equation yields the claimed formula. The decay of the Gaussian function justifies these steps and removes the boundary term.[ref]
Lecture 17: The functional equation. Lecture 17, §17.1, Lemma 17.9 and proof, printed p. 3: differential-equation proof for the unit Gaussian; scaled here to a>0
For , the physical Gaussian function has width parameter , while its Fourier transform has width parameter . Many physical samples matter, but the dual zero sample already givesFor , use the physical side instead:These are bounds on the full positive tails, obtained below, rather than estimates based only on the first omitted term. Ordinary floating-point arithmetic rounds these sums to and ; the exact real numbers are slightly larger. A Gaussian sum truncation bound lets us choose the cheaper side and certify its truncation error before evaluating it.
Gaussian pulse time-gate energy fraction 2026-11-05
The Gaussian pulse time-gate energy fraction is the share of an isolated pulse's laser pulse energy admitted by a finite time window. The result below acts on incident optical radiant power. Let be the power full width at half maximum, and first place the pulse centre and the detection time gate centre at zero.
A detection time gate need not collect the whole pulse. Integrating the same profile only over gives the Gaussian pulse time-gate energy fractionwhere is the error function. A gate as wide as the power full width at half maximum collects only , or 76.10% of the pulse energy. The pulse has nonzero Gaussian tails outside that interval. A real readout's impulse response can extend the required integration window further.
Alignment adds a parameter. Let the pulse centre be , the gate centre be , and write the Gaussian gate centring error as . Put . Integrating the normalized Gaussian pulse profile over the gate givesAt the two error function terms reduce to the centred formula above. With and , the captured fraction drops to . The pulse centre then lies on a gate edge. Merely keeping the gate width fixed does not keep its collected energy fixed.
The gate works best when centred. With the centred energy-normalized pulse profile and , differentiation of givesA Gaussian function is an even function about its centre and decreases with distance from that centre. Thus for , and symmetry gives the opposite sign for . The same argument proves that a centred interval maximizes mass for an even unimodal density; unimodality supplies the required monotonicity.
A centred gate of width captures of the energy. Solving gives for 99% capture in this ideal model. The requirement changes if the centring error is nonzero.
Pulse timing jitter can therefore create variation in gated energy even when every full pulse has the same . A wider gate reduces this loss but also changes admitted background and the chance of including neighbouring pulses. Measure the timing and detector response associated with the chosen gate.
For a detector modeled as a linear time-invariant system, its recorded waveform is a convolution of the optical input with its impulse response. NIST tested avalanche photodiode radiometers with roughly optical pulses, recorded their responses with an oscilloscope, and convolved measured responses with longer Gaussian inputs to estimate corrections. The detector and amplifier were characterized together.[ref]
Calibration Service for Low-level Pulsed-Laser Radiometers at 1.06 µm: Pulse Energy and Peak Power by Rodney W. Leonhardt. §§6.1–6.2, printed pp. 13–15: short-pulse excitation, sampling readout and numerical convolution
A gate applied to that electrical waveform must use the readout model rather than assuming the optical fraction is unchanged.