Chromatic aberration Created 2026-10-05 Updated 2026-10-14
An optical camera can focus a white object sharply in one colour while leaving coloured fringes around its edges in another. Chromatic aberration is the dependence of image position or image scale on wavelength, caused by optical dispersion in the optical lens materials. Axial chromatic aberration separates the optical foci along the optical axis; lateral chromatic aberration changes the transverse magnification with wavelength. Moving the receiving plane can favour one colour without bringing all colours into focus. [ref]; [ref].
For ordinary optical glass in the visible range, the blue refractive index exceeds the red refractive index. For a fixed positive thin lens in air, the lensmaker's equation then gives
Here is wavelength, is refractive index, is optical power, is focal length, and are the signed surface radius of curvature values in the lensmaker's equation. The blue light rays therefore bend more strongly and meet sooner. This ordering is a statement about ordinary visible optical dispersion, not a universal rule for every material and every spectral range. [ref].
For a worked example, take a single positive thin lens with reference optical power and Abbe number , hence reference focal length . Its F–C optical power difference is , by the achromatic doublet power balance relation below. This difference alone does not locate the reference optical power within the F–C interval. To draw a transparent example, introduce a synthetic colour coordinate , a dimensionless quantity, with red , reference , and blue , and choose the toy optical dispersion model
The diagram's red and blue endpoints represent the C and F endpoints of this toy model. Its reference point is placed symmetrically in optical power by construction; is not a measured wavelength scale, and the model is not measured optical glass data. The endpoint focal lengths are
Thus the axial chromatic aberration in this example separates the endpoint optical foci by about . A single receiving plane cannot coincide with both optical foci.
Figure 1.
Chromatic aberration: the blue optical focus precedes the red optical focus in a toy single thin lens
. Parallel incoming light rays meet an ideal positive thin lens at . The right panel enlarges the neighbourhood of the three optical foci; the reference focal length is . The synthetic model uses , , and . This is toy optical dispersion, not measured optical glass; the vertical scales are enlarged. Details.
The useful design idea is to cancel changes of optical power while retaining a positive total optical power. An achromatic lens does this with materials having different Abbe numbers. It greatly reduces chromatic aberration, but correcting two chosen wavelengths still leaves the possibility of a secondary spectrum.
Circular birefringence 2026-10-18
Circular birefringence means different refractive indices for opposite circular polarizations. In a transparent isotropic medium, their relative wave phase changes rotate the direction of transmitted linear polarization; optical activity gives the solution measurement and convention.
William Weber Coblentz's primary report describes an electrically heated porcelain cavity wound with platinum ribbon. Mirrors imaged its central radiating diaphragm onto a optical slit; a fluorite optical prism dispersed the beam onto a vacuum bolometer. Galvanometer deflections read the detector response. A resistance standard checked electrical sensitivity, while repeated readings checked stability. Sodium lines fixed the angular zero; a refractive index curve supplied wavelengths and slit-bandwidth corrections. Thermocouples were standardized at freezing points of zinc, antimony and copper. Drying the optical path reduced atmospheric absorption; prism scattering and temperature calibration remained limitations. These were Coblentz's measurements. His extraction of radiation constants assumed the Planck law, so it was not a model-independent proof of the spectral formula.[ref]
The inference to test is whether corrected spectra taken at independently determined temperatures have their maxima at a constant product . Comparing raw galvanometer deflections at different optical prism settings would also compare different wavelength widths and optical losses. The response integral in blackbody peak and detector response explains why those corrections belong to the physical inference rather than merely to presentation.
Take a cold, unmagnetized, collisionless plasma with uniform equilibrium electron density , fixed neutralizing ions, and a small electromagnetic wave that is a transverse wave. Cold means that thermal-motion corrections are neglected. For electron mass , elementary charge magnitude and electric field , the linear Newton's second law equation is . Thus and the current density is . Writing the induced electric polarization as gives a negative electric susceptibility. With vacuum permittivity ,
The plasma frequency controls the response. For , the propagating branch has real refractive index . For , this homogeneous model has an evanescent wave, not an ordinary propagating wave with a negative real refractive index. In a slowly varying vertical profile, a normally incident ray approaches a turning region where ; the geometrical-ray approximation fails right at that region. At oblique incidence the conserved horizontal wave vector changes the turning condition. A smooth density gradient can therefore return a skywave without a mirror or a layer of metal.
For a homogeneous propagating section, direct differentiation of the dispersion relation gives
A phase velocity greater than does not send information faster than . Here a narrow wave packet has group velocity , while the full causal response must still respect special relativity. Even this stripped-down plasma is strongly dispersive near its plasma frequency. In the actual ionosphere, collisions produce absorption, and the magnetic field of Earth changes the response with direction and wave polarization; a single real scalar cannot capture all of that behavior.
Conservation of etendue 2026-10-14
Lossless reversible propagation preserves the etendue of the same bundle of light rays. Here the model uses stationary isotropic media, specular reflection and refraction, with every selected light ray reaching the output and with no optical gain or scattering of light. An aperture that blocks some incident light rays changes which bundle is counted; the full incident and transmitted etendue need not be equal. [ref]
The underlying phase space has four coordinates. In a planar section with constant refractive index, let locate a light ray and set
The Jacobian determinant from spherical coordinates gives
Thus etendue is a four-dimensional volume, preserved by the optical counterpart of Liouville theorem in Hamiltonian mechanics. Individual position and direction extents may change, and correlations between them matter. The Lagrange optical invariant is a related paraxial approximation invariant for pairs of light rays, rather than the full four-dimensional measure.
For a positive refractive index depending only on , Fermat principle applied to has as a cyclic coordinate. The Euler-Lagrange equation therefore makes the displayed quantity constant along a stationary ray. When , its slope is . If is the angle to the axis, this is conservation of , the stratified-medium form of Snell's law. For fixed endpoint values, the integrand has second derivative with respect to . Its strict convexity and the constant momentum show, by the tangent-line inequality and integration, that any such ray is the unique minimum among competing graph paths with the same endpoints.
Critical angle for total internal reflection Created 2026-09-29 Updated 2026-10-18
For refractive indices , the critical angle for total internal reflection satisfies . Above it, the transmitted normal wavenumber is imaginary and the transmitted field is an evanescent wave.
The critical angle for total internal reflection is the boundary between outgoing refraction and an evanescent wave, rather than an angle at which the external electric field abruptly disappears. Write and . At the threshold, Snell law for electromagnetic waves has , hence
Here inverse sine selects . For and , and . The threshold is independent of polarization of an electromagnetic wave under the stated assumptions.
A short proof using phase matching at a planar wave interface reveals all three cases at once. Choose a Cartesian coordinate system with boundary , incident medium , and transmitted medium . With vacuum wavenumber , the shared tangential wavevector component is . The dispersion relation in medium two gives
Below , choose the positive real square root for an outgoing plane electromagnetic wave. At , : there is a grazing wave, with zero normal average power but no exponential confinement in . Above , choose with , so the wave amplitude decays into the second half-space.
If , no nongrazing angle of incidence produces this threshold. As from below, ; as that ratio tends to zero, . These limits explain why a larger refractive index contrast permits confinement over a wider range of internal angles.
Diffraction-limited resolution Created 2026-10-05 Updated 2026-10-14
Diffraction-limited resolution is a scale for distinguishing details with a specified ideal diffraction response and a specified criterion. For two equally bright, mutually incoherent optical point sources imaged through a uniformly transmitting, unobscured circular optical pupil, the Rayleigh criterion places the centre of one Airy disk at the first zero of the other. At small angles in air this separation is
Here is pupil diameter, is wavelength in air, and is the first positive zero of the order-one Bessel function of the first kind. This is the radius to the first zero, not the diameter of the central spot. Fraunhofer diffraction gives the radial peak-normalized light intensity
The removable value at zero follows from . The pupil Fourier transform reduces to a radial integral by circular symmetry, which produces the Bessel function of the first kind; its first zero supplies the factor .[ref]
In the usual scalar circular-pupil approximation for a fluorescence microscope, the corresponding object-plane Rayleigh criterion is
Here is the vacuum emission wavelength, and the object-side numerical aperture already includes the medium's refractive index. Do not divide by again. For small cone angles in air, and image-plane radius agrees with this form. The assumptions include a single wavelength, ideal optical focus, and mutually incoherent emitters. High numerical aperture can require a vector description with polarization of an electromagnetic wave and emitter orientation; confocal microscopy has its own excitation-and-detection response. The same formula therefore does not describe every microscope or illumination method.[ref]
Figure 1.
Doubling numerical aperture halves the ideal circular-pupil point-response scale at fixed wavelength
. Details.
In this original model, and numerical apertures and give first-zero radii and . Each point spread function is divided by its own peak to compare shape. The pupil axes are transverse wave vector components multiplied by , so pupil radius equals numerical aperture. A wider pupil accepts a wider range of transverse wave vectors, producing a narrower image. Increasing magnification alone enlarges the same spot and does not reduce its object-plane radius.
The Rayleigh criterion is a useful visual convention, not an absolute information barrier. For equal incoherent sources with total detected radiant flux and separation vector , the ideal image is
Below the Rayleigh criterion this still differs from ; for small , symmetry cancels the linear change and the first change is quadratic in separation. Estimating two unknown source positions is then increasingly sensitive to noise, background, relative brightness and uncertainty in the point spread function. Localizing one isolated source and recovering an arbitrary extended object are different inference tasks. Measurements that separate optical modes can also extract separation information differently from direct image light intensity measurement.[ref]
There remains a real limit for arbitrary images in this model: the optical transfer function is zero above the transmitted spatial frequency band. Its cutoff for scalar incoherent imaging is in object-plane cycles per unit length. The Nyquist–Shannon sampling theorem therefore suggests object-referred detector pixel pitch , with finer sampling providing margin. Finite detector pixels also integrate over their area, suppressing contrast; coarse sampling can cause aliasing. Finer sampling cannot alone recover spatial frequencies removed by the optics, and Fourier deconvolution amplifies noise where the optical transfer function is small. Photon shot noise, read noise, optical aberrations and defocus can all worsen practical discrimination. A useful resolution claim therefore reports the object model, criterion, wavelength, numerical aperture, sampling and signal-to-noise ratio in photon counting.
Dispersion (optics) 2026-10-05
Optical dispersion is the dependence of refractive index or phase velocity on frequency. It gives an optical prism wavelength-dependent deviation and causes chromatic aberration.
Double heterostructure laser Created 2026-10-18 Updated 2026-10-20
A double heterostructure laser electrically pumps its central layer for stimulated emission. Band offsets confine charge carriers; refractive index contrast confines the optical normal mode.[ref]
Figure 1.
Chosen type-I band alignment: carrier injection and optical readout
. Original schematic using stipulated energy units. The upper panel plots electron energy band edges across the layers; the lower panel separates electrical pumping from the emerging light. Flat segments omit band bending. The curves do not reproduce a historical device. Source. Details.
For an original bookkeeping model, let be the injected pair rate per unit area, the active-layer thickness, its excess pair number density, a recombination lifetime, and an escape time. Before appreciable stimulated emission, suppose
Choose two otherwise identical devices with and . The resulting steady state populations are and : improved confinement raises the population by a factor at fixed injection. This linear model assumes equal excess electron and electron hole densities, fixed lifetimes, and no laser gain clamping.
Optical confinement enters separately. For a chosen optical normal mode, define as its gain-overlap factor with the active layer. With material optical gain , internal loss , and mirror loss , a simple laser threshold condition is
For stipulated losses in inverse-length units, requires , whereas requires . This calculation varies optical overlap only; the preceding population calculation varies carrier escape only. Their combination explains the usefulness of controlling both the energy band profile and the optical normal mode.
Herbert Kroemer proposed the double heterostructure laser in 1963; he did not participate in its 1970 experimental realization.[ref] Zhores I. Alferov describes his group's independent 1963 proposal and later experimental program.[ref]
Electromagnetic waveguide Created 2026-10-14 Updated 2026-10-18
An electromagnetic waveguide confines an electromagnetic wave across its axis while allowing it to travel along the axis. Conducting walls or changes of refractive index select transverse normal modes: reproducible cross-sectional field patterns with their own longitudinal wavenumbers. A hollow metal pipe and an optical fiber are different realizations of this principle. Their usefulness is to deliver electromagnetic energy along a chosen route instead of letting it spread freely.
For a uniform vacuum-filled conducting guide, write a normal mode's axial and time dependence as . Here is angular frequency, is the longitudinal wavenumber, and is the transverse eigenvalue selected by the wall boundary conditions. The electromagnetic wave equation separates into
The geometry consumes part of the available squared wavenumber: when , this branch is an evanescent wave rather than a propagating normal mode. The waveguide cutoff frequency is therefore a property of a specified branch and geometry. A transverse electromagnetic mode in a suitable two-conductor geometry can have and no positive geometric cutoff. An optical fiber needs its own dielectric boundary conditions, rather than the metal-wall formulas below.
The rectangular electromagnetic waveguide makes these ideas explicit with a single sine profile. The scalar-potential conducting waveguide modes give a broader construction. At an open aperture, a confined field can radiate into the electromagnetic aperture angular spectrum; it need not remain one guided normal mode.
Empty magnification 2026-10-14
Empty magnification enlarges an image without revealing additional specimen detail. Adequate angular magnification can make existing detail visible to the eye, but it cannot undo the objective's diffraction blur. For equally bright, mutually incoherent optical point sources and an ideal circular optical pupil, a commonly used lateral Rayleigh criterion in object space is
where is the vacuum wavelength, is the specimen-medium refractive index, and is the admitted half-angle. For this model, and give ; changing only numerical aperture to gives . Changing only the eyepiece leaves this object-space scale unchanged. Illumination, optical coherence, optical aberrations and specimen visibility matter in real instruments; this criterion is not a universal threshold.[ref]
The geometric reason is especially simple. If a fixed recorded image is enlarged by a factor , a feature separation and a blur width become and . Their ratio remains
This is the lower-panel construction in the diagram. A change to the microscope objective can change numerical aperture and hence the specimen detail captured; a display zoom changes how large that captured detail looks. Microscope scale calibration, diffraction-limited resolution and angular magnification are three complementary properties to report.
Etendue Created 2026-10-06 Updated 2026-10-14
Etendue measures how much position-and-direction space a bundle of light rays occupies. A small spot accepting a wide range of directions can have the same etendue as a large spot accepting a narrow range. This makes etendue useful for deciding whether an optical instrument can deliver an extended source's entire admitted radiant flux to a small receiver. For forward crossings of a surface, the geometrical optics definition is
where is the occupied set of surface positions and directions, is the local refractive index, is actual surface area, is solid angle, and is the angle to the forward unit normal. The cosine supplies the projected area. Opposite crossing directions must be counted separately with positive projected area, rather than cancelling them in a signed integral. [ref]
The shorthand assumes constant refractive index, a narrow nearly normal bundle, and the same admitted directions across the whole area . At larger angles, use the cosine-weighted integral; a position-dependent angular acceptance cannot generally be replaced by the product of two independent extents.
Suppose an extended source fills every position of the entrance aperture with a cone of half-angle , and all these light rays must reach a one-sided planar receiver. If the receiver accepts at most a cone of half-angle , its available etendue bounds the admitted etendue:
Consequently
This original derivation combines conservation of etendue with the exact cone integral; the second inequality allows the complete output hemisphere. It bounds capacity and does not prove that a chosen shape attains the bound.
Figure 1.
Aperture clipping discards etendue; full-flux concentration requires a larger output angular range
. Left: a stop transmits of the spatial disk with unchanged directional acceptance. Right: endpoint geometry for the ideal air-to-air input-cone bound, . Interior sides are only a symbolic connection between ports, not a designed reflector or a traced ray path. Details.
For the input cone with , : a entrance cannot deliver the entire filled bundle to a circular receiver smaller than in diameter. If the output half-angle is restricted to , and the receiver diameter must be at least . For a receiver medium with model refractive index , the full-hemisphere capacity bound instead gives ; that larger value also depends on transmitting the bundle into that medium.
Attempting in the air-to-air example forces rejection of some input. For the uniform radiance already specified, even filling the entire output hemisphere gives
The maximum mean irradiance gain remains . With nonuniform radiance, rejecting a given fraction of geometric etendue need not reject the same fraction of radiant flux.
These bounds use a filled extended-source bundle in passive reversible geometrical optics, comparing the same wavelength and the same radiation channels. An ideal optical point source does not fill that four-dimensional set. Diffraction, optical coherence, or coupling a Gaussian beam into an optical fiber require a physical optics calculation; the cone bound is not a universal guarantee for a single wave mode. Likewise, optical gain or fluorescence changes the propagation assumptions.
Consider a planar circular aperture of diameter in constant refractive index . Suppose every position in its area is filled with directions inside the same rotationally symmetric cone about the unit normal, with half-angle . Using spherical coordinates, the exact etendue is
where is the appropriate side's numerical aperture. The ordinary cone solid angle is ; its cosine-weighted value is . A full forward hemisphere therefore gives , rather than . [ref]
For an original model example, choose , , and . Then
If the radiance is uniform across this filled bundle and equals , its radiant flux is . Neither the geometry nor the chosen radiance is an experimental measurement.
Define the amplitude evanescent penetration depth as the distance at which the electric field wave amplitude falls to of its surface value:
The squared-field envelope decays twice as fast:
The same normalized exponential decay describes the tangential average Poynting vector for the TE polarization above. An intensity penetration depth convention often means ; it must not be confused with amplitude depth or interpreted as outgoing normal light intensity.
For the stipulated , , and ,
At the normalized wave amplitude is approximately , and its squared envelope is approximately . At , these become and , respectively. The quantity inside the square root is dimensionless, so has inverse-length units and both depths have length units.
Figure 1.
Constructed evanescent-field model at 633 nm: amplitude and squared-field decay at 50 degrees, and their penetration depths as incidence increases above the critical angle
. Details.
The sharp angular dependence has a simple explanation. For with small and measured in radians, a first-order Taylor expansion gives
Thus as : exponential confinement disappears continuously. With fixed refractive indices, decreases as the angle of incidence increases and approaches as . This is a limit of the normalized depth; exactly grazing incidence supplies zero incident normal power. Real beam widths, angular spreads and optical dispersion matter when applying these ideal plane electromagnetic wave predictions near the threshold.
Extraordinary wave 2026-10-14
The extraordinary wave's electric displacement field lies in that plane and is perpendicular to the wavevector; its electric field need not be. For angle between the wavevector and optic axis,
Thus and .[ref]
A short derivation starts from the existing plane wave in an anisotropic dielectric equation. Put and , with angular frequency and vacuum speed of light . The component gives the ordinary wave relation . The determinant of the system gives
Substituting and yields the displayed directional refractive index.
Fabry–Pérot transmission from multiple reflections Created 2026-10-14 Updated 2026-10-20
Consider two identical, lossless parallel mirrors with intensity reflectivity , separation , and a uniform transparent medium of refractive index . Fix one polarization of an electromagnetic wave and an internal angle of incidence measured from the mirror normal vector. Illuminate with a monochromatic wave having planar wavefronts; the emerging contributions must overlap coherently in the detected direction. Define using the same incident and exit media. Each mirror transmits a fraction of incident power. Its reflected wave amplitude has magnitude , so two internal specular reflections multiply the circulating complex amplitude by magnitude , not .
Let be the vacuum wavelength and choose the reflection wave phase convention in which the product of the two internal amplitude reflection coefficients is real and positive. The phase difference between successive transmitted contributions, evaluated on a common outgoing wavefront, is
With other mirror coatings or phase conventions, use the total , where is the sum of the two internal reflection wave phases. The stated resonance positions presume modulo ; a constant nonzero shifts them, while a frequency-dependent one can also change their spacing.
Why does the cosine appear rather than its reciprocal? Inside the gap, the extra two legs have optical path length . But the later emerging contribution starts farther along the mirror. Comparing both on one outgoing wavefront subtracts from that path difference, leaving . Equivalently, a plane wave's mirror-normal wavevector component is , so the round-trip wave phase is . The diagram uses the same medium outside and inside to show the common-wavefront subtraction directly; at a refracting exit interface, tangential wavevector matching in Snell's law supplies the same result.
Figure 1.
Multiple specular reflections become a coherent sum of transmitted complex amplitudes
. Original ideal geometry and amplitude construction, not apparatus data. The oblique rays expose successive round trips and the common outgoing wavefront; is internal. The amplitude panels independently use at and . Only the first five terms are drawn, with the infinite-sum endpoints marked. At normal incidence the outgoing contributions overlap directly. Details.
Absorb the common first-pass wave phase into the incident complex amplitude . Successive transmitted contributions are , , and so on. The superposition principle and the convergent geometric series give
The last step expands the squared complex modulus as . This transmission profile is often called the Airy transmission function; it is distinct from the Airy disk, a diffraction image of a circular aperture. The University of Washington's lab handout gives the same transmission profile and distinguishes mirror reflectivity from other sources of peak broadening.[ref]
For an original example, set . At , the amplitudes add to , so . At , they alternate in sign and add to , so . At , the amplitude is and . Adding the individual intensities instead would give , independent of wave phase; that discards the wave interference responsible for the peaks.
In general the maximum is at , with integer , and the minimum is halfway between peaks. Perfect resonant transmission requires identical lossless mirrors, coherent illumination, and sufficient time to establish the steady field. Absorption, unequal mirror transmission, finite beams that fail to overlap, and fluctuations of can reduce it. The exactly reflecting case is excluded: no incident power enters through a perfectly reflecting mirror, and the resonant limit is singular.
Faraday effect Created 2026-10-14 Updated 2026-10-20
The Faraday effect is magnetic field-induced circular birefringence: opposite circular polarizations acquire different wave phases, rotating transmitted linear polarization. For a transparent medium with isotropy before applying the magnetic field, in the linear magnetic-response regime at fixed vacuum wavelength and temperature ,
Here is the Verdet constant, is the material path length, and is the applied magnetic flux density component along the ray. This is the external bias, distinct from the oscillating magnetic field of the light itself. Michael Faraday discovered the effect in 1845.[ref]
Fix the sign before using the formula. On the forward path choose a right-handed Cartesian coordinate system, propagation along , and measure from toward for the electric field's oscillation line. Positive is counterclockwise in the -right, -up end view seen from , looking toward the source. Then and positive means positive rotation for positive . This convention differs from the clockwise-positive convention in optical rotation. A linear polarization line is unchanged by ; a measured orientation determines accumulated rotation only modulo , unless continuity selects a branch.
For uniform , the formula reduces to . Its appeal is that a weak change of refractive index becomes a visible change of orientation. Magnetic reversal measurement of Faraday rotation turns this into an inference of or of the magnetic field path integral. Faraday rotation on a round trip explains the directional behavior used by an optical isolator. In an astronomical cold plasma, the high-frequency limit instead leads to the rotation measure law ; that wavelength dependence is not a universal law for transparent solids.
The factor of one half follows from superposition, without assigning ambiguous right/left names to the circular polarizations. Use the complex amplitude convention and fixed transverse unit vectors
For equal transmitted wave amplitudes, let the accumulated wave phases be and . Their sum is
The common wave phase sets the timing of the electric field oscillation; the real direction in parentheses sets its linear polarization. Opposite circular polarizations have changed their relative wave phase, yet their sum still oscillates along a line. Unequal transmitted wave amplitudes would generally give elliptical polarization instead.
In a uniform sample, with refractive indices and vacuum wavenumber , the phase difference is . Thus
The second relation identifies the small signed circular birefringence responsible for the rotation in this basis. Unlike a waveplate, whose separated modes have orthogonal linear polarizations, this ideal rotator has modes with opposite circular polarizations.
Figure 1.
Equal opposite circular polarizations acquire a relative wave phase and give Faraday rotation
. Original normalized model: common wave phase is removed, and the relative wave phase grows linearly with path fraction. The top panels add the real circular-component electric field vectors at the same time. Orange lines mark the resulting linear polarization direction. The lower panel compares relative wave phase with its half-angle rotation. No material measurements are plotted. Details.