Purdue's Bicycle Wheel Gyroscope demonstration uses a bicycle wheel on a long axle, with a ball at one end seated in a freely rotating socket on a heavy stand. Spin the wheel by hand or with the supplied motor, seat the ball, and release the nearly horizontal axle. The readout is the axle sweeping around the vertical while the wheel continues spinning. Compare with the stopped wheel, which falls when one end is released; reverse the spin with the same support and the precession reverses. These are the page's documented apparatus, presentation, and reversal checks. [ref]
An alternative in Physics Demonstrations by Julien Clinton Sprott (section 1.3, Materials and Procedure) suspends one axle end by stainless steel wire and a fishing-line swivel. The swivel allows precession without winding up the suspension. Sprott describes the axle bobbing as nutation and precession becoming faster as spin decreases. A suspended support can move, whereas the calculation here assumes a fixed ; use the socket version for the closest realization. [ref]
A proposed quantitative extension is to record an overhead view of an axle marker against a fixed angle scale, together with a side view for . Time successive overhead passages to estimate ; count passages of a rim mark to estimate . Record the spin sense too. Measure and the centre of mass offset of the whole moving assembly, and determine its axial moment of inertia independently. Wheel, axle, support, release angle, and observation interval should stay the same between spin trials. Measuring both and distinguishes azimuthal precession from nutation; an overhead movie alone can miss the latter. These camera readouts and parameter checks are proposed here, not reported measurements from the demonstration pages.
For slow precession, compare with , and test whether reversing reverses with nearly unchanged magnitude. A brief interval minimizes spin loss from friction; repeat at several starting spin rates rather than interpreting an entire slowing run as one steady state. A suspension restoring torque governed by its torsion constant, socket friction, support motion, a misplaced centre of mass, and a push at release can all supply extra torque or change the initial conditions. The swivel reduces the twist that activates the suspension's torsion constant; it does not demonstrate zero torque.
Steady precession keeps constant; nutation changes while the axle may also precess. Sudden release generally excites both. A small initial drop is consistent with conservation of energy and conserved vertical angular momentum: some gravitational potential energy supplies the motion around the vertical, and the axial contribution to vertical angular momentum adjusts. Bearing friction may damp the bobbing, but an ideal undamped heavy symmetric top need not settle into steady precession. Chapter 20: Rotation in space explicitly distinguishes uniform precession from release transients and nutation (section 20-3, paragraphs following equation 20.15).[ref]
Static friction Created 2026-10-05 Updated 2026-10-14
Static friction is the tangential contact force that maintains zero contact slip. “Static” describes the contact state: both surfaces can move together in the chosen inertial frame. In the ideal dry-contact model, the actual static friction adjusts to the equations of motion, subject to a bound, rather than always taking its maximum value.[ref]
Here is the magnitude of the normal force and the coefficient of static friction. Equality means limiting static friction; it is a threshold, not an instruction to replace every unknown contact force by .
For a stipulated example, place a nonrotating block initially at rest on a stationary horizontal surface. Take gravitational acceleration and coefficient of static friction , with no other vertical force. The vertical force balance gives , so the largest allowed static friction magnitude is . Choose right as positive and apply a horizontal force . Remaining at rest requires Newton's second law to give
At , the static friction is ; at , it is . Both states have zero acceleration. At , balancing would require , outside the bound, so this initially resting block cannot remain at rest. Its subsequent acceleration requires a kinetic friction law; setting after contact slip begins would still use the wrong contact state. At exactly , the ideal inequality still permits rest at the threshold. These are model calculations, not measured material properties.
Figure 1.
Static friction adjusts to the applied force within its admissible bound
. Original signed horizontal model for the stipulated block: the shaded band is the allowed static friction, the solid line satisfies force balance, and the dashed line shows the demand outside that band. The crossed points at are impossible static demands, not sliding forces. Details.
The toy model used in kinetic friction makes the contact-state distinction explicit: , , and coefficient of kinetic friction . On stationary ground, an initially resting box pushed right with has . At it cannot remain at rest; once it slides right, and . At , rest is allowed with , whereas an already right-sliding box has and . The applied force alone does not specify the friction branch: contact slip and motion history matter.
For a flat contact with two tangential directions, the bound applies to a vector norm, not separately to each component:
For the stipulated bound, balancing horizontal components and requires a force magnitude , which is allowed. Components and require , which is forbidden even though each component separately is below . This circular bound assumes the same coefficient of static friction in every tangential direction. Near impending contact slip, the limiting static friction opposes the relative contact motion that would otherwise begin. Once actual contact slip exists, kinetic friction instead opposes its tangential relative velocity, which need not have the direction of the body's center of mass motion.
The normal force must also come from the equations of motion. On horizontal ground, an upward pull of magnitude at angle above horizontal gives, for a block remaining at rest with no other forces,
The sine component unloads the contact and the cosine component demands tangential support. These equations require ; if the supporting contact opens, this dry-contact model cannot supply a negative normal force. For the stipulated block and , the positive threshold is , with and . A downward pull increases instead. An inclined plane gives another reason why is not always .
To solve a new problem, impose zero contact slip, find the required static friction and normal force from the equations of motion, then check the bound. A demand inside it permits that contact state; a demand outside it rules the state out. For an ideal driven tire undergoing rolling without slipping on stationary ground, a forward static friction can accelerate the vehicle. Its role is to prevent contact slip, rather than to oppose all motion of the whole body.
Nor does the word “static” by itself make friction do zero work. The contact power delivered to a body is , a dot product with its material contact-point velocity in the chosen inertial frame. At an ideal contact undergoing rolling without slipping on stationary ground, , so this power is zero. For a rigid body, adding the translational and rotational contributions gives , where is the contact torque about the center of mass and its angular velocity. Counting only the first term omits the rotational contribution.
At a moving contact with zero contact slip, the two material contact points share a velocity that can be nonzero. For instance, a nonrotating block moving with an accelerating belt receives positive contact power when the belt's rightward velocity and rightward static friction are positive. The belt receives by Newton's third law. These contact contributions sum to zero in the ideal no-slip model, while the block's kinetic energy can increase. Zero contact slip and zero work on each body are different conditions.
An inclined plane tilted slowly from horizontal turns a coefficient of static friction into a critical angle. Assume a nonrotating block on a stationary, rigid, dry surface, with gravitational weight and the contact forces as its only forces. Take to be the angle between the uphill surface direction and horizontal. Let be a unit vector pointing uphill and a perpendicular unit vector pointing outward from the surface. Resolving the gravitational weight gives
The angle between the downward vertical and the inward normal is also . Thus the inward component uses cosine and the downhill component uses sine. These are components of one force, not two additional forces.
Figure 1.
Inclined plane force balance and the geometry of impending downhill contact slip
. Original diagram at the stipulated critical angle . Left: the three actual forces on a resting block. Right: a separate decomposition of gravitational weight into downhill and inward-normal components; the dashed diagonal represents their sum. The two panels must not be combined into a diagram with five applied forces. Details.
Before downhill contact slip, zero acceleration and Newton's second law require
The required static friction points uphill. Substituting into the bound and dividing by the positive gives
The tangent function increases on this range of angles, so the last admissible resting angle is
The inverse tangent takes a dimensionless quantity to an angle. At equality the ideal model still permits a limiting resting state; increasing further excludes it. At a smaller angle, is the demand ratio, not the coefficient of static friction.[ref]
For the stipulated , and , the critical angle is approximately . At , and , comfortably below the bound . At , maintaining rest would require , but the bound is only : rest is impossible. At , and . Notice that the limiting tangential force here is smaller than the horizontal limit because tilting reduces the normal force.
Cancellation of mass makes this relation useful: the ideal critical angle tests a contact coefficient without needing a calibrated force gauge. Doubling the block's mass doubles both demanded static friction and its bound, leaving unchanged if is unchanged. This is a testable model prediction. It need not survive a change in surface condition, a direction-dependent coefficient, appreciable deformation, or vibration.
The derivation also assumes continued contact and that sliding occurs before tipping or rolling without slipping. The resultant contact force must act within the supporting footprint so that the block can satisfy torque balance; a tall block may tip first. No extra tension, imposed tangential pull, or lift is included. In a slowly raised apparatus, quasistatic process means that motion of the board contributes negligible inertial forces while locating the threshold. Once downhill contact slip begins, a constant-velocity sliding angle would concern kinetic friction, not the onset of static friction.
Step-index optical fiber Created 2026-10-14 Updated 2026-10-18
A step-index optical fiber has a nearly uniform refractive index throughout its optical fiber core, with an abrupt decrease to in its optical fiber cladding. In a straight, ideal guide, meridional rays stay in a plane containing the optical axis and trace a zigzag through repeated total internal reflection. This is a geometrical optics approximation; it is particularly useful for a multimode optical fiber whose core diameter is large compared with the wavelength.
Figure 1.
Launch angle to the axis and incidence angle to the core–cladding normal
. Details.
The upper panel shows an accepted meridional ray; the lower panel enlarges the limiting geometry. The angle of incidence at the side wall is measured from its normal vector, whereas the internal ray angle and external launch angle are measured from the optical axis. Thus . The limiting ray is a boundary of the ideal model, rather than a complete normal mode solution.
Steradian Created 2026-10-14 Updated 2026-10-18
A steradian is the solid angle subtended at a sphere's center by a patch of surface area . The whole sphere subtends . In the SI, the steradian has unit one; retaining its symbol identifies a solid angle, just as radians identify an angle. A dimensionless quantity still needs its physical meaning specified.[ref]
Let be the number of projectiles actually incident on the foil during an exposure, its foil areal number density, and the probability of detecting an accepted particle. For a sufficiently small detector patch of area at distance from the scattering point, with its normal at angle to the line of sight,
The product is a dimensionless scattering probability in this approximation; is an expected value of counts, so it need not be an integer. The approximation requires a nearly constant differential scattering cross-section and efficiency across the patch and incident beam. For finite acceptance use , including the incident beam's spread if appreciable. A screen facing the foil has .
For an original numerical model, stipulate monoenergetic alpha particles with , , and a gold target with . Use the rounded model constant , where electronvolts and . Thus and . Choose , , , and . For example, facing the foil at gives this small-patch solid angle.
At , and , using barn . The expected signal is counts. At it is four times larger, about counts. Doubling foil areal number density or detector solid angle doubles these expected signals as long as the approximations continue to hold.
Figure 1.
Calculated Rutherford angular cross-section and finite-detector counts
. Original calculation for the stated ideal monoenergetic alpha beam and thin gold foil. The curve is a differential cross-section; the bars are expected counts for the specified small detector solid angle at separate settings. They are not measured 1909 or 1913 data, and do not sum to a total scattering probability. The curve is shown only from 20 to 160 degrees. Details.
An observation also contains backgrounds. For a stable source and matched geometry, an estimator is , where denotes exposure duration. If source activity changes, normalize by incident exposure as well. Background subtraction removes an estimated background; it does not make finite counting fluctuations disappear.
Thin lens Created 2026-10-05 Updated 2026-10-14
A thin lens models an optical lens by collapsing its refracting surfaces into one plane, neglecting thickness relative to the relevant radius of curvature values and object and image distances. Here use an ideal converging thin lens in air and the paraxial approximation: light rays make small angles with the optical axis, so Snell's law can be linearized using the small-angle approximation. Equal surrounding refractive indices on both sides give the familiar symmetric equation.[ref]
Put the thin lens at , with incident light travelling to the right. An object at has . The image coordinate is : for a real image and for a virtual image. The converging thin lens has focal length , and heights are signed relative to the optical axis. The thin lens equation and transverse magnification are
The expression for requires . Negative transverse magnification means inverted; positive transverse magnification means upright. Remember that the positive distance differs in sign from the object's coordinate . [ref].
For focal length , object distance , and object height , calculation gives
The real image is inverted, half as tall, and located to the right of the thin lens. A screen at that position receives the image because the outgoing light rays actually meet there.
Figure 1.
A converging thin lens forms a real image: , , ,
. The object height is exactly and the image height is in the ideal thin lens model. Both outgoing light rays travel to the right and intersect at the image tip. The vertical scale is enlarged for visibility; the drawing is a schematic of geometrical optics. Details.
For the same focal length and object height , move the object inside the front optical focus, to . Then
The virtual image is upright, twice as tall, and apparently to the left of the thin lens. Outgoing light rays still travel to the right; only their backward extensions intersect at the virtual image. A screen there cannot collect that image from the outgoing bundle. This geometry explains why a converging optical lens can act as a magnifier when held close to an object. [ref].
Figure 2.
A converging thin lens forms a virtual image: , , ,
. The object height is exactly and the image height is in the ideal thin lens model. Solid outgoing light rays have arrows to the right. Dashed backward extensions meet at the image tip; they are not transmitted light rays. The vertical scale is enlarged for visibility. Details.
Both diagrams use two rules for ray tracing. A light ray from the object's tip parallel to the optical axis reaches the thin lens at and exits along the straight line through the rear optical focus . Another light ray through the centre continues undeviated in the ideal thin lens model. Their intersection, or the intersection of their backward extensions, locates the image tip. [ref].
A short geometric proof outline makes the signs transparent. The two outgoing straight lines are
For nonzero , equating their heights at gives , hence the thin lens equation; the centre light ray gives , hence the transverse magnification. This derives the image equations from the ideal ray tracing rules, whose physical justification comes from Snell's law in the paraxial approximation.
At , the two outgoing straight lines are parallel: there is no finite image position. For the real image has ; for the virtual image has . These cases let an optical camera designer choose a receiving position and let a user understand a magnifier. An actual optical lens has finite apertures, which cause diffraction and impose diffraction-limited resolution; optical aberrations can further blur the image. The diagrams are ideal geometrical optics, with exact coordinates within that model, rather than exact predictions of Maxwell's equations. [ref].
Thomson charge-to-mass experiment Created 2026-10-18 Updated 2026-10-20
The Thomson charge-to-mass experiment infers the magnitude of an electron's charge-to-mass ratio by combining electric and magnetic deflection of cathode rays. The central idea is to determine speed separately from magnetic curvature: a known speed turns the observed gyroradius into a measurement of .
In 1897, J. J. Thomson used two grounded slits in an evacuated glass tube, then aluminium plates long, wide and apart. A battery supplied their electric potential difference. Deflected cathode rays produced a phosphorescence patch on the glass; an external scale and movable luminous pointer recorded its position in darkness. Greater evacuation reduced gas electrical conductivity that screened the electric field; reversing plate polarity reversed deflection. External coils supplied the magnetic field, calibrated by induction against larger coils. He adjusted equal electric and magnetic deflections. [ref]
His comparison included air, hydrogen, carbon dioxide, and aluminium versus platinum cathodes, supporting a common carrier. He explicitly noted uncorrected magnetic bending outside the plates. His tables give , the reciprocal of the magnitude used here. The inferred ratio alone could not separate electric charge from mass. [ref]
To connect this readout with the Lorentz force, derive a simple nonrelativistic model in modern SI notation. Let the uniform deflecting region have length , followed by a field-free drift of length . Assume a narrow speed distribution, small deflection angles, negligible collisions, and matching electric and magnetic field profiles. For an electron with speed , the electric acceleration has magnitude , the transit time is approximately , and the subsequent drift adds exit transverse velocity times . Thus the displacement magnitudes measured separately with only electric field or only magnetic field are
The electric expression follows from constant transverse acceleration; the magnetic expression uses its small-deflection approximation. Equal displacement magnitudes then give
This is an ideal derivation of the comparison principle, not a numerical reanalysis of the historical tube. Different exterior magnetic field profiles invalidate cancellation of the common geometrical factor. The comparison determines through deflection and the known apparatus dimensions; it does not require a downstream semicircle.
For a second, deliberately different teaching geometry, combine a velocity selector with a separate region containing only a uniform magnetic field perpendicular to the selected velocity. Here belongs to the velocity selector, while belongs to the analyzer: they need not be equal. The magnetic Lorentz force supplies the centripetal acceleration, so
If the analyzer turns the beam through a semicircle before it hits a screen in the entry plane, the separation between entrance and impact is the diameter: . For a shorter observed arc, the screen displacement is not generally a radius; fit the appropriate circle geometry. This two-stage velocity selector and curvature apparatus is an original ideal teaching model, not a claim that Thomson's Fig. 2 used a separate selector and semicircular analyzer.
Figure 1.
Inferring an electron's charge-to-mass ratio from selected speed and magnetic curvature
. Original ideal analyzer with zero electric field, magnetic field out of the page, and negative electric charge bending upward. The semicircle has screen separation . All numerical inputs are stipulated teaching values, not historical measurements. The magnetic field differs from the upstream velocity selector magnetic field . Details.
For a worked example, stipulate , , , and . The selected speed and inferred charge-to-mass ratio magnitude are
The SI units provide an independent check: and , because . The charge-to-mass ratio of the electron is negative; this calculation gives its magnitude. The bending direction gives the sign of the electric charge once the magnetic field direction is known. Scaling both and by the same positive factor preserves every displayed trajectory, so an independent electric charge measurement is required to determine mass separately.
The curvature formula assumes nonrelativistic momentum . At higher speeds, the relativistic cyclotron orbit gives , hence , where is the Lorentz factor; the ideal straight-through selection still follows from vanishing Lorentz force. The stipulated speed is about times the speed of light, making about . For this example the nonrelativistic approximation is adequate, but no massive particle can be selected at . Finite slit widths, collisions with residual gas, uncertain magnetic field calibration, and fields outside the ideal boundaries limit a real inference; repeat at several selected speeds and analyzer strengths to test consistency of rather than trusting one spot position.
Torque Created 2026-09-24 Updated 2026-10-14
Torque measures a force's turning effect about a specified origin. The geometry in the angular momentum diagram applies with force replacing momentum: transverse forces give positive or negative torque, while a radial force gives zero. A longer perpendicular lever arm makes the same force more effective, explaining why pushing near the end of a handle is useful.
For a force applied at position from a fixed origin in an inertial frame, its torque, or moment of force, is
Here , is the angle between position and force, and is the perpendicular lever arm. Direction follows the right-hand rule; in the plane , positive counterclockwise as viewed from . The International System of Units unit is . Although torque and energy have the same physical dimensions, torque is an axial vector and energy is a scalar; their roles differ.
For and , . Applying the same force at gives ; reversing it gives a negative torque; directing it along gives zero. More generally, sum to find the total torque about one common origin.
For a constant-mass point mass, the product rule and Newton's second law show why net torque changes angular momentum:
The first cross product vanishes because its factors are parallel. For a collection with canceling internal torques, the remaining sum is external torque, giving conservation of angular momentum when it vanishes.[ref]
A nonzero torque can turn the direction of angular momentum as well as change its magnitude. Indeed, the dot product gives : a perpendicular torque changes direction without instantaneously changing the magnitude. This is the geometry behind gyroscope precession. For a rapidly spinning symmetric top with a fixed tip, centre of mass distance from the tip, mass , and spin-dominated angular momentum magnitude , the slow steady precession approximation gives , where is gravitational acceleration. [ref] This is an approximation with ; the uniform precession of a heavy symmetric top retains contributions omitted by the spin-dominated estimate.
A path along a circle can have variable areal velocity. As an illustrative controlled trajectory, keep a point mass on a circle of radius with angle
Its acceleration in polar coordinates and the required net force are
where and are the radial and transverse unit vectors. A circular guide can supply the radial force, while a tangential drive supplies . Hence
For in illustrative units, the three equal time intervals , and sweep areas , and . Their difference comes from the transverse force's positive torque, even though the radius and path shape stay fixed. The area under each areal velocity graph segment equals the corresponding swept area.
Figure 1.
A transverse force gives increasing areal velocity and unequal swept areas in equal times
. Details.
Torsional stiffness 2026-10-25
The derivative of an axial torque with respect to relative end-rotation angle, evaluated at the operating configuration. In a linear torsion spring, .
Torsional stiffness per unit twist Created 2026-10-25 Updated 2026-11-05
For a uniform rod of length and twist per unit length , the end-rotation angle is . The chain rule gives , where is the torsional stiffness. If a source defines a normalized torque , its derivative is .
Torsion balance 2026-10-13
A torsion balance measures a weak torque by suspending a body from a thin fiber and reading its twist angle. The fiber supports the body's gravitational weight while permitting rotation about the suspension axis. In the range of linear elasticity, a twist in radians, measured from the untwisted reference orientation, produces a restoring torque
The torsion constant sets the sensitivity. At static equilibrium with an applied torque and no other axial torque, . A perpendicular force at lever arm therefore gives . The torsion balance measures a turning effect: a force whose line of action passes through the suspension axis gives no axial torque. The Cavendish torsion balance is the gravitational application; Coulomb's law supplies an electrical one. [ref]
Figure 1.
Torsion balance readout: fiber twist, force geometry, and returning the body to a fixed angle
. Details.
The original schematic separates two ways of reading the same torque. In deflection operation the top attachment stays fixed and the body rotates. In null operation the experimenter rotates the top attachment by while returning the body's laboratory angle to its original value. If the initially untwisted configuration has , the fiber twist is , not alone. Thus
For a positive applied torque, holding requires . Keeping the body at the same angle keeps the lever arm and source geometry fixed, making comparison of different applied forces easier. Either readout still requires a calibrated torsion constant and a stable reference orientation.
An illustrative calculation shows the amplification: with , , and , the applied torque is and the equilibrium twist is . These are stipulated values, not measured data. Reducing the torsion constant tenfold increases this twist tenfold, provided the fiber remains in its calibrated linear elasticity range. The cost is a slower response, explained by the oscillation period in torsion constant.
A concrete laboratory experiment is PASCO's Coulomb balance: level its counterbalanced rod, discharge both conducting spheres, and set the unloaded zero. Charge the spheres at maximum separation; switch off the charging supply. Move the second sphere to a known center separation , then turn the suspension dial until the rod returns to its index mark. Record the dial change and , recharge, and repeat at several separations. The manual recommends a draft-free room, clean insulating supports, and recharging before each reading: leakage, especially in humid conditions, otherwise changes the electric charges during the sequence. At close separations the conducting spheres redistribute charge, so the point charge approximation needs correction. [ref]
For constant electric charges and a fixed perpendicular lever arm, the Coulomb's law prediction is . Plotting the logarithm of twist magnitude against the logarithm of separation gives , so the predicted slope is . Absolute force measurement additionally needs the torsion constant; comparing ratios can eliminate it if it remains stable. Repeating a reference separation between other settings distinguishes a separation effect from a changing signal. A declining reading at the reference separation would invalidate the assumption of unchanged electric charges, even if a distance plot looks smooth.
The historical electrical example is Coulomb's first memoir of 1785. His apparatus enclosed a suspended needle with a small ball and a second ball; an adjustable head twisted the suspension. After charging the balls by contact, he reported angular separations , , and with head settings , , and . The total twists were approximately , , and : fourfold restoring torque accompanied approximately halved separation. These are his reported observations, not data from our diagrams. [ref] A precise reconstruction must use center distances and the changing lever arm, rather than identify angular separation exactly with distance; Alberto A. Martínez's replication explicitly analyzes that geometry. [ref]
Sensitivity also exposes changes of the apparatus itself. Fleischer and colleagues' cryogenic torsion balance used a temperature-controlled enclosure to reduce vacuum-vessel top-plate temperature fluctuations to approximately , limiting changes in suspension geometry from thermal expansion. They used a mild bake-out near to speed initial fiber relaxation and reduce slow zero motion. Their optical readout compared the pendulum mirror with an internal reference mirror to reject shared optical motion. Room-temperature thermal radiation entering through the optical opening heated the pendulum; a cold filter reduced that load. The authors could not directly measure the pendulum's temperature without disturbing it, and explicitly distinguished the cold shield's temperature from the body's. Cooling therefore requires checking the actual noise and thermal environment, rather than assuming that the fiber and body share the shield's temperature. [ref]
A useful control strategy is to record unloaded readings and temperature before and after each signal sequence, recalibrate the torsion constant under the same conditions, and compare forward and reverse settings. The algebra of torsion balance zero drift shows precisely which offsets such comparisons can cancel. A fine angular scale alone does not establish a small measurement error.
Torsion balance zero drift is slow motion of the unloaded reference angle during a measurement. If the torsion constant remains fixed, a constant applied torque gives . For two equal and opposite applied torques measured at the same reference zero, their equilibrium angles differ by . A stable offset cancels; a changing zero contributes and does not cancel automatically.
A simple symmetric sequence makes the limitation explicit. Let be settled equilibrium angles for applied torques at equally spaced times . If the unloaded zero is linear in time, , and and remain fixed, then
The arithmetic average of the outer zero values equals the middle zero, so both the constant offset and linear drift cancel. Curved zero motion, unequal time spacing, changing torsion constant, changing signal strength, or unsettled oscillations violate these assumptions. This is an algebraic control example, not a claim that every torsion balance follows a linear drift law.
Torsion constant Created 2026-10-14 Updated 2026-10-18
The torsion constant, or torsional spring constant, is the positive restoring torque per unit twist angle of a complete suspension in its linear elasticity range:
Its SI unit is . The minus sign describes restoration toward the untwisted orientation. The derivative specifies a local stiffness if the response is not globally linear; using one constant over a finite range additionally requires a straight calibration curve. Return to the same zero after unloading tests recoverable elastic deformation; repeat loading in both directions to check whether the response depends on its previous loading. Staying below permanent deformation is necessary, but does not alone prove proportionality between torque and twist.
For an ideal uniform circular wire of length , radius , and shear modulus , the filament torsional stiffness is , with polar second moment of area . Uniform twist gives as the twist per unit length, so
Here is stored elastic energy. Doubling the wire's radius multiplies the ideal torsion constant by ; doubling its length halves it. This explains why a long thin fiber is useful for weak torque measurement. The formula assumes linear elasticity with uniform material and circular section; it does not calibrate arbitrary ribbons, clamps, or a compound suspension. Within this ideal model, the equipartition theorem predicts an equilibrium thermal mean-square angular displacement , where is the Boltzmann constant and the uniform absolute temperature. A softer suspension magnifies both the signal and its thermal fluctuations.
Static calibration supplies known torques without assuming the unknown interaction being measured. Apply a known perpendicular force at lever arm , record the change from the unloaded twist, and use
Several positive and negative settings test proportionality; fit the slope of applied torque against twist and retain a possible intercept. A nonzero intercept must not be silently absorbed into the slope. Convert degrees to radians before reporting . PASCO's procedure turns the Coulomb balance on its side and adds small known masses to generate a gravitational weight at the sphere's lever arm, returning the rod to its index mark by turning the dial. Its tabulated coefficient is force per degree: multiply by the lever arm and to obtain our torsion constant. [ref]
Figure 1.
Toy torsion calibrations: static slope and a period corrected for viscous damping
. Details.
The figure's ideal static calibration uses : an applied torque of gives . Both signs lie on the same straight line. The plotted points are calculated examples, not experimental observations; they cannot demonstrate a real fiber's linearity.
Dynamic calibration instead measures the oscillation period with known total suspended moment of inertia . For negligible damping, small free oscillations about a fixed reference obey simple harmonic motion:
Include the rod, mirrors, and any attachments in unless their contributions are demonstrably negligible. Keep the applied torque absent or independent of angle. If an external torque has derivative at equilibrium, linearization gives effective stiffness : timing alone then measures that combination, and stability requires . A constant applied torque merely shifts equilibrium. Non-negligible damping changes the measured period; damped torsional oscillation gives a correction under a specified damping model. Agreement between static and dynamic calibrations is a useful check on the assumed moment of inertia, reference stability, and restoring law, rather than a reason to ignore their assumptions.
Torsion spring Created 2026-10-18 Updated 2026-11-05
An ideal linear torsion spring exerts a restoring torque proportional to the relative angle between its two ends. Integrating the torque gives its elastic potential energy. A spring connecting two rotating bodies contributes to the potential energy; a spring connected to a fixed frame is obtained by setting one angle to zero. The coefficient is the torsional spring constant.
Total internal reflection Created 2026-09-29 Updated 2026-10-18
Total internal reflection occurs when a wave travels from higher to lower refractive index above the critical angle for total internal reflection, leaving no propagating transmitted plane electromagnetic wave normal to the interface.
At an infinite planar interface, total internal reflection returns all incident normal power in the reflected plane electromagnetic wave. Assume homogeneous dielectrics with isotropy, linearity, no dielectric loss, magnetic permeability , and positive real refractive indices . Above the critical angle for total internal reflection, both TE polarization and TM polarization have unit optical reflectance despite the external evanescent wave.[ref]
This makes total internal reflection useful for guiding light in an optical fiber: suitable internal incidence angles keep energy inside successive boundaries. Its more surprising feature is that perfect optical reflectance coexists with an external electric field. The evanescent field in total internal reflection can interact with a nearby object, as the frustrated total internal reflection experiment demonstrates.
For an original idealized example, choose , at vacuum wavelength . At angle of incidence , Snell law for electromagnetic waves gives an angle of refraction , so a transmitted light ray still emerges. At , its direction becomes tangent to the boundary. At , the proposed sine of a real angle of refraction would be : the transmitted wavevector must instead have an imaginary normal component. These are predictions for the stipulated media, not measured properties of a particular block.
Figure 1.
Constructed ray geometry just below, at, and above the critical angle for refractive indices 1.5 and 1; arrows indicate directions rather than relative powers
. Details.
A real semicircular-block experiment isolates this threshold. The University of Maryland laboratory instructions place a laser, motor-driven rotation stage and photodetector together; an aperture limits the detector voltage. The semicircular block is centered on the rotation axis, with the photodetector aligned along its flat face. The instructions identify a strong grazing-beam signal and a weaker signal just before the critical angle for total internal reflection. The readout is detector voltage versus stage angle. Retracing the incident laser beam identifies normal incidence for alignment.[ref]
The semicircular shape supplies a geometric control: a light ray passing radially through the curved face enters at normal incidence, avoiding additional entrance refraction. The weaker signal near the flat face locates a limiting angle of refraction; a vanishing remote-detector signal alone would not establish that the external electric field vanishes. Beam width and alignment limit angular resolution; no measured threshold or decay depth is supplied.[ref]
Triangle Created 2026-09-24 Updated 2026-10-14
A triangle is the convex hull of three noncollinear points: the three vertices must not lie on one line. Its boundary consists of the three joining line segments; depending on context, "triangle" can mean this boundary or the filled region it encloses. Here a triangle's area refers to the filled region. The noncollinearity assumption excludes a collapsed shape with zero area, for which ordinary interior angles are not defined.
For example, the positions , and form a right triangle with a right angle at the origin. Taking the side of length as its base gives perpendicular height , so its area is . The height is measured at a right angle to the chosen base; it is not generally the length of another side. In this example it happens to be a side because the triangle is a right triangle.
By contrast, side lengths define a valid triangle: each side is shorter than the sum of the other two, as required by the strict triangle inequality. But , so this is not a right triangle and the Pythagorean theorem cannot calculate its longest side from the other two. The law of cosines instead gives the opposite interior angle through
This example separates the definition of a triangle from the additional assumption of a right angle.
Every triangle in the Euclidean plane has interior angles summing to radians, a result proved in Euclid's Elements I.32.[ref] It lets two measured angles determine the third, and underlies the angle-angle criterion for similar triangles. The qualification "Euclidean plane" matters: the earlier spherical triangle demonstrates a different sum.
Trigonometric function Created 2026-09-24 Updated 2026-10-13
Trigonometric functions turn an angle into a coordinate or a ratio of lengths. Start at on the unit circle and rotate counterclockwise through radians: the resulting point is
The cosine records horizontal position and the sine records vertical position. This definition continues around the whole circle, including negative angles, so the signs encode direction rather than requiring a separate rule for each right triangle.
Figure 1.
Sine and cosine as signed circle coordinates and periodic traces
. Details.
The unit circle picture explains why these functions are useful beyond measuring triangles. The two coordinates of a point rotating at constant angular speed are periodic functions. Scaling the radius to and using gives and . A circular motion becomes two simple repeating traces, connecting Euclidean geometry, simple harmonic motion, and Fourier series.
For an acute angle in a right triangle, rescaling its hypotenuse to one recovers the familiar ratios: sine is opposite side divided by hypotenuse, and cosine is adjacent side divided by hypotenuse. The tangent function is their ratio, , wherever the denominator is nonzero; the secant function, cosecant, and cotangent give the other reciprocal ratios.
The same names extend to complex numbers through the complex exponential:
These definitions agree with the circle interpretation for real angles. For complex arguments, the values need not lie between and ; the literal circle-coordinate picture is restricted to real arguments. [ref]
Stipulate a distant circular source of uniform angular brightness, full angular diameter in radians, and narrow optical bandwidth around wavelength . Distinct source patches emit independently. Assume each collector is small enough not to resolve the disk individually. For a sky offset from the disk centre, the baseline-dependent phase difference is , up to channel-sign convention. Summing independent patch contributions makes the equal-delay first-order optical coherence the normalized Fourier transform of angular brightness:
Choose the horizontal coordinate along , put , and integrate along vertical chords of the disk:
The imaginary part cancels between opposite chords. Here is the order-one Bessel function of the first kind. One way to obtain the last equality is to integrate the exponential's power series term by term on the finite disk. Equivalently the result is specified by the convergent series
At take the continuous limit ; starts as . This is why very short interferometric baselines give little leverage on angular diameter. Larger disks lose spatial optical coherence at shorter baselines.
The first positive zero of is , so
This is a full diameter convention. The angle must be converted before substitution: one arcsecond is radians, and one milliarcsecond, abbreviated mas, is arcseconds. For the stipulated and , and . At , the model gives and .
Figure 1.
Stipulated uniform-disk model: signed field coherence, squared visibility and finite-gate intensity correlation versus interferometric baseline
. Original calculated curves for a 5-mas disk at 500 nm, with no measured points. The lower panel uses one polarization, independent signal fractions 0.8 in each channel, and the explicitly specified exponential temporal correlation and 50-ps gate below. It is not a fit to Sirius. Details.
Beyond , changes sign but stays nonnegative and develops weak further lobes. A single measured squared visibility can therefore match several angular diameters; sampling several interferometric baselines constrains the fit. Limb darkening, spectral averaging, or resolved collector apertures change the uniform-disk prediction. A uniform-disk diameter is a parameter of that brightness model; converting it to a physical stellar radius also requires distance and an appropriate brightness profile.