Periodic function Created 2026-09-24 Updated 2026-10-14
A periodic function repeats exactly after a nonzero shift of its input. For , a positive period of a function satisfies
One interval of length therefore determines the whole function. For another domain of a function , a period must also preserve the domain, ; equality only where two domains happen to overlap is weaker. Periodicity is an exact translation of a function symmetry, rather than merely two similar-looking pieces of its graph.
The sine has fundamental period one. The function repeats after half a unit: the sine changes sign under that shift, but squaring removes the sign. The mixed function again has fundamental period one. All positive integer multiples of a period are periods, so specifying one period need not identify the shortest repetition.
Figure 1.
Mixed harmonics, a squared sine, and a constant have different sets of periods
. Details.
If the input is time and is the fundamental period, the frequency is and the angular frequency is . Repetition lets a Fourier series describe a cycle using sines and cosines; the period average separates the reference level from the oscillating terms. Strang develops this representation and its Fourier coefficients in §4.1 of Computational Science and Engineering by Gilbert Strang.[ref]
This connection grew out of a physical problem. In his 1822 book Théorie analytique de la chaleur by Joseph Fourier, Joseph Fourier used periodic functions to extend profiles beyond their initial interval while treating heat conduction. Chapter III, §§233–234 combines even functions and odd functions into sine–cosine expansions and rescales their period.[ref] A modern Fourier series interpretation still requires the appropriate convergence conditions.
A constant function has every real shift as a period and no fundamental period. Without continuity, even a nonconstant periodic function can lack a smallest positive period; periodic function without a least positive period gives a concrete example. The period group of a function organizes all these possibilities.
A shunt electrical resistance inserted between the conductors of a uniform lossless transmission line of characteristic impedance has voltage reflection coefficient and transmission amplitude . Equally spaced shunts produce coherent reflected waves. The round-trip phase between neighbours is , so interference repeats in frequency with spacing for nondispersive phase speed .
The two-layer cell seismic layer transfer matrix has reciprocal eigenvalues because its determinant is one. Writing them as gives the displayed half-trace relation. At a real frequency, an absolute half-trace exceeding one forces an exponentially growing/decaying pair instead of propagating cell modes. A long finite stack then suppresses transmission in this stop band, without dissipating energy: the missing transmitted flux is reflected. Quarter-wave layers of unequal seismic impedance give half-trace .
Periodization of a Schwartz function Created 2026-10-05 Updated 2026-10-14
For a Schwartz function on the real numbers, its periodization is a smooth periodic function of period of a function one. Rapid decay gives uniform convergence on of the defining series and each differentiated series. Its th Fourier coefficient is
The change of variable uses . Rapidly decreasing Fourier coefficients give the absolutely and uniformly convergent Fourier series . Evaluation at proves the Poisson summation formula.[ref]
The same identity explains aliasing in the Nyquist–Shannon sampling theorem: applying the Poisson summation formula to the Schwartz function gives
The sampled spectrum is periodic in frequency, and shifted copies of the continuous Fourier transform add together. When those copies overlap, the samples cannot separate their contributions. The Nyquist–Shannon sampling theorem adds a bandlimited function hypothesis to make reconstruction possible.
Permittivity Created 2026-10-05 Updated 2026-10-18
Permittivity describes how an electric field and a material's electric polarization combine into the electric displacement field. In a static, local response with linearity and isotropy, and no electric polarization at zero electric field, the constitutive equation is
Here is vacuum permittivity, while is the relative permittivity, a dimensionless quantity. The SI unit of permittivity is farad per metre, : multiplying it by an electric field in gives an electric displacement field in . A larger positive permittivity lets the same parallel-plate capacitor hold more plate electric charge at the same electric potential difference.
The material contribution is electric polarization , the electric dipole moment per unit volume. The electric displacement field and electric susceptibility satisfy
Substitution gives the first constitutive equation. The electric field here is the averaged, total field inside the material, not just the field of the external plate electric charges. The continuum approximation averages over many chemical atoms or molecules; locality means that the electric polarization at a position depends on the electric field there. Static equilibrium, fixed material conditions and sufficiently small electric fields are needed for this scalar proportionality. [ref].
For an ideal parallel-plate capacitor completely filled by a uniform dielectric, hold the free plate electric charge magnitude fixed and neglect the fringing field of a capacitor. Writing for the plate area, Gauss's law gives . Thus
The electric dipoles point along the electric field. Their surface electric charges, described by polarization density, oppose the field from the free plate electric charges. For a hypothetical dielectric with , the internal electric field is one quarter of its vacuum value, while . At fixed electric potential difference instead, the internal electric field stays approximately and the plate electric charge grows fourfold. These are different experimental constraints. [ref].
Figure 1. . An original schematic and normalized model comparison for a uniform dielectric with relative permittivity four. The arrows for electric dipole moments run from negative to positive electric charge; the two field contributions oppose each other. The bar values compare electric displacement field , , and electric polarization , which all have units . The schematic is not to microscopic scale. Details.
Permittivity is a useful material summary, not a universal constant of the material under every condition. Temperature, frequency and electric field strength can change the response. In a linear anisotropic dielectric, permittivity is a tensor, , so the electric displacement field need not be parallel to the electric field. At nonzero frequency, delayed electric polarization requires complex permittivity and may produce dielectric loss. [ref].
Permittivity tensor 2026-10-18
The permittivity tensor is the linear material-response matrix relating electric displacement field to electric field at a specified frequency. An isotropic local medium has . A magnetically biased transparent medium can have an imaginary antisymmetric transverse contribution; its eigenmodes can have opposite circular polarizations and different refractive indices.
Phase refractive index 2026-10-20
The ratio compares vacuum light speed with the phase velocity at a specified frequency. In a dispersive material it differs from the group index; the Cherenkov radiation cone uses the phase index.
Phase-sensitive detection 2026-10-20
phase-sensitive detection correlates an input with a synchronized reference and filters the product. Sinusoidal quadrature references recover both signal amplitude and relative phase. Narrow detection bandwidth rejects incoherent noise but cannot reject a background coherent at the same frequency; changing the integration time also changes settling and tracking speed.[ref]
Phase velocity Created 2026-09-24 Updated 2026-10-14
The phase velocity is the motion of a constant-wave phase surface. For a one-dimensional plane wave with real and real , fixing gives
Each wave crest of this monochromatic travelling wave advances at that signed phase velocity. Its magnitude is the phase speed , where is the wavelength and is the temporal period when . Choosing makes positive mean rightward phase velocity and negative mean leftward phase velocity. Reversing both signs leaves the real plane wave and its phase velocity unchanged. At there are no spatial crests to track, so is undefined; a finite limit as is a limiting phase speed, not the speed of a spatially uniform oscillation.
In several dimensions, a plane wave has wave phase . Constant-wave phase planes obey . Their normal phase velocity is
Tangential motion within a plane does not move that wavefront, which is why the normal direction fixes the vector convention. In an anisotropic medium the group velocity need not point along this wavevector. Likewise the horizontal phase velocity of a tilted wavefront is its crossing speed along a horizontal line, rather than a component of the normal phase velocity.
For the nondispersive wave branch , a wave crest and a wave envelope both move at . For deep-water surface gravity waves, gives and group velocity . With the illustrative choices and , the model predicts and . These are calculated values for negligible surface tension and sufficiently large , not measurements. A wave crest moves forward through the wave packet, so timing a crest does not time the packet's journey.
There is a direct laboratory meaning to this distinction. MIT's 2005 surface-wave lab uses a long water tank, a controllable hydraulic paddle, and an absorbing beach. Resistance probes convert submerged length into voltage; calibration converts their readouts into free surface elevation versus time. Two probes a known distance apart, backed by a ruler and stopwatch, let students time a wave crest and separately time a feature of the wave packet. The lab records depth and varies frequency and wave amplitude.[ref]
For a clean measurement of phase velocity, fit the periodic portion of both records or follow one identifiable wave crest. A phase difference is only known modulo : probe spacing below half the shortest relevant wavelength, or continuity while sweeping frequency, avoids assigning the wrong whole-cycle delay. Then compare the timed phase velocity with . Tracking pepper grains instead measures fluid-particle motion, which has a different meaning from either phase velocity or group velocity.
The Klein-Gordon packet velocities example makes the distinction especially sharp: its phase velocity exceeds , yet its narrow wave envelope moves below . A carrier wave labels successive oscillations; its speed alone does not establish information velocity. The front velocity depends on the full causal model, including angular frequencies far outside the carrier's narrow range.
Photodetachment threshold Created 2026-10-14 Updated 2026-10-20
In the published chlorine experiment, negative ions were accelerated and mass-selected, then overlapped with a tunable laser beam. A downstream electric field deflected charged ions; neutral chemical atoms continued to a plate, whose secondary electrons were counted. Scanning the laser frequency produced an onset in this neutral-atom signal. The apparatus therefore inferred an electron affinity from a threshold, rather than measuring the heat of attachment.[ref]
Reversing the laser direction and averaging the two thresholds corrected the first-order Doppler shift. A Fabry–Pérot interferometer and reference spectral lines calibrated the frequency. Finite laser bandwidth, unresolved quantum state splitting and shifts of the calibration lines limited the inference; the authors included these effects in fitting and the error estimate. The level diagram shows only the extracted gap, not a measured signal curve.[ref]
Thorlabs' silicon FDS100 experiment sends a collimated, fibre-coupled laser beam through a beam splitter to the photodiode and a reference optical power meter. Varying reverse bias and electrical load tests linearity. The measured readout approaches saturation when its electric potential difference consumes the bias.[ref] A separate low-signal setup uses a laser, polarizers, an optical chopper, optical attenuators and a lock-in amplifier inside a light-tight enclosure. These are actual apparatus choices, not the parameters of the constructed example above.[ref]
For an independent dark current check, Thorlabs enclosed a photodiode in nested metal boxes to exclude light and suppress interference, used a Keithley 6487 ammeter supplying reverse bias, and monitored temperature. Only one specimen per type was tested; the nearby temperature sensor did not directly contact the semiconductor. Such a dark control measures the baseline but cannot certify spectral responsivity.[ref]
To infer spectral responsivity at a selected wavelength, measure the radiant flux actually reaching the test photodiode, rather than just the reference arm. A reference-arm measurement calibration must include the beam splitter ratio and path losses. With signed readouts in one fixed orientation, subtract a beam-blocked baseline and use
for direct electric current readout or a calibrated linear transimpedance amplifier, respectively. Repeating at several incident powers tests whether this ratio is constant. Blocking only the source estimates ambient light plus electronic baseline; covering the detector excludes ambient light too. Their difference distinguishes optical background from dark current and readout offset. For a broad optical spectrum, the ratio is a spectrum-weighted response, not generally at one wavelength.
For independent Poisson distribution collection, the root mean square shot noise in a one-sided rectangular frequency band of signal bandwidth is
Here is reverse dark current; thermal electrical noise and amplifier noise also contribute.[ref]
Subtracting a mean dark current removes its offset, not its fluctuations: subtracting a constant leaves the variance unchanged. Consequently makes dark current shot noise small relative to signal shot noise; it does not by itself establish high signal-to-noise ratio. With an independently measured baseline, the variance of that estimate must also be propagated. Increasing the measurement signal bandwidth raises the admitted noise. Calibration of wavelength, reference radiant flux, readout gain and collection geometry, together with drift and linearity, determines what measurement uncertainty can be claimed.
Photoelectric contact-potential correction Created 2026-10-18 Updated 2026-10-20
Define as positive when the contact field adds to the retarding barrier, and let be the signed externally imposed retarding voltage. In this chosen sign convention the barrier is , hence
This convention specifies a model of the gap; an instrument's polarity labels must be translated into it. With a fixed , subtraction at two frequencies removes both the work function and the offset:
For an original example with the same and an additional , choose and . The predicted terminal endpoints are and . The negative first endpoint calls for a small externally accelerating voltage because the contact field already over-retards the fastest electrons. Their difference is , giving . Ignoring in the intercept would falsely infer for the work function. The terminal line's zero would then be mistaken for a material threshold. If drifts between the two readings, even the slope is biased. These are calculated examples, not Millikan's measurements.
Photoelectric effect Created 2026-10-18 Updated 2026-10-20
The photoelectric effect is the release of electrons from matter following photon absorption. Here the focus is emission from a metal surface into vacuum: a photon supplies energy, the work function pays the escape cost, and the remainder can become the emitted electron's kinetic energy. A photocurrent counts collected electric charge; a stopping potential probes the upper kinetic energy limit. These are different measurements.
In 1905, Albert Einstein proposed that an individual light quantum could transfer its whole energy to one electron. His §8 allowed losses before escape, distinguished the fastest emitted electrons from the rest, and predicted a straight stopping potential versus frequency relation with a material-independent slope. He separately predicted that changing light intensity changes the number emitted without changing their velocity distribution under otherwise identical conditions. He also discussed incomplete transfer and limits to the account.[ref]
The useful modern starting model is a clean, homogeneous metal with independent single-photon events, negligible initial thermal broadening, negligible lowering of the surface barrier by an applied electric field, and negligible electric fields from the emitted electrons themselves. Specify the surface and its work function; it is not enough to name the bulk material. The Einstein photoelectric equation describes the upper edge of the emission energy distribution. It neither predicts that every absorbed photon liberates an electron nor supplies the whole photocurrent curve. Its appeal is that a complicated surface process still exposes the universal Planck constant through a simple slope.
Photoelectric saturation current Created 2026-10-18 Updated 2026-10-20
The photoelectric saturation current is the photocurrent reached when increasing the collecting electric potential difference no longer increases the fraction of available emitted electrons collected. It is saturation with collecting voltage at fixed illumination. It does not mean that increasing incident light intensity cannot increase emission.
If is incident radiant flux on the emitting area and is the external quantum efficiency for producing escaping electrons, then the incident photon arrival rate is and complete collection gives . For the example's , choose and . The calculated photon arrival rate is and . Doubling doubles this current to while leaving fixed. At fixed illuminated area this doubles the irradiance. Changing frequency at fixed changes the arrival rate as well as the photon energy; can also change, so there is no general rule that a higher frequency gives a larger photocurrent.
A missing plateau can indicate incomplete collection or an electric field altered by the emitted electric charge. Heating, surface changes and additional emission channels can invalidate a constant . Even a small amount of unwanted higher-frequency radiation can move an apparent endpoint. A stopping potential inferred from zero net current additionally needs background subtraction and a check for emission from the collector itself.
The photoelectric threshold frequency is the lower frequency boundary allowed by the ideal single-photon energy balance. With vacuum wavelength and speed of light , its corresponding longest wavelength is . The chosen work function gives and . These are model parameters, not a measured threshold for a named metal. Detectable photocurrent need not begin abruptly at the ideal boundary: collection, finite spectral width, thermal broadening and surface inhomogeneity matter.
Photoelectron binding energy reference Created 2026-10-18 Updated 2026-10-20
Let a conducting sample and conducting analyzer be in good electrical contact, unbiased, at equilibrium, and without appreciable charging during illumination. Their Fermi levels then coincide. Choose that common Fermi level as zero. Define as the binding energy relative to this zero: removing an electron into the electron reservoir at the Fermi level costs . It is not the cost of removing the electron all the way to the sample's vacuum level.
Write the sample and analyzer work functions as and . Their local vacuum levels lie at and above the common Fermi level. Conservation of energy for an electron emitted without additional losses gives total outgoing energy , where is the Planck constant and the photon frequency. Immediately outside the sample its kinetic energy is . The contact-related electric potential changes this to
Thus the sample work function cancels when the measured kinetic energy is referenced to the analyzer. Substituting for in the final conversion would mix two different energy references. An instrument's calibrated binding energy scale can incorporate its effective analyzer work function, so the correction need not appear as a separate operator-entered number.
As an original numerical example, stipulate , and a line at . The predicted analyzer kinetic energy is . If , the surface value is instead ; the contact-related increase is . A second line at gives at the analyzer. A chemical shift in photoelectron spectroscopy therefore appears as a shift in measured kinetic energy. These are chosen values, not a measured carbon spectrum.
Charging breaks the assumed reference. If a uniformly charging sample rises by electric potential relative to the analyzer, an escaping electron loses an additional energy , with the positive elementary charge. Applying the unbiased conversion consequently returns
Two features from the same stable potential retain their separation. Features from regions at different potentials acquire different offsets, which can mimic chemical differences or broaden a line. A conducting holder alone does not establish electrical contact through an insulating surface layer. Compare repeat scans, electrical contact and charge-compensation settings before interpreting an offset as a change in chemical bonds.
Measurement calibration is a separate issue: a known reference line tests the scale, while charge compensation controls the specimen's electric potential. In an original offset model , one known line determines . An unknown scale factor in requires two distinct known lines to determine both and . Re-reading a reference after a sample checks drift. Treating an unidentified contamination peak as a universally fixed reference would assume the chemical identity and electrical behavior that the measurement should test.
Photometry (optics) 2026-10-13
Photometry weights visible electromagnetic radiation by standardized visual response functions; radiometry measures its energy and power without visual weighting.[ref]
The question is how much light a source supplies under a stated visual weighting. A beam containing at the defining frequency has luminous flux . Moving the same radiant flux to a region of smaller spectral luminous efficacy reduces its luminous flux. Changing the optical spectrum changes this conversion even when its total power stays fixed. This makes photometry useful for comparing lighting, while radiometry remains necessary for an energy budget. The lumen counts luminous flux; the candela additionally specifies its distribution over solid angle.
Two measurement routes implement the weighting: measure an optical spectrum and evaluate a weighted integral, or use a photometer whose spectral responsivity approximates the prescribed weighting. Both require a specified collection geometry. Neither is a complete prediction of an individual's perception of a scene.[ref]
A monochromatic beam of frequency and mean radiated power carries mean photon rate . It follows by dividing energy per unit time by energy per photon. A broadband source instead requires integrating spectral power divided by the frequency-dependent photon energy; electrical input power must first be converted to radiated power.
Photon energy 2026-10-18
The energy carried by one photon is proportional to its frequency , with proportionality constant the Planck constant . The equivalent forms use angular frequency and vacuum wavelength . Different observers can measure different photon energies because they measure different frequencies; the photon remains massless. In signature , an observer with four-velocity measures , where is the photon's four-momentum and .
Photon gas 2026-10-13
A photon gas is a collection of photons described statistically as radiation. Here the equilibrium model is homogeneous, isotropic electromagnetic radiation in vacuum at temperature : each photon has energy , with momentum and frequency , and there are two independent transverse states of electromagnetic polarization. An absorbing cavity with walls at a common temperature provides a way to establish this thermal equilibrium. The bulk formulas assume cavity dimensions much larger than the typical wavelength , so the electromagnetic mode density in a box can replace individual cavity modes by a continuum. [ref]
The crucial constraint is whether photon emission and photon absorption, or other number-changing processes, can equilibrate the photon population. When they can, photon number is not an independently conserved quantity and the equilibrium photon chemical potential is . For each polarization and frequency, the mean occupation number then follows the Bose-Einstein distribution:
If number-changing processes are ineffective but number-conserving interactions redistribute energy, a constrained Bose-Einstein distribution can instead have with chemical potential fixed by the number constraint. Thus thermal equilibrium with respect to energy exchange alone does not establish . The zero value can also persist in an already prepared Planck photon distribution during suitable subsequent evolution; continual photon emission is not required to preserve it. [ref]
Combining with the two-polarization density of states, , gives the Planck photon distribution and the spectral photon energy density:
Here is the spectral radiance in Planck's law; is stored energy density per unit frequency, not outgoing power per area. Their different units are connected by the full-sphere solid angle and the speed of light . The Boltzmann constant is , and is the Planck constant. [ref]
The equilibrium equation of state is particularly simple:
The radiation constant is the same constant called in black-body radiation; is the Stefan-Boltzmann constant. An outline of the energy density calculation substitutes and uses . The radiation pressure follows because the angular average of the squared directional component of photon momentum is for isotropy; the thermodynamic derivation of blackbody radiation pressure supplies an independent route. These formulas describe the radiation contribution, not the cavity walls. The isotropic massless relation survives a different isotropic spectrum, whereas the coefficient in requires the zero-chemical potential Planck photon distribution.
For a computed example with stipulated , the photon energy density is and the radiation pressure is . The photon number density in the International System of Units is
Here is the Riemann zeta function. The mean photon energy differs from the energy at the peak of a spectral curve: counting photons and weighting them by energy emphasize different frequencies. The calculations use the exact International System of Units values of the Planck constant, Boltzmann constant and speed of light. [ref]
Figure 1.
Analytic photon gas spectra: counting photons and weighting their energies
. Original equilibrium model, not measured data. The left panel evaluates at stipulated per gigahertz. The right panel uses and plots the normalized spectral fractions and , each with total integral one on . Their different shapes show why a photon-counting spectrum and an energy density spectrum have different peaks. Details.
A motivating observation is the cosmic microwave background spectrum measured by the Far Infrared Absolute Spectrophotometer (FIRAS) aboard COBE. Its apparatus used a polarizing Michelson interferometer, with one input viewing a roughly seven-degree sky patch and the other an internal blackbody. Scanning mirrors changed the optical path length difference; heat-sensitive detectors recorded the varying power, and Fourier transform spectroscopy recovered the spectral difference. Operation outside the terrestrial atmosphere removed atmospheric emission and absorption, while shielding and cooling the optics in a helium cryostat suppressed the instrument's own radiation. [ref]
Absolute calibration came from moving an external blackbody into the sky aperture, filling the same beam used for the sky. This was an iron-loaded epoxy absorber shaped as a re-entrant cone. Repeated reflections made it a close approximation to a blackbody, while thermometers supplied its temperature. Mather and colleagues explicitly evaluated reflections, temperature gradients, radiation leaking through the material and leakage around its edge. These are limits on how faithfully the calibrator realizes thermal equilibrium radiation, rather than details that can be eliminated merely by calling it black. [ref]
During sky observations the internal blackbody temperature was adjusted to nearly null the spectral difference, reducing gain and drift errors. Fixsen and colleagues' 1996 analysis used calibrated spectra over wavenumbers to , about to . They separated the sky's spatially uniform component, its dipole and Galactic emission, and varied sky cuts and foreground templates as controls. The resulting cosmic microwave background spectrum agreed with a single Planck function, with reported RMS deviations below 50 parts per million of its peak brightness. This is a residual statistic over the analyzed spectrum, not a pointwise relative error bound at every frequency. [ref]
The observation motivates using a photon gas as a physical model rather than merely a formal counting exercise. Its interpretation has a clear boundary: agreement with Planck's law constrains departures from an equilibrium spectral shape within the calibrated band and foreground assumptions; it does not directly measure radiation pressure or entropy density of a photon gas. Nor does it establish that today's cosmic microwave background is continually re-equilibrating with matter. A previously thermal spectrum can retain its Planck function shape as expansion of the universe lowers every photon frequency in the same proportion. The usefulness of the model is that one measured spectral temperature, together with its equilibrium assumptions, predicts energy density, radiation pressure, photon number density and entropy density of a photon gas consistently.